Orifice plate

Last updated

An orifice plate is a device used for measuring flow rate, for reducing pressure or for restricting flow (in the latter two cases it is often called a restriction plate).

Contents

Description

Orifice plate showing vena contracta Orifice.png
Orifice plate showing vena contracta

An orifice plate is a thin plate with a hole in it, which is usually placed in a pipe. When a fluid (whether liquid or gaseous) passes through the orifice, its pressure builds up slightly upstream of the orifice [1] but as the fluid is forced to converge to pass through the hole, the velocity increases and the fluid pressure decreases. A little downstream of the orifice the flow reaches its point of maximum convergence, the vena contracta (see drawing to the right) where the velocity reaches its maximum and the pressure reaches its minimum. Beyond that, the flow expands, the velocity falls and the pressure increases. By measuring the difference in fluid pressure across tappings upstream and downstream of the plate, the flow rate can be obtained from Bernoulli's equation using coefficients established from extensive research. [2]

In general, the mass flow rate measured in kg/s across an orifice can be described as

[3]
where: 
= coefficient of discharge, dimensionless, typically between 0.6 and 0.85, depending on the orifice geometry and tappings
= diameter ratio of orifice diameter to pipe diameter , dimensionless
= expansibility factor, 1 for incompressible gases and most liquids, and decreasing with pressure ratio across the orifice, dimensionless
= internal orifice diameter under operating conditions, m
= fluid density in plane of upstream tapping, kg/m³
= differential pressure measured across the orifice, Pa

The volume flow rate measured in m3/s is

[3]

The overall pressure loss in the pipe due to an orifice plate is lower than the measured differential pressure, typically by a factor of . [4]

Application

Orifice plates are most commonly used to measure flow rates in pipes, when the fluid is single-phase (rather than being a mixture of gases and liquids, or of liquids and solids) and well-mixed, the flow is continuous rather than pulsating, the fluid occupies the entire pipe (precluding silt or trapped gas), the flow profile is even and well-developed and the fluid and flow rate meet certain other conditions. Under these circumstances and when the orifice plate is constructed and installed according to appropriate standards, the flow rate can easily be determined using published formulae based on substantial research and published in industry, national and international standards. [5]

An orifice plate is called a calibrated orifice if it has been calibrated with an appropriate fluid flow and a traceable flow measurement device.

Plates are commonly made with sharp-edged circular orifices and installed concentric with the pipe and with pressure tappings at one of three standard pairs of distances upstream and downstream of the plate; these types are covered by ISO 5167 and other major standards. There are many other possibilities. The edges may be rounded or conical, the plate may have an orifice the same size as the pipe except for a segment at top or bottom which is obstructed, the orifice may be installed eccentric to the pipe, and the pressure tappings may be at other positions. Variations on these possibilities are covered in various standards and handbooks. Each combination gives rise to different coefficients of discharge which can be predicted so long as various conditions are met, conditions which differ from one type to another. [5]

Once the orifice plate is designed and installed, the flow rate can often be indicated with an acceptably low uncertainty simply by taking the square root of the differential pressure across the orifice's pressure tappings and applying an appropriate constant.

Orifice plates are also used to reduce pressure or restrict flow, in which case they are often called restriction plates. [6] [7]

Pressure tappings

There are three standard positions for pressure tappings (also called taps), commonly named as follows:

These types are covered by ISO 5167 and other major standards. Other types include

The measured differential pressure differs for each combination and so the coefficient of discharge used in flow calculations depends partly on the tapping positions.

The simplest installations use single tappings upstream and downstream, but in some circumstances these may be unreliable; they might be blocked by solids or gas-bubbles, or the flow profile might be uneven so that the pressures at the tappings are higher or lower than the average in those planes. In these situations multiple tappings can be used, arranged circumferentially around the pipe and joined by a piezometer ring, or (in the case of corner taps) annular slots running completely round the internal circumference of the orifice carrier.

