Example of measurement of efficiency of the respirator (in the workplace). Description: (1) personal sampling pump, (2) the cassette and the filter for determining the concentration (in the breathing zone), (3) the sampling line (from the breathing zone), (4) the cassette and the filter to determine the concentration (under a mask), and (5) the sampling line (from the mask). Workplace Protection Factors Measurements.jpg
Example of measurement of efficiency of the respirator (in the workplace). Description: (1) personal sampling pump, (2) the cassette and the filter for determining the concentration (in the breathing zone), (3) the sampling line (from the breathing zone), (4) the cassette and the filter to determine the concentration (under a mask), and (5) the sampling line (from the mask).

Respirators, also known as respiratory protective equipment (RPE) or respiratory protective devices (RPD), are used in some workplaces to protect workers from air contaminants. Initially, respirator effectiveness was tested in laboratories, but in the late 1960s it was found that these tests gave misleading results regarding the level of protection provided. [1] In the 1970s, workplace-based respirator testing became routine in industrialized countries, leading to a dramatic reduction in the claimed efficacy of many respirator types and new guidelines on how to select the appropriate respirator for a given environment. [2] [3]

Contents

Background

A video describing respirator certification

The invention of the first personal sampling pump [4] [5] in 1958 made it possible to simultaneously measure the concentrations of air pollution outside and inside a respirator mask. This was the first attempt to measure the effectiveness of respiratory protective equipment. Until the 1970s experts mistakenly believed that the protective properties of a respirator in the laboratory were not significantly different from its properties in the workplace. There were therefore no measurements of the effectiveness of respirators under production conditions, and the regions where different types of respirators could be safely used were established on the basis of laboratory tests only.

This picture began to change when it was realized in the 1960s that workers using approved respirators were still being exposed to high levels of harmful contaminants. [1] Workplace studies have since shown that the effectiveness of respirators of all designs is much lower in real-world tests than in the laboratory. Under workplace conditions, employees must perform a variety of movements that testers in the lab do not. When the facepiece of the respirator is tightly fitted, these movements cause gaps to form between the mask and the face, decreasing the efficiency of the mask due to leakage of unfiltered air through the gaps. In addition, a small number of testers can not simulate all the variety of shapes and sizes of faces, and a 20-minute certification lab test [6] cannot simulate all the variety of movements performed in workplaces. Testers may also be more careful about putting on and using their masks than an ordinary worker.

Evolution of workplace-based testing standards

Initial workplace-based tests of effectiveness in the 1970s and 1980s

A groundbreaking study in 1974 on the effectiveness of respirators used by miners simultaneously measured dust concentrations with personal samplers worn by individual miners, and using two dust collectors, without the mask. [7] The researchers also measured the percentage of time that the miners used their respirators by attaching two thermistors to each miner (one in the facepiece, the other on the belt). Heat detection in the expired air was a sign of wearing a mask. The study defined a new measure, the "effective protection factor", that described the protection offered under real-world conditions, and reported the range of effective protection factors in four different mines.

In the steel fabrication industry, individuals performing sandblasting wore various types of hoods, usually supplied with air. Studies in 1975 found that the concentration of dust under these hoods exceeded the maximum permissible value, although air-supplied hoods offered better protection than non-air-supplied hoods. [8] Even when sandblasting was not occurring, the level of silica dust in the atmosphere far exceeded safe levels, meaning that time workers spent outside the hood on breaks led to exposure.

In copper smelters, three commonly used types of negative pressure filtering respirators with elastomeric half-masks were examined for their ability to protect workers against concentrations of sulfur dioxide in 1976. [9] The different respirator designs showed large variations in protectiveness, partially attributable to the comfort of the respirator design: the more comfortable masks were adjusted more tightly and were therefore more effective.

A 1979 study of the effectiveness of self-contained breathing apparatus (SCBA) in protecting firefighters against inhalation of carbon monoxide showed that intermittent usage of these respirators made them ineffective. [10] Even continuous usage of SCBAs did not provide complete protection. This SCBA design had an air supply into the mask that supplied air "on-demand" (i.e. allowing negative pressure under the mask during inhalation). US and EU legislation now requires the use of breathing apparatus with the "pressure-demand" mode of air supply (i.e. with positive pressure under the mask during inhalation) for firefighters.

