X-ray emission spectroscopy

Last updated

X-ray emission spectroscopy (XES) is a form of X-ray spectroscopy in which a core electron is excited by an incident x-ray photon and then this excited state decays by emitting an x-ray photon to fill the core hole. The energy of the emitted photon is the energy difference between the involved electronic levels. The analysis of the energy dependence of the emitted photons is the aim of the X-ray emission spectroscopy. [1] [2] [3]

Contents

Fig.1: K-Beta Mainline and V2C K-Beta & VtC.PNG
Fig.1: K-Beta Mainline and V2C

There are several types of XES and can be categorized as non-resonant XES (XES), which includes -measurements, valence-to-core (VtC/V2C)-measurements, and ()-measurements, or as resonant XES (RXES or RIXS), which includes XXAS+XES 2D-measurement, high-resolution XAS, 2p3d RIXS, and Mössbauer-XES-combined measurements. [4] In addition, Soft X-ray emission spectroscopy (SXES) is used in determining the electronic structure of materials.

History

The first XES experiments were published by Lindh and Lundquist in 1924 [5]

Fig.2: Energy Level Diagram K-Lines Energy Level Diagramm K-Lines.jpeg
Fig.2: Energy Level Diagram K-Lines

In these early studies, the authors utilized the electron beam of an X-ray tube to excite core electrons and obtain the -line spectra of sulfur and other elements. Three years later, Coster and Druyvesteyn performed the first experiments using photon excitation. [6] Their work demonstrated that the electron beams produce artifacts, thus motivating the use of X-ray photons for creating the core hole. Subsequent experiments were carried out with commercial X-ray spectrometers, as well as with high-resolution spectrometers.

While these early studies provided fundamental insights into the electronic configuration of small molecules, XES only came into broader use with the availability of high intensity X-ray beams at synchrotron radiation facilities, which enabled the measurement of (chemically) dilute samples. [7] In addition to the experimental advances, it is also the progress in quantum chemical computations, which makes XES an intriguing tool for the study of the electronic structure of chemical compounds.

Henry Moseley, a British physicist was the first to discover a relation between the -lines and the atomic numbers of the probed elements. This was the birth hour of modern x-ray spectroscopy. Later these lines could be used in elemental analysis to determine the contents of a sample.

William Lawrence Bragg later found a relation between the energy of a photon and its diffraction within a crystal. The formula he established, says that an X-ray photon with a certain energy bends at a precisely defined angle within a crystal.

Equipment

Analyzers

A special kind of monochromator is needed to diffract the radiation produced in X-Ray-Sources. This is because X-rays have a refractive index n ≈ 1. Bragg came up with the equation that describes x-ray/neutron diffraction when those particles pass a crystal lattice.(X-ray diffraction)

For this purpose "perfect crystals" have been produced in many shapes, depending on the geometry and energy range of the instrument. Although they are called perfect, there are miscuts within the crystal structure which leads to offsets of the Rowland plane. These offsets can be corrected by turning the crystal while looking at a specific energy(for example: -line of copper at 8027.83eV). When the intensity of the signal is maximized, the photons diffracted by the crystal hit the detector in the Rowland plane. There will now be a slight offset in the horizontal plane of the instrument which can be corrected by increasing or decreasing the detector angle.

In the Von Hamos geometry, a cylindrically bent crystal disperses the radiation along its flat surface's plane and focuses it along its axis of curvature onto a line like feature.

Fig.3: Rowland Circle(Johann) with two orders Rowland Circle with two orders.png
Fig.3: Rowland Circle(Johann) with two orders

The spatially distributed signal is recorded with a position sensitive detector at the crystal's focusing axis providing the overall spectrum. Alternative wavelength dispersive concepts have been proposed and implemented based on Johansson geometry having the source positioned inside the Rowland circle, whereas an instrument based on Johann geometry has its source placed on the Rowland circle. [8] [9]

X-ray sources

X-ray sources are produced for many different purposes, yet not every X-ray source can be used for spectroscopy. Commonly used sources for medical applications generally generate very "noisy" source spectra, because the used cathode material must not be very pure for these measurements. These lines must be eliminated as much as possible to get a good resolution in all used energy ranges.