Plate

Standards and handbooks are mainly concerned with sharp-edged thin plates. In these, the leading edge is sharp and free of burrs and the cylindrical section of the orifice is short, either because the entire plate is thin or because the downstream edge of the plate is bevelled. Exceptions include the quarter-circle or quadrant-edge orifice, which has a fully rounded leading edge and no cylindrical section, and the conical inlet or conical entrance plate which has a bevelled leading edge and a very short cylindrical section. The orifices are normally concentric with the pipe (the eccentric orifice is a specific exception) and circular (except in the specific case of the segmental or chord orifice, in which the plate obstructs just a segment of the pipe). Standards and handbooks stipulate that the upstream surface of the plate is particularly flat and smooth. Sometimes a small drain or vent hole is drilled through the plate where it meets the pipe, to allow condensate or gas bubbles to pass along the pipe.

Pipe

Standards and handbooks stipulate a well-developed flow profile; velocities will be lower at the pipe wall than in the centre but not eccentric or jetting. Similarly the flow downstream of the plate must be unobstructed, otherwise the downstream pressure will be affected. To achieve this, the pipe must be acceptably circular, smooth and straight for stipulated distances. Sometimes when it is impossible to provide enough straight pipe, flow conditioners such as tube bundles or plates with multiple holes are inserted into the pipe to straighten and develop the flow profile, but even these require a further length of straight pipe before the orifice itself. Some standards and handbooks also provide for flows from or into large spaces rather than pipes, stipulating that the region before or after the plate is free of obstruction and abnormalities in the flow.

Theory

Incompressible flow

By assuming steady-state, incompressible (constant fluid density), inviscid, laminar flow in a horizontal pipe (no change in elevation) with negligible frictional losses, Bernoulli's equation (which expresses the conservation of energy of an incompressible fluid parcel as it moves between two points on the same streamline) can be rewritten without the gravitational potential energy term and reduced to:

or:

By continuity equation:

  or   and  :

Solving for :

and:

The above expression for gives the theoretical volume flow rate. Introducing the beta factor as well as the discharge coefficient :

And finally introducing the meter coefficient which is defined as to obtain the final equation for the volumetric flow of the fluid through the orifice which accounts for irreversible losses:

Multiplying by the density of the fluid to obtain the equation for the mass flow rate at any section in the pipe: [8] [9] [10] [11]

where: 
= volumetric flow rate (at any cross-section), m³/s
= theoretical volumetric flow rate (at any cross-section), m³/s
= mass flow rate (at any cross-section), kg/s
= theoretical mass flow rate (at any cross-section), kg/s
= coefficient of discharge, dimensionless
= orifice flow coefficient, dimensionless
= cross-sectional area of the pipe, m²
= cross-sectional area of the orifice hole, m²
= diameter of the pipe, m
= diameter of the orifice hole, m
= ratio of orifice hole diameter to pipe diameter, dimensionless
= theoretical upstream fluid velocity, m/s
= theoretical fluid velocity through the orifice hole, m/s
= fluid upstream pressure, Pa   with dimensions of kg/(m·s² )
= fluid downstream pressure, Pa   with dimensions of kg/(m·s² )
= fluid density, kg/m³

Deriving the above equations used the cross-section of the orifice opening and is not as realistic as using the minimum cross-section at the vena contracta. In addition, frictional losses may not be negligible and viscosity and turbulence effects may be present. For that reason, the coefficient of discharge is introduced. Methods exist for determining the coefficient of discharge as a function of the Reynolds number. [9]

The parameter is often referred to as the velocity of approach factor [8] and multiplying the coefficient of discharge by that parameter (as was done above) produces the flow coefficient . Methods also exist for determining the flow coefficient as a function of the beta function and the location of the downstream pressure sensing tap. For rough approximations, the flow coefficient may be assumed to be between 0.60 and 0.75. For a first approximation, a flow coefficient of 0.62 can be used as this approximates to fully developed flow.