Studies also found that worker-to-worker variation in the use of respirators can have very large effects on the protection achieved. A 1980 study on inhalation exposure of cadmium workers identified a single worker who always used his respirator correctly. The protection factor for this worker was found to be 26 times higher than that for the average worker. [11] In a study in coal mines, miners frequently removed their respirators in conditions where they perceived the dust level to be low, greatly reducing efficacy. [12] In another study, respirators with an expected protection factor of 1000 in fact had protection factors ranging from 15 to 216. [13] Factors affecting the level of protection achieved include the snugness of the fit of the respirator to the worker's face, [14] and air movement in the environment. [15]

New measures of efficacy

As researchers repeatedly found [16] [17] [18] that the level of protection actually experienced in the workplace was much lower than the protection factors assigned to the devices after laboratory testing, it was proposed that a new expected protection factor scale should be developed, such that the real effectiveness was higher than the "expected effectiveness" with a probability of at least 90%. [16]

Protection factors (PFs) of powered air-purifying respirators (PAPRs) with loose-fitting facepiece (hood or helmet). These data led to the assigned PF being lowered from 1000 to 25 PEL (USA), and from 1000 to 40 OEL (UK) Koeffitsienty zashchity PAPR en.jpg
Protection factors (PFs) of powered air-purifying respirators (PAPRs) with loose-fitting facepiece (hood or helmet). These data led to the assigned PF being lowered from 1000 to 25 PEL (USA), and from 1000 to 40 OEL (UK)

The significant differences between real and laboratory-measured effectiveness prompted the National Institute for Occupational Safety and Health (NIOSH) to release two informational messages on respirators in 1982, warning consumers about the unexpectedly low effectiveness of respirators. [19] After extensive discussion, six new definitions of respirator protection factors were agreed upon. [20] For example, the assigned protection factor (APF) of a respirator is the minimum protection factor the respirator must provide under the following circumstances: the respirator will be used by trained and taught workers, after individual selection of masks to fit the face of an employee, and will be used without interruption in the polluted atmosphere. [21] The actual protection experienced by a worker may be significantly lower than this and protection may vary from worker to worker. [22]

The Lepestok filtering half-mask, viewed from the inner side of the semi-finished product. The effectiveness of this filtering facepiece was overestimated by orders of magnitude. For the period 1956 to 2015, over 6 billion respirators were produced. Lepestok-200 staraia rasporka - 2.jpg
The Lepestok filtering half-mask, viewed from the inner side of the semi-finished product. The effectiveness of this filtering facepiece was overestimated by orders of magnitude. For the period 1956 to 2015, over 6 billion respirators were produced.

Respirator efficacy at Chernobyl

The central detail of the Liquidators' medal, with traces of alpha (a) and beta (b) particles and gamma (g) rays over a drop of blood. Medaille Tchernobyl goutte de sang.jpg
The central detail of the Liquidators' medal, with traces of alpha (α) and beta (β) particles and gamma (γ) rays over a drop of blood.

The Chernobyl nuclear accident in 1986 led to an urgent need for protection of workers from radioactive aerosols. Approximately 300,000 negative pressure filtering facepieces of the model "Lepestok" were sent to Chernobyl in June 1986. [23] These respirators were considered to be very effective (the declared protection factor for the most common model was 200). However, the individuals who used these respirators were exposed to excessive contamination. Just as in the case of the studies noted above, the declared protection factor was very different from the actual protection factor under real-world conditions. [24] As seen in other workplace tests, the passage of unfiltered air through the gap between the mask and face undermined the efficiency of the respirator. [25] [26] [27] However, these discoveries did not lead to a change in assessments of the effectiveness of respirators in the USSR.

Alternatives to respirator use

Workplace-based testing has led to extensively revised standards for the use of different designs of respirators, [28] [29] and has forced manufacturers to pay more attention to methods of hazard reduction such as sealing, ventilation, and automation, and to improvements in technology. For example, the National Institute for Occupational Safety and Health (USA) has provided recommendations for reducing dust concentrations in coal mines [30] and other mines. [31] Field measurements showed that respirators are the least reliable means of protection, with unstable and unpredictable efficacy.

