Sound transmission class

Last updated

Sound Transmission Class (or STC) is an integer rating of how well a building partition attenuates airborne sound. In the US, it is widely used to rate interior partitions, ceilings, floors, doors, windows and exterior wall configurations. Outside the US, the ISO Sound Reduction Index (SRI) is used. The STC rating very roughly reflects the decibel reduction of noise that a partition can provide. The STC is useful for evaluating annoyance due to speech sounds, but not music or machinery noise as these sources contain more low frequency energy than speech. [1]

Contents

There are many ways to improve the sound transmission class of a partition, though the two most basic principles are adding mass and increasing the overall thickness. In general, the sound transmission class of a double wythe wall (e.g. two 4-inch-thick [100 mm] block walls separated by a 2-inch [51 mm] airspace) is greater than a single wall of equivalent mass (e.g. homogeneous 8-inch [200 mm] block wall). [2]

Definition

The STC or sound transmission class is a single number method of rating how well wall partitions reduce sound transmission. [3] The STC provides a standardized way to compare products such as doors and windows made by competing manufacturers. A higher number indicates more effective sound insulation than a lower number. The STC is a standardized rating provided by ASTM E413 based on laboratory measurements performed in accordance with ASRM E90. ASTM E413 can also be used to determine similar ratings from field measurements performed in accordance with ASTM E336. [3]

Sound Isolation and Sound Insulation are used interchangeably, though the term "Insulation" is preferred outside the US. [4] The term "sound proofing" is typically avoided in architectural acoustics as it is a misnomer and connotes inaudibility.

Subjective correlation

Through research, acousticians have developed tables that pair a given STC rating with a subjective experience. The table below is used to determine the degree of sound isolation provided by typical multi-family construction. Generally, a difference of one or two STC points between similar constructions is subjectively insignificant. [5]

STCs by audio distinguishability
STCWhat can be heard
25Normal speech can be understood
30Loud speech can be understood
35Loud speech audible but not intelligible
40Loud speech audible as a murmur
45Loud speech heard but not audible
50Loud sounds faintly heard
60+Good soundproofing; most sounds do not disturb neighboring residents. [6]

Tables like the one above are highly dependent on the background noise levels in the receiving room: the louder the background noise, the greater the perceived sound isolation. [7]

Rating methodology

Historical

Prior to the STC rating, the sound isolation performance of a partition was measured and reported as the average transmission loss of over the frequency range 128 to 4096  Hz or 256 to 1021 Hz. [8] [9] This method is valuable at comparing homogeneous partitions that follow the mass law, but can be misleading when comparing complex or multi-leaf walls.

In 1961, the ASTM International Standards Organization adopted E90-61T, which served as the basis for the STC method used today. The STC standard curve is based on European studies of multi-family residential construction, and closely resembles the sound isolation performance of a 9-inch-thick (230 mm) brick wall. [10]

Current

Sound Transmission Class Report Sample from NTi Audio showing Transmission Loss in the sixteen standard frequencies Sound-Transmission-Class-Report-Sample.jpg
Sound Transmission Class Report Sample from NTi Audio showing Transmission Loss in the sixteen standard frequencies

The STC number is derived from sound attenuation values tested at sixteen standard frequencies from 125 Hz to 4000 Hz. These Transmission Loss values are then plotted on a sound pressure level graph and the resulting curve is compared to a standard reference contour provided by the ASTM. [11]

Sound isolation metrics, such as the STC, are measured in specially-isolated and designed laboratory test chambers. There are nearly infinite field conditions that will affect sound isolation on site when designing building partitions and enclosures.

