Registered jack

Last updated
Modular connectors, left to right:
Eight-position, eight-contact (8P8C) plug, as used for RJ45S, RJ49, RJ61, and others (though shown wired in a pattern incompatible with RJ61)
Six-position, six-contact (6P6C) plug, which can be used with RJ25, RJ14, and RJ11
Six-position, four-contact (6P4C) plug, which can be used with RJ14 and RJ11 (and will carry lines 1 and 2, but not line 3, of an RJ25)
Four-position, four-contact (4P4C) plug, used for connecting a telephone handset and base
Six-position, six-contact (6P6C) jack, which could be wired as RJ11, RJ14, or RJ25 Rjxx.jpg
Modular connectors, left to right:
  • Eight-position, eight-contact (8P8C) plug, as used for RJ45S, RJ49, RJ61, and others (though shown wired in a pattern incompatible with RJ61)
  • Six-position, six-contact (6P6C) plug, which can be used with RJ25, RJ14, and RJ11
  • Six-position, four-contact (6P4C) plug, which can be used with RJ14 and RJ11 (and will carry lines 1 and 2, but not line 3, of an RJ25)
  • Four-position, four-contact (4P4C) plug, used for connecting a telephone handset and base
  • Six-position, six-contact (6P6C) jack, which could be wired as RJ11, RJ14, or RJ25

A registered jack (RJ) is a standardized telecommunication network interface for connecting voice and data equipment to a computer service provided by a local exchange carrier or long distance carrier. Registered interfaces were first defined in the Universal Service Ordering Code (USOC) system of the Bell System in the United States for complying with the registration program for customer-supplied telephone equipment mandated by the Federal Communications Commission (FCC) in the 1970s. [1] They were subsequently codified in title 47 of the Code of Federal Regulations Part 68. [2] [3] [4] Registered jack connections began to see use after their invention in 1973 by Bell Labs. [5] The specification includes physical construction, wiring, and signal semantics. Accordingly, registered jacks are primarily named by the letters RJ, followed by two digits that express the type. Additional letter suffixes indicate minor variations. For example, RJ11, RJ14, and RJ25 are the most commonly used interfaces for telephone connections for one-, two-, and three-line service, respectively. Although these standards are legal definitions in the United States, some interfaces are used worldwide.

Contents

The connectors used for registered jack installations are primarily the modular connector and the 50-pin miniature ribbon connector. For example, RJ11 and RJ14 use female six-position modular connectors, and RJ21 uses a 25-pair (50-pin) miniature ribbon connector. RJ11 uses two conductors in a six-position female modular connector, so can be made with any female six-position modular connector, while RJ14 uses four, so can be made with either a 6P4C or a 6P6C connector.

Naming standard

The registered jack designations originated in the standardization process of telephone connections in the Bell System in the United States, and describe application circuits and not just the physical geometry of the connectors. The same modular connector type may be used for different registered jack applications. Modular connectors were developed to replace older telephone installation methods that used hardwired cords or bulkier varieties of telephone plugs.

Strictly, Registered Jack refers to both the female physical connector (modular connector) and specific wiring patterns, but the term is often used loosely to refer to modular connectors regardless of wiring, gender, or use, commonly for telephone line connections, but also for Ethernet over twisted pair, resulting in confusion over the various connection standards and applications. For example, the six-position physical connector, plug and jack, is identically dimensioned and inter-connectable, whether it is wired for one, two, or three lines. These are the RJ11, RJ14, and RJ25 interfaces. The RJ standards designations only pertain to the wiring of the (female) jacks, hence the name Registered Jack. It is commonplace, but not strictly correct, to refer to the unwired connectors or the (male) plugs by these names.

The nomenclature for modular connectors is based on the number of contact positions and the number of contacts present. 6P indicates a six-position modular plug or jack. A six-position modular plug with conductors in only the middle two positions is designated 6P2C; 6P4C has four conductors in the middle positions, and 6P6C has all six. An RJ11 without power, if made with a 6P6C connector, has four unused contacts.

History and authority

Registration interfaces were created by the Bell System under a Federal Communications Commission order for the standard interconnection between telephone company equipment and customer premises equipment.[ citation needed ] These interfaces used newly standardized jacks and plugs, primarily based on miniature modular connectors.