Respirators are not convenient; they create discomfort and inhibit communication. [32] The reduction of the field of view due to respirator use leads to an increase in the risk of accidents.[ citation needed ] Respirators also reinforce overheating at high air temperature. [33] In real-world conditions, these deficiencies often lead to workers removing their respirators periodically, further reducing the efficacy of the respirator. In addition, respirators only protect workers against harmful substances entering the body through the respiratory system, whereas pollutants frequently also enter the body through the skin. [34] [35] Respirators thus cannot be used as substitutes for other measures that reduce the impact of air pollution on workers. However, if the respiratory system is the main way that harmful substances enter the body, and if other means of protection do not reduce the impact to an acceptable value, respirators may be a useful supplement. To maximize effectiveness, the type of respirator should be selected for the specific situation, masks should be chosen for employees personally, and workers should be trained to use the respirator effectively.[ citation needed ]

Reduction in permissible exposure limits

Legislation in industrialized countries establishes limitations on the use of all types of respirators, taking into account the results of field trials of efficacy. The permissible exposure limit [PEL] for several types of respirators was reduced. For example, for negative pressure air-purifying respirators with full face mask and high-efficiency filters, the limits were reduced from 500 PEL to 50 PEL (USA [16] ), and from 900 OEL to 40 OEL (UK [33] ); for powered air-purifying respirators with a loose-fitting facepiece (hood or helmet), limits were reduced from 1000 PEL to 25 PEL (USA [17] ); for powered air-purifying respirators with half mask, limits were reduced from 500 PEL to 50 PEL (USA [16] ); for supplied air respirators with full face mask and continuous air supply mode, limits were reduced from 100 OEL to 40 OEL (UK [36] ); for self-contained breathing apparatus respirators with air supply on demand, limits were reduced from 100 PEL to 50 PEL (USA). Filtering facepieces and negative pressure half-mask respirators were limited to 10 PEL in the USA. [37]

Table. Requirements for protection factors for different types of respirators before and after workplace testing
Respirator type, countryRequirements for protection factor for certification (2013)Permissible exposure limits prior to workplace testing (year)Permissible exposure limits after workplace testing (2013)Minimum values of measured workplace protection factors
PAPR with helmet, USA> 250 000 [6] up to 1000 PELup to 25 PEL [29] 28, 42 ...
Negative pressure air-purifying respirator with full face mask, USA> 250 000 [6] up to 100 PEL (1980)up to 50 PEL [29] 11, 16, 17 ...
Negative pressure air-purifying respirator with full face mask, UK> 2000 (for gases) or >1000 (for aerosols)up to 900 OEL (1980)up to 40 OEL
Negative pressure air-purifying respirator with half mask facepiece, USA> 25 000 [6] up to 10 PEL (since the 1960s [29] )2.2, 2.8, 4 ...
Self-contained breathing apparatus with air supply on demand, USA> 250 000 [6] up to 1000 PEL (1992)up to 50 PEL [29] Monitoring showed low efficiency for carbon monoxide exposure

The National Institute for Occupational Safety and Health of the USA now requires the manufacturers of high-performance RPE to perform testing at representative workplaces as a requirement for certification. [38]

See also

Related Research Articles

<span class="mw-page-title-main">Gas mask</span> Protection from inhaling airborne pollutants and toxic gases

A gas mask is an item of personal protective equipment used to protect the wearer from inhaling airborne pollutants and toxic gases. The mask forms a sealed cover over the nose and mouth, but may also cover the eyes and other vulnerable soft tissues of the face. Most gas masks are also respirators, though the word gas mask is often used to refer to military equipment, the scope used in this article. The gas mask only protects the user from digesting, inhaling, and contact through the eyes. Most combined gas mask filters will last around 8 hours in a biological or chemical situation. Filters against specific chemical agents can last up to 20 hours.

<span class="mw-page-title-main">Isocyanate</span> Chemical group (–N=C=O)

In organic chemistry, isocyanate is the functional group with the formula R−N=C=O. Organic compounds that contain an isocyanate group are referred to as isocyanates. An organic compound with two isocyanate groups is known as a diisocyanate. Diisocyanates are manufactured for the production of polyurethanes, a class of polymers.

<span class="mw-page-title-main">Personal protective equipment</span> Equipment designed to help protect an individual from hazards

Personal protective equipment (PPE) is protective clothing, helmets, goggles, or other garments or equipment designed to protect the wearer's body from injury or infection. The hazards addressed by protective equipment include physical, electrical, heat, chemicals, biohazards, and airborne particulate matter. Protective equipment may be worn for job-related occupational safety and health purposes, as well as for sports and other recreational activities. Protective clothing is applied to traditional categories of clothing, and protective gear applies to items such as pads, guards, shields, or masks, and others. PPE suits can be similar in appearance to a cleanroom suit.

