Uncertainties in building design and building energy assessment

Last updated

The detailed design of buildings needs to take into account various external factors, which may be subject to uncertainties. Among these factors are prevailing weather and climate; the properties of the materials used and the standard of workmanship; and the behaviour of occupants of the building. Several studies have indicated that it is the behavioural factors that are the most important among these. Methods have been developed to estimate the extent of variability in these factors and the resulting need to take this variability into account at the design stage.

Contents

Sources of uncertainty

Earlier work includes a paper by Gero and Dudnik (1978) presenting a methodology to solve the problem of designing heating, ventilation and air conditioning systems subjected to uncertain demands. Since then, other authors have shown an interest in the uncertainties that are present in building design. Ramallo-González (2013) [1] classified uncertainties in energy building assessment tools in three different groups:

  1. Environmental. Uncertainty in weather prediction under changing climate; and uncertain weather data information due to the use of synthetic weather data files: (1) use of synthetic years that do not represent a real year, and (2) use of a synthetic year that has not been generated from recorded data in the exact location of the project but in the closest weather station.
  2. Workmanship and quality of building elements. Differences between the design and the real building: Conductivity of thermal bridges, conductivity of insulation, value of infiltration (air leakage), or U-values of walls and windows.
  3. Behavioural. All other parameters linked to human behaviour, e.g. opening of doors and windows, use of appliances, occupancy patterns or cooking habits. [2]

Weather and climate

Climate change

Buildings have long life spans: for example, in England and Wales, around 40% of the office blocks existing in 2004 were built before 1940 (30% if considered by floor area), [3] and 38.9% of English dwellings in 2007 were built before 1944. [4] This long life span makes buildings likely to operate with climates that might change due to global warming. De Wilde and Coley (2012) showed how important is to design buildings that take into consideration climate change and that are able to perform well in future weathers. [5]

Weather data

The use of synthetic weather data files may introduce further uncertainty. Wang et al. (2005) showed the impact that uncertainties in weather data (among others) may cause in energy demand calculations. [6] The deviation in calculated energy use due to variability in the weather data were found to be different in different locations from a range of (-0.5% to 3%) in San Francisco to a range of (-4% to 6%) in Washington D.C. The ranges were calculated using a Typical Meteorological Year (TMY) as the reference.

The spatial resolution of weather data files was the concern covered by Eames et al. (2011). [7] Eames showed how a low spatial resolution of weather data files can be the cause of disparities of up to 40% in the heating demand. The reason is that this uncertainty is not understood as an aleatory parameter but as an epistemic uncertainty that can be solved with the appropriate improvement of the data resources or with specific weather data acquisition for each project.

Building materials and workmanship

A large study was carried out by Leeds Metropolitan University at Stamford Brook in England. This project saw 700 dwellings built to high efficiency standards. [8] The results of this project show a significant gap between the energy used expected before construction and the actual energy use once the house is occupied. The workmanship is analysed in this work. The authors emphasise the importance of thermal bridges that were not considered for the calculations, and that the thermal bridges that have the largest impact on the final energy use are those originated by the internal partitions that separate dwellings. The dwellings that were monitored in use in this study show a large difference between the real energy use and that estimated using the UK Standard Assessment Procedure (SAP), with one of them giving +176% of the expected value when in use.

Hopfe has published several papers concerning uncertainties in building design. A 2007 publication [9] looks into uncertainties of types 2 and 3. In this work the uncertainties are defined as normal distributions. The random parameters are sampled to generate 200 tests that are sent to the simulator (VA114), the results from which will be analysed to check the uncertainties with the largest impact on the energy calculations. This work showed that the uncertainty in the value used for infiltration is the factor that is likely to have the largest influence on cooling and heating demands. De Wilde and Tian (2009) agreed with Hopfe on the impact of uncertainties in infiltration upon energy calculations, but also introduced other factors.

The work of Schnieders and Hermelink (2006) [10] showed a substantial variability in the energy demands of low-energy buildings designed under the same (Passivhaus) specification.

Occupant behaviour

Blight and Coley (2012) [11] showed that substantial variability in energy use can be occasioned due to variance in occupant behaviour, including the use of windows and doors. Their paper also demonstrated that their method of modelling occupants’ behaviour accurately reproduces actual behavioural patterns of inhabitants. This modelling method was the one developed by Richardson et al. (2008), [12] using the Time-Use Survey (TUS) of the United Kingdom as a source for real behaviour of occupants, based on the activity of more than 6000 occupants as recorded in 24-hour diaries with a 10-minute resolution. Richardson's paper shows how the tool is able to generate behavioural patterns that correlate with the real data obtained from the TUS.