The wired communications provider (telephone company) is responsible for delivery of services to a minimum (or main) point of entry (MPOE). The MPOE is a utility box, usually containing surge protective circuitry, which connects the wiring on the customer's property to the communication provider's network. Customers are responsible for all jacks, wiring, and equipment on their side of the MPOE. The intent was to establish a universal standard for wiring and interfaces, and to separate ownership of in-home (or in-office) telephone wiring from the wiring owned by the service provider.

In the Bell System, following the Communications Act of 1934, the telephone companies owned all telecommunications equipment and they did not allow interconnection of third-party equipment. Telephones were generally hardwired, but may have been installed with Bell System connectors to permit portability. The legal case Hush-A-Phone v. United States (1956) and the Federal Communications Commission's (FCC) Carterfone (1968) decision brought changes to this policy, and required the Bell System to allow some interconnection, culminating in the development of registered interfaces using new types of miniature connectors.

Registered jacks replaced the use of protective couplers provided exclusively by the telephone company. The new modular connectors were much smaller and cheaper to produce than the earlier, bulkier connectors that were used in the Bell System since the 1930s. The Bell System issued specifications for the modular connectors and their wiring as Universal Service Order Codes (USOC), which were the only standards at the time. Large customers of telephone services commonly use the USOC to specify the interconnection type and, when necessary, pin assignments, when placing service orders with a network provider.

When the U.S. telephone industry was reformed to foster competition in the 1980s, the connection specifications became federal law, ordered by the FCC and codified in the Code of Federal Regulations (CFR), Title 47 CFR Part 68, Subpart F, [2] superseded by T1.TR5-1999. [3]

In January 2001, the FCC delegated responsibility for standardizing connections to the telephone network to a new private industry organization, the Administrative Council for Terminal Attachments (ACTA). [4] For this delegation, the FCC removed Subpart F from the CFR and added Subpart G. The ACTA derives its recommendations for terminal attachments from the standards published by the engineering committees of the Telecommunications Industry Association (TIA). ACTA and TIA jointly published the standard TIA/EIA-IS-968, [6] replacing the CFR information.

TIA-968-A, the current version of that standard, [6] details the physical aspects of modular connectors, but not the wiring. Instead, TIA-968-A incorporates the standard T1.TR5-1999, "Network and Customer Installation Interface Connector Wiring Configuration Catalog", [3] by reference. With the publication of TIA-968-B, the connector descriptions have been moved to TIA-1096-A. [4] A registered jack name, such as RJ11, still identifies both the physical connectors and the wiring (pinout) for each application.

Types

6P4C crimp-on style connector, commonly used for RJ11 and unpowered RJ14 Conector RJ11.jpg
6P4C crimp-on style connector, commonly used for RJ11 and unpowered RJ14

The most widely implemented registered jack in telecommunications is the RJ11. This is a modular connector wired for one telephone line, using the center two contacts of six available positions. This configuration is also used for single-line telephones in many countries other than the United States. It may also use a 6P4C connector, to use an additional wire pair for powering lamps on the telephone set. RJ14 is similar to RJ11, but is wired for two lines and RJ25 has three lines. RJ61 is a similar registered jack for four lines, but uses an 8P8C connector.

The RJ45S jack is rarely used in telephone applications, and the keyed 8P8C modular plug used for RJ45S mechanically cannot be inserted into an Ethernet port, but a similar plug, the non-keyed 8P8C modular plug never used for RJ45S is used in Ethernet networks, and the connector is often, however improperly, referred to as RJ45 in this context.

