Insulating glass (IG) consists of two or more glass window panes separated by a space to reduce heat transfer across a part of the building envelope. A window with insulating glass is commonly known as double glazing or a double-paned window, triple glazing or a triple-paned window, or quadruple glazing or a quadruple-paned window, depending upon how many panes of glass are used in its construction.
Insulating glass units (IGUs) are typically manufactured with glass in thicknesses from 3 to 10 mm (1/8" to 3/8"). Thicker glass is used in special applications. Laminated or tempered glass may also be used as part of the construction. Most units are produced with the same thickness of glass on both panes but special applications such as acoustic attenuation or security may require different thicknesses of glass to be incorporated in a unit.
The space in between the panes provides the bulk of the insulation effect and may be filled with air, but argon is often used as it gives better insulation, or sometimes different gases or even a vacuum [1] are employed.
Fitting a second pane of glass to improve insulation began in Scotland, Germany, and Switzerland in the 1870s. [2]
Insulating glass is an evolution from older technologies known as double-hung windows and storm windows. Traditional double-hung windows used a single pane of glass to separate the interior and exterior spaces.
Traditional storm windows and screens are relatively time-consuming and labor-intensive, requiring removal and storage of the storm windows in the spring and reinstallation in the fall and storage of the screens. The weight of the large storm window frame and glass makes replacement on upper-stories of tall buildings a difficult task requiring repeatedly climbing a ladder with each window and trying to hold the window in place while securing retaining clips around the edges. However, current reproductions of these old-style storm windows can be made with detachable glass in the bottom pane that can be replaced with a detachable screen when desired. This eliminates the need for changing the entire storm window according to the seasons.
Insulated glazing (IG) forms a very compact multi-layer sandwich of air and glass, which eliminates the need for storm windows. Screens may also be left installed year-round with insulated glazing, and they can be installed in a manner that permits installation and removal from inside the building, eliminating the requirement to climb up the exterior of the house to service the windows. It is possible to retrofit insulated glazing into traditional double-hung frames, though this would require significant modification to the wood frame due to the increased thickness of the IG assembly.
Modern window units with IG typically completely replace the older double-hung unit and include other improvements such as better sealing between the upper and lower windows and spring-operated weight balancing that removes the need for large hanging weights inside the wall next to the windows, allowing for more insulation around the window and reducing air leakage. IG provides robust protection against the sun and keeps the house cool in the hot summer and warm in winter. The spring-operated balancing mechanisms also typically permit the top of the windows to swing inward, permitting cleaning of the exterior of the IG window from inside the building.
The insulating glazing unit, consisting of two glass panes bound together into a single unit with a seal between the edges of the panes, was patented in the United States by Thomas Stetson in 1865. [3] It was developed into a commercial product in the 1930s, when several patents were filed, and a product was announced by the Libbey-Owens-Ford Glass Company in 1944. [4] Their product was sold under the Thermopane brand name, which had been registered as a trademark in 1941. The Thermopane technology differs significantly from contemporary IGUs. The two panes of glass were welded together by a glass seal, and the two panes were separated by less than the 0.5 inches (1.3 cm) typical of modern units. [5] The brand name Thermopane has entered the vocabulary of the glazing industry as the genericized trademark for any IGU.[ citation needed ]
Single pane glass is a very poor insulator (R-value of around 1, RSI below 0.2), so single panes provide very little insulation. Glass coatings are frequently employed such as partially reflective or colored coatings to reduce insolation, and coatings to reflect infrared.
Low emissivity glass (low E glass) is a commercially available option for IGU construction. Low E glass is made by applying a Low E coating to a pane of glass. These are generally metallic coatings, usually applied onto the second or third glass surfaces of the unit, that have the effect of reflecting infrared light, and blocking or attenuating portions of the ultraviolet and visible light spectra. This can significantly reduce the solar gain of the IGU, which impacts both the thermal performance (R-value) and the Solar Heat Gain Coefficient (SHGC). Two types of low E coatings are available: hard coatings and soft coatings. Hard coatings are produced using tin oxide that is applied when the glass is still hot, and is absorbed into the glass, and are hard wearing and usually cheaper. Soft coatings are vacuum-sputtered onto the glass surface and have higher performance but are easily oxidized and damaged, and thus have to be protected by an inert gas fill. [6]
The glass panes are separated by a "spacer". A spacer, which may be of the warm edge type, is the piece that separates the two panes of glass in an insulating glass system, and seals the gas space between them. The first spacers were made primarily of steel and aluminum, which manufacturers thought provided more durability, and their lower price means that they remain common.