Factors affecting sound transmission class

Acoustic medium

Sound travels through both the air and structure, and both paths must be considered when designing sound isolating walls and ceilings. To eliminate air borne sound all air paths between the areas must be eliminated. This is achieved by making seams airtight and closing all sound leaks. To eliminate structure-borne noise one must create isolation systems that reduce mechanical connections between those structures. [12]

Mass

Adding mass to a partition reduces the transmission of sound. This is often achieved by adding additional layers of gypsum. It is preferable to have non symmetrical leaves, for example with different thickness gypsum. [13] The effect of adding multiple layers of gypsum wallboard to a frame also varies depending on the framing type and configuration. [14] [15] Doubling the mass of a partition does not double the STC, as the STC is calculated from a non-linear decibel sound transmission loss measurement. [16] So, whereas installing an additional layer of gypsum wallboard to a light-gauge (25-ga. or lighter) steel stud partition will result in about a 5 STC-point increase, doing the same on single wood or single heavy-gauge steel will result in only 2 to 3 additional STC points. [14] [15] Adding a second additional layer (to the already three-layer system) does not result in as drastic an STC change as the first additional layer. [14] The effect of additional gypsum wallboard layers on double- and staggered-stud partitions is similar to that of light-gauge steel partitions.

Due to increased mass, poured concrete and concrete blocks typically achieve higher STC values (in the mid STC 40s to the mid STC 50s) than equally thick framed walls. [17] However the additional weight, added complexity of construction, and poor thermal insulation tend to limit masonry wall partitions as a viable sound isolation solution in many building construction projects.

In recent years,[ when? ] gypsum board manufacturers have started to offer lightweight drywall board: Normal-weight gypsum has a nominal density of 43 pounds per cubic foot (690 kg/m3), and lightweight drywall has a nominal density of 36 pounds per cubic foot (580 kg/m3). This does not have a large effect on the STC rating, though lightweight gypsum can significantly degrade the low frequency performance of a partition as compared to normal weight gypsum.

Sound absorption

Sound absorption entails turning acoustical energy into some other form of energy, usually heat. [18]

Adding absorptive materials to the interior surfaces of rooms, for example fabric-faced fiberglass panels and thick curtains, will result in a decrease of reverberated sound energy within the room. However, absorptive interior surface treatments of this kind do not significantly improve the sound transmission class. [19] Installing absorptive insulation, for example fiberglass batts and blow-in cellulose, into the wall or ceiling cavities does increase the sound transmission class significantly. [14] The presence of insulation in single 2x4 wood stud framing spaced 16 inches (410 mm) on-center results in only a few STC points. This is because a wall with 2x4 wood stud framing spaced 16 inches develops significant resonances which are not mitigated by the cavity insulation. In contrast, adding standard fiberglass insulation to an otherwise empty cavity in light-gauge (25-gauge or lighter) steel stud partitions can result in a nearly 10 STC-point improvement.

Other studies have shown that fibrous insulation materials, such as mineral wool, can increase the STC by 5 to 8 points. [13]

Stiffness

The effect of stiffness on sound isolation can relate to either the material stiffness of the sound isolating material or the stiffness caused by framing methods.

Framing methods

Structurally decoupling the gypsum wallboard panels from the partition framing can result in a large increase in sound isolation when installed correctly. Examples of structural decoupling in building construction include resilient channels, sound isolation clips and hat channels, and staggered- or double-stud framing. The STC results of decoupling in wall and ceiling assemblies varies significantly depending on the framing type, air cavity volume, and decoupling material type. [14] Great care must be taken in each type of decoupled partition construction, as any fastener that becomes mechanically (rigidly) coupled to the framing can undermine the decoupling and result in drastically lower sound isolation results. [20]

When two leaves are rigidly tied or coupled by a stud, the sound isolation of the system depends on the stiffness of the stud. Light-gauge (25-gauge or lighter) provides better sound isolation than 16-20-gauge steel, and noticeably better performance than wood studs. [21] When heavy gauge steel or wood studs are spaced 16 inches (410 mm) on center, additional resonances form which further lower the sound isolation performance of a partition. For typical gypsum stud walls, this resonance occurs in the 100–160 Hz region and is thought to be a hybrid of the mass-air-mass resonance and a bending mode resonance caused when a plate is closely supported by stiff members. [22]

Single metal stud partitions are more effective than single wood stud partitions, and have been shown to increase the STC rating by up to 10 points. However, there is little difference between metal and wood studs when used in double stud partitions. [13] Double stud partitions have a higher STC than single stud. [13]

In certain assemblies, increasing the stud spacing from 16 to 24 inches (410–610 mm) increases the STC rating by 2 to 3 points. [13]

Damping

Though the terms sound absorption and damping are often interchangeable when discussing room acoustics, acousticians define these as two distinct properties of sound-isolating walls.