Officially recognized types of registered jacks
CodeConnectorUsage
RJA1X225A adapterConnector for a modular plug to a four-prong jack
RJA2X267A adapterConnector for splitting one modular jack to two modular jacks
RJA3X224A adapterConnector for adapting a modular plug to a 12-prong jack
RJ2MB50-pin2–12 telephone lines with make-busy arrangement
RJ11(C/W) 6P2C Establishes a bridged connection for one telephone line (6P4C if power on second pair)
RJ12(C/W) 6P6C Establishes a bridged connection for one telephone line with key telephone system control ahead of line circuit
RJ13(C/W) 6P4C Similar to RJ12, but behind the line circuit
RJ14(C/W) 6P4C For two telephone lines (6P6C if power on third pair)
RJ15C3-pin weatherproofFor one telephone line for boats in marinas
RJ18(C/W) 6P6C For one telephone line with make-busy arrangement
RJ21X50-pinMultiple (up to 25) line bridged T/R configuration
RJ25(C/W) 6P6C For three telephone lines
RJ26X50-pinFor multiple data lines, universal
RJ27X50-pinFor multiple data lines, programmed
RJ31X 8P8C Allows an alarm system to seize the telephone line to make an outgoing call during an alarm. The jack is placed closer to the network interface than all other equipment, and only 4 conductors are used.
RJ32X 8P8C Like RJ31X, this wiring provides a series tip and ring connection through the connecting block, but is used when the customer premises equipment is connected in series with a single station, such as an automatic dialer.
RJ33X 8P8C This wiring provides a series tip and ring connection of a KTS line ahead of the line circuit because the registered equipment requires CO/PBX ringing and a bridged connection of the A and A1 lead from behind the line circuit. The tip and ring are the only leads opened when the CPE plug is inserted. Typical usage is for customer-provided automatic dialers and call restrictors.
RJ34X 8P8C Similar to RJ33X, but all leads are connected behind the line circuit.
RJ35X 8P8C This arrangement provides a series tip and ring connection to whatever line has been selected in a key telephone set plus a bridged A and A1 lead.
RJ38X 8P4C Similar to RJ31X, with a continuity circuit. If the plug is disconnected from the jack, shorting bars allow the phone circuit to continue to the site phones. Only 4 conductors are used.
RJ41S 8P8C, keyedFor one data line, universal (fixed loop loss and programmed)
RJ45S 8P8C, keyedFor one data line, with programming resistor
RJ48C 8P4C For four-wire data line (DSX-1)
RJ48S 8P4C, keyedFor four-wire data line (DDS)
RJ48X 8P4C with shorting barFor four-wire data line (DS1)
RJ49C 8P8C For ISDN BRI via NT1
RJ61X 8P8C For four telephone lines
RJ71C50-pin12-line series connection using 50-pin connector (with bridging adapter) ahead of customer equipment. Mostly used for call sequencer equipment.

Many of the basic names have suffixes that indicate subtypes:

For example, RJ11 comes in two forms: RJ11W is a jack from which a wall telephone can be hung, while RJ11C is a jack designed to have a cord plugged into it. A cord can be plugged into an RJ11W as well.

RJ11, RJ14, RJ25 wiring

All of these registered jacks are described as containing a number of potential contact positions and the actual number of contacts installed within these positions. RJ11, RJ14, and RJ25 all use the same six-position modular connector, thus are physically identical except for the different number of contacts (two, four and six respectively) allowing connections for one, two, or three telephone lines respectively.

Cords connecting to an RJ11 interface require a 6P2C connector. Nevertheless, cords sold as RJ11 often use 6P4C connectors (six position, four conductor) with four wires. Two of the six possible contact positions connect tip and ring, and the other two conductors are unused.

The conductors other than the two central tip and ring conductors are in practice variously used for a second or third telephone line, a ground for selective ringers, low-voltage power for a dial light, or for anti-tinkle circuitry to prevent pulse dialing phones from sounding the bell on other extensions.

Pinout

Observing the male connector from the cable opening, with prong facing downward, the pins are numbered 1–6, left to right:

