TEA laser

Last updated

A TEA laser is a gas laser energized by a high-voltage electrical discharge in a gas mixture generally at or above atmospheric pressure. The most common types are carbon dioxide lasers and excimer lasers, both used extensively in industry and research; less common are nitrogen lasers. The acronym "TEA" stands for "transversely excited atmospheric".

Contents

History

Invention

The carbon dioxide (CO2) TEA laser was invented in the late 1960s by Jacques Beaulieu working at the Defence Research and Development Canada at Valcartier in Quebec, Canada. The development was kept secret until 1970, when brief details were published.

In 1963, C. Kumar N. Patel, working at Bell Telephone Laboratories, first demonstrated laser output at 10.6 μm from a low pressure RF-excited CO2 gas discharge. With the addition of nitrogen and helium and using a DC electrical discharge, CW powers of around 100 W were achieved. By pulsing the discharge using higher voltages, or Q-switching using a rotating mirror, pulse powers of a few kilowatts could be obtained as a practical limit.

Higher peak powers could only be achieved by increasing the density of excited CO2 molecules. The capacity for stored energy per unit volume of gas increases linearly with density and thus gas pressure, but the voltage needed to achieve gas breakdown and couple energy into the upper laser levels increases at the same rate. The practical solution avoiding very high voltages was to pulse the voltage transversely to the optical axis (rather than longitudinally as was the case for low pressure lasers), limiting the breakdown distance to a few centimetres. This allowed the use of manageable voltages of a few tens of kV. The problem was how to initiate and stabilize a glow discharge at these much higher gas pressures, without the discharge degenerating into a bright high-current arc, and how to achieve this over a useful volume of gas.

CO2 TEA laser

Beaulieu reported a transversely-excited atmospheric-pressure CO2 laser. His solution to the problem of arc formation was to have a conducting bar facing a linear array of pins with a separation of a few centimetres. The pins were individually loaded with resistors forcing the discharge from each pin into a low current brush or glow discharge which fanned out towards the bar. The laser cavity probed 100-200 of these discharges in series providing the laser gain. A fast discharge capacitor rapidly switched across the laser electrodes using a spark gap or thyratron provided the high voltage pulses.

These first "Pin-Bar" TEA lasers, operating at around one pulse per second, were easy and cheap to construct. By operating at atmospheric pressure, complex vacuum and gas-handling systems could be avoided. They could produce MW peak powers of a few 100 ns duration capable of breaking down air if brought to a focus with a short focal-length lens. Disadvantages were poor gain symmetry, dissipation in the resistors and size.

Pearson and Lamberton

TEA CO2 Laser Circuit TEA-Laser-Circuit.jpg
TEA CO2 Laser Circuit

The first true (non pin-bar) TEA laser was realized by Pearson and Lamberton working at the UK MOD Services Electronic Research Laboratory at Baldock. They used a pair of Rogowski-profiled electrodes separated by one or two centimetres. Their double-discharged[ clarification needed ] design coupled part of the discharge energy to a thin wire running parallel to, and offset from, one side of the electrodes. This served to pre-ionise the gas resulting in a uniform volumetric glow-discharge. Of equal importance to preionisation, was the need for the discharge to be very fast. By dumping energy into the gas rapidly, high-current arcs had no time to form.

Pearson and Lamberton used a streak camera to verify the sequence of events. As the voltage was erected across the electrodes, field emission from the thin wire resulted in a sheet discharge between itself and the anode. Since the subsequent main discharge started from the cathode, it was suggested that photoemission was the initiating mechanism. Subsequently, other workers had demonstrated alternative methods for achieving preionisation. These included dielectrically isolated wires and electrodes, sliding spark arrays, electron beams and pins impedance-loaded with capacitors.

The original Pearson-Lamberton TEA laser could be operated at around one pulse per second when switched with a spark gap discharging a capacitor resistively charged from a DC power supply. By circulating the gas between the electrodes, which was using lossless capacitor charging and replacing the spark-gap with a thyratron, repetition rates in excess of a thousand pulses per second were subsequently achieved with various designs of TEA laser.