Multifactorial studies

In the work of Pettersen (1994), uncertainties of group 2 (workmanship and quality of elements) and group 3 (behaviour) of the previous grouping were considered. [13] This work shows how important occupants’ behaviour is on the calculation of the energy demand of a building. Pettersen showed that the total energy use follows a normal distribution with a standard deviation of around 7.6% when the uncertainties due to occupants are considered, and of around 4.0% when considering those generated by the properties of the building elements.

Wang et al. (2005) showed that deviations in energy demand due to local variability in weather data were smaller than the ones due to operational parameters linked with occupants’ behaviour. For those, the ranges were (-29% to 79%) for San Francisco and (-28% to 57%) for Washington D.C. The conclusion of this paper is that occupants will have a larger impact in energy calculations than the variability between synthetically generated weather data files.

Another study performed by de Wilde and Wei Tian (2009) [14] compared the impact of most of the uncertainties affecting building energy calculations, including uncertainties in: weather, U-Value of windows, and other variables related with occupants’ behaviour (equipment and lighting), and taking into account climate change. De Wilde and Tian used a two-dimensional Monte Carlo simulation analysis to generate a database obtained with 7280 runs of a building simulator. A sensitivity analysis was applied to this database to obtain the most significant factors on the variability of the energy demand calculations. Standardised regression coefficients and standardised rank regression coefficients were used to compare the impacts of the uncertainties. Their paper compares many of the uncertainties with a good sized database providing a realistic comparison for the scope of the sampling of the uncertainties.

See also

Related Research Articles

<span class="mw-page-title-main">Thermal mass</span> Use of thermal energy storage in building design

In building design, thermal mass is a property of the mass of a building that enables it to store heat and provide inertia against temperature fluctuations. It is sometimes known as the thermal flywheel effect. The thermal mass of heavy structural elements can be designed to work alongside a construction's lighter thermal resistance components to create energy efficient buildings.

<span class="mw-page-title-main">Heat recovery ventilation</span> Method of reusing thermal energy in a building

Heat recovery ventilation (HRV), also known as mechanical ventilation heat recovery (MVHR), is an energy recovery ventilation system that operates between two air sources at different temperatures. It's a method that is used to reduce the heating and cooling demands of buildings. By recovering the residual heat in the exhaust gas, the fresh air introduced into the air conditioning system is preheated, and the fresh air's enthalpy is reduced before it enters the room, or the air cooler of the air conditioning unit performs heat and moisture treatment. A typical heat recovery system in buildings comprises a core unit, channels for fresh and exhaust air, and blower fans. Building exhaust air is used as either a heat source or heat sink, depending on the climate conditions, time of year, and requirements of the building. Heat recovery systems typically recover about 60–95% of the heat in the exhaust air and have significantly improved the energy efficiency of buildings.

<span class="mw-page-title-main">Heating degree day</span> Sum of temperature values

Heating degree day (HDD) is a measurement designed to quantify the demand for energy needed to heat a building. HDD is derived from measurements of outside air temperature. The heating requirements for a given building at a specific location are considered to be directly proportional to the number of HDD at that location.

<span class="mw-page-title-main">Building science</span>

Building science is the science and technology-driven collection of knowledge in order to provide better indoor environmental quality (IEQ), energy-efficient built environments, and occupant comfort and satisfaction. Building physics, architectural science, and applied physics are terms used for the knowledge domain that overlaps with building science. In building science, the methods used in natural and hard sciences are widely applied, which may include controlled and quasi-experiments, randomized control, physical measurements, remote sensing, and simulations. On the other hand, methods from social and soft sciences, such as case study, interviews & focus group, observational method, surveys, and experience sampling, are also widely used in building science to understand occupant satisfaction, comfort, and experiences by acquiring qualitative data. One of the recent trends in building science is a combination of the two different methods. For instance, it is widely known that occupants’ thermal sensation and comfort may vary depending on their sex, age, emotion, experiences, etc. even in the same indoor environment. Despite the advancement in data extraction and collection technology in building science, objective measurements alone can hardly represent occupants' state of mind such as comfort and preference. Therefore, researchers are trying to measure both physical contexts and understand human responses to figure out complex interrelationships.