Several gypsum manufacturers offer specialty products which use constrained layer damping, which is a form of viscous damping. [23] [24] Damping generally increases the sound isolation of partitions, particularly at mid-and-high frequencies.

Damping is also used to improve the sound isolation performance of glazing assemblies. Laminated glazing, which consists of a Polyvinyl butyral (or PVB) inter-layer, performs better acoustically than a non-laminated glass of equivalent thickness. [25]

Sound leakage

A small gap in the wall can greatly reduce the STC rating. This wall did not receive a full perimeter seal. Gap at the base of a partition.jpg
A small gap in the wall can greatly reduce the STC rating. This wall did not receive a full perimeter seal.

All holes and gaps should be filled and the enclosure hermetically sealed for sound isolation to be effective. The table below illustrates sound proofing test results from a wall partition that has a theoretical maximum loss of 40 dB from one room to the next and a partition area of 10 meters squared. Even small open gaps and holes in the partition have a disproportionate reduction in sound proofing. A 5% opening in the partition, which offers unrestricted sound transmission from one room to the next, caused the transmission loss to reduce from 40 dB to 13 dB. A 0.1% open area will reduce the transmission loss from 40 dB to 30 dB, which is typical of walls where caulking has not been applied effectively [26] Partitions that are inadequately sealed and contain back-to-back electrical boxes, untreated recessed lighting and unsealed pipes offer flanking paths for sound and significant leakage. [27]

Acoustic joint tapes and caulking have been used to improve sound isolation since the early 1930s. [28] Although the applications of tapes was largely limited to defense and industrial applications such as naval vessels and aircraft in the past, recent research has proven the effectiveness of sealing gaps and thereby improving the sound isolation performance of a partition. [29]

Sound diminution by percentage openness of barrier
Transmission loss % of area open
13 dB5% open
17 dB2% open
20 dB1% open
23 dB0.5% open
27 dB0.2% open
30 dB0.1% open
33 dB0.05% open
37 dB0.02% open
39.5 dBPractical maximum loss
40 dBTheoretical maximum loss

Flanking

Building codes typically allow for a 5-point tolerance between the lab-tested and field-measured STC rating; however, studies have shown that even in well-built and sealed installations the difference between the lab and field rating is highly dependent on the type of assembly. [30]

Special variations of STC

By nature, the STC rating is derived from lab testing under ideal conditions. There are other versions of the STC rating to account for real-world conditions.

Composite STC

The net sound isolation performance of a partition containing multiple sound isolating elements such as doors, windows, etc.

Apparent Sound Transmission Class (ASTC)

The sound isolation performance of a partition measured in the field according to ASTM E336, normalized to account for different room finishes and the area of the tested partition (i.e. compare the same wall measured in a bare living room and an acoustically dry recording booth).

Normalized Noise Isolation Class (NNIC)

The sound isolation performance of a partition measured in the field according to ASTM E336, normalized to account for the reverberation time in the room.

Noise Isolation Class (NIC)

The sound isolation performance of a partition measured in the field according to ASTM E336, not normalized to the room conditions of the test.

Field Sound Transmission Class (FSTC)

The sound isolation performance of a specific elements in a partition, as measured in the field and achieved by suppressing the effects of sound flanking paths. This can be useful for measuring walls with doors, when you are interested in removing the influence of the door on the measured field STC. The FSTC testing method was historically prescribed by ASTM E336, however the latest version of this standard does not include FSTC. [31]

Door Sound Transmission Class (DTC)

The sound isolation performance of doors when measured according to ASTM E2964. [32]

Section 1206 of International Building Code 2021 states that separation between dwelling units and public and service areas must achieve STC 50 where tested in accordance with ASTM E90, or NNIC 45 if field tested in accordance with ASTM E336. However, not all jurisdictions use the IBC for their building or municipal code.

