Dynamic braking

Last updated
Norfolk Southern 5348 diesel-electric locomotive employs dynamic braking. The cooling grill for the brake grid resistors is at the top center of the locomotive. NSLocoNo.5348.jpg
Norfolk Southern 5348 diesel-electric locomotive employs dynamic braking. The cooling grill for the brake grid resistors is at the top center of the locomotive.

Dynamic braking is the use of an electric traction motor as a generator when slowing a vehicle such as an electric or diesel-electric locomotive. It is termed "rheostatic" if the generated electrical power is dissipated as heat in brake grid resistors, and "regenerative" if the power is returned to the supply line. Dynamic braking reduces wear on friction-based braking components, and regeneration lowers net energy consumption. Dynamic braking may also be used on railcars with multiple units, light rail vehicles, electric trams, trolleybuses, and electric and hybrid electric automobiles.

Contents

Principle of operation

Converting electrical energy to the mechanical energy of a rotating shaft (electric motor) is the inverse of converting the mechanical energy of a rotating shaft to electrical energy (electric generator). Both are accomplished through the interactions of armature windings with a (relatively) moving external magnetic field, with the armature connected to an electrical circuit with either a power supply (motor) or power receptor (generator). Since the role of the electrical/mechanical energy converting device is determined by which interface (mechanical or electrical) provides or receives energy, the same device can fulfill the role of either a motor or a generator. In dynamic braking, the traction motor is switched into the role of a generator by switching from a supply circuit to a receptor circuit while applying electric current to the field coils that generate the magnetic field (excitation).

The amount of resistance applied to the rotating shaft (braking power) equals the rate of electrical power generation plus some efficiency loss. That is in turn proportional to the strength of the magnetic field, controlled by the current in the field coils, and the rate at which the armature and magnetic field rotate against each other, determined by the rotation of the wheels and the ratio of power shaft to wheel rotation. The amount of braking power is controlled by varying the strength of the magnetic field through the amount of current in the field coils. As the rate of electrical power generation, and conversely braking power, are proportional to the rate at which the power shaft is spinning, a stronger magnetic field is required to maintain braking power as speed decreases and there is a lower limit at which dynamic braking can be effective depending on the current available for application to the field coils.

The two main methods of managing the electricity generated during dynamic braking are rheostatic braking and regenerative braking, as described below.

For permanent magnet motors, dynamic braking is easily achieved by shorting the motor terminals, thus bringing the motor to a fast abrupt stop. This method, however, dissipates all the energy as heat in the motor itself, and so cannot be used in anything other than low-power intermittent applications due to cooling limitations, such as in cordless power tools. It is not suitable for traction applications.

Rheostatic braking

The electrical energy produced by the motors is dissipated as heat by a bank of onboard resistors, referred to as the braking grid. Large cooling fans are necessary to protect the resistors from damage. Modern systems have thermal monitoring, so that if the temperature of the bank becomes excessive it will be switched off, and the braking will revert to being by friction only.

Regenerative braking

In electrified systems the process of regenerative braking is employed whereby the current produced during braking is fed back into the power supply system for use by other traction units, instead of being wasted as heat. It is normal practice to incorporate both regenerative and rheostatic braking in electrified systems. If the power supply system is not "receptive", i.e. incapable of absorbing the current, the system will default to rheostatic mode in order to provide the braking effect.

Yard locomotives with onboard energy storage systems which allow the recovery of some of the energy which would otherwise be wasted as heat are now available. The Green Goat model, for example, is being used by Canadian Pacific Railway, BNSF Railway, Kansas City Southern Railway and Union Pacific Railroad.

On modern passenger locomotives equipped with AC inverters pulling trains with sufficient head-end power (HEP) loads, braking energy can be used to power the train's on board systems via regenerative braking if the electrification system is not receptive or even if the track is not electrified to begin with. The HEP load on modern passenger trains is so great that some new electric locomotives such as the ALP-46 were designed without the traditional resistance grids.

Blended braking

A Connex South Eastern Class 466 EMU at London Blackfriars station in 2006, which has been fitted with dynamic blended braking New Connex EMU`.png
A Connex South Eastern Class 466 EMU at London Blackfriars station in 2006, which has been fitted with dynamic blended braking

Dynamic braking alone is not enough to stop a locomotive, because its braking effect rapidly diminishes below about 10 to 12 miles per hour (16 to 19 km/h). Therefore, it is always used in conjunction with the regular air brake. This combined system is called blended braking. Li-ion batteries have also been used to store energy for use in bringing trains to a complete halt. [1]

Although blended braking combines both dynamic and air braking, the resulting braking force is designed to be the same as the air brakes on their own provide. This is achieved by maximizing the dynamic brake portion, and automatically regulating the air brake portion, because the main purpose of dynamic braking is to reduce the amount of air braking required. That conserves air and minimizes the risks of over-heated wheels. One locomotive manufacturer, Electro-Motive Diesel (EMD), estimates that dynamic braking provides between 50% and 70% of the braking force during blended braking.

