David and Lucile Packard Foundation Headquarters
General information
TypeOffice
Address343 Second Street, Los Altos, California, 94022, United States
Construction startedNovember 2009
CompletedJuly 2012
Cost$37.2 million
Owner David and Lucile Packard Foundation
Technical details
Floor area50,956 sq. ft
Design and construction
Architecture firmEHDD
Structural engineerTipping Mar
Civil engineerSherwood Design Engineers
Main contractorDPR Construction

The David and Lucile Packard Foundation Headquarters is the corporate headquarters of the David and Lucile Packard Foundation, located in Los Altos, California. The Packard Foundation was created in 1964 by David Packard and his wife Lucile Salter Packard, one of the top 100 grant-making foundations in the United States, with the goals of improving the lives of children, enabling the creative pursuit of science, advancing reproductive health, and conserving and restoring the Earth’s natural systems. The David and Lucile Packard Foundation Headquarters is designed by EHDD to be the largest net zero energy building in California, and it has successfully reduced the energy use by 65% over conventional buildings.

Contents

The design of the architecture took advantage of the California climate and environment, and adopted passive and bioclimatic strategies in searching for an integrated net zero energy building design. It was awarded as the top 10 green building in 2014, Net Zero Energy Building by The Living Building Challenge™ 2013, and LEED Platinum 2013. The synergy of the integration design for net zero energy is significant, which includes many aspects, for example, re-development site of brownfield, on-site energy production through photovoltaic, aggressive reduction in plug loads, a triple-element glazing system engineered, fabricated and installed by AGA (Architectural Glass and Aluminum), [1] plus all-electric heating system, chilled beams and radiant panels for cooling, high daylight autonomy, transportation management, and rainwater recycling.

Net Zero Energy Building design

The design strategies of the David and Lucile Packard Foundation Headquarters follow this Zero Energy Building Design guideline, and in the following paragraphs, they will be described in detail and in the order of design priority.

Basic building design

Location and climate

David and Lucile Packard Foundation Headquarters is located in Los Altos Northern California, on the south end of San Francisco Bay. Los Altos receives about 37 inches of rain annually, 263 sunny days per year. It has moderate temperature and humidity, the average high temperature in the summer is 78 degrees, and the average low temperature in the winter is 39 degrees .

Site design

David and Lucile Packard Foundation Headquarters is orientated 40 degrees off true north to fit in the urban fabric. The site orientation combined with multi-layering shading strategies made access to winter sun and avoid summer sun, at the same time allowed fresh air in the interior spaces through an operable façade. Instead of grouping the programs into one union block, the architect designed a center courtyard to bring sunlight and wind into more spaces.

Building on a previously developed, damaged, or polluted brownfield site, and designing the building so that it restores that site helps to mitigate previous environmental degradation. [2] David and Lucile Packard Foundation Headquarters set a good example for the reuse of brownfield. Before the development, the site was 97% impervious, covered in substandard, mostly unoccupied buildings and asphalt parking lots, and now it has reduced the imperviousness to 35% and the landscape is planted with local Californian vegetation. The design also took account the transportation needs in the community, the team developed a Transportation Demand Management Plan (TDMP) to not only reduce the demand for individual car parking but also offers alternatives for commuting.

Insulation, windows, and shading

The building has high standard insulation design, R-24 walls and roof and triple-element glazing (R-7.7). Occupants are able to adjust and control the environment by operating the windows and doors with a dashboard guidance showing when is the good timing to open and close windows depending on the outdoor temperature, wind speed, wind direction and relative humidity. The dimensions and angles of the shading devices were calculated from the locations of the sun in different seasons. The horizontal shading blocks the high summer sun and allows low winter sun to enter the interior of the building, and other devices are built into the design with elements such as trees, balconies, and trellis, which create a rich layering of lighting shades.

Materials

  • 95% of materials from deconstruction were diverted from landfill
  • Wood/steel hybrid structure, wood frame walls and all wood was FSC (Forest Stewardship Council)-certified
  • Less embodied energy materials, such as 70% replacement-cement-for-slag concrete
  • Material sourcing: wood veneer sourced from Eucalyptus trees felled during the Doyle Drive rebuilding project in San Francisco, California. Exterior wood is FSC-certified western red cedar. Stone is Mt. Moriah from the border of Utah and Nevada, within a 500-mile radius from the site. The exterior copper is 75% recycled, with a long life span and integral finish. Pineapples are a delicacy in Northern Guatemala