<span class="mw-page-title-main">Occupational hygiene</span> Management of workplace health hazards

Occupational hygiene is the anticipation, recognition, evaluation, control, and confirmation (ARECC) of protection from risks associated with exposures to hazards in, or arising from, the workplace that may result in injury, illness, impairment, or affect the well-being of workers and members of the community. These hazards or stressors are typically divided into the categories biological, chemical, physical, ergonomic and psychosocial. The risk of a health effect from a given stressor is a function of the hazard multiplied by the exposure to the individual or group. For chemicals, the hazard can be understood by the dose response profile most often based on toxicological studies or models. Occupational hygienists work closely with toxicologists for understanding chemical hazards, physicists for physical hazards, and physicians and microbiologists for biological hazards. Environmental and occupational hygienists are considered experts in exposure science and exposure risk management. Depending on an individual's type of job, a hygienist will apply their exposure science expertise for the protection of workers, consumers and/or communities.

<span class="mw-page-title-main">Respirator</span> Device worn to protect the user from inhaling contaminants

A respirator is a device designed to protect the wearer from inhaling hazardous atmospheres including fumes, vapours, gases and particulate matter such as dusts and airborne pathogens such as viruses. There are two main categories of respirators: the air-purifying respirator, in which respirable air is obtained by filtering a contaminated atmosphere, and the air-supplied respirator, in which an alternate supply of breathable air is delivered. Within each category, different techniques are employed to reduce or eliminate noxious airborne contaminants.

<span class="mw-page-title-main">Dust mask</span> Pad held over the nose and mouth to protect against dust

A dust mask is a flexible paper pad held over the nose and mouth by elastic or rubber straps for personal comfort against non-toxic nuisance dusts. They are not intended to provide protection from toxic airborne hazards. The European FFP1 mask, the lowest-grade mechanical filter respirator available in the jurisdiction, is also used as a dust mask.

<span class="mw-page-title-main">Respirator fit test</span> Safety procedure for testing PPE air-tightness

A respirator fit test checks whether a respirator properly fits the face of someone who wears it. The fitting characteristic of a respirator is the ability of the mask to separate a worker's respiratory system from ambient air.

<span class="mw-page-title-main">Chemical cartridge</span> Container that cleans pollution from air inhaled through it

A respirator cartridge or canister is a type of filter that removes gases, volatile organic compounds (VOCs), and other vapors from air through adsorption, absorption, or chemisorption. It is one of two basic types of filters used by air-purifying respirators. The other is a mechanical filter, which removes only particulates. Hybrid filters combine the two.

<span class="mw-page-title-main">NIOSH air filtration rating</span> U.S. rating of respirators such as face masks

The NIOSH air filtration rating is the U.S. National Institute for Occupational Safety and Health (NIOSH)'s classification of filtering respirators. The ratings describe the ability of the device to protect the wearer from solid and liquid particulates in the air. The certification and approval process for respiratory protective devices is governed by Part 84 of Title 42 of the Code of Federal Regulations. Respiratory protective devices so classified include air-purifying respirators (APR) such as filtering facepiece respirators and chemical protective cartridges that have incorporated particulate filter elements.

<span class="mw-page-title-main">Powered air-purifying respirator</span>

A powered air-purifying respirator (PAPR) is a type of respirator used to safeguard workers against contaminated air. PAPRs consist of a headgear-and-fan assembly that takes ambient air contaminated with one or more type of pollutant or pathogen, actively removes (filters) a sufficient proportion of these hazards, and then delivers the clean air to the user's face or mouth and nose. They have a higher assigned protection factor than filtering facepiece respirators such as N95 masks. PAPRs are sometimes called positive-pressure masks, blower units, or just blowers.

<span class="mw-page-title-main">Respirator assigned protection factors</span>

The respiratory protective devices (RPD) can protect workers only if their protective properties are adequate to the conditions in the workplace. Therefore, specialists have developed criteria for the selection of proper, adequate respirators, including the Assigned Protection Factors (APF) - the decrease of the concentration of harmful substances in the inhaled air, which to be provided with timely and proper use of a certified respirator of certain types (design) by taught and trained workers, when the employer performs an effective respiratory protective device programme.

<span class="mw-page-title-main">Chemical protective clothing</span>

Chemical protective clothing (CPC) is clothing worn to shield those who work with chemicals from the effects of chemical hazards that can cause injuries on the job. It provides a last line of defense for chemical safety; it does not replace more proactive measures like engineering controls.