An orifice only works well when supplied with a fully developed flow profile. This is achieved by a long upstream length (20 to 40 pipe diameters, depending on Reynolds number) or the use of a flow conditioner. Orifice plates are small and inexpensive but do not recover the pressure drop as well as a venturi, nozzle, or venturi-nozzle does. Venturis also require much less straight pipe upstream. A venturi meter is more efficient, but usually more expensive and less accurate (unless calibrated in a laboratory) than an orifice plate.

Compressible flow

In general, equation (2) is applicable only for incompressible flows. It can be modified by introducing the expansibility factor, (also called the expansion factor) to account for the compressibility of gasses.

is 1.0 for incompressible fluids and it can be calculated for compressible gases [9] using empirically determined formulae as shown below in computation.

For smaller values of β (such as restriction plates with β less than 0.25 and discharge from tanks), if the fluid is compressible, the rate of flow depends on whether the flow has become choked. If it is, then the flow may be calculated as shown at choked flow (although the flow of real gases through thin-plate orifices never becomes fully choked [lower-alpha 1] [13] By using a mechanical energy balance, compressible fluid flow in un-choked conditions may be calculated as: [10] [11] [14]

or

Under choked flow conditions, the fluid flow rate becomes: [10]

or

where: 
= heat capacity ratio (), dimensionless ( for air)
, = mass and volumetric flow rate, respectively, kg/s and m³/s
= real gas density under upstream conditions, kg/m³
 and other symbols are defined as above

Computation according to ISO 5167

Flow rates through an orifice plate can be calculated without specifically calibrating the individual flowmeter so long as the construction and installation of the device complies with the stipulations of the relevant standard or handbook. The calculation takes account of the fluid and fluid conditions, the pipe size, the orifice size and the measured differential pressure; it also takes account of the coefficient of discharge of the orifice plate, which depends upon the orifice type and the positions of the pressure tappings. With local pressure tappings (corner, flange and D+D/2), sharp-edged orifices have coefficients around 0.6 to 0.63, [15] while the coefficients for conical entrance plates are in the range 0.73 to 0.734 and for quarter-circle plates 0.77 to 0.85. [5] The coefficients of sharp-edged orifices vary more with fluids and flow rates than the coefficients of conical-entrance and quarter-circle plates, especially at low flows and high viscosities.

For compressible flows such as flows of gases or steam, an expansibility factor or expansion factor is also calculated. This factor is primarily a function of the ratio of the measured differential pressure to the fluid pressure and so can vary significantly as the flow rate varies, especially at high differential pressures and low static pressures.

The equations provided in American and European national and industry standards and the various coefficients used to differ from each other even to the extent of using different combinations of correction factors, but many are now closely aligned and give identical results; in particular, they use the same Reader-Harris/Gallagher (1998) equation for the coefficient of discharge for sharp-edged orifice plates. The equations below largely follow the notation of the international standard ISO 5167 and use SI units. [3] [16]

Volume flow rate:

Mass flow rate:

[3]

Coefficient of discharge

Coefficient of discharge for sharp-edged orifice plates with corner, flange or D and D/2 tappings and no drain or vent hole (Reader-Harris/Gallagher equation):

and if D < 71.2mm in which case this further term is added to C:
[16] [lower-alpha 2]
In the equation for C,
and only the three following pairs of values for L1 and L'2 are valid:
corner tappings:
flange tappings: [lower-alpha 2]
D and D/2 tappings:

Expansibility factor

Expansibility factor, also called expansion factor, for sharp-edged orifice plates with corner, flange or D and D/2 tappings:

if [16] :5.3.2.2 (at least - standards vary) [lower-alpha 3]
[16]
but for incompressible fluids, including most liquids
where: 
= coefficient of discharge, dimensionless
= internal orifice diameter under operating conditions, m
= internal pipe diameter under operating conditions, m
= fluid absolute static pressure in plane of upstream tapping, Pa
= fluid absolute static pressure in plane of downstream tapping, Pa
= mass flow rate, kg/s
= volume flow rate, m3/s
= pipe Reynolds number, , dimensionless
= diameter ratio of orifice diameter to pipe diameter, , dimensionless
= differential pressure, Pa
= expansibility factor, also called expansion factor, dimensionless
= isentropic exponent, often approximated by specific heat ratio, dimensionless
= dynamic viscosity of the fluid, Pa.s
= fluid density in plane of upstream tapping, kg/m³