Passive systems

Heating, cooling, and lighting

The accessibility of the sunlight is one of the key elements affect the positions and shapes of the building. Two 40-foot wide offices were placed apart to create a central zone for sunlight to enter from multiple facades in the building. The narrow plan allows sufficient daylight to reach deeper into the office spaces, and increase the daylight autonomy. Increase in daylight autonomy reduces 30% of the energy consumption from artificial lighting compared to a standard commercial building. The high transmittance of daylight in the winter (shading will block the direct sunlight in the summer) will also increase the heat gain and potentially reduce the demand for heating. Interior blinds are user-controlled to improve visual comfort, and it will rise automatically in the evening. The artificial light will dim or brighten up according to the change of daylighting.

The building is monitored by indoor sensors that send direct reminders to occupants to open the windows when natural ventilation mode is on.

Water recycling

Rainwater from the roof is routed to a 20,000-gallon underground cistern to meet 90% of toilet flushing and 60% of irrigation demand. The cistern overflows into a detention pond minimize storm water reaching the public storm system, and the storm water peak flow rates and volumes are reduced approximately 50% from pre-project levels.

Mechanical design

Heating and cooling

In the winter, when the temperature drops to a certain degree, the building will be preheated to 23 °C (74 °F) in the early morning by the combination of air handlers and heat water beams in specific areas in the office spaces. And during the working hours, the heater will be turned off and the building heating will be fully relied on the internal heat gain from the computers, printers, and heat generated from the human bodies.

Heating demand is larger than cooling, as the summer temperature is pretty moderate in Los Altos. Water is stored and cooled in two 25,000 gallons underground tanks, and in the morning, it is pumped into the chilled beams to spread out to specific interior spaces. Besides chilled beams, there are three air handling units. Chilled beam system is designed with variable speed pumps and 130° angled pipes, which reduce the energy loss due to friction from the water flow compared to chilled beam system with typical angle pipes. This result is 75% reduction in ductwork and 75% reduction in pump energy, and the total cooling energy is reduced 90% from a typical chiller and VAV system.

Renewable energy

Despite the orientation and slope of the roof is not customized for solar collection, the photovoltaic production most of the time covers 100% of the building consumption. In the first year of operation, the building was energy positive with a net energy use intensity (EUI) of −4 thousand British thermal units per square foot (−45  MJ / m2 ) per year, and total EUI of 22 thousand British thermal units per square foot (250 MJ/m2) per year.

Occupancy survey report

The building received 97% in overall comfort satisfaction in the occupancy survey report conducted by the Center for Built Environment. The survey also shows that 92% of the people are satisfied with air quality, 91% in cleanliness and maintenance, 76% in lighting, 86% in office furnishings, 80% in office layout, 73% in thermal comfort, and 60% in acoustic quality . Acoustic satisfaction is comparatively low due to open areas in the office space and hard surfaces of radiant floors and ceilings; people concerned about overhearing private conversation on the phone and with the neighbors. Consistently reflecting the same concern of open areas, the office layout survey also shows that people think the partitions and walls are too low or too transparent and feel the lack privacy in the working spaces.

Awards

See also

Related Research Articles

<span class="mw-page-title-main">Solar energy</span> Radiant light and heat from the Sun, harnessed with technology

Solar energy is radiant light and heat from the Sun that is harnessed using a range of technologies such as solar power to generate electricity, solar thermal energy, and solar architecture. It is an essential source of renewable energy, and its technologies are broadly characterized as either passive solar or active solar depending on how they capture and distribute solar energy or convert it into solar power. Active solar techniques include the use of photovoltaic systems, concentrated solar power, and solar water heating to harness the energy. Passive solar techniques include orienting a building to the Sun, selecting materials with favorable thermal mass or light-dispersing properties, and designing spaces that naturally circulate air.

A Trombe wall is a massive equator-facing wall that is painted a dark color in order to absorb thermal energy from incident sunlight and covered with a glass on the outside with an insulating air-gap between the wall and the glaze. A Trombe wall is a passive solar building design strategy that adopts the concept of indirect-gain, where sunlight first strikes a solar energy collection surface in contact with a thermal mass of air. The sunlight absorbed by the mass is converted to thermal energy (heat) and then transferred into the living space.

<span class="mw-page-title-main">Passive solar building design</span> Architectural engineering that uses the Suns heat without electric or mechanical systems

In passive solar building design, windows, walls, and floors are made to collect, store, reflect, and distribute solar energy, in the form of heat in the winter and reject solar heat in the summer. This is called passive solar design because, unlike active solar heating systems, it does not involve the use of mechanical and electrical devices.