However, metal spacers conduct heat (unless the metal is thermally improved), undermining the ability of the insulated glass unit (IGU) to reduce heat flow. It may also result in water or ice forming at the bottom of the sealed unit because of the sharp temperature difference between the window and surrounding air. To reduce heat transfer through the spacer and increase overall thermal performance, manufacturers may make the spacer out of a less-conductive material such as structural foam. A spacer made of aluminum that also contains a highly structural thermal barrier reduces condensation on the glass surface and improves insulation, as measured by the overall U-value.
An older and established way to improve insulation performance is to replace air in the space with a lower thermal conductivity gas. Gas convective heat transfer is a function of viscosity and specific heat. Monatomic gases such as argon, krypton and xenon are often used since (at normal temperatures) they do not carry heat in rotational modes, resulting in a lower heat capacity than poly-atomic gases. Argon has a thermal conductivity 67% that of air, krypton has about half the conductivity of argon. [7] Argon is almost 1% of the atmosphere and isolated at a moderate cost. Krypton and xenon are only trace components of the atmosphere and very expensive. All of these "noble" gases are non-toxic, clear, odorless, chemically inert, and commercially available because of their widespread application in industry. Some manufacturers also offer sulfur hexafluoride as an insulating gas, especially to insulate sound. It has only 2/3 the conductivity of argon, but it is stable, inexpensive and dense. However, sulfur hexafluoride is an extremely potent greenhouse gas that contributes to global warming. In Europe, SF
6 falls under the F-Gas directive which ban or control its usage for several applications. Since 1 January 2006, SF
6 is banned as a tracer gas and in all applications except high-voltage switchgear. [8]
In general, the more effective a fill gas is at its optimum thickness, the thinner the optimum thickness is. For example, the optimum thickness for krypton is lower than for argon, and lower for argon than for air. [9] However, since it is difficult to determine whether the gas in an IGU has become mixed with air at time of manufacture (or becomes mixed with air once installed), many designers prefer to use thicker gaps than would be optimum for the fill gas if it were pure. Argon is commonly used in insulated glazing as it is the most affordable. Krypton, which is considerably more expensive, is not generally used except to produce very thin double glazing units or extremely high performance triple-glazed units. Xenon has found very little application in IGUs because of cost. [10]
Vacuum technology is also used in some non-transparent insulation products called vacuum insulated panels.
IGUs are often manufactured on a made to order basis on factory production lines, but standard units are also available. The width and height dimensions, the thickness of the glass panes and the type of glass for each pane as well as the overall thickness of the unit must be supplied to the manufacturer. On the assembly line, spacers of specific thicknesses are cut and assembled into the required overall width and height dimensions and filled with desiccant. On a parallel line, glass panes are cut to size and washed to be optically clear.
An adhesive, primary sealant (polyisobutylene) is applied to the face of the spacer on each side and the panes pressed against the spacer. If the unit is gas-filled, two holes are drilled into the spacer of the assembled unit, lines are attached to draw out the air out of the space and replacing it (or leaving just vacuum) with the desired gas. The lines are then removed and holes sealed to contain the gas. The more modern technique is to use an online gas filler, which eliminates the need to drill holes in the spacer. The purpose of primary sealant is to keep insulating gas from escaping and water vapor from entering. The units are then enveloped on the edge side using either polysulfide or silicone sealant or similar material as secondary sealant which restraints movements of the rubbery-plastic primary sealant. The desiccant will remove traces of humidity from the air space so that no water appears on the inside faces (no condensation) of the glass panes facing the air space during cold weather. Some manufacturers have developed specific processes that combine the spacer and desiccant into a single step application system.
The maximum insulating efficiency of a standard IGU is determined by the thickness of the space. Greater space increases the insulation value up to a point, but eventually with a large enough gap, convection currents begin to flow carrying heat between the panes within the unit. Typically, most sealed units achieve maximum insulating values using a space of 16–19 mm (0.63–0.75 in) when measured at the centre of the IGU. [11]
IGU thickness is a compromise between maximizing insulating value and the ability of the framing system used to carry the unit. Some residential and most commercial glazing systems can accommodate the ideal thickness of a double-paned unit. Issues arise with the use of triple glazing to further reduce heat loss in an IGU. The combination of thickness and weight results in units that are too unwieldy for most residential or commercial glazing systems, particularly if these panes are contained in moving frames or sashes.