PositionPair T/R ±RJ11RJ14RJ25 Twisted pair colors 25-pair colors [upper-alpha 1] Old colors [upper-alpha 2] German colors [upper-alpha 3] Australian colorsDutch colors [upper-alpha 4] Diagram
13T+Does not appearDoes not appearT3 Wire white green stripe.svg
white/green
Wire white green stripe.svg
white/green
Wire white.svg
white
Wire violet.svg
pink
Wire orange.svg
orange
Does not appear Rj25 connector.jpg
6P6C connector showing the location of pin 1
22T+Does not appearT2T2 Wire white orange stripe.svg
white/orange
Wire white orange stripe.svg
white/orange
Wire black.svg
black
Wire green.svg
green
Wire red.svg
red
Wire orange.svg
orange
31RR1R1R1 Wire blue.svg
blue
Wire blue white stripe.svg
blue/white
Wire red.svg
red
Wire white.svg
white
Wire blue.svg
blue
Wire red.svg
red
41T+T1T1T1 Wire white blue stripe.svg
white/blue
Wire white blue stripe.svg
white/blue
Wire green.svg
green
Wire brown.svg
brown
Wire white.svg
white
Wire blue.svg
blue
52RDoes not appearR2R2 Wire orange.svg
orange
Wire orange white stripe.svg
orange/white
Wire yellow.svg
yellow
Wire yellow.svg
yellow
Wire black.svg
black
Wire white.svg
white
63RDoes not appearDoes not appearR3 Wire green.svg
green
Wire green white stripe.svg
green/white
Wire blue.svg
blue
Wire gray.svg
gray
Wire green.svg
green
Does not appear
  1. Established in the 1950s for polyethylene-insulated conductor (PIC) cable.Horn, F. W. (October 1958). "'Even-Count' Cable" (PDF). Bell Laboratories Record . 37 (5): 208–217. Retrieved October 13, 2022.
  2. While the old solid color code was well established for pair 1 and usually pair 2, there are several conflicting conventions for pair 3 (and sometimes even pair 2). The colors shown above were taken from a vendor of silver satin flat 8-conductor phone cable that claims to be standard. 6-pair solid (old) bellwire cables previously used by the Bell System use white for pair 3 tip but some vendors' cable may substitute orange for white. At least one other vendor of flat 8-conductor cable uses the sequence blue, orange, black, red, green, yellow, brown and white/slate.[ citation needed ]
  3. This color scheme originates in the (withdrawn) national standard DIN 47100. The scheme shown here is the correct color code for interfacing with the RJ connector standards.
  4. "(nl) Support document for the 'PTT norm 88'" (PDF). Watel (in Dutch). p. 8. Archived (PDF) from the original on 2016-10-08.

Provisioning of power

Some telephones such as the Western Electric Princess and Trimline telephone models require additional power (~6 V AC) for operation of the incandescent dial light. This power is delivered to the telephone set from a transformer by the second wire pair (pins 2 and 5) of the 6P4C connector.

RJ21

Female RJ21 connector. Pin assignment is coordinated with the table. RJ21-female-connector.jpg
Female RJ21 connector. Pin assignment is coordinated with the table.
Even-count color code
ColorPin
(tip)
Pin
(ring)
Color
Wire white blue stripe.svg White/blue261 Wire blue white stripe.svg Blue/white
Wire white orange stripe.svg White/orange272 Wire orange white stripe.svg Orange/white
Wire white green stripe.svg White/green283 Wire green white stripe.svg Green/white
Wire white brown stripe.svg White/brown294 Wire brown white stripe.svg Brown/white
Wire white gray stripe.svg White/slate305 Wire gray white stripe.svg Slate/white
Wire red blue stripe.svg Red/blue316 Wire blue red stripe.svg Blue/red
Wire red orange stripe.svg Red/orange327 Wire orange red stripe.svg Orange/red
Wire red green stripe.svg Red/green338 Wire green red stripe.svg Green/red
Wire red brown stripe.svg Red/brown349 Wire brown red stripe.svg Brown/red
Wire red gray stripe.svg Red/slate3510 Wire gray red stripe.svg Slate/red
Wire black blue stripe.svg Black/blue3611 Wire blue black stripe.svg Blue/black
Wire black orange stripe.svg Black/orange3712 Wire orange black stripe.svg Orange/black
Wire black green stripe.svg Black/green3813 Wire green black stripe.svg Green/black
Wire black brown stripe.svg Black/brown3914 Wire brown black stripe.svg Brown/black
Wire black gray stripe.svg Black/slate4015 Wire gray black stripe.svg Slate/black
Wire yellow blue stripe.svg Yellow/blue4116 Wire blue yellow stripe.svg Blue/yellow
Wire yellow orange stripe.svg Yellow/orange4217 Wire orange yellow stripe.svg Orange/yellow
Wire yellow green stripe.svg Yellow/green4318 Wire green yellow stripe.svg Green/yellow
Wire yellow brown stripe.svg Yellow/brown4419 Wire brown yellow stripe.svg Brown/yellow
Wire yellow gray stripe.svg Yellow/slate4520 Wire gray yellow stripe.svg Slate/yellow
Wire violet blue stripe.svg Violet/blue4621 Wire blue violet stripe.svg Blue/violet
Wire violet orange stripe.svg Violet/orange4722 Wire orange violet stripe.svg Orange/violet
Wire violet green stripe.svg Violet/green4823 Wire green violet stripe.svg Green/violet
Wire violet brown stripe.svg Violet/brown4924 Wire brown violet stripe.svg Brown/violet
Wire violet gray stripe.svg Violet/slate5025 Wire gray violet stripe.svg Slate/violet

