Proton exchange membrane electrolysis

Last updated
Proton exchange membrane electrolysis
PEMelectrolysis.jpg
Diagram of PEM electrolysis reactions.
Typical Materials
Type of Electrolysis:PEM Electrolysis
Style of membrane/diaphragmSolid polymer
Bipolar/separator plate materialTitanium or gold and
platinum coated titanium
Catalyst material on the anodeIridium
Catalyst material on the cathodePlatinum
Anode PTL materialTitanium
Cathode PTL materialCarbon paper/carbon fleece
State-of-the-art Operating Ranges
Cell temperature50-80°C [1]
Stack pressure<30 bar [1]
Current density0.6-10.0 A/cm2 [1] [2]
Cell voltage1.75-2.20 V [1]
Power densityto 4.4 W/cm2 [1]
Part-load range0-10% [1]
Specific energy consumption stack4.2-5.6 kWh/Nm3 [1]
Specific energy consumption system4.5-7.5 kWh/Nm3 [1]
Cell voltage efficiency57-69% [1]
System hydrogen production rate30 Nm3/h [1]
Lifetime stack<20,000 h [1]
Acceptable degradation rate<14 μV/h [1]
System lifetime10-20 y [1]

Proton exchange membrane(PEM) electrolysis is the electrolysis of water in a cell equipped with a solid polymer electrolyte (SPE) [3] that is responsible for the conduction of protons, separation of product gases, and electrical insulation of the electrodes. The PEM electrolyzer was introduced to overcome the issues of partial load, low current density, and low pressure operation currently plaguing the alkaline electrolyzer. [4] [1] It involves a proton-exchange membrane.

Contents

Electrolysis of water is an important technology for the production of hydrogen to be used as an energy carrier. With fast dynamic response times, large operational ranges, and high efficiencies, water electrolysis is a promising technology for energy storage coupled with renewable energy sources. In terms of sustainability and environmental impact, PEM electrolysis is considered as a promising technique for high purity and efficient hydrogen production since it emits only oxygen as a by-product without any carbon emissions. [5] The IEA said in 2022 that more effort was needed. [6]

History

The use of a PEM for electrolysis was first introduced in the 1960s by General Electric, developed to overcome the drawbacks to the alkaline electrolysis technology. [7] The initial performances yielded 1.0 A/cm2 at 1.88 V which was, compared to the alkaline electrolysis technology of that time, very efficient. In the late 1970s the alkaline electrolyzers were reporting performances around 0.215 A/cm2 at 2.06 V, [8] thus prompting a sudden interest in the late 1970s and early 1980s in polymer electrolytes for water electrolysis. PEM water electrolysis technology is similar to PEM fuel cell technology, where solid poly-sulfonated membranes, such as nafion, fumapem, were used as a electrolyte (proton conductor). [9]

A thorough review of the historical performance from the early research to that of today can be found in chronological order with many of the operating conditions in the 2013 review by Carmo et al. [1]

Advantages

One of the largest advantages to PEM electrolysis is its ability to operate at high current densities. [1] This can result in reduced operational costs, especially for systems coupled with very dynamic energy sources such as wind and solar, where sudden spikes in energy input would otherwise result in uncaptured energy. The polymer electrolyte allows the PEM electrolyzer to operate with a very thin membrane (~100-200 μm) while still allowing high pressures, resulting in low ohmic losses, primarily caused by the conduction of protons across the membrane (0.1 S/cm) and a compressed hydrogen output. [10]

The polymer electrolyte membrane, due to its solid structure, exhibits a low gas crossover rate resulting in very high product gas purity. [1] Maintaining a high gas purity is important for storage safety and for the direct usage in a fuel cell. The safety limits for H2 in O2 are at standard conditions 4  mol-% H2 in O2. [11]

Science

An electrolyzer is an electrochemical device to convert electricity and water into hydrogen and oxygen, these gases can then be used as a means to store energy for later use. This use can range from electrical grid stabilization from dynamic electrical sources such as wind turbines and solar cells to localized hydrogen production as a fuel for fuel cell vehicles. The PEM electrolyzer utilizes a solid polymer electrolyte (SPE) to conduct protons from the anode to the cathode while insulating the electrodes electrically. Under standard conditions the enthalpy required for the decomposition of water is 285.9 kJ/mol. A portion of the required energy for a sustained electrolysis reaction is supplied by thermal energy and the remainder is supplied through electrical energy. [12]

Reactions

The actual value for open circuit voltage of an operating electrolyzer will lie between the 1.23 V and 1.48 V depending on how the cell/stack design utilizes the thermal energy inputs. This is however quite difficult to determine or measure because an operating electrolyzer also experiences other voltage losses from internal electrical resistances, proton conductivity, mass transport through the cell and catalyst utilization to name a few.