For this purpose normal X-ray tubes with highly pure tungsten, molybdenum, palladium, etc. are made. Except for the copper they are embedded in, they produce a relatively "white" spectrum. [10] Another way of producing X-rays are particle accelerators. The way they produce X-rays is from vectoral changes of their direction through magnetic fields. Every time a moving charge changes direction it has to give off radiation of corresponding energy. In X-ray tubes this directional change is the electron hitting the metal target (Anode) in synchrotrons it is the outer magnetic field accelerating the electron into a circular path.

There are many different kind of X-ray tubes and operators have to choose accurately depending on what it is, that should be measured.

Modern spectroscopy and the importance of -lines in the 21st Century

Today, XES is less used for elemental analysis, but more and more do measurements of -line spectra find importance, as the relation between these lines and the electronic structure of the ionized atom becomes more detailed.

If an 1s-Core-Electron gets excited into the continuum(out of the atoms energy levels in MO), electrons of higher energy orbitals need to lose energy and "fall" to the 1s-Hole that was created to fulfill Hund's Rule.(Fig.2) Those electron transfers happen with distinct probabilities. (See Siegbahn notation)

Scientists noted that after an ionization of a somehow bonded 3d-transition metal-atom the -lines intensities and energies shift with oxidation state of the metal and with the species of ligand(s). This gave way to a new method in structural analysis:

By high-resolution scans of these lines the exact energy level and structural configuration of a chemical compound can be determined. This is because there are only two major electron transfer mechanisms, if we ignore every transfer not affecting valence electrons. If we include the fact that chemical compounds of 3d-transition metals can either be high-spin or low-spin we get 2 mechanisms for each spin configuration. [4]

These two spin configurations determine the general shape of the and -mainlines as seen in figure one and two, while the structural configuration of electrons within the compound causes different intensities, broadening, tailing and piloting of the and -lines. [4] Although this is quite a lot of information, this data has to be combined with absorption measurements of the so-called "pre-edge" region. Those measurements are called XANES (X-ray absorption near edge structure).

Fig.4: XAS Measurement against HERFD XAS Measurement against HERFD.png
Fig.4: XAS Measurement against HERFD

In synchrotron facilities those measurement can be done at the same time, yet the experiment setup is quite complex and needs exact and fine tuned crystal monochromators to diffract the tangential beam coming from the electron storage ring. Method is called HERFD, which stands for High Energy Resolution Fluorescence Detection. The collection method is unique in that, after a collection of all wavelengths coming from "the source" called , the beam is then shone onto the sample holder with a detector behind it for the XANES part of the measurement. The sample itself starts to emit X-rays and after those photons have been monochromatized they are collected, too. Most setups use at least three crystal monochromators or more. The is used in absorption measurements as a part of the Beer-Lambert Law in the equation

where is the intensity of transmitted photons. The received values for the extinction are wavelength specific which therefore creates a spectrum of the absorption. The spectrum produced from the combined data shows clear advantage in that background radiation is almost completely eliminated while still having an extremely resolute view on features on a given absorption edge.(Fig.4)

In the field of development of new catalysts for more efficient energy storage, production and usage in form of hydrogen fuel cells and new battery materials, the research of the -lines is essential nowadays.

The exact shape of specific oxidation states of metals is mostly known, yet newly produced chemical compounds with the potential of becoming a reasonable catalyst for electrolysis, for example, are measured every day.

Several countries encourage many different facilities all over the globe in this special field of science in the hope for clean, responsible and cheap energy. [11]

Soft x-ray emission spectroscopy

Soft X-ray emission spectroscopy or (SXES) is an experimental technique for determining the electronic structure of materials.

Uses

X-ray emission spectroscopy (XES) provides a means of probing the partial occupied density of electronic states of a material. XES is element-specific and site-specific, making it a powerful tool for determining detailed electronic properties of materials.

