This article needs additional citations for verification .(February 2010) |
Hurricane coverings, commonly known as shutters, are used in hurricane mitigation to protect houses and other structures from damage caused by storms. Hurricane shutters are used to prevent windows from being broken by flying objects during a storm. Although the negative pressure caused by high-speed wind flowing over a building roof can cause the roof to fail with the building envelope intact, broken windows allow the air pressure to rise inside a building, creating an even greater pressure difference and increasing the likelihood of roof failure. [1] [2]
Shutters are frequently constructed from steel or aluminium, but homeowners sometimes use the low-cost alternative of plywood. The shutters are affixed to the outside of the building with screws, hurricane clips, or a track system. Advanced shutters may be motorized, and they may fold away when not in use.
Three major types of shutters are known alternatively as panel systems. They are usually made of plywood, metal (aluminium or steel), or polycarbonate plastic. Lexan panels are transparent, and may be flat or have been heat-formed into a corrugated shape to further increase impact resistance.[ citation needed ] Panels must be attached to the structure via screws in a direct mount or on tracks. When not in use, storm panels are stored in an easy to reach location. Newly constructed homes sometimes have an assigned area for storage of storm panels.
Another type of shutter is an accordion shutter which is made from interlocking vertical blades which slide into place horizontally.
Another type is the roll-up or rolling shutter, consisting of a series of slats that form a curtain with both sides of the curtain being inserted into guide rails. The curtain is then rolled onto an axle which is covered by a housing. Rolling shutters can be operated manually by gear, by pull strap or can be motorized independently or in conjunction with a manual override. Motorized shutters can be operated by either a switch or remote and can be controlled either individually or in groups.
On loss of power caused by hurricanes, motorized shutters must be operated manually, requiring either access to the motor (which can be difficult) or a pre-installed manual override. Most often, a manual override is operated using a gear. When deployed, all hurricane shutters require special techniques for firefighters to gain access to the interior of a structure.[ citation needed ]
Other types are the Bahamas, Colonials, and Tapco Hurricane Screens. Bahama shutters are mounted above the window creating shade when they are open, and when in use, they are brought down and secured over the window. Colonials are similar to the wooden shutters, but are made of aluminum. They hinge on the side of the windows and swing shut to protect the opening. Tapco Hurricane Screens are powder coated and made out of heavy-duty aluminum frames with stainless steel mesh used for the screening material.
Also used are awning shutters, with a horizontal hinge above the opening being protected.
Hurricane fabric coverings are a newer, relatively lower cost type of shutter. Tested and approved systems are made from polypropylene fibers, polyamide fibers or from laminated or cast PVC.
In 2011, a flat hurricane shutter system developed by UltraTek Worldwide was approved by Florida Building Code. [3] The unique system uses a synthetic rubber bracket to absorb hurricane forces, allowing a panel that is completely clear while weighing 11.3 oz/square foot, nearly half the weight of a traditional metal panel. [4]
Both the International Building Code (IBC) and the International Residential Code use the criteria set forth in ASTM E1886 & E1996 with regards to hurricane building material product approval. These test method norms describe the standardized tests to measure the impact resistance of a shutter and its resistance to cyclic wind pressure. The IBC's requirements are adaptable to all levels of required wind speed. [5]
The term impact resistant is defined as shutters, windows, and doors that have been proven to resist the impact from large windborne debris (defined by the test standards as a 9-pound 2x4 lumber missile striking end on at 34 mph). [2]
The Florida Building Code (FBC) is in most aspects similar to the IBC in regard to the testing and approval of hurricane shutters. According to the code, shutters are required for home built since 2001 unless the windows use impact-resistant glass. [6] The Miami-Dade County norms, often considered the most stringent requirements for hurricane shutters, rely on self-developed testing methods TAS201, 202 and 203. Passing the tests prescribed by the TAS norms is required only for shutters approved for use in the Florida HVHZ (High Velocity Hurricane Zone). The Florida Building Code will accept testing performed by TAS methods for inclusion in the FBC Database of approved building products.
Both Miami-Dade County and the State of Florida maintain web-searchable databases of products approved for use as hurricane protection. These typically include not only actual test results from certified independent testing laboratories, they also contain "Product Approval Drawings" or "Installation Instructions" which provide specifications for hurricane shutter assembly and installation. Both the product and installation method must be shown to be in compliance with these drawings in order for a shutter to be considered "code-rated". [7]
Besides the Florida Building Code and Miami-Dade County, there is also the Code from the Texas Department of Insurance commonly known as TDI. The Code from the Texas Department of Insurance is in many aspects similar to the International Building Code.