Double-discharge method

The double-discharge method required to initiate stable high-pressure gas discharges can be used both below and above atmospheric pressure, and these devices too can be referred to as TEA lasers. Commercial excimer lasers operating in the ultraviolet use a double-discharge regime very similar to the CO2 TEA laser. Using krypton, argon or xenon chloride or fluoride gas buffered with helium to 23 atmospheres of pressure, excimer lasers can produce megawatt pulses of ultraviolet laser light.

Microscopic discharge description

In most over-voltage spark gaps avalanches of electrons move towards the anode. As the number of electrons increases Coulomb's law states that also the field strength increases. The strong field accelerates the avalanche. A slow rise time of the voltage lets the electrons drift towards the anode before they can generate an avalanche. Electrophilic molecules capture electrons before they can generate an avalanche. Thermal effects destabilize a homogeneous discharge electron and ion diffusion stabilizes it.

Applications

The Gaussian beam photographic paper burn
comparison of a carbon dioxide TEA laser, obtained during the optimization process by adjusting the alignment mirrors. Gaussian beam burn comparison.png
The Gaussian beam photographic paper burn comparison of a carbon dioxide TEA laser, obtained during the optimization process by adjusting the alignment mirrors.

TEA CO2 lasers are used extensively for product marking. A logo, serial number or best-before dated is marked on to a variety of packaging materials by passing the laser light through a mask containing the information, and focusing it down to an intensity which ablates the material to be marked. Beside this TEA CO2 lasers are used for surface preparation in industrial environments since the mid 1990s. Applications include:

The advantage of this specific laser is the combination of the CO2 specific wavelength, mainly 10.6 μm, with the high energy level of the short pulses (~2 μs).

In sociology of scientific knowledge

The development of the TEA Laser and the replication of building it at other research laboratories was researched by the sociologist Harry Collins. He analyzed how, rather than being able to build the laser from published sources alone, the researchers depended on phone calls and in-person laboratory visits to learn the skills needed to build a functioning TEA laser. Nevertheless, when sharing knowledge between each other, scientists also withheld information seen as relevant in the competition between laboratories (Collins 1974). This 1974 paper is considered seminal to introduce the revisited concept of tacit knowledge in sociology and history of science.

See also

Related Research Articles

<span class="mw-page-title-main">Geiger–Müller tube</span> Part of a Geiger counter

The Geiger–Müller tube or G–M tube is the sensing element of the Geiger counter instrument used for the detection of ionizing radiation. It is named after Hans Geiger, who invented the principle in 1908, and Walther Müller, who collaborated with Geiger in developing the technique further in 1928 to produce a practical tube that could detect a number of different radiation types.

<span class="mw-page-title-main">Spark gap</span> Two conducting electrodes separated in order to allow an electric spark to pass between

A spark gap consists of an arrangement of two conducting electrodes separated by a gap usually filled with a gas such as air, designed to allow an electric spark to pass between the conductors. When the potential difference between the conductors exceeds the breakdown voltage of the gas within the gap, a spark forms, ionizing the gas and drastically reducing its electrical resistance. An electric current then flows until the path of ionized gas is broken or the current reduces below a minimum value called the "holding current". This usually happens when the voltage drops, but in some cases occurs when the heated gas rises, stretching out and then breaking the filament of ionized gas. Usually, the action of ionizing the gas is violent and disruptive, often leading to sound, light, and heat.

<span class="mw-page-title-main">Corona discharge</span> Ionization of air around a high-voltage conductor

A corona discharge is an electrical discharge caused by the ionization of a fluid such as air surrounding a conductor carrying a high voltage. It represents a local region where the air has undergone electrical breakdown and become conductive, allowing charge to continuously leak off the conductor into the air. A corona discharge occurs at locations where the strength of the electric field around a conductor exceeds the dielectric strength of the air. It is often seen as a bluish glow in the air adjacent to pointed metal conductors carrying high voltages, and emits light by the same mechanism as a gas discharge lamp (Chemiluminescence). Corona discharges can also happen in weather, such as thunderstorms, where objects like ship masts or airplane wings have a charge significantly different from the air around them.