This trade-off does not apply to vacuum insulated glass (VIG), or evacuated glazing, [13] as heat loss due to convection is eliminated, leaving radiation losses and conduction through the edge seal and required supporting pillars over the face area. [14] [15] These VIG units have most of the air removed from the space between the panes, leaving a nearly-complete vacuum. VIG units which are currently on the market are hermetically sealed along their perimeter with solder glass, that is, a glass frit (powdered glass) having a reduced melting point is heated to join the components. This creates a glass seal that experiences increasing stress with increasing temperature differential across the unit. This stress may limit the maximum allowable temperature differential. One manufacturer provides a recommendation of 35 °C. Closely spaced pillars are required to reinforce the glazing to resist the pressure of the atmosphere. Pillar spacing and diameter limited the insulation achieved by designs available beginning in the 1990s to R = 4.7 h·°F·ft2/BTU (0.83 m2·K/W) no better than high quality double glazed insulated glass units. Recent products claim performance of R = 14 h·°F·ft2/BTU (2.5 m2·K/W) which exceeds triple glazed insulated glass units. [15] The required internal pillars exclude applications where an unobstructed view through the glazing unit is desired, i.e. most residential and commercial windows, and refrigerated food display cases. VIG equipped windows, however, under-perform due to intense edge heat transfer. [12]
The insulation effectiveness can be expressed as an R-value or RSI value. The higher the value, the greater is its resistance to heat transfer. A standard IGU consisting of clear uncoated panes of glass (or lights) with air in the cavity between the lights typically has an RSI-value of 0.35 K·m2/W.
Using US customary units, a rule of thumb in standard IGU construction is that each change in the component of the IGU results in an increase of 1 R-value to the efficiency of the unit. Adding argon gas increases the efficiency to about R-3. Using low emissivity glass on surface #2 will add another R-value. Properly designed triple-glazed IGUs with low emissivity coatings on surfaces #2 and #4 and filled with argon gas in the cavities. Certain multi-chambered IG units result in R-values as high as R-24. Vacuum Insulating Glass (VIG) units result in R-values as high as R-15 (center of glass). Combining a VIG unit with another glass pane and warm edge spacer result in R-18 (center of glass) or more depending upon the low-e coating(s). Double VIG units with warm edge spacer reach R-25 (center of glass) or more depending upon low-e coatings and other factors.
Additional layers of glazing provide the opportunity for improved insulation. While the standard double glazing is most widely used, triple glazing is not uncommon, and quadruple glazing is produced for cold environments such as Alaska or Scandinavia. [16] [17] Even quintuple and six-pane glazing (four or five cavities) is available - with mid-pane insulation factors equivalent to walls. [18] [19] [20]
In some situations the insulation is in reference to noise mitigation. In these circumstances a large air space improves the noise insulation quality or sound transmission class. Asymmetric double glazing, using different thicknesses of glass rather than the conventional symmetrical systems (equal glass thicknesses used for both lights) will improve the acoustic attenuation properties of the IGU. If standard air spaces are used, sulfur hexafluoride can be used to replace or augment an inert gas [21] and improve acoustical attenuation performance.
Other glazing material variations affect acoustics. The most widely used glazing configurations for sound dampening include laminated glass with varied thickness of the interlayer and thickness of the glass. Including a structural, thermally improved aluminum thermal barrier air spacer in the insulating glass can improve acoustical performance by reducing the transmission of exterior noise sources in the fenestration system.
Reviewing the glazing system components, including the air space material used in the insulating glass, can ensure overall sound transmission improvement.
Transmittance is a measure of how much visible light is passed by the glass expressed as a fraction. Some of the light will also be absorbed and reflected.
Some types of light include radio waves. Notably, many low-e glass and semi-reflective metalised coatings greatly attenuate Wi-Fi and cell phone signals.[ citation needed ]
The life of an IGU varies depending on the quality of materials used, size of gap between inner and outer pane, temperature differences, workmanship and location of installation both in terms of facing direction and geographic location, as well as the treatment the unit receives. IG units typically last from 10 to 25 years, with windows facing the equator often lasting less than 12 years. IGUs typically carry a warranty for 10 to 20 years depending upon the manufacturer. If IGUs are altered (such as installation of a window insulation film) the warranty may be voided by the manufacturer.
The Insulating Glass Manufacturers Alliance (IGMA) [22] undertook an extensive study to characterize the failures of commercial insulating glass units over a 25-year period.
For a standard construction IG unit, condensation collects between the layers of glass when the perimeter seal has failed and when the desiccant has become saturated, and can generally only be eliminated by replacing the IGU. Seal failure and subsequent replacement results in a significant factor in the overall cost of owning IGUs. [23]
Large temperature differences between the inner and outer panes stress the spacer adhesives, which can eventually fail. Units with a small gap between the panes are more prone to failure because of the increased stress.