Anode reaction

The half reaction taking place on the anode side of a PEM electrolyzer is commonly referred to as the Oxygen Evolution Reaction (OER). Here the liquid water reactant is supplied to catalyst where the supplied water is oxidized to oxygen, protons and electrons.

Cathode reaction

The half reaction taking place on the cathode side of a PEM electrolyzer is commonly referred to as the Hydrogen Evolution Reaction (HER). Here the supplied electrons and the protons that have conducted through the membrane are combined to create gaseous hydrogen.

The illustration below depicts a simplification of how PEM electrolysis works, showing the individual half-reactions together along with the complete reaction of a PEM electrolyzer. In this case the electrolyzer is coupled with a solar panel for the production of hydrogen, however the solar panel could be replaced with any source of electricity.

Diagram of PEM electrolyzer cell and the basic principles of operation. PEM Elektrolyse 5.gif
Diagram of PEM electrolyzer cell and the basic principles of operation.

Second law of thermodynamics

As per the second law of thermodynamics the enthalpy of the reaction is:

Where is the Gibbs free energy of the reaction, is the temperature of the reaction and is the change in entropy of the system.

The overall cell reaction with thermodynamic energy inputs then becomes:

The thermal and electrical inputs shown above represent the minimum amount of energy that can be supplied by electricity in order to obtain an electrolysis reaction. Assuming that the maximum amount of heat energy (48.6 kJ/mol) is supplied to the reaction, the reversible cell voltage can be calculated.

Open circuit voltage (OCV)

where is the number of electrons and is Faraday's constant. The calculation of cell voltage assuming no irreversibilities exist and all of the thermal energy is utilized by the reaction is referred to as the lower heating value (LHV). The alternative formulation, using the higher heating value (HHV) is calculated assuming that all of the energy to drive the electrolysis reaction is supplied by the electrical component of the required energy which results in a higher reversible cell voltage. When using the HHV the voltage calculation is referred to as the thermoneutral voltage.

Voltage losses

The performance of electrolysis cells, like fuel cells, is typically compared through polarization curves, which are obtained by plotting cell voltages against current densities. The primary sources of increased voltage in a PEM electrolyzer (the same also applies for PEM fuel cells) can be categorized into three main areas, Ohmic losses, activation losses and mass transport losses. Due to the reversal of operation between a PEM fuel cell and a PEM electrolyzer, the degree of impact for these various losses is different between the two processes. [1]

A PEM electrolysis system's performance can be compared by plotting overpotential versus cell current density. This essentially results in a curve that represents the power per square centimeter of cell area required to produce hydrogen and oxygen. Conversely to the PEM fuel cell, the better the PEM electrolyzer the lower the cell voltage at a given current density. The figure below is the result of a simulation from the Forschungszentrum Jülich of a 25 cm2 single cell PEM electrolyzer under thermoneutral operation depicting the primary sources of voltage loss and their contributions for a range of current densities.

Polarization curve depicting the various losses attributed to PEM electrolysis cell operation. PEM electrolysis loss breakdown.pdf
Polarization curve depicting the various losses attributed to PEM electrolysis cell operation.

Ohmic losses

Ohmic losses are an electrical overpotential introduced to the electrolysis process by the internal resistance of the cell components. This loss then requires an additional voltage to maintain the electrolysis reaction, the prediction of this loss follows Ohm's law and holds a linear relationship to the current density of the operating electrolyzer.

The energy loss due to the electrical resistance is not entirely lost. The voltage drop due to resistivity is associated with the conversion the electrical energy to heat energy through a process known as Joule heating. Much of this heat energy is carried away with the reactant water supply and lost to the environment, however a small portion of this energy is then recaptured as heat energy in the electrolysis process. The amount of heat energy that can be recaptured is dependent on many aspects of system operation and cell design.