Forms

Emission spectroscopy can take the form of either resonant inelastic X-ray emission spectroscopy (RIXS) or non-resonant X-ray emission spectroscopy (NXES). Both spectroscopies involve the photonic promotion of a core level electron, and the measurement of the fluorescence that occurs as the electron relaxes into a lower-energy state. The differences between resonant and non-resonant excitation arise from the state of the atom before fluorescence occurs.

In resonant excitation, the core electron is promoted to a bound state in the conduction band. Non-resonant excitation occurs when the incoming radiation promotes a core electron to the continuum. When a core hole is created in this way, it is possible for it to be refilled through one of several different decay paths. Because the core hole is refilled from the sample's high-energy free states, the decay and emission processes must be treated as separate dipole transitions. This is in contrast with RIXS, where the events are coupled, and must be treated as a single scattering process.

Properties

Soft X-rays have different optical properties than visible light and therefore experiments must take place in ultra high vacuum, where the photon beam is manipulated using special mirrors and diffraction gratings.

Gratings diffract each energy or wavelength present in the incoming radiation in a different direction. Grating monochromators allow the user to select the specific photon energy they wish to use to excite the sample. Diffraction gratings are also used in the spectrometer to analyze the photon energy of the radiation emitted by the sample.

See also

Related Research Articles

<span class="mw-page-title-main">Spectroscopy</span> Study involving matter and electromagnetic radiation

Spectroscopy is the field of study that measures and interprets electromagnetic spectra. In narrower contexts, spectroscopy is the precise study of color as generalized from visible light to all bands of the electromagnetic spectrum.

<span class="mw-page-title-main">X-ray photoelectron spectroscopy</span> Spectroscopic technique

X-ray photoelectron spectroscopy (XPS) is a surface-sensitive quantitative spectroscopic technique based on the photoelectric effect that can identify the elements that exist within a material or are covering its surface, as well as their chemical state, and the overall electronic structure and density of the electronic states in the material. XPS is a powerful measurement technique because it not only shows what elements are present, but also what other elements they are bonded to. The technique can be used in line profiling of the elemental composition across the surface, or in depth profiling when paired with ion-beam etching. It is often applied to study chemical processes in the materials in their as-received state or after cleavage, scraping, exposure to heat, reactive gasses or solutions, ultraviolet light, or during ion implantation.

<span class="mw-page-title-main">X-ray fluorescence</span> Emission of secondary X-rays from a material excited by high-energy X-rays

X-ray fluorescence (XRF) is the emission of characteristic "secondary" X-rays from a material that has been excited by being bombarded with high-energy X-rays or gamma rays. The phenomenon is widely used for elemental analysis and chemical analysis, particularly in the investigation of metals, glass, ceramics and building materials, and for research in geochemistry, forensic science, archaeology and art objects such as paintings.

<span class="mw-page-title-main">Emission spectrum</span> Frequencies of light emitted by atoms or chemical compounds

The emission spectrum of a chemical element or chemical compound is the spectrum of frequencies of electromagnetic radiation emitted due to electrons making a transition from a high energy state to a lower energy state. The photon energy of the emitted photons is equal to the energy difference between the two states. There are many possible electron transitions for each atom, and each transition has a specific energy difference. This collection of different transitions, leading to different radiated wavelengths, make up an emission spectrum. Each element's emission spectrum is unique. Therefore, spectroscopy can be used to identify elements in matter of unknown composition. Similarly, the emission spectra of molecules can be used in chemical analysis of substances.

<span class="mw-page-title-main">Synchrotron light source</span> Particle accelerator designed to produce intense x-ray beams

A synchrotron light source is a source of electromagnetic radiation (EM) usually produced by a storage ring, for scientific and technical purposes. First observed in synchrotrons, synchrotron light is now produced by storage rings and other specialized particle accelerators, typically accelerating electrons. Once the high-energy electron beam has been generated, it is directed into auxiliary components such as bending magnets and insertion devices in storage rings and free electron lasers. These supply the strong magnetic fields perpendicular to the beam that are needed to stimulate the high energy electrons to emit photons.