<span class="mw-page-title-main">Building insulation</span> Material to reduce heat transfer in structures

Building insulation is material used in a building to reduce the flow of thermal energy. While the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation, fire insulation, and impact insulation. Often an insulation material will be chosen for its ability to perform several of these functions at once.

Thermal comfort is the condition of mind that expresses satisfaction with the thermal environment and is assessed by subjective evaluation. The human body can be viewed as a heat engine where food is the input energy. The human body will release excess heat into the environment, so the body can continue to operate. The heat transfer is proportional to temperature difference. In cold environments, the body loses more heat to the environment and in hot environments the body does not release enough heat. Both the hot and cold scenarios lead to discomfort. Maintaining this standard of thermal comfort for occupants of buildings or other enclosures is one of the important goals of HVAC design engineers.

<span class="mw-page-title-main">Thermal bridge</span>

A thermal bridge, also called a cold bridge, heat bridge, or thermal bypass, is an area or component of an object which has higher thermal conductivity than the surrounding materials, creating a path of least resistance for heat transfer. Thermal bridges result in an overall reduction in thermal resistance of the object. The term is frequently discussed in the context of a building's thermal envelope where thermal bridges result in heat transfer into or out of conditioned space.

<span class="mw-page-title-main">Energy audit</span> Inspection, survey and analysis of energy flows in a building

An energy audit is an inspection survey and an analysis of energy flows for energy conservation in a building. It may include a process or system to reduce the amount of energy input into the system without negatively affecting the output. In commercial and industrial real estate, an energy audit is the first step in identifying opportunities to reduce energy expense and carbon footprint.

Energy Management Software (EMS) is a general term and category referring to a variety of energy-related software applications which may provide utility bill tracking, real-time metering, building HVAC and lighting control systems, building simulation and modeling, carbon and sustainability reporting, IT equipment management, demand response, and/or energy audits. Managing energy can require a system of systems approach.

OptiY is a design environment software that provides modern optimization strategies and state of the art probabilistic algorithms for uncertainty, reliability, robustness, sensitivity analysis, data-mining and meta-modeling.

<span class="mw-page-title-main">Underfloor air distribution</span>

Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings as part of the design of a HVAC system. UFAD systems use an underfloor supply plenum located between the structural concrete slab and a raised floor system to supply conditioned air to supply outlets, located at or near floor level within the occupied space. Air returns from the room at ceiling level or the maximum allowable height above the occupied zone.

<span class="mw-page-title-main">Variable renewable energy</span> Class of renewable energy sources

Variable renewable energy (VRE) or intermittent renewable energy sources (IRES) are renewable energy sources that are not dispatchable due to their fluctuating nature, such as wind power and solar power, as opposed to controllable renewable energy sources, such as dammed hydroelectricity or biomass, or relatively constant sources, such as geothermal power.

The House Energy Rating (HER) or House Energy Rating Scheme (HERS) are worldwide standard measures of comparison by which one can evaluate the energy efficiency of a new or an existing building. The comparison is generally done for energy requirements for heating and cooling of indoor space. The energy is the main criterion considered by any international building energy rating scheme but there are some other important factors such as production of greenhouse gases emission, indoor environment quality, cost efficiency and thermal comfort, which are considered by some schemes. Basically, the energy rating of a residential building provides detailed information on the energy consumption and the relative energy efficiency of the building. Hence, HERs inform consumers about the relative energy efficiency of homes and encourage them to use this information in making their house purchase decision.

<span class="mw-page-title-main">Building performance simulation</span> Replication of aspects of building performance

Building performance simulation (BPS) is the replication of aspects of building performance using a computer-based, mathematical model created on the basis of fundamental physical principles and sound engineering practice. The objective of building performance simulation is the quantification of aspects of building performance which are relevant to the design, construction, operation and control of buildings. Building performance simulation has various sub-domains; most prominent are thermal simulation, lighting simulation, acoustical simulation and air flow simulation. Most building performance simulation is based on the use of bespoke simulation software. Building performance simulation itself is a field within the wider realm of scientific computing.