RJ21 is a registered jack standard using a micro ribbon connector with contacts for up to fifty conductors. It is used to implement connections for up to 25 lines, or circuits that require many wire pairs, such as used in the 1A2 key telephone system. The miniature ribbon connector of this interface is also known as a 50-pin telco connector, CHAMP(AMP), or Amphenol connector, the last being a genericized trademark, as Amphenol was a prominent manufacturer of these at one time.

A cable color scheme, known as even-count color code, is determined for 25 pairs of conductors as follows: [7] For each ring, the primary, more prominent color is chosen from the set blue, orange, green, brown, and slate, in that order, and the secondary, thinner stripe color from the set of white, red, black, yellow, and violet colors, in that order. The tip conductor color scheme uses the same colors as the matching ring but switches the thickness of the primary and secondary colored stripes. Since the sets are ordered, an orange (color 2 in its set) with a yellow (color 4) is the color scheme for the 4·5 + 2 − 5 = 17th pair of wires. If the yellow is the more prominent, thicker stripe, then the wire is a tip conductor connecting to the pin numbered 25 + the pair #, which is pin 42 in this case. Ring conductors connect to the same pin number as the pair number.

A conventional enumeration of wire color pairs then begins blue (and white), orange (and white), green (and white) and brown (and white), which subsumes a color-coding convention used in cables of 4 or fewer pairs (8 wires or less) with 8P and 6P connectors.

Dual 50-pin ribbon connectors are often used on punch blocks to create a breakout box for private branch exchange (PBX) and other key telephone systems.

RJ45S

8P8C keyed female connector (jack), the same as that used in RJ45S RJ45 female connector.jpg
8P8C keyed female connector (jack), the same as that used in RJ45S

The RJ45S, an obsolete standard [8] jack once specified for modem or data interfaces, has a slot on one side to allow mating with a special variation of the 8P plug: a mechanically-keyed plug with an extra tab on one side that prevents it from mating with regular (non-keyed) 8P jacks. The visual difference from the more-common 8P female is subtle. The RJ45S keyed 8P modular connector has only pins 5 and 4 wired for tip and ring (respectively) of a single telephone line, and a "programming" resistor connected to pins 7 and 8. [9] [10] [11]

RJ48

RJ48C and RJ48X wiring
PinPairSignalColor
1RRX ring Wire orange white stripe.svg Orange/white
2TRX tip Wire white orange stripe.svg White/orange
3Reserved Wire white green stripe.svg White/green
4R1TX ring Wire blue white stripe.svg Blue/white
5T1TX tip Wire white blue stripe.svg White/blue
6Reserved Wire green white stripe.svg Green/white
7Shield Wire white brown stripe.svg White/brown
8Shield Wire brown white stripe.svg Brown/white

RJ48 is used for T1 and ISDN termination, local-area data channels, and subrate digital services. It uses the eight-position modular connector (8P8C).

RJ48C is commonly used for T1 circuits and uses pin numbers 1, 2, 4 and 5.

RJ48X is a variation that contains shorting blocks in the jack for troubleshooting: With no plug inserted, pins 2 and 5 (the two tip wires) are connected to each other, and likewise 1 and 4 (ring), creating a loopback so that a signal received on one pair is returned on the other. Sometimes this is referred to as a self-looping jack.