Common partition STC

Interior walls with 1 sheet of 12-inch (13 mm) gypsum wallboard (drywall) on either side of 2x4 (1+12 in × 3+12 in or 38 mm × 89 mm) wood studs spaced 16 inches (410 mm) on-center with no fiberglass insulation filling each stud cavity have an STC of about 33. [14] When asked to rate their acoustical performance, people often describe these walls as "paper thin." They offer little in the way of privacy. Double stud partition walls are typically constructed with varying gypsum wallboard panel layers attached to both sides of double 2x4 wood studs spaced 16 inches on-center and separated by a 1-inch (25 mm) airspace. These walls vary in sound isolation performance from the mid STC-40s into the high STC-60s depending on the presence of insulation and the gypsum wallboard type and quantity. [14] Commercial buildings are typically constructed using steel studs of varying widths, gauges, and on-center spacings. Each of these framing characteristics have an effect on the sound isolation of the partition to varying degrees. [15]

STCs by partition type
STCPartition type
27Single pane glass window (typical value) (dual-pane glass window range is 26–32) "STC Ratings".
33Single layer of 12-inch (13 mm) drywall on each side, wood studs, no insulation (typical interior wall)
39Single layer of 12-inch (13 mm) drywall on each side, wood studs, fiberglass insulation [33]
444-inch (100 mm) hollow CMU (concrete masonry unit) [34]
45Double layer of 12-inch (13 mm) drywall on each side, wood studs, batt insulation in wall
46Single layer of 12-inch (13 mm) drywall, glued to 6-inch (150 mm) lightweight concrete block wall, painted both sides
466-inch (150 mm) hollow CMU (concrete masonry unit) [34]
488-inch (200 mm) hollow CMU (concrete masonry unit) [34]
5010-inch (250 mm) hollow CMU (concrete masonry unit) [34]
528-inch (200 mm) hollow CMU (concrete masonry unit) with 2-inch (51 mm) Z-bars and 12-inch (13 mm) drywall on each side [35]
54Single layer of 12-inch (13 mm) drywall, glued to 8-inch (200 mm) dense concrete block wall, painted both sides
548-inch (200 mm) hollow CMU (concrete masonry unit) with 1+12-inch (38 mm) wood furring, 1+12-inch fiberglass insulation and 12-inch (13 mm) drywall on each side [35]
55Double layer of 12-inch (13 mm) drywall on each side, on staggered wood stud wall, batt insulation in wall
59Double layer of 12-inch (13 mm) drywall on each side, on wood stud wall, resilient channels on one side, batt insulation
63Double layer of 12-inch (13 mm) drywall on each side, on double wood/metal stud walls (spaced 1 inch [25 mm] apart), double batt insulation
648-inch (200 mm) hollow CMU (concrete masonry unit) with 3-inch (76 mm) steel studs, fiberglass insulation and 12-inch (13 mm) drywall on each side [35]
728-inch (200 mm) concrete block wall, painted, with 12-inch (13 mm) drywall on independent steel stud walls, each side, insulation in cavities

STC prediction

There are several commercially available software which predict the STC ratings of partitions using a combination of theoretical models and empirically derived lab data. These programs can predict STC ratings within several points of a tested partition and are an approximation at best. [36]

Outdoor-Indoor Transmission Class (OITC)

The Outdoor–Indoor Transmission Class (OITC) is a standard used for indicating the rate of sound transmission from outdoor noise sources into a building. It is based on the ASTM E-1332 Standard Classification for Rating Outdoor-Indoor Sound Attenuation. [37] Unlike the STC, which is based on a noise spectrum targeting speech sounds, OITC uses a source noise spectrum that considers frequencies down to 80 Hz (aircraft/rail/truck traffic) and is weighted more to lower frequencies. The OITC value is typically used to rate, evaluate, and select exterior glazing assemblies.