The health and safety hazards of nanomaterials include the potential toxicity of various types of nanomaterials, as well as fire and dust explosion hazards. Because nanotechnology is a recent development, the health and safety effects of exposures to nanomaterials, and what levels of exposure may be acceptable, are subjects of ongoing research. Of the possible hazards, inhalation exposure appears to present the most concern, with animal studies showing pulmonary effects such as inflammation, fibrosis, and carcinogenicity for some nanomaterials. Skin contact and ingestion exposure, and dust explosion hazards, are also a concern.

<span class="mw-page-title-main">Hearing protection device</span> Protection device for auditory organs

A hearing protection device, also known as a HPD, is an ear protection device worn in or over the ears while exposed to hazardous noise and provide hearing protection to help prevent noise-induced hearing loss. HPDs reduce the level of the noise entering the ear. HPDs can also protect against other effects of noise exposure such as tinnitus and hyperacusis. There are many different types of HPDs available for use, including earmuffs, earplugs, electronic hearing protection devices, and semi-insert devices.

<span class="mw-page-title-main">N95 respirator</span> Particulate respirator meeting the N95 standard

An N95 filtering facepiece respirator, commonly abbreviated N95 respirator, is a particulate-filtering facepiece respirator that meets the U.S. National Institute for Occupational Safety and Health (NIOSH) N95 classification of air filtration, meaning that it filters at least 95% of airborne particles that have a mass median aerodynamic diameter of 0.3 micrometers. This standard does not require that the respirator be resistant to oil; another standard, P95, adds that requirement. The N95 type is the most common particulate-filtering facepiece respirator. It is an example of a mechanical filter respirator, which provides protection against particulates but not against gases or vapors. An authentic N95 respirator is marked with the text "NIOSH" or the NIOSH logo, the filter class ("N95"), a "TC" approval number of the form XXX-XXXX, the approval number must be listed on the NIOSH Certified Equipment List (CEL) or the NIOSH Trusted-Source page, and it must have headbands instead of ear loops.

<span class="mw-page-title-main">Workplace hazard controls for COVID-19</span> Prevention measures for COVID-19

Hazard controls for COVID-19 in workplaces are the application of occupational safety and health methodologies for hazard controls to the prevention of COVID-19. Vaccination is the most effective way to protect against severe illness or death from COVID-19. Multiple layers of controls are recommended, including measures such as remote work and flextime, increased ventilation, personal protective equipment (PPE) and face coverings, social distancing, and enhanced cleaning programs.

<span class="mw-page-title-main">Mechanical filter (respirator)</span> Air-filtering face masks or mask attachments

Mechanical filters are a class of filter for air-purifying respirators that mechanically stops particulates from reaching the wearer's nose and mouth. They come in multiple physical forms.

<span class="mw-page-title-main">Source control (respiratory disease)</span> Strategy for reducing disease transmission

Source control is a strategy for reducing disease transmission by blocking respiratory secretions produced through speaking, coughing, sneezing or singing. Surgical masks are commonly used for this purpose, with cloth face masks recommended for use by the public only in epidemic situations when there are shortages of surgical masks. In addition, respiratory etiquette such as covering the mouth and nose with a tissue when coughing can be considered source control. In diseases transmitted by droplets or aerosols, understanding air flow, particle and aerosol transport may lead to rational infrastructural source control measures that minimize exposure of susceptible persons.

<span class="mw-page-title-main">Elastomeric respirator</span> Respirator with a rubber face seal

Elastomeric respirators, also called reusable air-purifying respirators, seal to the face with elastomeric material, which may be a natural or synthetic rubber. They are generally reusable. Full-face versions of elastomeric respirators seal better and protect the eyes.

<span class="mw-page-title-main">Supplied-air respirator</span> Breathing apparatuus remotely supplied by an air hose

A supplied-air respirator (SAR) or air-line respirator is a breathing apparatus used in places where the ambient air may not be safe to breathe. It uses an air hose to supply air from outside the danger zone. It is similar to a self-contained breathing apparatus (SCBA), except that SCBA users carry their air with them in high pressure cylinders, while SAR users get it from a remote stationary air supply connected to them by a hose.

