In fluid thermodynamics, nucleate boiling is a type of boiling that takes place when the surface temperature is hotter than the saturated fluid temperature by a certain amount but where the heat flux is below the critical heat flux. For water, as shown in the graph below, nucleate boiling occurs when the surface temperature is higher than the saturation temperature (TS) by between 10 and 30 °C (18 and 54 °F). The critical heat flux is the peak on the curve between nucleate boiling and transition boiling. The heat transfer from surface to liquid is greater than that in film boiling.
Nucleate boiling is common in electric kettles and is responsible for the noise that occurs before boiling occurs. It also occurs in water boilers where water is rapidly heated.
Two different regimes may be distinguished in the nucleate boiling range. When the temperature difference is between approximately 4 to 10 °C (7.2 to 18.0 °F) above TS, isolated bubbles form at nucleation sites and separate from the surface. This separation induces considerable fluid mixing near the surface, substantially increasing the convective heat transfer coefficient and the heat flux. In this regime, most of the heat transfer is through direct transfer from the surface to the liquid in motion at the surface and not through the vapor bubbles rising from the surface.
Between 10 and 30 °C (18 and 54 °F) above TS, a second flow regime may be observed. As more nucleation sites become active, increased bubble formation causes bubble interference and coalescence. In this region the vapor escapes as jets or columns which subsequently merge into plugs of vapor.
Interference between the densely populated bubbles inhibits the motion of liquid near the surface. This is observed on the graph as a change in the direction of the gradient of the curve or an inflection in the boiling curve. After this point, the heat transfer coefficient starts to reduce as the surface temperature is further increased although the product of the heat transfer coefficient and the temperature difference (the heat flux) is still increasing.
When the relative increase in the temperature difference is balanced by the relative reduction in the heat transfer coefficient, a maximum heat flux is achieved as observed by the peak in the graph. This is the critical heat flux. At this point in the maximum, considerable vapor is being formed, making it difficult for the liquid to continuously wet the surface to receive heat from the surface. This causes the heat flux to reduce after this point. At extremes, film boiling commonly known as the Leidenfrost effect is observed.
The process of forming steam bubbles within liquid in micro cavities adjacent to the wall if the wall temperature at the heat transfer surface rises above the saturation temperature while the bulk of the liquid (heat exchanger) is subcooled. The bubbles grow until they reach some critical size, at which point they separate from the wall and are carried into the main fluid stream. There the bubbles collapse because the temperature of bulk fluid is not as high as at the heat transfer surface, where the bubbles were created. This collapsing is also responsible for the sound a water kettle produces during heat up but before the temperature at which bulk boiling is reached.
Heat transfer and mass transfer during nucleate boiling has a significant effect on the heat transfer rate. This heat transfer process helps quickly and efficiently to carry away the energy created at the heat transfer surface and is therefore sometimes desirable—for example in nuclear power plants, where liquid is used as a coolant.
The effects of nucleate boiling take place at two locations:
The nucleate boiling process has a complex nature. A limited number of experimental studies provided valuable insights into the boiling phenomena, however these studies provided often contradictory data due to internal recalculation (state of chaos in the fluid not applying to classical thermodynamic methods of calculation, therefore giving wrong return values) and have not provided conclusive findings yet to develop models and correlations. Nucleate boiling phenomenon still requires more understanding. [1]
The nucleate boiling regime is important to engineers because of the high heat fluxes possible with moderate temperature differences. The data can be correlated by an equation of the form [2]
Where Nu is the Nusselt number, defined as:
where:
Rohsenow has developed the first and most widely used correlation for nucleate boiling, [3]
where:
The variable n depends on the surface fluid combination and typically has a value of 1.0 or 1.7. For example, water and nickel have a Csf of 0.006 and n of 1.0.
Surface fluid combinations | |
---|---|
Water/copper | 0.013 |
Water/nickel | 0.006 |
Water/platinum | 0.013 |
Water/brass | 0.006 |
Water/stainless steel, mechanically polished | 0.0132 |
Water/stainless steel, chemically etched | 0.0133 |
Water/stainless steel, ground and polished | 0.0080 |
CCl4/copper | 0.013 |
Benzene/chromium | 0.0101 |
n-Pentane/chromium | 0.015 |
Ethyl alcohol/chromium | 0.0027 |
Isopropyl alcohol/copper | 0.0025 |
n-Butyl alcohol/copper | 0.003 |
If the heat flux of a boiling system is higher than the critical heat flux (CHF) of the system, the bulk fluid may boil, or in some cases, regions of the bulk fluid may boil where the fluid travels in small channels. Thus large bubbles form, sometimes blocking the passage of the fluid. This results in a departure from nucleate boiling (DNB) in which steam bubbles no longer break away from the solid surface of the channel, bubbles dominate the channel or surface, and the heat flux dramatically decreases. Vapor essentially insulates the bulk liquid from the hot surface.