The Ohmic losses due to the conduction of protons contribute to the loss of efficiency which also follows Ohm's law, however without the Joule heating effect. The proton conductivity of the PEM is very dependent on the hydration, temperature, heat treatment, and ionic state of the membrane. [13]

Faradaic losses and crossover

Faradaic losses describe the efficiency losses that are correlated to the current, that is supplied without leading to hydrogen at the cathodic gas outlet. The produced hydrogen and oxygen can permeate across the membrane, referred to as crossover. [13] Mixtures of both gases at the electrodes result. At the cathode, oxygen can be catalytically reacted with hydrogen on the platinum surface of the cathodic catalyst. At the anode, hydrogen and oxygen do not react at the iridium oxide catalyst. [13] Thus, safety hazards due to explosive anodic mixtures hydrogen in oxygen can result. The supplied energy for the hydrogen production is lost, when hydrogen is lost due to the reaction with oxygen at the cathode and permeation from the cathode across the membrane to the anode corresponds. Hence, the ratio of the amount of lost and produced hydrogen determines the faradaic losses. At pressurized operation of the electrolyzer, the crossover and the correlated faradaic efficiency losses increase. [13]

Hydrogen compression during water electrolysis

Hydrogen evolution due to pressurized electrolysis is comparable to an isothermal compression process, which is in terms of efficiency preferable compared to mechanical isotropic compression. [13] However, the contributions of the aforementioned faradaic losses increase with operating pressures. Thus, in order to produce compressed hydrogen, the in-situ compression during electrolysis and subsequent compression of the gas have to be pondered under efficiency considerations.

System operation

PEM high pressure electrolyzer system PEM high pressure electrolyser.jpg
PEM high pressure electrolyzer system

The ability of the PEM electrolyzer to operate, not only under highly dynamic conditions but also in part-load and overload conditions is one of the reasons for the recently renewed interest in this technology. The demands of an electrical grid are relatively stable and predictable, however when coupling these to energy sources such as wind and solar, the demand of the grid rarely matches the generation of renewable energy. This means energy produced from renewable sources such as wind and solar benefit by having a buffer, or a means of storing off-peak energy. As of 2021, the largest PEM electrolyzer is 20 MW. [14]

PEM efficiency

When determining the electrical efficiency of PEM electrolysis, the HHV can be used. [15] This is because the catalyst layer interacts with water as steam. As the process operates at 80 °C for PEM electrolysers the waste heat can be redirected through the system to create the steam, resulting in a higher overall electrical efficiency. The LHV must be used for alkaline electrolysers as the process within these electrolysers requires water in liquid form and uses alkalinity to facilitate the breaking of the bond holding the hydrogen and oxygen atoms together. The lower heat value must also be used for fuel cells, as steam is the output rather than input.

PEM electrolysis has an electrical efficiency of about 80% in working application, in terms of hydrogen produced per unit of electricity used to drive the reaction. [16] [17] The efficiency of PEM electrolysis is expected to reach 82-86% [18] before 2030, while also maintaining durability as progress in this area continues at a pace. [19]

See also

Related Research Articles

<span class="mw-page-title-main">Electrochemical cell</span> Electro-chemical device

An electrochemical cell is a device that generates electrical energy from chemical reactions. Electrical energy can also be applied to these cells to cause chemical reactions to occur. Electrochemical cells that generate an electric current are called voltaic or galvanic cells and those that generate chemical reactions, via electrolysis for example, are called electrolytic cells.

<span class="mw-page-title-main">Fuel cell</span> Device that converts the chemical energy from a fuel into electricity

A fuel cell is an electrochemical cell that converts the chemical energy of a fuel and an oxidizing agent into electricity through a pair of redox reactions. Fuel cells are different from most batteries in requiring a continuous source of fuel and oxygen to sustain the chemical reaction, whereas in a battery the chemical energy usually comes from substances that are already present in the battery. Fuel cells can produce electricity continuously for as long as fuel and oxygen are supplied.

<span class="mw-page-title-main">Electrolysis</span> Technique in chemistry and manufacturing

In chemistry and manufacturing, electrolysis is a technique that uses direct electric current (DC) to drive an otherwise non-spontaneous chemical reaction. Electrolysis is commercially important as a stage in the separation of elements from naturally occurring sources such as ores using an electrolytic cell. The voltage that is needed for electrolysis to occur is called the decomposition potential. The word "lysis" means to separate or break, so in terms, electrolysis would mean "breakdown via electricity."