See also

Related Research Articles

<span class="mw-page-title-main">Wall</span> Vertical structure, usually solid, that defines and sometimes protects an area

A wall is a structure and a surface that defines an area; carries a load; provides security, shelter, or soundproofing; or, is decorative. There are many kinds of walls, including:

<span class="mw-page-title-main">Drywall</span> Panel made of gypsum, used in interior construction

Drywall is a panel made of calcium sulfate dihydrate (gypsum), with or without additives, typically extruded between thick sheets of facer and backer paper, used in the construction of interior walls and ceilings. The plaster is mixed with fiber ; plasticizer, foaming agent; and additives that can reduce mildew, flammability, and water absorption.

<span class="mw-page-title-main">Soundproofing</span> Methods to reduce sound pressure

Soundproofing is any means of impeding sound propagation. There are several methods employed including increasing the distance between the source and receiver, decoupling, using noise barriers to reflect or absorb the energy of the sound waves, using damping structures such as sound baffles for absorption, or using active antinoise sound generators.

<span class="mw-page-title-main">Noise reduction coefficient</span>

The noise reduction coefficient is a single number value ranging from 0.0 to 1.0 that describes the average sound absorption performance of a material. An NRC of 0.0 indicates the object does not attenuate mid-frequency sounds, but rather reflects sound energy. This is more conceptual than physically achievable: even very thick concrete walls will attenuate sound and may have an NRC of 0.05. Conversely, an NRC of 1.0 indicates that the material provides an acoustic surface area that is equivalent to its physical, two-dimensional surface area. This rating is common of thicker, porous sound absorptive materials such as 2-inch-thick (51 mm) fabric-wrapped fiberglass panel. Materials can achieve NRC values greater than 1.00. This is a shortcoming of the test procedure and a limitation of how acousticians define a square unit of absorption, and not a characteristic of the material itself.

<span class="mw-page-title-main">Architectural acoustics</span> Science and engineering of achieving a good sound within a building

Architectural acoustics is the science and engineering of achieving a good sound within a building and is a branch of acoustical engineering. The first application of modern scientific methods to architectural acoustics was carried out by the American physicist Wallace Sabine in the Fogg Museum lecture room. He applied his newfound knowledge to the design of Symphony Hall, Boston.

<span class="mw-page-title-main">Lath and plaster</span> Finish mainly for interior dividing walls and ceilings

Lath and plaster is a building process used to finish mainly interior dividing walls and ceilings. It consists of narrow strips of wood (laths) which are nailed horizontally across the wall studs or ceiling joists and then coated in plaster. The technique derives from an earlier, more primitive process called wattle and daub.

A sound attenuator, or duct silencer, sound trap, or muffler, is a noise control acoustical treatment of Heating Ventilating and Air-Conditioning (HVAC) ductwork designed to reduce transmission of noise through the ductwork, either from equipment into occupied spaces in a building, or between occupied spaces.

<span class="mw-page-title-main">Drywall mechanic</span>

A drywall mechanic is a skilled trade similar to wood carpenters, except they build everything out of light gauge steel studs all year round, regardless of weather conditions. Drywall mechanics erect various exterior and interior stud wall partitions. They also install metal door frames, window frames, a variety of acoustical ceilings, and precast moldings for columns and ceilings. In addition, they also install x-ray shielding, thermal and sound insulation and a variety of drywall panels and metal and vinyl trims.

<span class="mw-page-title-main">Noise control</span> Strategies to reduce noise pollution or its impact

Noise control or noise mitigation is a set of strategies to reduce noise pollution or to reduce the impact of that noise, whether outdoors or indoors.

<span class="mw-page-title-main">Passive fire protection</span> Component or system to passively prevent the spread of fire

Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. Examples of passive systems include floor-ceilings and roofs, fire doors, windows, and wall assemblies, fire-resistant coatings, and other fire and smoke control assemblies. Passive fire protection systems can include active components such as fire dampers.

Acoustiblok, a registered trademark of Acoustiblok Inc., is manufactured in the United States. It is a sound attenuation material that was introduced in 1999. It is implemented in new construction and remodeling projects. It is designed to be applied behind drywall and other finishing materials.