<span class="mw-page-title-main">Photoemission spectroscopy</span> Examining a substance by measuring electrons emitted in the photoelectric effect

Photoemission spectroscopy (PES), also known as photoelectron spectroscopy, refers to energy measurement of electrons emitted from solids, gases or liquids by the photoelectric effect, in order to determine the binding energies of electrons in the substance. The term refers to various techniques, depending on whether the ionization energy is provided by X-ray, XUV or UV photons. Regardless of the incident photon beam, however, all photoelectron spectroscopy revolves around the general theme of surface analysis by measuring the ejected electrons.

<span class="mw-page-title-main">X-ray spectroscopy</span> Technique to characterize materials using X-ray radiation

X-ray spectroscopy is a general term for several spectroscopic techniques for characterization of materials by using x-ray radiation.

<span class="mw-page-title-main">Stanford Synchrotron Radiation Lightsource</span> Research center at Stanford University

The Stanford Synchrotron Radiation Lightsource, a division of SLAC National Accelerator Laboratory, is operated by Stanford University for the Department of Energy. SSRL is a National User Facility which provides synchrotron radiation, a name given to electromagnetic radiation in the x-ray, ultraviolet, visible and infrared realms produced by electrons circulating in a storage ring at nearly the speed of light. The extremely bright light that is produced can be used to investigate various forms of matter ranging from objects of atomic and molecular size to man-made materials with unusual properties. The obtained information and knowledge is of great value to society, with impact in areas such as the environment, future technologies, health, biology, basic research, and education.

<span class="mw-page-title-main">X-ray absorption spectroscopy</span> Panel of different types of X-ray absorption spectroscopy requiring a synchrotron radiation facility

X-ray absorption spectroscopy (XAS) is a widely used technique for determining the local geometric and/or electronic structure of matter. The experiment is usually performed at synchrotron radiation facilities, which provide intense and tunable X-ray beams. Samples can be in the gas phase, solutions, or solids.

X-ray absorption near edge structure (XANES), also known as near edge X-ray absorption fine structure (NEXAFS), is a type of absorption spectroscopy that indicates the features in the X-ray absorption spectra (XAS) of condensed matter due to the photoabsorption cross section for electronic transitions from an atomic core level to final states in the energy region of 50–100 eV above the selected atomic core level ionization energy, where the wavelength of the photoelectron is larger than the interatomic distance between the absorbing atom and its first neighbour atoms.

<span class="mw-page-title-main">European XFEL</span>

The European X-Ray Free-Electron Laser Facility is an X-ray research laser facility commissioned during 2017. The first laser pulses were produced in May 2017 and the facility started user operation in September 2017. The international project with twelve participating countries; nine shareholders at the time of commissioning, later joined by three other partners, is located in the German federal states of Hamburg and Schleswig-Holstein. A free-electron laser generates high-intensity electromagnetic radiation by accelerating electrons to relativistic speeds and directing them through special magnetic structures. The European XFEL is constructed such that the electrons produce X-ray light in synchronisation, resulting in high-intensity X-ray pulses with the properties of laser light and at intensities much brighter than those produced by conventional synchrotron light sources.

Anomalous X-ray scattering is a non-destructive determination technique within X-ray diffraction that makes use of the anomalous dispersion that occurs when a wavelength is selected that is in the vicinity of an absorption edge of one of the constituent elements of the sample. It is used in materials research to study nanometer sized differences in structure.

X-ray Raman scattering (XRS) is non-resonant inelastic scattering of X-rays from core electrons. It is analogous to vibrational Raman scattering, which is a widely used tool in optical spectroscopy, with the difference being that the wavelengths of the exciting photons fall in the X-ray regime and the corresponding excitations are from deep core electrons.