A regenerative fuel cell or reverse fuel cell (RFC) is a fuel cell run in reverse mode, which consumes electricity and chemical B to produce chemical A. By definition, the process of any fuel cell could be reversed. However, a given device is usually optimized for operating in one mode and may not be built in such a way that it can be operated backwards. Standard fuel cells operated backwards generally do not make very efficient systems unless they are purpose-built to do so as with high-pressure electrolysers, regenerative fuel cells, solid-oxide electrolyser cells and unitized regenerative fuel cells.

<span class="mw-page-title-main">Proton-exchange membrane fuel cell</span> Power generation technology

Proton-exchange membrane fuel cells (PEMFC), also known as polymer electrolyte membrane (PEM) fuel cells, are a type of fuel cell being developed mainly for transport applications, as well as for stationary fuel-cell applications and portable fuel-cell applications. Their distinguishing features include lower temperature/pressure ranges and a special proton-conducting polymer electrolyte membrane. PEMFCs generate electricity and operate on the opposite principle to PEM electrolysis, which consumes electricity. They are a leading candidate to replace the aging alkaline fuel-cell technology, which was used in the Space Shuttle.

A proton-exchange membrane, or polymer-electrolyte membrane (PEM), is a semipermeable membrane generally made from ionomers and designed to conduct protons while acting as an electronic insulator and reactant barrier, e.g. to oxygen and hydrogen gas. This is their essential function when incorporated into a membrane electrode assembly (MEA) of a proton-exchange membrane fuel cell or of a proton-exchange membrane electrolyser: separation of reactants and transport of protons while blocking a direct electronic pathway through the membrane.

<span class="mw-page-title-main">Electrolysis of water</span> Electricity-induced chemical reaction

Electrolysis of water is using electricity to split water into oxygen and hydrogen gas by electrolysis. Hydrogen gas released in this way can be used as hydrogen fuel, but must be kept apart from the oxygen as the mixture would be extremely explosive. Separately pressurised into convenient 'tanks' or 'gas bottles', hydrogen can be used for oxyhydrogen welding and other applications, as the hydrogen / oxygen flame can reach approximately 2,800°C.

Hydrogen gas is produced by several industrial methods. Nearly all of the world's current supply of hydrogen is created from fossil fuels. Most hydrogen is gray hydrogen made through steam methane reforming. In this process, hydrogen is produced from a chemical reaction between steam and methane, the main component of natural gas. Producing one tonne of hydrogen through this process emits 6.6–9.3 tonnes of carbon dioxide. When carbon capture and storage is used to remove a large fraction of these emissions, the product is known as blue hydrogen.

<span class="mw-page-title-main">Membrane electrode assembly</span>

A membrane electrode assembly (MEA) is an assembled stack of proton-exchange membranes (PEM) or alkali anion exchange membrane (AAEM), catalyst and flat plate electrode used in fuel cells and electrolyzers.

<span class="mw-page-title-main">High-pressure electrolysis</span>

High-pressure electrolysis (HPE) is the electrolysis of water by decomposition of water (H2O) into oxygen (O2) and hydrogen gas (H2) due to the passing of an electric current through the water. The difference with a standard proton exchange membrane electrolyzer is the compressed hydrogen output around 12–20 megapascals (120–200 bar) at 70 °C. By pressurising the hydrogen in the electrolyser the need for an external hydrogen compressor is eliminated, the average energy consumption for internal differential pressure compression is around 3%.

The Glossary of fuel cell terms lists the definitions of many terms used within the fuel cell industry. The terms in this fuel cell glossary may be used by fuel cell industry associations, in education material and fuel cell codes and standards to name but a few.

<span class="mw-page-title-main">Solid oxide electrolyzer cell</span> Type of fuel cell

A solid oxide electrolyzer cell (SOEC) is a solid oxide fuel cell that runs in regenerative mode to achieve the electrolysis of water by using a solid oxide, or ceramic, electrolyte to produce hydrogen gas and oxygen. The production of pure hydrogen is compelling because it is a clean fuel that can be stored, making it a potential alternative to batteries, methane, and other energy sources. Electrolysis is currently the most promising method of hydrogen production from water due to high efficiency of conversion and relatively low required energy input when compared to thermochemical and photocatalytic methods.