Overall pressure loss

The overall pressure loss caused by an orifice plate is less than the differential pressure measured across tappings near the plate. For sharp-edged plates such as corner, flange or D and D/2 tappings, it can be approximated by the equation

[16] :13

or

  [16] :13
where 
= overall pressure loss, Pa
 and other symbols are as above

See also

Related Research Articles

<span class="mw-page-title-main">Mach number</span> Ratio of speed of an object moving through fluid and local speed of sound

The Mach number, often only Mach, is a dimensionless quantity in fluid dynamics representing the ratio of flow velocity past a boundary to the local speed of sound. It is named after the Austrian physicist and philosopher Ernst Mach.

<span class="mw-page-title-main">Navier–Stokes equations</span> Equations describing the motion of viscous fluid substances

The Navier–Stokes equations are partial differential equations which describe the motion of viscous fluid substances. They were named after French engineer and physicist Claude-Louis Navier and the Irish physicist and mathematician George Gabriel Stokes. They were developed over several decades of progressively building the theories, from 1822 (Navier) to 1842–1850 (Stokes).

In fluid dynamics, the Darcy–Weisbach equation is an empirical equation that relates the head loss, or pressure loss, due to friction along a given length of pipe to the average velocity of the fluid flow for an incompressible fluid. The equation is named after Henry Darcy and Julius Weisbach. Currently, there is no formula more accurate or universally applicable than the Darcy-Weisbach supplemented by the Moody diagram or Colebrook equation.

<span class="mw-page-title-main">Rankine–Hugoniot conditions</span> Concept in physics

The Rankine–Hugoniot conditions, also referred to as Rankine–Hugoniot jump conditions or Rankine–Hugoniot relations, describe the relationship between the states on both sides of a shock wave or a combustion wave in a one-dimensional flow in fluids or a one-dimensional deformation in solids. They are named in recognition of the work carried out by Scottish engineer and physicist William John Macquorn Rankine and French engineer Pierre Henri Hugoniot.

<span class="mw-page-title-main">Onsager reciprocal relations</span> Relations between flows and forces, or gradients, in thermodynamic systems

In thermodynamics, the Onsager reciprocal relations express the equality of certain ratios between flows and forces in thermodynamic systems out of equilibrium, but where a notion of local equilibrium exists.

<span class="mw-page-title-main">Venturi effect</span> Reduced pressure caused by a flow restriction in a tube or pipe

The Venturi effect is the reduction in fluid pressure that results when a moving fluid speeds up as it flows through a constricted section of a pipe. The Venturi effect is named after its discoverer, the 18th-century Italian physicist Giovanni Battista Venturi.

In fluid dynamics, the pressure coefficient is a dimensionless number which describes the relative pressures throughout a flow field. The pressure coefficient is used in aerodynamics and hydrodynamics. Every point in a fluid flow field has its own unique pressure coefficient, Cp.

In fluid dynamics, drag, sometimes referred to as fluid resistance, is a force acting opposite to the relative motion of any object, moving with respect to a surrounding fluid. This can exist between two fluid layers, two solid surfaces, or between a fluid and solid surface. Drag forces tend to decrease fluid velocity relative to the solid object in the fluid's path.

The Fanning friction factor, named after John Thomas Fanning, is a dimensionless number used as a local parameter in continuum mechanics calculations. It is defined as the ratio between the local shear stress and the local flow kinetic energy density:

Choked flow is a compressible flow effect. The parameter that becomes "choked" or "limited" is the fluid velocity.