Self-load test

It is possible to use the brake grids as a form of dynamometer or load bank to perform a self-load test of the power output of a locomotive. With the locomotive stationary, the main generator (MG) output is connected to the grids instead of the traction motors. The grids are normally large enough to absorb the full engine power output, which is calculated from MG voltage and current output.

Hydrodynamic braking

Diesel locomotives with hydraulic transmission may be equipped for hydrodynamic braking. In this case, the torque converter or fluid coupling acts as a retarder in the same way as a water brake. Braking energy heats the hydraulic fluid, and the heat is dissipated (via a heat exchanger) by the engine cooling radiator. The engine will be idling (and producing little heat) during braking, so the radiator is not overloaded.

See also

Related Research Articles

<span class="mw-page-title-main">Electric motor</span> Machine that converts electrical energy into mechanical energy

An electric motor is an electrical machine that converts electrical energy into mechanical energy. Most electric motors operate through the interaction between the motor's magnetic field and electric current in a wire winding to generate force in the form of torque applied on the motor's shaft. An electric generator is mechanically identical to an electric motor, but operates in reverse, converting mechanical energy into electrical energy.

<span class="mw-page-title-main">Electric generator</span> Device that converts other energy to electrical energy

In electricity generation, a generator is a device that converts motion-based power or fuel-based power into electric power for use in an external circuit. Sources of mechanical energy include steam turbines, gas turbines, water turbines, internal combustion engines, wind turbines and even hand cranks. The first electromagnetic generator, the Faraday disk, was invented in 1831 by British scientist Michael Faraday. Generators provide nearly all the power for electrical grids.

<span class="mw-page-title-main">Alternator</span> Device converting mechanical into electrical energy

An alternator is an electrical generator that converts mechanical energy to electrical energy in the form of alternating current. For reasons of cost and simplicity, most alternators use a rotating magnetic field with a stationary armature. Occasionally, a linear alternator or a rotating armature with a stationary magnetic field is used. In principle, any AC electrical generator can be called an alternator, but usually the term refers to small rotating machines driven by automotive and other internal combustion engines.

<span class="mw-page-title-main">Regenerative braking</span> Energy recovery mechanism

Regenerative braking is an energy recovery mechanism that slows down a moving vehicle or object by converting its kinetic energy into a form that can be either used immediately or stored until needed. In this mechanism, the electric traction motor uses the vehicle's momentum to recover energy that would otherwise be lost to the brake discs as heat. This method contrasts with conventional braking systems. In those systems, the excess kinetic energy is converted to unwanted and wasted heat due to friction in the brakes, or with rheostatic brakes, where the energy is recovered by using electric motors as generators but is immediately dissipated as heat in resistors. In addition to improving the overall efficiency of the vehicle, regeneration can significantly extend the life of the braking system as the mechanical parts will not wear out quickly.

<span class="mw-page-title-main">DC motor</span> Motor which works on direct current

A DC motor is an electrical motor that uses direct current (DC) to produce mechanical force. The most common types rely on magnetic forces produced by currents in the coils. Nearly all types of DC motors have some internal mechanism, either electromechanical or electronic, to periodically change the direction of current in part of the motor.

<span class="mw-page-title-main">Traction motor</span> An electric motor for vehicle propulsion

A traction motor is an electric motor used for propulsion of a vehicle, such as locomotives, electric or hydrogen vehicles, or electric multiple unit trains.

<span class="mw-page-title-main">Motor–generator</span> Device for converting electrical power to another form

A motor–generator is a device for converting electrical power to another form. Motor–generator sets are used to convert frequency, voltage, or phase of power. They may also be used to isolate electrical loads from the electrical power supply line. Large motor–generators were widely used to convert industrial amounts of power while smaller motor–generators were used to convert battery power to higher DC voltages.

<span class="mw-page-title-main">Rotary converter</span> Electrical machine

A rotary converter is a type of electrical machine which acts as a mechanical rectifier, inverter or frequency converter.

This is an alphabetical list of articles pertaining specifically to electrical and electronics engineering. For a thematic list, please see List of electrical engineering topics. For a broad overview of engineering, see List of engineering topics. For biographies, see List of engineers.