Membraneless Fuel Cells convert stored chemical energy into electrical energy without the use of a conducting membrane as with other types of Fuel Cells. In Laminar Flow Fuel Cells (LFFC) this is achieved by exploiting the phenomenon of non-mixing laminar flows where the interface between the two flows works as a proton/ion conductor. The interface allows for high diffusivity and eliminates the need for costly membranes. The operating principles of these cells mean that they can only be built to millimeter-scale sizes. The lack of a membrane means they are cheaper but the size limits their use to portable applications which require small amounts of power.

<span class="mw-page-title-main">Alkaline anion-exchange membrane fuel cell</span>

An alkaline anion-exchange membrane fuel cell (AAEMFC), also known as anion-exchange membrane fuel cells (AEMFCs), alkaline membrane fuel cells (AMFCs), hydroxide-exchange membrane fuel cells (HEMFCs), or solid alkaline fuel cells (SAFCs) is a type of alkaline fuel cell that uses an anion-exchange membrane to separate the anode and cathode compartments.

Hydrogenics is a developer and manufacturer of hydrogen generation and fuel cell products based on water electrolysis and proton-exchange membrane (PEM) technology. Hydrogenics is divided into two business units: OnSite Generation and Power Systems. Onsite Generation is headquartered in Oevel, Belgium and had 73 full-time employees as of December 2013. Power Systems is based in Mississauga, Ontario, Canada, with a satellite facility in Gladbeck, Germany. It had 62 full-time employees as of December 2013. Hydrogenics maintains operations in Belgium, Canada and Germany with satellite offices in the United States, Indonesia, Malaysia and Russia.

<span class="mw-page-title-main">Pulse electrolysis</span> Pulse Electrolysis

Pulse electrolysis is an alternate electrolysis method that utilises a pulsed direct current to initiate non-spontaneous chemical reactions. Also known as pulsed direct current (PDC) electrolysis, the increased number of variables that it introduces to the electrolysis method can change the application of the current to the electrodes and the resulting outcome. This varies from direct current (DC) electrolysis, which only allows the variation of one value, the voltage applied. By utilising conventional pulse width modulation (PMW), multiple dependent variables can be altered, including the type of waveform, typically a rectangular pulse wave, the duty cycle, and the frequency. Currently, there has been a focus on theoretical and experimental research into PDC electrolysis in terms of the electrolysis of water to produce hydrogen. Past research has demonstrated that there is a possibility it can result in a higher electrical efficiency in comparison to DC electrolysis. This would allow electrolysis procedures to produce greater volumes of hydrogen with a reduced electrical energy consumption. Although theoretical research has made large promise for the efficiencies and benefits of utilising pulse electrolysis, it has many contradictions including a common issue that it is difficult to replicate the successes of patents experimentally and produces its own negative effects on the electrolyser.

<span class="mw-page-title-main">Reversible solid oxide cell</span>

A reversible solid oxide cell (rSOC) is a solid-state electrochemical device that is operated alternatively as a solid oxide fuel cell (SOFC) and a solid oxide electrolysis cell (SOEC). Similarly to SOFCs, rSOCs are made of a dense electrolyte sandwiched between two porous electrodes. Their operating temperature ranges from 600°C to 900°C, hence they benefit from enhanced kinetics of the reactions and increased efficiency with respect to low-temperature electrochemical technologies.

Hydrogen evolution reaction (HER) is a chemical reaction that yields H2. The conversion of protons to H2 requires reducing equivalents and usually a catalyst. In nature, HER is catalyzed by hydrogenase enzymes. Commercial electrolyzers typically employ supported platinum as the catalyst at the anode of the electrolyzer. HER is useful for producing hydrogen gas, providing a clean-burning fuel. HER, however, can also be an unwelcome side reaction that competes with other reductions such as nitrogen fixation, or electrochemical reduction of carbon dioxide or chrome plating.

<span class="mw-page-title-main">Anion exchange membrane electrolysis</span> Splitting of water using a semipermeable membrane

Anion exchange membrane(AEM) electrolysis is the electrolysis of water that utilises a semipermeable membrane that conducts hydroxide ions (OH) called an anion exchange membrane. Like a proton-exchange membrane (PEM), the membrane separates the products, provides electrical insulation between electrodes, and conducts ions. Unlike PEM, AEM conducts hydroxide ions. The major advantage of AEM water electrolysis is that a high-cost noble metal catalyst is not required, low-cost transition metal catalyst can be used instead. AEM electrolysis is similar to alkaline water electrolysis, which uses a non-ion-selective separator instead of an anion-exchange membrane.