During DNB, the surface temperature must therefore increase substantially above the bulk fluid temperature in order to maintain a high heat flux. Avoiding the CHF is an engineering problem in heat transfer applications, such as nuclear reactors, where fuel plates must not be allowed to overheat. DNB may be avoided in practice by increasing the pressure of the fluid, increasing its flow rate, or by utilizing a lower temperature bulk fluid which has a higher CHF. If the bulk fluid temperature is too low or the pressure of the fluid is too high, nucleate boiling is however not possible.
DNB is also known as transition boiling, unstable film boiling, and partial film boiling. For water boiling as shown on the graph, transition boiling occurs when the temperature difference between the surface and the boiling water is approximately 30 to 130 °C (54 to 234 °F) above the TS. This corresponds to the high peak and the low peak on the boiling curve. The low point between transition boiling and film boiling is the Leidenfrost point.
During transition boiling of water, the bubble formation is so rapid that a vapor film or blanket begins to form at the surface. However, at any point on the surface, the conditions may oscillate between film and nucleate boiling, but the fraction of the total surface covered by the film increases with increasing temperature difference. As the thermal conductivity of the vapor is much less than that of the liquid, the convective heat transfer coefficient and the heat flux reduces with increasing temperature difference.
Vapor pressure or equilibrium vapor pressure is the pressure exerted by a vapor in thermodynamic equilibrium with its condensed phases at a given temperature in a closed system. The equilibrium vapor pressure is an indication of a liquid's thermodynamic tendency to evaporate. It relates to the balance of particles escaping from the liquid in equilibrium with those in a coexisting vapor phase. A substance with a high vapor pressure at normal temperatures is often referred to as volatile. The pressure exhibited by vapor present above a liquid surface is known as vapor pressure. As the temperature of a liquid increases, the attractive interactions between liquid molecules become less significant in comparison to the entropy of those molecules in the gas phase, increasing the vapor pressure. Thus, liquids with strong intermolecular interactions are likely to have smaller vapor pressures, with the reverse true for weaker interactions.
Boiling or ebullition is the rapid phase transition from liquid to gas or vapor; the reverse of boiling is condensation. Boiling occurs when a liquid is heated to its boiling point, so that the vapour pressure of the liquid is equal to the pressure exerted on the liquid by the surrounding atmosphere. Boiling and evaporation are the two main forms of liquid vapourization.
In thermal fluid dynamics, the Nusselt number is the ratio of convective to conductive heat transfer at a boundary in a fluid. Convection includes both advection and diffusion (conduction). The conductive component is measured under the same conditions as the convective but for a hypothetically motionless fluid. It is a dimensionless number, closely related to the fluid's Rayleigh number.
In fluid mechanics, the Grashof number is a dimensionless number which approximates the ratio of the buoyancy to viscous forces acting on a fluid. It frequently arises in the study of situations involving natural convection and is analogous to the Reynolds number.
In fluid mechanics, the Rayleigh number (Ra, after Lord Rayleigh) for a fluid is a dimensionless number associated with buoyancy-driven flow, also known as free (or natural) convection. It characterises the fluid's flow regime: a value in a certain lower range denotes laminar flow; a value in a higher range, turbulent flow. Below a certain critical value, there is no fluid motion and heat transfer is by conduction rather than convection. For most engineering purposes, the Rayleigh number is large, somewhere around 106 to 108.
The Leidenfrost effect is a physical phenomenon in which a liquid, close to a surface that is significantly hotter than the liquid's boiling point, produces an insulating vapor layer that keeps the liquid from boiling rapidly. Because of this repulsive force, a droplet hovers over the surface, rather than making physical contact with it. The effect is named after the German doctor Johann Gottlob Leidenfrost, who described it in A Tract About Some Qualities of Common Water.
Surface tension is the tendency of liquid surfaces at rest to shrink into the minimum surface area possible. Surface tension is what allows objects with a higher density than water such as razor blades and insects to float on a water surface without becoming even partly submerged.
Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy (heat) between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes. Engineers also consider the transfer of mass of differing chemical species, either cold or hot, to achieve heat transfer. While these mechanisms have distinct characteristics, they often occur simultaneously in the same system.
A heat pipe is a heat-transfer device that employs phase transition to transfer heat between two solid interfaces.
In thermodynamics, the heat transfer coefficient or film coefficient, or film effectiveness, is the proportionality constant between the heat flux and the thermodynamic driving force for the flow of heat. It is used in calculating the heat transfer, typically by convection or phase transition between a fluid and a solid. The heat transfer coefficient has SI units in watts per square meter per kelvin (W/m²K).
