Stokes Hill Power Station

Last updated

Stokes Hill Power Station
Stokes Hill Power Station
CountryAustralia
Location Darwin, Northern Territory
Coordinates 12°27′54″S130°50′59″E / 12.46500000°S 130.84972222°E / -12.46500000; 130.84972222
StatusDecommissioned
Commission date 1962
Decommission date1987
Owner(s)Northern Territory Electricity Commission (NTEC)
Operator(s)Northern Territory Electricity Commission (NTEC)
Thermal power station
Primary fuel Oil
Power generation
Nameplate capacity 141 MW
External links
Website territorygeneration.com.au/about-us/our-history/darwins-heritage-power-stations/

Stokes Hill Power Station was an oil-fired thermal power station in Darwin, Northern Territory, Australia. During its operating life, it was the largest power station in the Northern Territory, although it was considered unreliable and highly inefficient. Stokes Hill's high operating costs required government to heavily subsidise power bills for Darwin residents, [1] who frequently experienced supply disruptions.

The former Stokes Hill Power Station, date unknown Stokes Hill Power Station.jpg
The former Stokes Hill Power Station, date unknown

History

Design specifications in 1957 forecast that demand could initially be met by two turbo-alternator units of 74 MW each, with an additional smaller unit of 15 MW capacity expected to be required by 1971. [2] At its opening on 14 June 1962 however, the station was only capable of generating 15 MW [3] [4] Within months of opening, it was already apparent that even the originally specified capacity would be insufficient to meet the growing demand. [2] The Australian Bureau of Statistics indicate that by 1969, the power station was operating with four units, for a maximum installed capacity of 47 MW. [5] By 1977, further upgrades had brought the capacity up to its ultimate 141 MW. [3]

When Cyclone Tracy hit Darwin in 1974, the power station closed in the early hours of Christmas morning. Damage to the building by winds and storm surges resulted in flooding that damaged electrical equipment, while transmission lines and substations were completely destroyed. In the days immediately following the storm, small diesel generators were brought online at Stokes Hill in order to provide power to the old Darwin Hospital, located at Myilly Point in Larrakeyah. It was not until 25 January that power began to be restored to large parts of the city. [6]

Stokes Hill Power Station proved unreliable during its operational life, often unable to provide uninterrupted power supply for the city. A series of failures saw the power station supplemented with an additional 30 MW natural gas generator at Berrimah in 1979. [7]

Ownership of the power station was transferred from the Commonwealth to the Northern Territory Electricity Commission (NTEC) when the Northern Territory achieved self-government in 1978. In addition to reliability issues and the high cost of oil, by this time base-load demand for electricity in Darwin was growing at a rate of 3.5% per annum. These factors led to NTEC seeking a site for a new, modern power station. [1] The Channel Island site in Darwin Harbour's Middle Arm was selected in 1981.

Demolition of chimneys at the former Stokes Hill Power Station Demolition of Stokes Hill power station chimneys.jpg
Demolition of chimneys at the former Stokes Hill Power Station

The power station was decommissioned in 1987, following completion of the Channel Island Power Station. It sat dormant for nearly a decade until demolition was completed in 1997. Today, little trace of the power station is evident at the site, which is a short distance from the new Darwin Waterfront Precinct.

Related Research Articles

<span class="mw-page-title-main">Cyclone Tracy</span> Tropical cyclone in Australia in 1974

Severe Tropical Cyclone Tracy was a small tropical cyclone that devastated the city of Darwin, in the Northern Territory of Australia, in December 1974. The small, developing, easterly storm was originally expected to pass clear of the city, but it would turn towards it early on 24 December. After 10:00 p.m. ACST, damage became severe, with wind gusts reaching 217 km/h before instruments failed. The anemometer in Darwin Airport control tower had its needle bent in half by the strength of the gusts.

<span class="mw-page-title-main">National Grid (Great Britain)</span> High-voltage electric power transmission network in Great Britain

The National Grid is the high-voltage electric power transmission network serving Great Britain, connecting power stations and major substations, and ensuring that electricity generated anywhere on the grid can be used to satisfy demand elsewhere. The network serves the majority of Great Britain and some of the surrounding islands. It does not cover Northern Ireland, which is part of the Irish single electricity market.