<span class="mw-page-title-main">Climate-adaptive building shell</span> Architecture that adapts to the environment

In building engineering, a climate-adaptive building shell (CABS) is a facade or roof that interacts with the variability of its environment in a dynamic way. Conventional structures have static building envelopes and therefore cannot act in response to changing weather conditions and occupant requirements. Well-designed CABS have two main functions: they contribute to energy-saving for heating, cooling, ventilation, and lighting, and they induce a positive impact on the indoor environmental quality of buildings.

A building-energy performance gap is a disparity between the energy consumption predicted in the design stage of a building and the energy use in actual operation. It can have many causes.

A performance gap is a disparity that is found between the energy use predicted and carbon emissions in the design stage of buildings and the energy use of those buildings in operation. Research in the UK suggests that actual carbon emissions from new homes can be 2.5 times the design estimates, on average. For non-domestic buildings, the gap is even higher - actual carbon emissions as much as 3.8 times the design estimates, on average.

Sensitivity analysis identifies how uncertainties in input parameters affect important measures of building performance, such as cost, indoor thermal comfort, or CO2 emissions. Input parameters for buildings fall into roughly three categories:

<span class="mw-page-title-main">IDA Indoor Climate and Energy</span>

IDA IndoorClimate andEnergy is a Building performance simulation (BPS) software. IDA ICE is a simulation application for the multi-zonal and dynamic study of indoor climate phenomena as well as energy use. The implemented models are state of the art, many studies show that simulation results and measured data compare well.

Linda Opal Mearns is a geographer and climate scientist specializing in climate change assessment science. Mearns is a senior scientist at the National Center for Atmospheric Research (NCAR). Mearns is the director of NCAR's Weather and Climate Impacts Assessment Science Program (WCIASP) and head of the Regional Integrated Sciences Collective (RISC). Mearns is a lead principal investigator for the North American Regional Climate Change Program (NARCCAP).

References

  1. Ramallo-González, A.P. 2013. Modelling, Simulation and Optimisation of Low-energy Buildings. PhD. University of Exeter.
  2. Rafsanjani, H.N.; Ahn, C.R.; Alahmad, M. A Review of Approaches for Sensing, Understanding, and Improving Occupancy-Related Energy-Use Behaviors in Commercial Buildings. Energies 2015, 8, 10996-11029.
  3. ODPM, 2005. Age of Commercial and Industrial Stock: Local Authority Level 2004. London: Office of the Deputy Prime Minister.
  4. CLG, 2007. English House Condition Survey 2007, Annual report. Communities and Local Government.
  5. de Wilde, P. & Coley, D., 2012. The implications of a changing climate for buildings. Building and Environment, 55, pp.1-7.
  6. Wang, W.M., Zmeureanu, R. & Rivard, H., 2005. Applying multi-objective genetic algorithms in green building design optimization. Building and Environment, 40, pp.1512-1525.
  7. Eames, M., Kershaw, T. & Coley, D., 2011. The appropriate spatial resolution of future weather files for building simulation. Journal of Building Performance Simulation, 5, pp.1-12.
  8. Wingfield, J., Bell, M., Miles-Shenton, D., South, T. & Lowe, B., 2011. Evaluating the impact of an enhanced energy performance standard on load-bearing masonry domestic construction, Understanding the gap
  9. Hopfe, C., Hensen, J., Plokker, W. & Wijsman, A., 2007. Model uncertainty and sensitivity analysis for thermal comfort prediction, Proceedings of the 12th Symposium for Building Physics. Dresden, March
  10. Schnieders, J. & Hermelink, A., 2006. CEPHEUS results: measurements and occupants’ satisfaction provide evidence for Passive Houses being an option for sustainable building. Energy Policy, 34, pp.151-171.
  11. Blight, T.S., Coley D. A., 2012 The impact of occupant behaviour on the energy consumption of low-energy dwellings, 2nd Conference on Building Energy and Environment. Boulder, USA.
  12. Richardson, I., Thomson, M. & Infield, D., 2008. A high-resolution domestic building occupancy model for energy demand simulations. Energy and Buildings, 40, pp.1560-1566.
  13. Pettersen, T.D., 1994. Variation of Energy-Consumption in Dwellings Due to Climate, Building and Inhabitants. Energy and Buildings, 21, pp.209-218.
  14. de Wilde, P. & Tian, W., 2009. Identification of key factors for uncertainty in the prediction of the thermal performance of an office building under climate change. Building Simulation, 2, pp.157-174.