Thermal hydraulics is the study of hydraulic flow in thermal fluids. The area can be mainly divided into three parts: thermodynamics, fluid mechanics, and heat transfer, but they are often closely linked to each other. A common example is steam generation in power plants and the associated energy transfer to mechanical motion and the change of states of the water while undergoing this process. Thermal-hydraulic analysis can determine important parameters for reactor design such as plant efficiency and coolability of the system.
The Marangoni effect is the mass transfer along an interface between two phases due to a gradient of the surface tension. In the case of temperature dependence, this phenomenon may be called thermo-capillary convection.
A zeotropicmixture, or non-azeotropic mixture, is a mixture with liquid components that have different boiling points. For example, nitrogen, methane, ethane, propane, and isobutane constitute a zeotropic mixture. Individual substances within the mixture do not evaporate or condense at the same temperature as one substance. In other words, the mixture has a temperature glide, as the phase change occurs in a temperature range of about four to seven degrees Celsius, rather than at a constant temperature. On temperature-composition graphs, this temperature glide can be seen as the temperature difference between the bubble point and dew point. For zeotropic mixtures, the temperatures on the bubble (boiling) curve are between the individual component's boiling temperatures. When a zeotropic mixture is boiled or condensed, the composition of the liquid and the vapor changes according to the mixtures's temperature-composition diagram.
In the study of heat transfer, critical heat flux (CHF) is the heat flux at which boiling ceases to be an effective form of transferring heat from a solid surface to a liquid.
In fluid mechanics, multiphase flow is the simultaneous flow of materials with two or more thermodynamic phases. Virtually all processing technologies from cavitating pumps and turbines to paper-making and the construction of plastics involve some form of multiphase flow. It is also prevalent in many natural phenomena.
In systems involving heat transfer, a condenser is a heat exchanger used to condense a gaseous substance into a liquid state through cooling. In so doing, the latent heat is released by the substance and transferred to the surrounding environment. Condensers are used for efficient heat rejection in many industrial systems. Condensers can be made according to numerous designs and come in many sizes ranging from rather small (hand-held) to very large. For example, a refrigerator uses a condenser to get rid of heat extracted from the interior of the unit to the outside air.
In engineering, physics, and chemistry, the study of transport phenomena concerns the exchange of mass, energy, charge, momentum and angular momentum between observed and studied systems. While it draws from fields as diverse as continuum mechanics and thermodynamics, it places a heavy emphasis on the commonalities between the topics covered. Mass, momentum, and heat transport all share a very similar mathematical framework, and the parallels between them are exploited in the study of transport phenomena to draw deep mathematical connections that often provide very useful tools in the analysis of one field that are directly derived from the others.
The vaporizing droplet problem is a challenging issue in fluid dynamics. It is part of many engineering situations involving the transport and computation of sprays: fuel injection, spray painting, aerosol spray, flashing releases… In most of these engineering situations there is a relative motion between the droplet and the surrounding gas. The gas flow over the droplet has many features of the gas flow over a rigid sphere: pressure gradient, viscous boundary layer, wake. In addition to these common flow features one can also mention the internal liquid circulation phenomenon driven by surface-shear forces and the boundary layer blowing effect.
A climbing/falling film plate evaporator is a specialized type of evaporator in which a thin film of liquid is passed over a rising and falling plate to allow the evaporation process to occur. It is an extension of the falling film evaporator, and has application in any field where the liquid to be evaporated cannot withstand extended exposure to high temperatures, such as the concentration of fruit juices.
The removal of heat from nuclear reactors is an essential step in the generation of energy from nuclear reactions. In nuclear engineering there are a number of empirical or semi-empirical relations used for quantifying the process of removing heat from a nuclear reactor core so that the reactor operates in the projected temperature interval that depends on the materials used in the construction of the reactor. The effectiveness of removal of heat from the reactor core depends on many factors, including the cooling agents used and the type of reactor. Common liquid coolants for nuclear reactors include: deionized water, heavy water, the lighter alkaline metals, lead or lead-based eutectic alloys like lead-bismuth, and NaK, a eutectic alloy of sodium and potassium. Gas cooled reactors operate with coolants like carbon dioxide, helium or nitrogen but some very low powered research reactors have even been air-cooled with Chicago Pile 1 relying on natural convection of the surrounding air to remove the negligible thermal power output. There is ongoing research into using supercritical fluids as reactor coolants but thus far neither the supercritical water reactor nor a reactor cooled with supercritical Carbon Dioxide nor any other kind of supercritical-fluid-cooled reactor has ever been built.
{{cite journal}}
: Cite journal requires |journal=
(help)