<span class="mw-page-title-main">Gamma ray</span> Energetic electromagnetic radiation arising from radioactive decay of atomic nuclei

A gamma ray, also known as gamma radiation (symbol γ or ), is a penetrating form of electromagnetic radiation arising from the radioactive decay of atomic nuclei. It consists of the shortest wavelength electromagnetic waves, typically shorter than those of X-rays. With frequencies above 30 exahertz (3×1019 Hz), it imparts the highest photon energy. Paul Villard, a French chemist and physicist, discovered gamma radiation in 1900 while studying radiation emitted by radium. In 1903, Ernest Rutherford named this radiation gamma rays based on their relatively strong penetration of matter; in 1900 he had already named two less penetrating types of decay radiation (discovered by Henri Becquerel) alpha rays and beta rays in ascending order of penetrating power.

<span class="mw-page-title-main">Resonant inelastic X-ray scattering</span> Advanced X-ray spectroscopy technique

Resonant inelastic X-ray scattering (RIXS) is an advanced X-ray spectroscopy technique.

<span class="mw-page-title-main">Total absorption spectroscopy</span>

Total absorption spectroscopy is a measurement technique that allows the measurement of the gamma radiation emitted in the different nuclear gamma transitions that may take place in the daughter nucleus after its unstable parent has decayed by means of the beta decay process. This technique can be used for beta decay studies related to beta feeding measurements within the full decay energy window for nuclei far from stability.

Conversion electron Mössbauer spectroscopy (CEMS) is a Mössbauer spectroscopy technique based on conversion electron.

<span class="mw-page-title-main">Spectrometer</span> Used to measure spectral components of light

A spectrometer is a scientific instrument used to separate and measure spectral components of a physical phenomenon. Spectrometer is a broad term often used to describe instruments that measure a continuous variable of a phenomenon where the spectral components are somehow mixed. In visible light a spectrometer can separate white light and measure individual narrow bands of color, called a spectrum. A mass spectrometer measures the spectrum of the masses of the atoms or molecules present in a gas. The first spectrometers were used to split light into an array of separate colors. Spectrometers were developed in early studies of physics, astronomy, and chemistry. The capability of spectroscopy to determine chemical composition drove its advancement and continues to be one of its primary uses. Spectrometers are used in astronomy to analyze the chemical composition of stars and planets, and spectrometers gather data on the origin of the universe.

Electron orbital imaging is an X-ray synchrotron technique used to produce images of electron orbitals in real space. It utilizes the technique of X-ray Raman scattering (XRS), also known as Non-resonant Inelastic X-Ray Scattering (NIXS) to inelastically scatter electrons off a single crystal. It is an element specific spectroscopic technique for studying the valence electrons of transition metals.

References

  1. Rachel Ross (2018-12-05). "What Is X-Ray Spectroscopy?". livescience.com. Retrieved 2023-08-17.
  2. "X-ray Emission Spectroscopy - - Diamond Light Source". www.diamond.ac.uk. Retrieved 2023-08-17.
  3. "X-ray Spectroscopy | Division of Chemical Physics". www.chemphys.lu.se. Retrieved 2023-08-17.
  4. 1 2 3 S. DeBeer: Advanced X-Ray Spectroscopy (PDF) Juni 2016, last checked 26.02.2020
  5. O.Lundquist: About the -line spectra in X-Ray Emission Spectroscopy of sulfur and potassium (PDF) 1925, last checked 26.02.2020
  6. D.Coster & M.J. Druyvesteyn: About satellites in X-Ray Plot Lines (PDF) 1926, last checked 26.02.2020
  7. J. Nordgren and G. Bray: Soft x-ray emission spectroscopy using monochromatized synchrotron radiation 1988, last checked 21.07.2020
  8. D.Sokaras: A seven-crystal Johann-type hard x-ray spectrometer at the Stanford Synchrotron Radiation Lightsource 2013, last checked 26.02.2020
  9. D.B. Wittry: X-ray Crystal Spectrometers and Monochromatorsin Microanalysis 2001, last checked 26.02.2020
  10. "Types of X-ray tubes and high-voltage power supplies". Matsusada Precision. Tech Tips. 2021-11-02. Retrieved 2023-08-17.
  11. C. Dallera:Soft X-ray Emission Spectroscopy at ESRF Beamline 26 Based on a Helical Undulator 1996, last checked 21.07.2020