RJ48S is typically used for local-area data channels and subrate digital services and carries one line. It accepts a keyed variety of the 8P modular connector.

RJ48 connectors are fastened to shielded twisted pair (STP) cables, not the unshielded twisted-pair (UTP) commonly used in other installations.

RJ61

RJ61 wiring (USOC)
PinPairSignalColor
14Tip Wire white brown stripe.svg White/brown
23Tip Wire white green stripe.svg White/green
32Tip Wire white orange stripe.svg White/orange
41Ring Wire blue white stripe.svg Blue/white
51Tip Wire white blue stripe.svg White/blue
62Ring Wire orange white stripe.svg Orange/white
73Ring Wire green white stripe.svg Green/white
84Ring Wire brown white stripe.svg Brown/white

RJ61 is a physical interface that was often used for terminating twisted pair cables. It uses an eight-position, eight-conductor (8P8C) modular connector.

This wiring pattern is for multi-line analog telephone use only; RJ61 is unsuitable for use with high-speed data because the pins for pairs 3 and 4 are too widely spaced for high signaling frequencies. T1 lines use another wiring for the same connector, designated RJ48. Ethernet over twisted pair (10BASE-T, 100BASE-TX and 1000BASE-T) also uses different wiring for the same connector, either T568A or T568B. RJ48, T568A, and T568B are all designed to keep both wires of each pair close together.

The flat eight-conductor silver-satin cable conventionally used with four-line analog telephones and RJ61 jacks is also unsuitable for use with high-speed data. Twisted pair cabling is required for data applications. Twisted-pair patch cable typically used with common Ethernet and other data network standards is not compatible with RJ61, because RJ61 pairs 3 and 4 would each be split across two different twisted pairs in the patch cable, causing excessive cross-talk between voice lines 3 and 4, with conversations on each line literally being audible on the other.

With the advent of structured wiring systems and TIA/EIA-568 (now ANSI/TIA-568) conventions, the RJ61 wiring pattern is falling into disuse. The T568A and T568B standards are used in place of RJ61 so that a single wiring standard in a facility can be used for both voice and data.

Similar jacks and unofficial names

The following RJ-style names do not refer to official ACTA types.

The labels RJ9, RJ10, RJ22 are variously used for 4P4C and 4P2C modular connectors, most typically installed on telephone handsets and their cordage. Telephone handsets do not connect directly to the public network, and therefore have no registered jack designation.

RJ45 is often incorrectly used when referring to an 8P8C connector used for ANSI/TIA-568 T568A and T568B and Ethernet, however, the plug used for RJ45 is both mechanically and electrically incompatible with any Ethernet port: it cannot fit into an Ethernet port, and it is wired in a way that is incompatible with Ethernet. The connector commonly used for twisted-pair Ethernet is a non-keyed 8P8C connector, quite distinct from that used for RJ45S. The new ARJ45 interface, however, is a plug and jack allowing higher transmission rates, and the jack can, optionally, be backward-compatible with the common 8P8C plugs of Gigabit Ethernet and earlier standards.

RJ50 is often a 10P10C interface, often used for data applications.

The micro ribbon connector, first made by Amphenol, that is used in the RJ21 interface, has also been used to connect Ethernet ports in bulk from a switch with 50-pin ports to a Cat-5 rated patch panel, or between two patch panels. A cable with a 50-pin connector on one end can support six fully wired 8P8C connectors or Ethernet ports on a patch panel with one spare pair. Alternatively, only the necessary pairs for 10/100 Ethernet can be wired allowing twelve Ethernet ports with a single spare pair.

This connector is also used with spring bail locks for SCSI-1 connections. Some computer printers use a shorter 36-pin version known as a Centronics connector.

The 8P8C modular jack was chosen as a candidate for ISDN systems. In order to be considered, the connector system had to be defined by an international standard, leading to the creation of the ISO 8877 standard. Under the rules of the IEEE 802 standards project, international standards are to be preferred over national standards, so when the original 10BASE-T twisted-pair wiring version of Ethernet was developed, this modular connector was chosen as the basis for IEEE 802.3i-1990.