Atmospheric pressure changes combined with wet weather can, in rare cases, eventually lead to the gap filling with water.
The flexible sealing surfaces preventing infiltration around the window unit can also degrade or be torn or damaged. Replacement of these seals can be difficult to impossible, due to IG windows commonly using extruded channel frames without seal retention screws or plates. Instead, the edge seals are installed by pushing an arrow-shaped indented one-way flexible lip into a slot on the extruded channel, and often cannot be easily extracted from the extruded slot to be replaced.
In Canada, since the beginning of 1990, there are some companies offering servicing of failed IG units. They provide open ventilation to the atmosphere by drilling hole(s) in the glass and/or spacer. This solution often reverses the visible condensation, but cannot clean the interior surface of the glass and staining that may have occurred after long-term exposure to moisture. They may offer a warranty from 5 to 20 years. This solution lowers the insulating value of the window, but it can be a "green" solution when the window is still in good condition. If the IG unit had a gas fill (e.g. argon or krypton or a mixture) the gas is naturally dissipated and the R-value suffers.
Since 2004, there are also some companies offering the same restoration process for failed double-glazed units [24] in the UK, and there is one company offering restoration of failed IG units in Ireland since 2010.
Temperature differences across the surface of glass panes can lead to cracks in the glass. [25] This may occur where the glass is partially shaded and partially heated from the sunlight. Tinted glass increases heating and thermal stress, while annealing reduces internal stress built into the glass during manufacturing.
Thermal expansion creates internal pressure, or stress, where expanding warm material is restrained by cooler material. Typically cracks initiate and propagate from the narrow shaded cut edge where the glass is cooler and minute grooves and notches cause stress concentration. Glass thickness has no direct effect on thermal cracking in windows because both thermal stress and material strength are proportional to thickness. Annealed and tempered glass is usually more resistant to cracking.
Given the thermal properties of the sash, frame, and sill, and the dimensions of the glazing and thermal properties of the glass, the heat transfer rate for a given window and set of conditions can be calculated. This can be calculated in kW (kilowatts), but more usefully for cost benefit calculations can be stated as kWh pa (kilowatt hours per annum), based on the typical conditions over a year for a given location. [26]
The glass panels in double-glazed windows transmit heat in both directions by radiation, through the glazing by conduction and across the gap between the panes by convection, by conduction through the frame, and by infiltration around the perimeter seals and the frame's seal to the building. The actual rates will vary with the conditions throughout the year, and while solar gain may be much welcomed in the winter (depending on local climate), it may result in increased air conditioning costs in the summer. Unwanted heat transfer can be mitigated by for example using curtains at night in the winter and using sun shades during the day in the summer. In an attempt to provide a useful comparison between alternative window constructions the British Fenestration Rating Council have defined a "Window Energy Rating" WER, ranging from A for the best down through B and C etc. This takes into account a combination of the heat loss through the window (U value, the reciprocal of R-value), the solar gain (g value), and loss through air leakage around the frame (L value). For example, an A Rated window will in a typical year gain as much heat from solar gain as it loses in other ways (however the majority of this gain will occur during the summer months, when the heat may not be needed by the building occupant). This provides better thermal performance than a typical wall. [24]
Window rating programs and certifications:
A window is an opening in a wall, door, roof, or vehicle that allows the exchange of light and may also allow the passage of sound and sometimes air. Modern windows are usually glazed or covered in some other transparent or translucent material, a sash set in a frame in the opening; the sash and frame are also referred to as a window. Many glazed windows may be opened, to allow ventilation, or closed, to exclude inclement weather. Windows may have a latch or similar mechanism to lock the window shut or to hold it open by various amounts.
In passive solar building design, windows, walls, and floors are made to collect, store, reflect, and distribute solar energy, in the form of heat in the winter and reject solar heat in the summer. This is called passive solar design because, unlike active solar heating systems, it does not involve the use of mechanical and electrical devices.
Thermal insulation is the reduction of heat transfer between objects in thermal contact or in range of radiative influence. Thermal insulation can be achieved with specially engineered methods or processes, as well as with suitable object shapes and materials.
In building design, thermal mass is a property of the mass of a building that enables it to store heat and provide inertia against temperature fluctuations. It is sometimes known as the thermal flywheel effect. The thermal mass of heavy structural elements can be designed to work alongside a construction's lighter thermal resistance components to create energy efficient buildings.