<span class="mw-page-title-main">Flashtube</span> Incoherent light source

A flashtube (flashlamp) produces an electrostatic discharge with an extremely intense, incoherent, full-spectrum white light for a very short time. A flashtube is a glass tube with an electrode at each end and is filled with a gas that, when triggered, ionizes and conducts a high-voltage pulse to make light. Flashtubes are used most in photography; they also are used in science, medicine, industry, and entertainment.

<span class="mw-page-title-main">Thyratron</span> Gas-filled tube, electrical switch, rectifier

A thyratron is a type of gas-filled tube used as a high-power electrical switch and controlled rectifier. Thyratrons can handle much greater currents than similar hard-vacuum tubes. Electron multiplication occurs when the gas becomes ionized, producing a phenomenon known as a Townsend discharge. Gases used include mercury vapor, xenon, neon, and hydrogen. Unlike a vacuum tube (valve), a thyratron cannot be used to amplify signals linearly.

<span class="mw-page-title-main">Gas-filled tube</span> Assembly of electrodes at either end of an insulated tube filled with gas

A gas-filled tube, also commonly known as a discharge tube or formerly as a Plücker tube, is an arrangement of electrodes in a gas within an insulating, temperature-resistant envelope. Gas-filled tubes exploit phenomena related to electric discharge in gases, and operate by ionizing the gas with an applied voltage sufficient to cause electrical conduction by the underlying phenomena of the Townsend discharge. A gas-discharge lamp is an electric light using a gas-filled tube; these include fluorescent lamps, metal-halide lamps, sodium-vapor lamps, and neon lights. Specialized gas-filled tubes such as krytrons, thyratrons, and ignitrons are used as switching devices in electric devices.

<span class="mw-page-title-main">Excimer laser</span> Type of ultraviolet laser important in chip manufacturing and eye surgery

An excimer laser, sometimes more correctly called an exciplex laser, is a form of ultraviolet laser which is commonly used in the production of microelectronic devices, semiconductor based integrated circuits or "chips", eye surgery, and micromachining.

<span class="mw-page-title-main">Paschen's law</span> Physical law about electrical discharge in gases

Paschen's law is an equation that gives the breakdown voltage, that is, the voltage necessary to start a discharge or electric arc, between two electrodes in a gas as a function of pressure and gap length. It is named after Friedrich Paschen who discovered it empirically in 1889.

<span class="mw-page-title-main">Glow discharge</span> Plasma formed by passage of current through gas

A glow discharge is a plasma formed by the passage of electric current through a gas. It is often created by applying a voltage between two electrodes in a glass tube containing a low-pressure gas. When the voltage exceeds a value called the striking voltage, the gas ionization becomes self-sustaining, and the tube glows with a colored light. The color depends on the gas used.

<span class="mw-page-title-main">Krytron</span> Gas-filled tube used as a high-speed switch

The krytron is a cold-cathode gas-filled tube intended for use as a very high-speed switch, somewhat similar to the thyratron. It consists of a sealed glass tube with four electrodes. A small triggering pulse on the grid electrode switches the tube on, allowing a large current to flow between the cathode and anode electrodes. The vacuum version is called a vacuum krytron, or sprytron. The krytron was one of the earliest developments of the EG&G Corporation.

<span class="mw-page-title-main">Proportional counter</span> Gaseous ionization detector

The proportional counter is a type of gaseous ionization detector device used to measure particles of ionizing radiation. The key feature is its ability to measure the energy of incident radiation, by producing a detector output pulse that is proportional to the radiation energy absorbed by the detector due to an ionizing event; hence the detector's name. It is widely used where energy levels of incident radiation must be known, such as in the discrimination between alpha and beta particles, or accurate measurement of X-ray radiation dose.