References

  1. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Carmo, M; Fritz D; Mergel J; Stolten D (2013). "A comprehensive review on PEM water electrolysis". International Journal of Hydrogen Energy. 38 (12): 4901–4934. doi:10.1016/j.ijhydene.2013.01.151.
  2. Villagra, A; Millet P (2019). "An analysis of PEM water electrolysis cells operating at elevated current densities". International Journal of Hydrogen Energy. 44 (20): 9708–9717. doi: 10.1016/j.ijhydene.2018.11.179 . S2CID   104308293.
  3. 2012 - PEM water electrolysis fundamentals
  4. "2014 - Development of water electrolysis in the European Union" (PDF). Archived from the original (PDF) on 2015-03-31. Retrieved 2014-12-03.
  5. Shiva Kumar, S.; Himabindu, V. (2019-12-01). "Hydrogen production by PEM water electrolysis – A review". Materials Science for Energy Technologies. 2 (3): 442–454. Bibcode:2019MSET....2..442S. doi: 10.1016/j.mset.2019.03.002 . ISSN   2589-2991. S2CID   141506732.
  6. "Electrolysers – Analysis". IEA. Retrieved 2023-04-30.
  7. Russell, JH; Nuttall LJ; Ficket AP (1973). "Hydrogen generation by solid polymer electrolyte water electrolysis". American Chemical Society Division of Fuel Chemistry Preprints.
  8. LeRoy, RL; Janjua MB; Renaud R; Leuenberger U (1979). "Analysis of Time-Variation Effects in Water Electrolyzers". Journal of the Electrochemical Society. 126 (10): 1674. Bibcode:1979JElS..126.1674L. doi:10.1149/1.2128775.
  9. Abdol Rahim, A. H.; Tijani, Alhassan Salami; Kamarudin, S. K.; Hanapi, S. (2016-03-31). "An overview of polymer electrolyte membrane electrolyzer for hydrogen production: Modeling and mass transport". Journal of Power Sources. 309: 56–65. Bibcode:2016JPS...309...56A. doi:10.1016/j.jpowsour.2016.01.012. ISSN   0378-7753.
  10. Slade, S; Campbell SA; Ralph TR; Walsh FC (2002). "Ionic conductivity of an extruded Nafion 1100 EW series of membranes" (PDF). Journal of the Electrochemical Society. 149 (12): A1556. Bibcode:2002JElS..149A1556S. doi:10.1149/1.1517281. S2CID   14851298.
  11. Schröder, V; Emonts B; Janßen H; Schulze HP (2004). "Explosion Limits of Hydrogen/Oxygen Mixtures at Initial Pressures up to 200 bar". Chemical Engineering & Technology. 27 (8): 847–851. doi:10.1002/ceat.200403174.
  12. Mergel, J; Carmo M; Fritz, D (2013). "Status on Technologies for Hydrogen Production by Water Electrolysis". In Stolten, D (ed.). Transition to Renewable Energy Systems. Weinheim: Wiley-VCH. ISBN   978-3-527-33239-7.
  13. 1 2 3 4 5 Schalenbach, M; Carmo M; Fritz DL; Mergel J; Stolten D (2013). "Pressurized PEM water electrolysis: Efficiency and gas crossover". International Journal of Hydrogen Energy . 38 (35): 14921–14933. doi:10.1016/j.ijhydene.2013.09.013.
  14. Collins, Leigh (27 January 2021). "World's largest green-hydrogen plant inaugurated in Canada by Air Liquide". Recharge | Latest renewable energy news. Archived from the original on 25 March 2021.
  15. Kruse, Bjørnar. "Hydrogen Status og muligheter" (PDF). bellona.org/. Bellona Norway. Retrieved 22 April 2018.
  16. Bernholz, Jan (September 13, 2018). "RWE's former, current and possible future energy storage applications" (PDF). RWE. p. 10. Total Efficiency: 70%, or 86% (usage of waste heat)
  17. "ITM – Hydrogen Refuelling Infrastructure – February 2017" (PDF). level-network.com. Archived (PDF) from the original on 17 April 2018. Retrieved 17 April 2018.[ dead link ]
  18. "Cost reduction and performance increase of PEM electrolysers" (PDF). www.fch.europa.eu. Fuel Cells and Hydrogen Joint Undertaking. Retrieved 17 April 2018.
  19. "Report and Financial Statements 30 April 2016" (PDF). www.itm-power.com. Retrieved 17 April 2018.