A wire chamber or multi-wire proportional chamber is a type of proportional counter that detects charged particles and photons and can give positional information on their trajectory, [1] by tracking the trails of gaseous ionization. [2] The technique was an improvement over the bubble chamber particle detection method, which used photographic techniques, as it allowed high speed electronics to track the particle path.
The multi-wire chamber uses an array of wires at a positive dc voltage (anode)s, which run through a chamber with conductive walls held at a lower potential (cathode). The chamber is filled with gas, such as an argon/methane mix, so that any ionizing particle that passes through the tube will ionize surrounding gaseous atoms and produce ion pairs, consisting of positive ions and electrons. These are accelerated by the electric field across the chamber, preventing recombination; the electrons are accelerated to the anode, and the positive ions to the cathode. At the anode a phenomenon known as a Townsend avalanche occurs. This results in a measurable current flow for each original ionising event which is proportional to the ionisation energy deposited by the detected particle. By separately measuring the current pulses from each wire, the particle trajectory can be found. Adaptations of this basic design are the thin gap, resistive plate and drift chambers. The drift chamber can also be subdivided into ranges of specific use in the chamber designs known as time projection, microstrip gas, and those types of detectors that use silicon. [3] [4]
In 1968, Georges Charpak, while at the European Organization for Nuclear Research (CERN), invented and developed the multi-wire proportional chamber (MWPC). This invention resulted in him winning the Nobel Prize for Physics in 1992. The chamber was an advancement of the earlier bubble chamber rate of detection of only one or two particles every second to 1000 particle detections every second. The MWPC produced electronic signals from particle detection, allowing scientists to examine data via computers. [5] [6] [7] The multi-wire chamber is a development of the spark chamber. [8]
In a typical experiment, the chamber contains a mixture of these gases: [2]
The chamber could also be filled with:
For high-energy physics experiments, it is used to observe a particle's path. For a long time, bubble chambers were used for this purpose, but with the improvement of electronics, it became desirable to have a detector with fast electronic read-out. (In bubble chambers, photographic exposures were made and the resulting printed photographs were then examined.) A wire chamber is a chamber with many parallel wires, arranged as a grid and put on high voltage, with the metal casing being on ground potential. As in the Geiger counter, a particle leaves a trace of ions and electrons, which drift toward the case or the nearest wire, respectively. By marking off the wires which had a pulse of current, one can see the particle's path.
The chamber has a very good relative time resolution, good positional accuracy, and self-triggered operation (Ferbel 1977). [12]
The development of the chamber enabled scientists to study the trajectories of particles with much-improved precision, and also for the first time to observe and study the rarer interactions that occur through particle interaction.
If one also precisely measures the timing of the current pulses of the wires and takes into account that the ions need some time to drift to the nearest wire, one can infer the distance at which the particle passed the wire. This greatly increases the accuracy of the path reconstruction and is known as a drift chamber.
A drift chamber functions by balancing the loss of energy from particles caused by impacts with particles of gas with the accretion of energy created with high-energy electrical fields in use to cause the particle acceleration. [13] Design is similar to the multi-wire proportional chamber but with a greater distance between central-layer wires. [8] The detection of charged particles within the chamber is possible by the ionizing of gas particles due to the motion of the charged particle. [14]
The Fermilab detector CDF II contains a drift chamber called the Central Outer Tracker. [15] The chamber contains argon and ethane gas, and wires separated by 3.56-millimetre gaps. [16]
If two drift chambers are used with the wires of one orthogonal to the wires of the other, both orthogonal to the beam direction, a more precise detection of the position is obtained. If an additional simple detector (like the one used in a veto counter) is used to detect, with poor or null positional resolution, the particle at a fixed distance before or after the wires, a tri-dimensional reconstruction can be made and the speed of the particle deduced from the difference in time of the passage of the particle in the different parts of the detector. This setup gives us a detector called a time projection chamber (TPC).
For measuring the velocity of the electrons in a gas (drift velocity) there are special drift chambers, velocity drift chambers, which measure the drift time for a known location of ionisation.
A Geiger counter is an electronic instrument used for detecting and measuring ionizing radiation. It is widely used in applications such as radiation dosimetry, radiological protection, experimental physics and the nuclear industry.
The Geiger–Müller tube or G–M tube is the sensing element of the Geiger counter instrument used for the detection of ionizing radiation. It is named after Hans Geiger, who invented the principle in 1908, and Walther Müller, who collaborated with Geiger in developing the technique further in 1928 to produce a practical tube that could detect a number of different radiation types.
A bubble chamber is a vessel filled with a superheated transparent liquid used to detect electrically charged particles moving through it. It was invented in 1952 by Donald A. Glaser, for which he was awarded the 1960 Nobel Prize in Physics. Supposedly, Glaser was inspired by the bubbles in a glass of beer; however, in a 2006 talk, he refuted this story, although saying that while beer was not the inspiration for the bubble chamber, he did experiments using beer to fill early prototypes.