The Saffir–Simpson hurricane wind scale (SSHWS) classifies hurricanes—which in the Western Hemisphere are tropical cyclones that exceed the intensities of tropical depressions and tropical storms—into five categories distinguished by the intensities of their sustained winds. This measuring system was formerly known as the Saffir–Simpson hurricane scale, or SSHS.
A curtain wall is an exterior covering of a building in which the outer walls are non-structural, instead serving to protect the interior of the building from the elements. Because the curtain wall façade carries no structural load beyond its own dead load weight, it can be made of lightweight materials. The wall transfers lateral wind loads upon it to the main building structure through connections at floors or columns of the building.
The Great Miami Hurricane of 1926 was a large and intense tropical cyclone that devastated the Greater Miami area of Florida and caused catastrophic damage in the Bahamas and the U.S. Gulf Coast in September 1926, accruing a US$100 million damage toll. The devastation wrought by the hurricane resulted in the end of Florida's land boom, and represented an early start to the Great Depression in the state. It has been estimated that a similar hurricane would cause about $235 billion in damage if it were to hit Miami in 2018.
A window shutter is a solid and stable window covering usually consisting of a frame of vertical stiles and horizontal rails. Set within this frame can be louvers, solid panels, fabric, glass and almost any other item that can be mounted within a frame. Shutters may be employed for a variety of reasons, including controlling the amount of sunlight that enters a room, to provide privacy, security, to protect against weather or unwanted intrusion or damage and to enhance the aesthetics of a building.
A fire door is a door with a fire-resistance rating used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship. In North American building codes, it, along with fire dampers, is often referred to as a closure, which can be derated compared against the fire separation that contains it, provided that this barrier is not a firewall or an occupancy separation. In Europe national standards for fire doors have been harmonised with the introduction of the new standard EN 16034, which refers to fire doors as fire-resisting door sets. Starting September 2016, a common CE marking procedure was available abolishing trade barriers within the European Union for these types of products. In the UK, it is Part B of the Building Regulations that sets out the minimum requirements for the fire protection that must be implemented in all dwellings this includes the use of fire doors. All fire doors must be installed with the appropriate fire resistant fittings, such as the frame and door hardware, for it to fully comply with any fire regulations.
Cyclone mitigation encompasses the actions and planning taken before a tropical cyclone strikes to mitigate damage and injury from the storm. Knowledge of tropical cyclone impacts on an area help plan for future possibilities. Preparedness may involve preparations made by individuals as well as centralized efforts by governments or other organizations. Tracking storms during the tropical cyclone season helps individuals know current threats. Regional Specialized Meteorological Centers and Tropical Cyclone Warning Centers provide current information and forecasts to help individuals make the best decision possible.
Hurricane Wilma was the most intense tropical cyclone in the Atlantic basin and the second-most intense tropical cyclone in the Western Hemisphere, both based on barometric pressure, after Hurricane Patricia in 2015. Wilma's rapid intensification led to a 24-hour pressure drop of 97 mbar (2.9 inHg), setting a new basin record. At its peak, Hurricane Wilma's eye contracted to a record minimum diameter of 2.3 mi (3.7 km). In the record-breaking 2005 Atlantic hurricane season, Wilma was the twenty-second storm, thirteenth hurricane, sixth major hurricane, fourth Category 5 hurricane, and the second costliest.
Tropical Storm Leslie was a weak, short-lived tropical cyclone that was never well-organized; however, its precursor was costlier than any other tropical cyclone in the 2000 Atlantic hurricane season. The twelfth named storm of the season, Leslie formed on October 4 over eastern Florida as a subtropical cyclone, out of a trough of low pressure. Strengthening over open waters, it attained enough tropical characteristics to be reclassified as Tropical Storm Leslie on October 5. The storm reached peak winds of 45 mph (75 km/h) before wind shear weakened it, and on October 7 transitioned into an extratropical cyclone over the open Atlantic Ocean. Leslie lasted three more days before losing its identity.
A reduced pressure zone device is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices, reduced pressure zone assemblies (RPZA), or reduced pressure principle assembly (RPPA).
The Tampa Bay hurricane of 1921 was a destructive and deadly major hurricane which made landfall in the Tampa Bay area of Florida in late October 1921. The eleventh tropical cyclone, sixth tropical storm, and fifth hurricane of the season, the storm developed from a trough in the southwestern Caribbean Sea on October 20. Initially a tropical storm, the system moved northwestward and intensified into a hurricane on October 22 and a major hurricane by October 23. Later that day, the hurricane peaked as a Category 4 on the modern day Saffir–Simpson scale with maximum sustained winds of 140 mph (230 km/h). After entering the Gulf of Mexico, the hurricane gradually curved northeastward and weakened to a Category 3 before making landfall near Tarpon Springs, Florida, late on October 25. It was the first major hurricane to make landfall in the Tampa Bay area since the hurricane of 1848 and is the last to date. The storm weakened to a Category 1 hurricane while crossing the Florida peninsula, and it reached the Atlantic Ocean early the following day. Thereafter, the system moved east-southeastward and remained fairly steady in intensity before weakening to a tropical storm late on October 29. The storm was then absorbed by a larger extratropical cyclone early the next day, with the remnants of the hurricane soon becoming indistinguishable.