References

  1. 1 2 Cralley, Lesly; Cralley, Lester (1985). Patty's Industrial Hygiene and Toxicology. Vol. 3A (2 ed.). New York: Willey-Interscience. pp. 677–678. ISBN   0-471-86137-5.
  2. Miller, Donald; et al. (1987). NIOSH Respirator Decision Logic. National Institute for Occupational Safety and Health. p. 61. doi:10.26616/NIOSHPUB87108 . Retrieved 16 July 2016.
  3. Kirillov, Vladimir; et al. (2014). "Overview of Industrial Testing Outcome of Respiratory Organs Personal Protection Equipment". Toksikologicheskiy Vestnik (in English and Russian). 6 (129): 44–49. doi:10.17686/sced_rusnauka_2014-1034. ISSN   0869-7922.
  4. Sherwood, Robert (1966). "On the Interpretation of Air Sampling for Radioactive Particles". American Industrial Hygiene Association Journal. 27 (2): 98–109. doi:10.1080/00028896609342800. ISSN   1542-8117. PMID   5954012 . Retrieved 10 July 2016.
  5. Sherwood, Robert; Greenhalgh, D.M.S. (1960). "A Personal Air Sampler". The Annals of Occupational Hygiene. 2 (2): 127–132. doi:10.1093/annhyg/2.2.127. ISSN   0003-4878. PMID   14445915 . Retrieved 10 July 2016.
  6. 1 2 3 4 5 NIOSH standard 42 Code of Federal Register Part 84 "Respiratory Protective Devices"
  7. Harris, H.E.; DeSieghardt, W.C.; Burgess, W. A.; Reist, Parker (1974). "Respirator Usage and Effectiveness in Bituminous Coal Mining Operations". American Industrial Hygiene Association Journal. 35 (3): 159–164. doi:10.1080/0002889748507018. ISSN   1542-8117. PMID   4522752.
  8. Behzad, Samimi; Neilson, Arthur; Weill, Hans; Ziskind, Morton (1975). "The Efficiency of Protective Hoods Used by Sandblasters to Reduce Silica Dust Exposure". American Industrial Hygiene Association Journal. 36 (2): 140–148. doi:10.1080/0002889758507222. ISSN   1542-8117. PMID   167570.
  9. Moore, David; Smith, Thomas (1976). "Measurement of protection factors of chemical cartridge, half-mask respirators under working conditions in a copper smelter". American Industrial Hygiene Association Journal. 37 (8): 453–458. doi:10.1080/0002889768507495. ISSN   1542-8117. PMID   970320.
  10. Levin, Marshal (1979). "Respirator use and protection from exposure to carbon monoxide". American Industrial Hygiene Association Journal. 40 (9): 832–834. doi:10.1080/15298667991430361. ISSN   1542-8117. PMID   517443.
  11. Smith, Thomas; Ferrel, Willard; Varner, Michael; Putnam, Robert (1980). "Inhalation exposure of cadmium workers: effects of respirator usage". American Industrial Hygiene Association Journal. 41 (9): 624–629. doi:10.1080/15298668091425400. ISSN   1542-8117. PMID   7457382 . Retrieved 10 July 2016.
  12. Howie, Robin M.; Walton, W.H. (1981). "Practical Aspects of the Use of Respirators in the British Coal Mines". In Brian Ballantyne & Paul Schwabe (ed.). Respiratory Protection. Principles and Applications. London, New York: Chapman & Hall. pp. 287–298. ISBN   978-0-412-22750-9.
  13. Myers, Warren; Peach, M.J. III (1983). "Performance measurements on a powered air-purifying respirator made during actual field use in a silica bagging operation". The Annals of Occupational Hygiene. 27 (3): 251–259. doi:10.1093/annhyg/27.3.251. ISSN   0003-4878. PMID   6314865 . Retrieved 10 July 2016.
  14. Que Hee, Shane; Lawrence, Philip (1983). "Inhalation Exposure of Lead in Brass Foundry Workers: The Evaluation of the Effectiveness of a Powered Air-Purifying Respirator and Engineering Controls". American Industrial Hygiene Association Journal. 44 (10): 746–751. doi:10.1080/15298668391405670. ISSN   1542-8117. PMID   6650396 . Retrieved 10 July 2016.
  15. Cecala, Andrew B.; Volkwein, Jon C.; Thomas, Edward D.; Charles W. Urban (1981). Protection Factors of the Airstream Helmet. Bureau of Mines Report No. 8591. p. 10.