<span class="mw-page-title-main">Motor drive</span>

Motor drive means a system that includes a motor. An adjustable speed motor drive means a system that includes a motor that has multiple operating speeds. A variable speed motor drive is a system that includes a motor and is continuously variable in speed. If the motor is generating electrical energy rather than using it – this could be called a generator drive but is often still referred to as a motor drive.

<span class="mw-page-title-main">Retarder (mechanical engineering)</span> Device for slowing down large vehicles

A retarder is a device used to augment or replace some of the functions of primary friction-based braking systems, usually on heavy vehicles. Retarders serve to slow vehicles, or maintain a steady speed while traveling down a hill, and help prevent the vehicle from "running away" by accelerating down the hill. They are not usually capable of bringing vehicles to a standstill, as their effectiveness diminishes as vehicle speed lowers. They are usually used as an additional "assistance" to slow vehicles, with the final braking done by a conventional friction braking system. As the friction brake will be used less, particularly at higher speeds, their service life is increased, and since in those vehicles the brakes are air-actuated helps to conserve air pressure too.

<span class="mw-page-title-main">AC motor</span> Electric motor driven by an AC electrical input

An AC motor is an electric motor driven by an alternating current (AC). The AC motor commonly consists of two basic parts, an outside stator having coils supplied with alternating current to produce a rotating magnetic field, and an inside rotor attached to the output shaft producing a second rotating magnetic field. The rotor magnetic field may be produced by permanent magnets, reluctance saliency, or DC or AC electrical windings.

<span class="mw-page-title-main">Load bank</span>

A load bank is a piece of electrical test equipment used to simulate an electrical load, to test an electric power source without connecting it to its normal operating load. During testing, adjustment, calibration, or verification procedures, a load bank is connected to the output of a power source, such as an electric generator, battery, servoamplifier or photovoltaic system, in place of its usual load. The load bank presents the source with electrical characteristics similar to its standard operating load, while dissipating the power output that would normally be consumed by it. The power is usually converted to heat by a heavy duty resistor or bank of resistive heating elements in the device, and the heat removed by a forced air or water cooling system. The device usually also includes instruments for metering, load control, and overload protection. Load banks can either be permanently installed at a facility to be connected to a power source when needed, or portable versions can be used for testing power sources such as standby generators and batteries. They are necessary adjuncts to replicate, prove, and verify the real-life demands on critical power systems. They are also used during operation of intermittent renewable power sources such as wind turbines to shed excess power that the electric power grid cannot absorb.

A brushed DC electric motor is an internally commutated electric motor designed to be run from a direct current power source and utilizing an electric brush for contact.

A metadyne is a direct current electrical machine with two pairs of brushes. It can be used as an amplifier or rotary transformer. It is similar to a third brush dynamo but has additional regulator or "variator" windings. It is also similar to an amplidyne except that the latter has a compensating winding which fully counteracts the effect of the flux produced by the load current. The technical description is "a cross-field direct current machine designed to utilize armature reaction". A metadyne can convert a constant-voltage input into a constant-current, variable-voltage output.

Electromagnetic brakes or EM brakes are used to slow or stop vehicles using electromagnetic force to apply mechanical resistance (friction). They were originally called electro-mechanical brakes but over the years the name changed to "electromagnetic brakes", referring to their actuation method which is generally unrelated to modern electro-mechanical brakes. Since becoming popular in the mid-20th century, especially in trains and trams, the variety of applications and brake designs has increased dramatically, but the basic operation remains the same.

In electrical engineering, electric machine is a general term for machines using electromagnetic forces, such as electric motors, electric generators, and others. They are electromechanical energy converters: an electric motor converts electricity to mechanical power while an electric generator converts mechanical power to electricity. The moving parts in a machine can be rotating or linear. Besides motors and generators, a third category often included is transformers, which although they do not have any moving parts are also energy converters, changing the voltage level of an alternating current.

<span class="mw-page-title-main">Magneto</span> Electricity-producing machine

A magneto is an electrical generator that uses permanent magnets to produce periodic pulses of alternating current. Unlike a dynamo, a magneto does not contain a commutator to produce direct current. It is categorized as a form of alternator, although it is usually considered distinct from most other alternators, which use field coils rather than permanent magnets.

This glossary of electrical and electronics engineering is a list of definitions of terms and concepts related specifically to electrical engineering and electronics engineering. For terms related to engineering in general, see Glossary of engineering.

References

  1. Professor Satoru Sone, Kogakuin University (2007-07-02). "Wayside and on-board storage can capture more regenerated energy". Railway Gazette International . Archived from the original on 10 July 2018. Retrieved 29 August 2021.