<span class="mw-page-title-main">Solar thermal energy</span> Technology using sunlight for heat

Solar thermal energy (STE) is a form of energy and a technology for harnessing solar energy to generate thermal energy for use in industry, and in the residential and commercial sectors.

<span class="mw-page-title-main">Low-energy house</span> House designed for reduced energy use

A low-energy house is characterized by an energy-efficient design and technical features which enable it to provide high living standards and comfort with low energy consumption and carbon emissions. Traditional heating and active cooling systems are absent, or their use is secondary. Low-energy buildings may be viewed as examples of sustainable architecture. Low-energy houses often have active and passive solar building design and components, which reduce the house's energy consumption and minimally impact the resident's lifestyle. Throughout the world, companies and non-profit organizations provide guidelines and issue certifications to guarantee the energy performance of buildings and their processes and materials. Certifications include passive house, BBC—Bâtiment Basse Consommation—Effinergie (France), zero-carbon house (UK), and Minergie (Switzerland).

Displacement ventilation (DV) is a room air distribution strategy where conditioned outdoor air is supplied at a low velocity from air supply diffusers located near floor level and extracted above the occupied zone, usually at ceiling height.

<span class="mw-page-title-main">Zero-energy building</span> Energy efficiency standard for buildings

A Zero-Energy Building (ZEB), also known as a Net Zero-Energy (NZE) building, is a building with net zero energy consumption, meaning the total amount of energy used by the building on an annual basis is equal to the amount of renewable energy created on the site or in other definitions by renewable energy sources offsite, using technology such as heat pumps, high efficiency windows and insulation, and solar panels.

Renewable heat is an application of renewable energy referring to the generation of heat from renewable sources; for example, feeding radiators with water warmed by focused solar radiation rather than by a fossil fuel boiler. Renewable heat technologies include renewable biofuels, solar heating, geothermal heating, heat pumps and heat exchangers. Insulation is almost always an important factor in how renewable heating is implemented.

<span class="mw-page-title-main">Solar gain</span> Solar energy effect

Solar gain is the increase in thermal energy of a space, object or structure as it absorbs incident solar radiation. The amount of solar gain a space experiences is a function of the total incident solar irradiance and of the ability of any intervening material to transmit or resist the radiation.

A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements. There are two types of chilled beams, a Passive Chilled Beam (PCB) and an Active Chilled Beam (ACB). They both consist of pipes of water (fin-and-tube) that pass through a heat exchanger contained in a case suspended from, or recessed in, the ceiling. As the beam cools the air around it, the air becomes denser and falls to the floor. It is replaced by warmer air moving up from below, causing a constant passive air movement called convection, to cool the room. The active beam consists of air duct connections, induction nozzles, hydronic heat transfer coils, supply outlets and induced air inlets. It contains an integral air supply that passes through nozzles, and induces air from the room to the cooling coil. For this reason, it has a better cooling capacity than the passive beam. Instead, the passive beam provides space cooling without the use of a fan and it is mainly done by convection. Passive beams can be either exposed or recessed. The passive approach can provide higher thermal comfort levels, while the active approach uses the momentum of ventilation air that enters at relatively high velocity to induce the circulation of room air through the unit. A chilled beam is similar in appearance to a VRF unit.

<span class="mw-page-title-main">Council House 2</span> Office in Melbourne, Australia

Council House 2 (also known as CH2), is an office building located at 240 Little Collins Street in the Melbourne central business district, Australia. It is used by the City of Melbourne council, and in April 2005, became the first purpose-built office building in Australia to achieve a maximum Six Green Star rating, certified by the Green Building Council of Australia. CH2 officially opened in August 2006.

<span class="mw-page-title-main">Tower at PNC Plaza</span> High-rise building in Pittsburgh, Pennsylvania

The Tower at PNC Plaza is a 33-story skyscraper in Pittsburgh, Pennsylvania. It is the corporate headquarters of the PNC Financial Services Group and has approximately 800,000 square feet (74,000 m2), standing 33 stories tall. Nearby buildings totaling 37,000 square feet (3,400 m2), were purchased by PNC and deconstructed to make space for the Tower at PNC Plaza. It is located at the intersection of Fifth Avenue and Wood Street, where PNC and its predecessors have been based since 1858.