  16. 1 2 3 4 Lenhart, Steven; Campbel, Donald (1984). "Assigned protection factors for two respirators types based upon workplace performance testing". The Annals of Occupational Hygiene. 28 (2): 173–182. doi:10.1093/annhyg/28.2.173. ISSN   0003-4878. PMID   6476685 . Retrieved 10 July 2016.
  17. 1 2 3 Myers, Warren; Peach III, Michael; Cutright, Ken; Iskander, Wafik (1984). "Workplace Protection Factor Measurements on Powered Air-Purifying Respirators at a Secondary Lead Smelter: Results and Discussion". American Industrial Hygiene Association Journal. 45 (10): 681–688. doi:10.1080/15298668491400449. ISSN   1542-8117. PMID   6496315.
  18. 1 2 Myers, Warren; Peach III, Michael; Cutright, Ken; Iskander, Wafik (1986). "Field Test of Powered Air-Purifying Respirators at a Battery Manufacturing Facility". Journal of the International Society for Respiratory Protection. 4 (1): 62–89. ISSN   0892-6298.
  19. Nancy J. Bollinger, Robert H. Schutz, ed. (1987). NIOSH Guide to Industrial Respiratory Protection. DHHS (NIOSH) Publication No 87-116. Cincinnati, Ohio: National Institute for Occupational Safety and Health. p. 305. doi:10.26616/NIOSHPUB87116.
  20. Miller, Donald; et al. (1987). NIOSH Respirator Decision Logic. DHHS (NIOSH) Publication No. 87-108. National Institute for Occupational Safety and Health. p. 61. doi:10.26616/NIOSHPUB87108 . Retrieved 16 July 2016.
  21. Occupational Safety and Health Administration, US Department of Labor (2009). "Assigned Protection Factors for the Revised Respiratory Protection Standard" (PDF). Retrieved 7 January 2020.
  22. Zhuang, Ziqing; Coffey, Christopher; Campbell, Donald; Lawrence, Robert; Myers, Warren (2003). "Correlation Between Quantitative Fit Factors and Workplace Protection Factors Measured in Actual Workplace Environments at a Steel Foundry". American Industrial Hygiene Association Journal. 64 (6): 730–738. doi:10.1080/15428110308984867. ISSN   1542-8117. PMID   14674806 . Retrieved 10 July 2016.
  23. Petryanov, Igor; Kashcheev, Victor; et al. (2015). ["Lepestok". Filterring facepieces] (in Russian) (2 ed.). Moscow: Nauka. p. 320. ISBN   978-5-02-039145-1.
  24. Hoover, Mark D.; Lackey, Jack R.; Vargo, George J. (2001). "Results and Discussion" (PDF). Independent Evaluation of The Lepestok Filtering Facepiece Respirator. PNNL-13581; LRRI-20001202. Albuquerque, NM: Lovelace Respiratory Research Institute, Pacific Northwest National Laboratory (U.S. Department of Energy). pp. 13–20. Retrieved 16 July 2016.
  25. Ogorodnikov, Boris; Pasukhin, Edward (2006). "[Respiratory protective devices]" (PDF). [Radioactive aerosols of the object "Ukryttya" (a review). Part 5. Means for sampling and analyses of aerosols. Radioactive aerosols in lungs]. Preprint 06-6 (in Russian). Chernobyl: National Academy of Sciences of Ukraine. Institute for safety problems of nuclear power plants. pp. 10–28. Retrieved 16 July 2016.
  26. Galushkin, B.A.; Gorbunov, S.V. (1990). "[The efficiency of a filtering matherial ФПП-15-1.5]". In Victor Kashcheev (ed.). [Abstracts of the III All-Union Conference "Experimental physiology, hygiene and personal protection of the person"] (in Russian). Moscow: The Ministry of Health of the USSR, Institute of Biophysics. pp. 12–13.
  27. Galushkin, B.A.; Gorbunov, S.V. (1990). "[Experimental studies to determine the protection factor of the filtering facepiece respirator "Lepestok-200" during emergency operations at the Chernobyl nuclear power plant ]". In Victor Kashcheev (ed.). [Abstracts of the III All-Union Conference "Experimental physiology, hygiene and personal protection of the person"] (in Russian). Moscow: The Ministry of Health of the USSR, Institute of Biophysics. pp. 11–12.