See also

Related Research Articles

<span class="mw-page-title-main">Ethernet over twisted pair</span> Ethernet physical layers using twisted-pair cables

Ethernet over twisted-pair technologies use twisted-pair cables for the physical layer of an Ethernet computer network. They are a subset of all Ethernet physical layers.

<span class="mw-page-title-main">Category 5 cable</span> Unshielded twisted pair communications cable

Category 5 cable (Cat 5) is a twisted pair cable for computer networks. Since 2001, the variant commonly in use is the Category 5e specification (Cat 5e). The cable standard provides performance of up to 100 MHz and is suitable for most varieties of Ethernet over twisted pair up to 2.5GBASE-T but more commonly runs at 1000BASE-T speeds. Cat 5 is also used to carry other signals such as telephone and video.

<span class="mw-page-title-main">LocalTalk</span>

LocalTalk is a particular implementation of the physical layer of the AppleTalk networking system from Apple Computer.

<span class="mw-page-title-main">600 series connector</span>

A 600 series connector is an obsolete three-pin connector with up to six conductors.

<span class="mw-page-title-main">Twisted pair</span> Type of wiring used for communications

Twisted pair cabling is a type of communications cable in which two conductors of a single circuit are twisted together for the purposes of improving electromagnetic compatibility. Compared to a single conductor or an untwisted balanced pair, a twisted pair reduces electromagnetic radiation from the pair and crosstalk between neighbouring pairs and improves rejection of external electromagnetic interference. It was invented by Alexander Graham Bell.

<span class="mw-page-title-main">Electrical connector</span> Device used to join electrical conductors

Components of an electrical circuit are electrically connected if an electric current can run between them through an electrical conductor. An electrical connector is an electromechanical device used to create an electrical connection between parts of an electrical circuit, or between different electrical circuits, thereby joining them into a larger circuit.

StarLAN was the first IEEE 802.3 standard for Ethernet over twisted pair wiring. It was standardized by the IEEE Standards Association as 802.3e in 1986, as the 1BASE5 version of Ethernet. The StarLAN Task Force was chaired by Bob Galin.

<span class="mw-page-title-main">25-pair color code</span> Form of color code used in wiring

The 25-pair color code, originally known as even-count color code, is a color code used to identify individual conductors in twisted-pair wiring for telecommunications.

<span class="mw-page-title-main">Telephone jack and plug</span> Connectors for wiring of telephone equipment

A telephone jack and a telephone plug are electrical connectors for connecting a telephone set or other telecommunications apparatus to the telephone wiring inside a building, establishing a connection to a telephone network. The plug is inserted into its counterpart, the jack, which is commonly affixed to a wall or baseboard. The standards for telephone jacks and plugs vary from country to country, though the 6P2C style modular plug has become by far the most common type.

<span class="mw-page-title-main">Telephone line</span> Single-user circuit on a telephone communication system

A telephone line or telephone circuit is a single-user circuit on a telephone communication system. It is designed to reproduce speech of a quality that is understandable. It is the physical wire or other signaling medium connecting the user's telephone apparatus to the telecommunications network, and usually also implies a single telephone number for billing purposes reserved for that user. Telephone lines are used to deliver landline telephone service and digital subscriber line (DSL) phone cable service to the premises. Telephone overhead lines are connected to the public switched telephone network. The voltage at a subscriber's network interface is typically 48 V between the ring and tip wires, with tip near ground and ring at –48 V.

<span class="mw-page-title-main">Crossover cable</span> Cable with intentionally crossed wiring

A crossover cable connects two devices of the same type, for example DTE-DTE or DCE-DCE, usually connected asymmetrically (DTE-DCE), by a modified cable called a crosslink. Such a distinction between devices was introduced by IBM.

<span class="mw-page-title-main">Swedish telephone plugs & sockets</span> Type of plug

A standard Swedish telephone plug carries one telephone line and has four flat metal pins and one plastic pin. The design is only used by Televerket in Sweden and older Póstur og Sími installations in Iceland. Neither plug nor socket is compatible with other plugs and sockets. It is defined in Swedish Standard SS 455 15 50.