In the context of construction, the R-value is a measure of how well a two-dimensional barrier, such as a layer of insulation, a window or a complete wall or ceiling, resists the conductive flow of heat. R-value is the temperature difference per unit of heat flux needed to sustain one unit of heat flux between the warmer surface and colder surface of a barrier under steady-state conditions. The measure is therefore equally relevant for lowering energy bills for heating in the winter, for cooling in the summer, and for general comfort.
A radiant barrier is a type of building material that reflects thermal radiation and reduces heat transfer. Because thermal energy is also transferred by conduction and convection, in addition to radiation, radiant barriers are often supplemented with thermal insulation that slows down heat transfer by conduction or convection.
A curtain wall is an exterior covering of a building in which the outer walls are non-structural, instead serving to protect the interior of the building from the elements. Because the curtain wall façade carries no structural load beyond its own dead load weight, it can be made of lightweight materials. The wall transfers lateral wind loads upon it to the main building structure through connections at floors or columns of the building.
A vacuum insulated panel (VIP) is a form of thermal insulation consisting of a gas-tight enclosure surrounding a rigid core, from which the air has been evacuated. It is used in building construction, refrigeration units, and insulated shipping containers to provide better insulation performance than conventional insulation materials.
A hermetic seal is any type of sealing that makes a given object airtight. The term originally applied to airtight glass containers, but as technology advanced it applied to a larger category of materials, including rubber and plastics. Hermetic seals are essential to the correct and safe functionality of many electronic and healthcare products. Used technically, it is stated in conjunction with a specific test method and conditions of use. Colloquially, the exact requirements of such a seal varies with the application.
Low emissivity refers to a surface condition that emits low levels of radiant thermal (heat) energy. All materials absorb, reflect, and emit radiant energy according to Planck's law but here, the primary concern is a special wavelength interval of radiant energy, namely thermal radiation of materials. In common use, especially building applications, the temperature range of approximately -40 to +80 degrees Celsius is the focus, but in aerospace and industrial process engineering, much broader ranges are of practical concern.
Storm windows are windows that are mounted outside or inside of the main glass windows of a house. Storm windows exist in North America, but are uncommon in continental Europe, where double, triple or quadruple glazing is prevalent. Storm windows can be made of glass, rigid plastic panels, or flexible plastic sheets; and may be permanently or temporarily mounted. They function similarly to insulated glazing. The term may also refer to a small openable flap found in the side window on light aircraft.
Architectural glass is glass that is used as a building material. It is most typically used as transparent glazing material in the building envelope, including windows in the external walls. Glass is also used for internal partitions and as an architectural feature. When used in buildings, glass is often of a safety type, which include reinforced, toughened and laminated glasses.
Thermal transmittance is the rate of transfer of heat through matter. The thermal transmittance of a material or an assembly is expressed as a U-value. The thermal insulance of a structure is the reciprocal of its thermal transmittance.
Building insulation is material used in a building to reduce the flow of thermal energy. While the majority of insulation in buildings is for thermal purposes, the term also applies to acoustic insulation, fire insulation, and impact insulation. Often an insulation material will be chosen for its ability to perform several of these functions at once.
Building insulation materials are the building materials that form the thermal envelope of a building or otherwise reduce heat transfer.
Rigid panel insulation, also referred to as continuous insulation, can be made from foam plastics such as polyurethane (PUR), polyisocyanurate (PIR), and polystyrene, or from fibrous materials such as fiberglass, rock and slag wool. Rigid panel continuous insulation is often used to provide a thermal break in the building envelope, thus reducing thermal bridging.
Window insulation reduces heat transfer from one side of a window to the other. The U-value is used to refer to the amount of heat that can pass through a window, called thermal transmittance, with a lower score being better. The U-factor of a window can often be found on the rating label of the window.
Glazing, which derives from the Middle English for 'glass', is a part of a wall or window, made of glass. Glazing also describes the work done by a professional "glazier". Glazing is also less commonly used to describe the insertion of ophthalmic lenses into an eyeglass frame.
A skylight is a light-permitting structure or window, usually made of transparent or translucent glass, that forms all or part of the roof space of a building for daylighting and ventilation purposes.
Quadruple glazing is a type of insulated glazing comprising four glass panes, commonly equipped with low emissivity coating and insulating gases in the cavities between the glass panes. Quadruple glazing is a subset of multipane (multilayer) glazing systems. Multipane glazing with up to six panes is commercially available.
{{cite web}}
: CS1 maint: archived copy as title (link)