<span class="mw-page-title-main">Torricelli's law</span> Theorem in fluid mechanics

Torricelli's law, also known as Torricelli's theorem, is a theorem in fluid dynamics relating the speed of fluid flowing from an orifice to the height of fluid above the opening. The law states that the speed of efflux of a fluid through a sharp-edged hole at the bottom of the tank filled to a depth is the same as the speed that a body would acquire in falling freely from a height , i.e. , where is the acceleration due to gravity. This expression comes from equating the kinetic energy gained, , with the potential energy lost, , and solving for . The law was discovered by the Italian scientist Evangelista Torricelli, in 1643. It was later shown to be a particular case of Bernoulli's principle.

Accidental release source terms are the mathematical equations that quantify the flow rate at which accidental releases of liquid or gaseous pollutants into the ambient environment which can occur at industrial facilities such as petroleum refineries, petrochemical plants, natural gas processing plants, oil and gas transportation pipelines, chemical plants, and many other industrial activities. Governmental regulations in many countries require that the probability of such accidental releases be analyzed and their quantitative impact upon the environment and human health be determined so that mitigating steps can be planned and implemented.

In physics and engineering, permeation is the penetration of a permeate through a solid. It is directly related to the concentration gradient of the permeate, a material's intrinsic permeability, and the materials' mass diffusivity. Permeation is modeled by equations such as Fick's laws of diffusion, and can be measured using tools such as a minipermeameter.

In nonideal fluid dynamics, the Hagen–Poiseuille equation, also known as the Hagen–Poiseuille law, Poiseuille law or Poiseuille equation, is a physical law that gives the pressure drop in an incompressible and Newtonian fluid in laminar flow flowing through a long cylindrical pipe of constant cross section. It can be successfully applied to air flow in lung alveoli, or the flow through a drinking straw or through a hypodermic needle. It was experimentally derived independently by Jean Léonard Marie Poiseuille in 1838 and Gotthilf Heinrich Ludwig Hagen, and published by Poiseuille in 1840–41 and 1846. The theoretical justification of the Poiseuille law was given by George Stokes in 1845.

In fluid dynamics the Borda–Carnot equation is an empirical description of the mechanical energy losses of the fluid due to a (sudden) flow expansion. It describes how the total head reduces due to the losses. This is in contrast with Bernoulli's principle for dissipationless flow, where the total head is a constant along a streamline. The equation is named after Jean-Charles de Borda (1733–1799) and Lazare Carnot (1753–1823).

In a nozzle or other constriction, the discharge coefficient is the ratio of the actual discharge to the ideal discharge, i.e., the ratio of the mass flow rate at the discharge end of the nozzle to that of an ideal nozzle which expands an identical working fluid from the same initial conditions to the same exit pressures.

The theory of sonics is a branch of continuum mechanics which describes the transmission of mechanical energy through vibrations. The birth of the theory of sonics is the publication of the book A treatise on transmission of power by vibrations in 1918 by the Romanian scientist Gogu Constantinescu.

ONE of the fundamental problems of mechanical engineering is that of transmitting energy found in nature, after suitable transformation, to some point at which can be made available for performing useful work. The methods of transmitting power known and practised by engineers are broadly included in two classes: mechanical including hydraulic, pneumatic and wire rope methods; and electrical methods....According to the new system, energy is transmitted from one point to another, which may be at a considerable distance, by means of impressed variations of pressure or tension producing longitudinal vibrations in solid, liquid or gaseous columns. The energy is transmitted by periodic changes of pressure and volume in the longitudinal direction and may be described as wave transmission of power, or mechanical wave transmission. – Gogu Constantinescu

Flow conditioning ensures that the "real world" environment closely resembles the "laboratory" environment for proper performance of inferential flowmeters like orifice, turbine, coriolis, ultrasonic etc.

Isentropic nozzle flow describes the movement of a gas or fluid through a narrowing opening without an increase or decrease in entropy.