Sustainable refurbishment describes working on existing buildings to improve their environmental performance using sustainable methods and materials. A refurbishment or retrofit is defined as: "any work to a building over and above maintenance to change its capacity, function or performance' in other words, any intervention to adjust, reuse, or upgrade a building to suit new conditions or requirements". Refurbishment can be done to a part of a building, an entire building, or a campus. Sustainable refurbishment takes this a step further to modify the existing building to perform better in terms of its environmental impact and its occupants' environment.

<span class="mw-page-title-main">Swanston Academic Building</span> Education in Victoria, Australia

The Swanston Academic building is an RMIT building designed by the architecture firm Lyons and is located on Swanston Street in Melbourne across from Peter Corrigan designed building 8 and ARM's Storey Hall. Construction began in September 2010 and was completed in September 2012. The budget for the SAB was $200,000,000. The new building contains 35,000 square metres (380,000 sq ft) of floor space, is 11 storeys high and provides 6 large lecture theatres for students. The colourful building is intended to reflect the cities surroundings in the façade. “The idea is to wear the ‘cloak’ of the city”.

<span class="mw-page-title-main">The Terry Thomas Building</span> Office building in Seattle, Washington

The Terry Thomas Building, located in the South Lake Union neighborhood of Seattle, Washington is a sustainable, LEED-certified office building completed in 2008. The Terry Thomas is Seattle's first commercial office building structure developed in decades without central air conditioning. It was designed by Seattle-based architectural firm Weber Thompson, who also designed the interiors of the building and use it as their headquarters.

<span class="mw-page-title-main">DPR Construction</span> American construction firm

DPR Construction is a commercial general contractor and construction management firm based in Redwood City, California. The privately-held, employee-owned company has 30 offices throughout the United States and specializes in technically complex and sustainable projects for the advanced technology/mission-critical, life sciences, healthcare, higher education and commercial office markets. International offices located in Europe and Asia.

<span class="mw-page-title-main">Radiant heating and cooling</span> Category of HVAC technologies

Radiant heating and cooling is a category of HVAC technologies that exchange heat by both convection and radiation with the environments they are designed to heat or cool. There are many subcategories of radiant heating and cooling, including: "radiant ceiling panels", "embedded surface systems", "thermally active building systems", and infrared heaters. According to some definitions, a technology is only included in this category if radiation comprises more than 50% of its heat exchange with the environment; therefore technologies such as radiators and chilled beams are usually not considered radiant heating or cooling. Within this category, it is practical to distinguish between high temperature radiant heating, and radiant heating or cooling with more moderate source temperatures. This article mainly addresses radiant heating and cooling with moderate source temperatures, used to heat or cool indoor environments. Moderate temperature radiant heating and cooling is usually composed of relatively large surfaces that are internally heated or cooled using hydronic or electrical sources. For high temperature indoor or outdoor radiant heating, see: Infrared heater. For snow melt applications see: Snowmelt system.

<span class="mw-page-title-main">David Brower Center</span>

The David Brower Center is a nonprofit space located in downtown Berkeley, California, containing three floors of office space, a gallery focusing primarily on environmental and social art, conference facilities, a 178-seat theater, and a restaurant, Gather. It was named to honor David Brower, a Berkeley native who was the first executive director of the Sierra Club and a backer of Marion Edey’s founding of the League of Conservation Voters. The center is part of a larger mixed use development that includes the Oxford Plaza. The David Brower Center's mission is to "inspire and nurture current and future generations of leaders, with the goal of making sustainable thinking and practices mainstream."

Passive survivability refers to a building's ability to maintain critical life-support conditions in the event of extended loss of power, heating fuel, or water. This idea proposes that designers should incorporate ways for a building to continue sheltering inhabitants for an extended period of time during and after a disaster situation, whether it be a storm that causes a power outage, a drought which limits water supply, or any other possible event.

<span class="mw-page-title-main">Quadruple glazing</span> Type of insulated glazing

Quadruple glazing is a type of insulated glazing comprising four glass panes, commonly equipped with low emissivity coating and insulating gases in the cavities between the glass panes. Quadruple glazing is a subset of multipane (multilayer) glazing systems. Multipane glazing with up to six panes is commercially available.

References

  1. Glass Magazine, "Most Innovated Energy Efficient Glass Project ", Mobile Glass Magazine page 30, July 2013
  2. Allen & Iano, Edward & Joseph. Fundamentals of Building Construction (Sixth ed.). Wiley. p. 39. ISBN   978-1-118-13891-5.

37°22′35″N122°06′53″W / 37.37645°N 122.11461°W / 37.37645; -122.11461