<span class="mw-page-title-main">Liddell Power Station</span> Coal-fired power station in Australia

Liddell Power Station is a decommissioned coal-fired thermal power station that had four 500 megawatts (670,000 hp) EE steam-driven turbine alternators, providing a combined electrical capacity of 2,000 megawatts (2,700,000 hp).

<span class="mw-page-title-main">Tarong Power Station</span> Coal-fired power station in Australia

The Tarong Power Station is a coal fired power station located on a 1,500 hectares site in Tarong in the South Burnett Region near the town of Nanango, in Queensland, Australia. The station has a maximum generating capacity of 1,400 megawatts, generated from four turbines. Coal is supplied via a conveyor from Meandu Mine, which is 1.5 kilometres (0.93 mi) away and is also owned by Stanwell.

<span class="mw-page-title-main">Littlebrook Power Station</span> Series of four oil and coal-fired power stations in Dartford, Kent

The Littlebrook Power Station were a series of four oil and coal-fired power stations situated on the south bank of the River Thames, next to the Queen Elizabeth 2 Bridge and the Dartford Tunnel in Dartford, Kent. The final power station, Littlebrook D, ceased operating in March 2015, and has now been demolished.

<span class="mw-page-title-main">Barking Power Station</span>

Barking Power Station refers to a series of power stations at various sites within the London Borough of Barking and Dagenham in east London. The original power station site, of the coal-fired A, B and C stations, was at River Road, Creekmouth, on the north bank of the River Thames. These stations were decommissioned by 1981 and were subsequently demolished. The later gas-fired power station was built further down the Thames near Dagenham Dock in the early 1990s. The site of the former power stations is being redeveloped as Barking Riverside.

<span class="mw-page-title-main">Berrimah Power Station</span>

Berrimah Power Station is a kerosene-fuelled power station in Berrimah, an industrial suburb of Darwin, Northern Territory, Australia. It is owned by the government-owned Power and Water Corporation, and generates electricity only on an emergency and standby basis.

<span class="mw-page-title-main">Electricity sector in Iraq</span>

Iraq's electricity generation primarily depends on fossil fuels. In 2021, natural gas was the largest source at 57.3% of the total, followed by oil at 36.7%. Renewable energy, mainly from hydroelectric power, contributed 5.9%. As of 2023, the 30 gigawatts (GW) of installed capacity cannot meet summer peak demand.

Tamar Valley Power Station is a $230 million natural gas-fired power station located in Bell Bay in the Tamar Valley, Tasmania. It is owned by Hydro Tasmania, and is immediately adjacent to the decommissioned Bell Bay Power Station, which is also owned by Hydro Tasmania.

Operation Navy Help Darwin was a disaster relief operation initiated by the Royal Australian Navy (RAN) following the destruction of Darwin, Northern Territory by Cyclone Tracy during the night of 24–25 December 1974. 13 ships, 11 aircraft, and 3,000 personnel were sent to Darwin in the largest disaster relief operation undertaken by the RAN in its history. The RAN task force was present from 31 December 1974 to 31 January 1975.

<span class="mw-page-title-main">West Springfield Generating Station</span> Power plant in Massachusetts, U.S.

The West Springfield Generating Station, also known by its corporate name EP Energy Massachusetts, LLC, was a fossil-fuel-fired power plant located in West Springfield, Massachusetts. The station was a "peaking" facility, meaning that it primarily operates during peak electrical demand. The facility consisted of two 49-megawatt (MW) combustion turbine generators fueled by natural gas or ultra low-sulphur diesel fuel, one 18 MW jet turbine that was fueled by kerosene, and one 107 MW simple-cycle steam boiler unit burning no. 6 fuel oil, ULSD or natural gas. The station also had a small auxiliary boiler for process and building heat and an emergency back-up generator.

<span class="mw-page-title-main">History of electricity supply in Queensland</span>

The provision of electricity in Queensland required a considerable degree of pioneering, innovation, and commitment. Queensland proved to be a pioneer in the supply of electricity in Australia, with the first public demonstration in Australia, the first recorded use for public purposes in the country, the first Parliament House in Australia and the first commercial operations in Australia all occurring in Brisbane.

<span class="mw-page-title-main">Pelican Point Power Station</span> Engie power station near Adelaide, South Australia

The Pelican Point Power Station is located at Pelican Point, 20 km from the centre of Adelaide, South Australia on the Lefevre Peninsula. It is operated by Engie, which owns 72 per cent of the power station. Mitsui owns the remaining 28 per cent. It burns natural gas in a combined cycle power station, comprising two 160 MW gas turbines and one 165 MW steam turbine, to generate up to 485 MW of electricity.