  28. British Standard BS 4275:1997 "Guide to implementing an effective respiratory protective device programme" (3rd ed.). London: British Standards Institution. 1997. ISBN   0-580-28915 X.
  29. 1 2 3 4 5 OSHA standard 29 CFR 1910.134 "Respiratory Protection"
  30. Colinet, Jay F.; Rider, James P.; Listak, Jeffrey M. (2010). Best Practices for Dust Control in Coal Mining. Information Circular 9517. DHHS (NIOSH) Publication No. 2010–110. John A. Organiscak, and Anita L. Wolfe. Pittsburgh, PA - Spokane, WA: National Institute for Occupational Safety and Health. p. 84. Retrieved 16 July 2016.
  31. Cecala, Andrew B.; O'Brien, Andrew D.; Schall, Joseph (2012). Dust Control Handbook for Industrial Minerals Mining and Processing. Report of Investigations 9689. DHHS (NIOSH) Publication No. 2012–112. Jay F. Colinet, William R. Fox, Robert J. Franta, Jerry Joy, Wm. Randolph Reed, Patrick W. Reeser, John R. Rounds, Mark J. Schultz. Pittsburgh, PA; Spokane, WA: National Institute for Occupational Safety and Health. p. 314. Retrieved 16 July 2016.
  32. Janssen, Larry; Bidwell, Jeanne (2007). "Performance of a Full Facepiece, Air-Purifying Respirator Against Lead Aerosols in a Workplace Environment". Journal of Occupational and Environmental Hygiene. 4 (2): 123–128. doi:10.1080/15459620601128845. ISSN   1545-9632. PMID   17175515. S2CID   15928287 . Retrieved 15 July 2016.
  33. 1 2 Ming-Tsang, Wu (2002). "Assessment of the Effectiveness of Respirator Usage in Coke Oven Workers". American Industrial Hygiene Association Journal. 63 (1): 72–75. doi:10.1080/15428110208984694. ISSN   1542-8117. PMID   11843430 . Retrieved 10 July 2016.
  34. Chang, Fu-Kuei; Chen, Mei-Lien; Cheng, Shu-Fang; Shih, Tung-Sheng; Mao, I-Fang (2007). "Evaluation of dermal absorption and protective effectiveness of respirators for xylene in spray painters". International Archives of Occupational and Environmental Health. 81 (2): 145–150. Bibcode:2007IAOEH..81..145C. doi:10.1007/s00420-007-0197-9. ISSN   0340-0131. PMID   17492305. S2CID   24442412 . Retrieved 16 July 2016.
  35. Lof, Agneta; Brohede, Christina; Gullstrand, Elisabeth; Lindstrom, Karin; Sollenberg, Jan; Wrangskog, Kent; Hagberg, Mats; Hedman, Birgitta Kolmodin (1993). "The effectiveness of respirators measured during styrene exposure in a plastic boat factory". International Archives of Occupational and Environmental Health. 65 (1): 29–34. Bibcode:1993IAOEH..65...29L. doi:10.1007/BF00586055. ISSN   0340-0131. PMID   8354572. S2CID   36237447 . Retrieved 16 July 2016.
  36. Clayton, Mike; Bancroft, B.; Rajan-Sithamparanadarajah, Bob (2002). "A Review of Assigned Protection Factors of Various Types and Classes of Respiratory Protective Equipment with Reference to their Measured Breathing Resistances". The Annals of Occupational Hygiene. 46 (6): 537–547. doi:10.1093/annhyg/mef071. ISSN   0003-4878. PMID   12176769.
  37. Bollinger, Nancy; Campbell, Donald; Coffey, Christopher (2004). "III. Respirator Selection Logic Sequence". NIOSH Respirator Selection Logic. DHHS (NIOSH) Publication No. 2005-100. NIOSH Respirator Policy Group; Heinz Ahlers, Roland BerryAnn, Frank Hearl, Richard Metzler, Teresa Seitz, Douglas Trout and Ralph Zumwalde. Cincinnati, OH: The National Institute for Occupational Safety and Health (NIOSH). pp. 3–16. doi:10.26616/NIOSHPUB2005100.
  38. Johnson, Alan; Myers, Warren; Colton, Craig; Birkner, J.S.; Campbell, C.E. (1992). "Review of respirator performance testing in the workplace: issues and concerns". American Industrial Hygiene Association Journal. 53 (11): 705–712. doi:10.1080/15298669291360409. ISSN   1542-8117. PMID   1442561 . Retrieved 10 July 2016.