<span class="mw-page-title-main">High pressure jet</span>

A high pressure jet is a stream of pressurized fluid that is released from an environment at a significantly higher pressure than ambient pressure from a nozzle or orifice, due to operational or accidental release. In the field of safety engineering, the release of toxic and flammable gases has been the subject of many R&D studies because of the major risk that they pose to the health and safety of workers, equipment and environment. Intentional or accidental release may occur in an industrial settings like natural gas processing plants, oil refineries and hydrogen storage facilities.

References

Notes

  1. Cunningham 1951 first drew attention to the fact that choked flow will not occur across a standard, thin, square-edged orifice. [12] The mass flow rate through the orifice continues to increase as the downstream pressure is lowered to a perfect vacuum, though the mass flow rate increases slowly as the downstream pressure is reduced below the critical pressure.
  2. 1 2 ISO 5167-2 uses the terms (2.8-D/25.4) and (25.4/D) - which both convert D into inches - because in that one clause of the standard, 5.3.2.1, D is in millimetres. This article presents D in metres throughout, so the terms are (2.8-D/0.0254) and (0.0254/D).
  3. ASME MFC-3M-2004 Sec. 2-4.3.2.2 stipulates a minimum of 0.8

Citations

  1. Linford 1961, pp. 85–86.
  2. Miller 1996, pp. 7.1–7.3.
  3. 1 2 3 4 ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements. International Organization for Standardization (ISO). 1 March 2003.
  4. Experimental Fluid Mechanics, Reader-Harris, ISBN 978-3-319-16879-1, 2015 edition, page 63, equation 2.13
  5. 1 2 3 Miller 1996.
  6. "Orifice Plates for Flow Measurement & Flow Restriction" . Retrieved 1 February 2014.
  7. Flow of Fluids Through Valves, Fittings and Pipe. Ipswich: Crane. 1988. pp. 2–14.
  8. 1 2 Lecture, University of Sydney Archived 2007-05-29 at the Wayback Machine
  9. 1 2 3 Perry & Green 1984.
  10. 1 2 3 Handbook of Chemical Hazard Analysis Procedures, Appendix B, Federal Emergency Management Agency, U.S. Dept. of Transportation, and U.S. Environmental Protection Agency, 1989. Handbook of Chemical Hazard Analysis, Appendix B Click on PDF icon, wait and then scroll down to page 394 of 520 PDF pages.
  11. 1 2 Risk Management Program Guidance For Offsite Consequence Analysis, U.S. EPA publication EPA-550-B-99-009, April 1999.   Guidance for Offsite Consequence Analysis Archived 2006-02-24 at the Wayback Machine
  12. Cunningham 1951, pp. 625–638.
  13. Section 3 -- Choked Flow
  14. Methods For The Calculation Of Physical Effects Due To Releases Of Hazardous Substances (Liquids and Gases), PGS2 CPR 14E, Chapter 2, The Netherlands Organization Of Applied Scientific Research, The Hague, 2005. PGS2 CPR 14E Archived 2007-08-09 at the Wayback Machine
  15. Bean 1983.
  16. 1 2 3 4 5 6 ISO 5167-2:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates. International Organization for Standardization (ISO). 1 March 2003.

Sources

  • Bean, Howard S., ed. (1983). Fluid Meters (6th ed.). The American Society of Mechanical Engineers (ASME).
  • Cunningham, R.G. (1951). "Orifice Meters with Supercritical Compressible Flow". Trans. ASME. 73: 625–638.
  • Linford, A (1961). Flow Measurement & Meters (2nd ed.). London: E. & F. N. Spon.
  • Miller, Richard W (1996). Flow Measurement Engineering Handbook. New York: McGraw-Hill. ISBN   978-0-07-042366-4.
  • Perry, Robert H.; Green, Don W. (1984). Perry's Chemical Engineers' Handbook (Sixth ed.). McGraw Hill. ISBN   978-0-07-049479-4.

Online Tools