The Air Movement and Control Association International, Inc. (AMCA) is an American trade body that sets standards for Heating, Ventilation and Air Conditioning (HVAC) equipment. It rates fan balance and vibration, aerodynamic performance, air density, speed and efficiency.
The 1945 Homestead hurricane, known informally as Kappler's hurricane, was the most intense tropical cyclone to strike the U.S. state of Florida since 1935. The ninth tropical storm, third hurricane, and third major hurricane of the season, it developed east-northeast of the Leeward Islands on September 12. Moving briskly west-northwestward, the storm became a major hurricane on September 13. The system moved over the Turks and Caicos Islands the following day and then Andros on September 15. Later that day, the storm peaked as a Category 4 hurricane on the modern-day Saffir–Simpson scale with winds of 130 mph (215 km/h). Late on September 15, the hurricane made landfall on Key Largo and then in southern Dade County, Florida.
A roller shutter, security shutter, coiling door, roller door or sectional overhead door is a specialized type of door or window shutter consisting of multiple horizontal slats, bars, or web systems interconnected through hinges. The mechanism involves lifting the door to open it and lowering it to close. In the case of larger doors, an automated, motorized system may be employed.
Magnesium oxide, more commonly called magnesia, is a mineral that when used as part of a cement mixture and cast into thin cement panels under proper curing procedures and practices can be used in residential and commercial building construction. Some versions are suitable for general building uses and for applications that require fire resistance, mold and mildew control, as well as sound-control applications. Magnesia board has strength and resistance due to very strong bonds between magnesium and oxygen atoms that form magnesium oxide crystals.
Fire dampers are passive fire protection products used in heating, ventilation, and air conditioning (HVAC) ducts to prevent and isolate the spread of fire inside the ductwork through fire-resistance rated walls and floors. Fire/smoke dampers are similar to fire dampers in fire resistance rating, and also prevent the spread of smoke inside the ducts. When a rise in temperature occurs, the fire damper closes, usually activated by a thermal element which melts at temperatures higher than ambient but low enough to indicate the presence of a fire, allowing springs to close the damper blades. Fire dampers can also close following receipt of an electrical signal from a fire alarm system utilising detectors remote from the damper, indicating the sensing of heat or smoke in the building occupied spaces or in the HVAC duct system.
The David W. Dyer Federal Building and U.S. Courthouse, formerly known simply as the U.S. Post Office and Courthouse, is an historic United States Post Office and federal courthouse of the United States District Court for the Southern District of Florida located at 300 Northeast 1st Avenue in Miami, Florida. Built in 1931 of limestone, it is the largest such structure in South Florida.
Tornadoes, cyclones, and other storms with strong winds damage or destroy many buildings. However, with proper design and construction, the damage to buildings by these forces can be greatly reduced. A variety of methods can help a building survive strong winds and storm surge.
Hurricane Andrew at the time was the costliest disaster in Florida, as well as the then-costliest on record in the United States. Hurricane Andrew formed from a tropical wave on August 16, 1992, in the tropical Atlantic Ocean. It moved west-northwest and remained weak for several days due to strong wind shear. However, after curving westward on August 22, the storm rapidly intensified to reach peak winds of 175 mph (282 km/h). Following its passage through The Bahamas, Andrew made landfall near Homestead, Florida as a Category 5 hurricane on August 24. Eventually, Andrew struck southern Louisiana before it dissipated over the eastern United States on August 28.
Hurricane Andrew was a compact, but very powerful and devastating tropical cyclone that struck the Bahamas, Florida, and Louisiana in August 1992. It was the most destructive hurricane to ever hit Florida in terms of structures damaged or destroyed, and remained the costliest in financial terms until Hurricane Irma surpassed it 25 years later. Andrew was also the strongest landfalling hurricane in the United States in decades and the costliest hurricane to strike anywhere in the country, until it was surpassed by Katrina in 2005.
The Florida Building Code (FBC) is a set of standards designed by the Florida Building Commission for the construction of buildings in the US state of Florida. Many regulations and guidelines distributed are important benchmarks regarding hurricane protection. Miami-Dade County was the first in Florida to certify hurricane-resistant standards for structures which the Florida Building Code subsequently enacted across all requirements for hurricane-resistant buildings. Many other states reference the requirements set in the Florida Building codes, or have developed their own requirements for hurricanes.