<span class="mw-page-title-main">Structured cabling</span> Telecommunications cabling infrastructure

In telecommunications, structured cabling is building or campus cabling infrastructure that consists of a number of standardized smaller elements called subsystems. Structured cabling components include twisted pair and optical cabling, patch panels and patch cables.

<span class="mw-page-title-main">Category 6 cable</span> Standardized data communications cable

Category 6 cable (Cat 6) is a standardized twisted pair cable for Ethernet and other network physical layers that is backward compatible with the Category 5/5e and Category 3 cable standards.

<span class="mw-page-title-main">Medium-dependent interface</span> Interface between a network device and the data link it communicates over

A medium-dependent interface (MDI) describes the interface in a computer network from a physical-layer implementation to the physical medium used to carry the transmission. Ethernet over twisted pair also defines a medium-dependent interface – crossover (MDI-X) interface. Auto–MDI-X ports on newer network interfaces detect if the connection would require a crossover and automatically choose the MDI or MDI-X configuration to complement the other end of the link.

<span class="mw-page-title-main">Patch cable</span> Cable used to connect electronic or optical devices

A patch cable, patch cord or patch lead is an electrical or fiber-optic cable used to connect one electronic or optical device to another for signal routing. Devices of different types are connected with patch cords.

An Ethernet crossover cable is a crossover cable for Ethernet used to connect computing devices together directly. It is most often used to connect two devices of the same type, e.g. two computers or two switches to each other. By contrast, straight through patch cables are used to connect devices of different types, such as a computer to a network switch.

<span class="mw-page-title-main">Modular connector</span> Electrical connector commonly used in telephone and computer networks

A modular connector is a type of electrical connector for cords and cables of electronic devices and appliances, such as in computer networking, telecommunication equipment, and audio headsets.

<span class="mw-page-title-main">British telephone socket</span> Type of telephone socket design

British telephone sockets were introduced in their current plug and socket form on 19 November 1981 by British Telecom to allow subscribers to connect their own telephones. The connectors are specified in British Standard BS 6312. Electrical characteristics of the telephone interface are specified by individual network operators, e.g. in British Telecom's SIN 351. Electrical characteristics required of British telephones used to be specified in BS 6305.

ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).

References

  1. AT&T, Registration Interface—Selection and General Information, Bell System Practices, Section 463-400-100 Issue 1, May 1976
  2. 1 2 FCC 47 CFR Part 68 Connection of Terminal Equipment to the Telephone Network Archived 2017-07-05 at the Wayback Machine , Section 68.502 superseded by T1.TR5-1999
  3. 1 2 3 T1.TR5-1999 Archived 2012-03-01 at the Wayback Machine Network and Customer Installation Interface Connector Wiring Configuration Catalog
  4. 1 2 3 "ACTA Documents Main - Administrative Council for Terminal Attachments". www.part68.org. Archived from the original on 10 November 2010. Retrieved 9 May 2018.
  5. "RJ-11 Definition" . Retrieved 24 June 2020.
  6. 1 2 TIA-968-A Archived 2011-07-23 at the Wayback Machine or tia-eia-is-968 Archived 2011-07-23 at the Wayback Machine documents of FCC Archived 2010-11-21 at the Wayback Machine specifications from the Administrative Council for Terminal Attachments Archived 2016-04-22 at the Wayback Machine , section 6.2 in particular
  7. Ogletree, Terry William (2004). "Cables, Connectors, Concentrators, and Other Network Components". Upgrading and Repairing Networks (4 ed.). Que Publishing. p. 84. ISBN   0-7897-2817-6. Archived from the original on 2014-06-26.
  8. "The Basics of RJ45, RJ45s, and 8P8C Connectors and Cables". lifewire.com. Retrieved 22 November 2023.
  9. "RJ45S (Archived copy)". Archived from the original on 2018-05-09. Retrieved 2017-05-22.
  10. "Modular Jack Wiring". Hamilton Video & Sound Limited. Archived from the original on 2007-10-14. Retrieved 2017-05-21.
  11. "Modular Wiring Reference". Siemon. Archived from the original on 2010-10-08. Retrieved 2010-10-14.