<span class="mw-page-title-main">Marx generator</span> High-voltage pulse generator

A Marx generator is an electrical circuit first described by Erwin Otto Marx in 1924. Its purpose is to generate a high-voltage pulse from a low-voltage DC supply. Marx generators are used in high-energy physics experiments, as well as to simulate the effects of lightning on power-line gear and aviation equipment. A bank of 36 Marx generators is used by Sandia National Laboratories to generate X-rays in their Z Machine.

<span class="mw-page-title-main">Gas laser</span> Laser in which electricity is discharged through gas

A gas laser is a laser in which an electric current is discharged through a gas to produce coherent light. The gas laser was the first continuous-light laser and the first laser to operate on the principle of converting electrical energy to a laser light output. The first gas laser, the Helium–neon laser (HeNe), was co-invented by Iranian engineer and scientist Ali Javan and American physicist William R. Bennett, Jr., in 1960. It produced a coherent light beam in the infrared region of the spectrum at 1.15 micrometres.

<span class="mw-page-title-main">Electric arc</span> Electrical breakdown of a gas that results in an ongoing electrical discharge

An electric arc is an electrical breakdown of a gas that produces a prolonged electrical discharge. The current through a normally nonconductive medium such as air produces a plasma, which may produce visible light. An arc discharge is initiated either by thermionic emission or by field emission. After initiation, the arc relies on thermionic emission of electrons from the electrodes supporting the arc. An arc discharge is characterized by a lower voltage than a glow discharge. An archaic term is voltaic arc, as used in the phrase "voltaic arc lamp".

<span class="mw-page-title-main">Nitrogen laser</span>

A nitrogen laser is a gas laser operating in the ultraviolet range using molecular nitrogen as its gain medium, pumped by an electrical discharge.

<span class="mw-page-title-main">Townsend discharge</span> Gas ionization process

In electromagnetism, the Townsend discharge or Townsend avalanche is an ionisation process for gases where free electrons are accelerated by an electric field, collide with gas molecules, and consequently free additional electrons. Those electrons are in turn accelerated and free additional electrons. The result is an avalanche multiplication that permits significantly increased electrical conduction through the gas. The discharge requires a source of free electrons and a significant electric field; without both, the phenomenon does not occur.

Plasma activation is a method of surface modification employing plasma processing, which improves surface adhesion properties of many materials including metals, glass, ceramics, a broad range of polymers and textiles and even natural materials such as wood and seeds. Plasma functionalization also refers to the introduction of functional groups on the surface of exposed materials. It is widely used in industrial processes to prepare surfaces for bonding, gluing, coating and painting. Plasma processing achieves this effect through a combination of reduction of metal oxides, ultra-fine surface cleaning from organic contaminants, modification of the surface topography and deposition of functional chemical groups. Importantly, the plasma activation can be performed at atmospheric pressure using air or typical industrial gases including hydrogen, nitrogen and oxygen. Thus, the surface functionalization is achieved without expensive vacuum equipment or wet chemistry, which positively affects its costs, safety and environmental impact. Fast processing speeds further facilitate numerous industrial applications.

<span class="mw-page-title-main">Dielectric barrier discharge</span> Electrical discharge between two electrodes separated by an insulating dielectric barrier

Dielectric-barrier discharge (DBD) is the electrical discharge between two electrodes separated by an insulating dielectric barrier. Originally called silent (inaudible) discharge and also known as ozone production discharge or partial discharge, it was first reported by Ernst Werner von Siemens in 1857.

A microplasma is a plasma of small dimensions, ranging from tens to thousands of micrometers. Microplasmas can be generated at a variety of temperatures and pressures, existing as either thermal or non-thermal plasmas. Non-thermal microplasmas that can maintain their state at standard temperatures and pressures are readily available and accessible to scientists as they can be easily sustained and manipulated under standard conditions. Therefore, they can be employed for commercial, industrial, and medical applications, giving rise to the evolving field of microplasmas.

An excimer lamp is a source of ultraviolet light based on spontaneous emission of excimer (exciplex) molecules.

References