<span class="mw-page-title-main">Electricity sector in Australia</span>

The electricity sector in Australia has been historically dominated by coal-fired power stations, but renewables are forming a rapidly growing fraction of supply. In 2021, Australia's electricity production reached 265 TWh, with coal accounting for 52.9% and natural gas for 18.8%. Renewable sources, comprising solar, wind, hydro, and bioenergy with waste, collectively made up 26.7% of the total electricity generation mix.

Channel Island Power Station is the largest power station in the Northern Territory of Australia. It is positioned on an island in the Middle Arm of Darwin Harbour, supplying electricity to the Darwin-Katherine Interconnected System. It is currently owned and operated by Territory Generation. Most of the island surrounding the facility is protected from development as the Channel Island Conservation Reserve.

The Lancaster power stations provided electricity to the Lancashire town and city of Lancaster and the surrounding area from 1894 to 1976. The first power station was built and operated by Lancaster Corporation and started generating electricity in April 1894. The second power station was built during the First World War near the Lune Aqueduct to provide electric power for a munitions factory. When the factory closed after the war the power station was purchased by the corporation to provide electric power throughout its supply area.

Sculcoates power station supplied electricity to Kingston upon Hull and the wider East Yorkshire area from 1898. An earlier 1893 station in Dagger Lane had operated public lighting in Hull Old Town. Sculcoates power station was built and operated by Kingston upon Hull Corporation on a site in Sculcoates Lane adjacent to the Beverley and Barmston Drain. The power station was increased in size as demand for electricity grew, it was redeveloped several times: including major rebuilds in 1927–29 and in 1938–1952. The power station was closed in 1976 and was subsequently demolished.

Weddell Power Station is a 129 MW natural gas-fired power station in the Northern Territory, located at Wickham, south-east of the Territory capital Darwin. Owned and operated by Territory Generation, it is the second largest power station in the Territory and supplies the Darwin-Katherine Interconnected System.

<span class="mw-page-title-main">Darwin Hospital</span> Hospital in Northern Territory, Australia

The Darwin Hospital was a former hospital that was located at Myilly Point in Larrakeyah, an inner suburb of Darwin, Northern Territory in Australia. It was the second public hospital to be built in the city, replacing a facility that had originally opened in 1874 nearby on Packard Street, Larrakeyah. The hospital had a short but eventful history, being extensively damaged by air-raids during World War II and by Cyclone Tracy in 1974. For most of its operating life, the hospital maintained segregated wards for Aboriginal patients, a policy that did not extend to those of mixed race or Asian descent. It was replaced by Royal Darwin Hospital in the early 1980s.

Katherine Power Station is a natural gas-fired power station in the Northern Territory of Australia located at Cossack near the town of Katherine. The power station is owned and operated by Territory Generation and supplies the Darwin-Katherine Interconnected System. The dual-fuel station can also independently provide power to Katherine in the event of disruptions across the regional grid, such as when gas supply was interrupted to Channel Island Power Station near Darwin during 2014. The generators in Katherine were able to use a back up supply of diesel fuel to minimise blackouts in the town.

References

  1. 1 2 "Northern Territory". Technology in Australia 1788-1988. Australian Academy of Technological Sciences and Engineering. Retrieved 13 January 2022.
  2. 1 2 Gordon Freeth, Minister for Works (29 October 1963). "Steam Power Station, Darwin". Parliamentary Debates (Hansard) . Commonwealth of Australia: House of Representatives. p. 2378.
  3. 1 2 "Darwin's Heritage Power Stations". Territory Generation . Retrieved 13 January 2022.
  4. Frank Brady, ed. (1996). "A Dictionary on Electricity" (PDF). International Council on Large Electric Systems . Retrieved 13 January 2022.
  5. J.P. O'Neill (November 1970). The Official Year Book of the Commonwealth of Australia, No. 56, 1970 (PDF). Australian Bureau of Statistics. p. 963.
  6. "Electricity Supply After Cyclone Tracy". Territory Generation. Retrieved 13 January 2022.
  7. "Power and Water Corporation - History". Archived from the original on 19 February 2008. Retrieved 13 January 2022.