Georges Charpak (French:[ʃaʁpak]; born Jerzy Charpak, was a Polish-born French physicist who was awarded the Nobel Prize in Physics in 1992.
In experimental and applied particle physics, nuclear physics, and nuclear engineering, a particle detector, also known as a radiation detector, is a device used to detect, track, and/or identify ionizing particles, such as those produced by nuclear decay, cosmic radiation, or reactions in a particle accelerator. Detectors can measure the particle energy and other attributes such as momentum, spin, charge, particle type, in addition to merely registering the presence of the particle.
A cloud chamber, also known as a Wilson chamber, is a particle detector used for visualizing the passage of ionizing radiation.
A semiconductor detector in ionizing radiation detection physics is a device that uses a semiconductor to measure the effect of incident charged particles or photons.
The proportional counter is a type of gaseous ionization detector device used to measure particles of ionizing radiation. The key feature is its ability to measure the energy of incident radiation, by producing a detector output pulse that is proportional to the radiation energy absorbed by the detector due to an ionizing event; hence the detector's name. It is widely used where energy levels of incident radiation must be known, such as in the discrimination between alpha and beta particles, or accurate measurement of X-ray radiation dose.
In physics, a time projection chamber (TPC) is a type of particle detector that uses a combination of electric fields and magnetic fields together with a sensitive volume of gas or liquid to perform a three-dimensional reconstruction of a particle trajectory or interaction.
The ionization chamber is the simplest type of gaseous ionisation detector, and is widely used for the detection and measurement of many types of ionizing radiation, including X-rays, gamma rays, alpha particles and beta particles. Conventionally, the term "ionization chamber" refers exclusively to those detectors which collect all the charges created by direct ionization within the gas through the application of an electric field. It uses the discrete charges created by each interaction between the incident radiation and the gas to produce an output in the form of a small direct current. This means individual ionising events cannot be measured, so the energy of different types of radiation cannot be differentiated, but it gives a very good measurement of overall ionising effect.
Gaseous ionization detectors are radiation detection instruments used in particle physics to detect the presence of ionizing particles, and in radiation protection applications to measure ionizing radiation.
A straw chamber is a type of Gaseous ionization detector. It is a long tube with a wire down the center and a gas which becomes ionized when a particle passes through. A potential difference is maintained between the wire and the walls of the tube, so that once the gas is ionized electrons move in one direction and ions in the other. This produces a current which indicates that a particle has passed through the chamber.
In electromagnetism, the Townsend discharge or Townsend avalanche is an ionisation process for gases where free electrons are accelerated by an electric field, collide with gas molecules, and consequently free additional electrons. Those electrons are in turn accelerated and free additional electrons. The result is an avalanche multiplication that permits significantly increased electrical conduction through the gas. The discharge requires a source of free electrons and a significant electric field; without both, the phenomenon does not occur.
The MicroMegas detector is a gaseous particle detector and an advancement of the wire chamber. Invented in 1996 by Georges Charpak and Ioannis Giomataris, Micromegas detectors are mainly used in experimental physics, in particular in particle physics, nuclear physics and astrophysics for the detection of ionizing particles.
A gas electron multiplier (GEM) is a type of gaseous ionization detector used in nuclear and particle physics and radiation detection.
ALEPH was a particle detector at the Large Electron-Positron collider (LEP) at CERN. It was designed to explore the physics predicted by the Standard Model and to search for physics beyond it.
The gaseous detection device (GDD) is a method and apparatus for the detection of signals in the gaseous environment of an environmental scanning electron microscope (ESEM) and all scanned beam type of instruments that allow a minimum gas pressure for the detector to operate.
The ZEPLIN-III dark matter experiment attempted to detect galactic WIMPs using a 12 kg liquid xenon target. It operated from 2006 to 2011 at the Boulby Underground Laboratory in Loftus, North Yorkshire. This was the last in a series of xenon-based experiments in the ZEPLIN programme pursued originally by the UK Dark Matter Collaboration (UKDMC). The ZEPLIN-III project was led by Imperial College London and also included the Rutherford Appleton Laboratory and the University of Edinburgh in the UK, as well as LIP-Coimbra in Portugal and ITEP-Moscow in Russia. It ruled out cross-sections for elastic scattering of WIMPs off nucleons above 3.9 × 10−8 pb from the two science runs conducted at Boulby.
X-ray detectors are devices used to measure the flux, spatial distribution, spectrum, and/or other properties of X-rays.
Micropattern gaseous detectors (MPGDs) are a group of gaseous ionization detectors consisting of microelectronic structures with sub-millimeter distances between anode and cathode electrodes. When interacting with the gaseous medium of the detector, particles of ionizing radiation create electrons and ions that are subsequently drifted apart by means of an electric field. The accelerated electrons create further electron-ion pairs in an avalanche process in regions with a strong electrostatic field. The various types of MPGDs differ in the way this strong field region is created. Examples of MPGDs include the microstrip gas chamber, the gas electron multiplier and the Micromegas detector.