Sound masking is the inclusion of generated sound into an environment to mask unwanted sound. It relies on auditory masking. Sound masking is not a form of active noise control ; however, it can reduce or eliminate the perception of sound. Sound masking is applied to an entire area to improve acoustical satisfaction, thus improving the acoustical privacy of the space. This can help an individual focus and thereby enhance productivity.

The sound reduction index is used to measure the level of sound insulation provided by a structure such as a wall, window, door, or ventilator. It is defined in the series of international standards ISO 16283 and the older ISO 140, or the regional or national variants on these standards. In the United States, the sound transmission class rating is generally used instead. The basic method for both the actual measurements and the mathematical calculations behind both standards is similar, however they diverge to a significant degree in the detail, and in the numerical results produced.

<span class="mw-page-title-main">Building insulation material</span> Insulation material

Building insulation materials are the building materials that form the thermal envelope of a building or otherwise reduce heat transfer.

The ASA Silver Medal is an award presented by the Acoustical Society of America to individuals, without age limitation, for contributions to the advancement of science, engineering, or human welfare through the application of acoustic principles or through research accomplishments in acoustics. The medal is awarded in a number of categories depending on the technical committee responsible for making the nomination.

Acoustic quieting is the process of making machinery quieter by damping vibrations to prevent them from reaching an observer. Machinery vibrates, causing sound waves in air, hydroacoustic waves in water, and mechanical stresses in solid matter. Quieting is achieved by absorbing the vibrational energy or minimizing the source of the vibration. It may also be redirected away from an observer.

<span class="mw-page-title-main">Magnesium oxide wallboard</span>

Magnesium oxide, more commonly called magnesia, is a mineral that when used as part of a cement mixture and cast into thin cement panels under proper curing procedures and practices can be used in residential and commercial building construction. Some versions are suitable for general building uses and for applications that require fire resistance, mold and mildew control, as well as sound control applications. Magnesia board has strength and resistance due to very strong bonds between magnesium and oxygen atoms that form magnesium oxide crystals.

<span class="mw-page-title-main">Gypsum block</span>

Gypsum block is a massive lightweight building material composed of solid gypsum, for building and erecting lightweight, fire-resistant, non-load bearing interior walls, partition walls, cavity walls, skin walls, and pillar casing indoors. Gypsum blocks are composed of gypsum, plaster, water and in some cases additives like vegetable or wood fiber for greater strength. Partition walls, made from gypsum blocks, require no sub-structure for erection and gypsum adhesive is used as bonding agent, not standard mortar. Because of this fundamental difference, gypsum blocks shouldn't be confused with the thinner plasterboard used for paneling stud walls.

The Pioneers of Underwater Acoustics Medal is awarded by the Acoustical Society of America in recognition of "an outstanding contribution to the science of underwater acoustics, as evidenced by publication of research results in professional journals or by other accomplishments in the field". The award was named in honor of H. J. W. Fay, Reginald Fessenden, Harvey Hayes, G. W. Pierce, and Paul Langevin.

Paul Earls Sabine was an American acoustic engineer and a specialist on acoustic architecture. Sound absorbing boards made of porous gypsum was sometimes known by the tradename Sabinite. He was a director at the Riverbank Laboratories until his retirement in 1947.

References

  1. Roller, H. Stanley (November 1985). "Isolating music and mechanical equipment sound sources with gypsum board partition systems". The Journal of the Acoustical Society of America. 78 (S1): S10. Bibcode:1985ASAJ...78...10R. doi: 10.1121/1.2022641 . ISSN   0001-4966.
  2. Egan, M. David. (2007). Architectural acoustics. J. Ross Publishing. ISBN   978-1-932159-78-3. OCLC   636858059.
  3. 1 2 Ballou 2008, p. 72.
  4. Hopkins, Carl. (2016). Sound insulation. Routledge. ISBN   978-1-138-13770-7. OCLC   933449409.
  5. Berendt, Raymond D. (1967). A guide to airborne, impact, and structure borne noise-control in multifamily dwellings. U.S. Dept. of Housing and Urban Development. OCLC   5863574.
  6. Bradley, J.S. (August 2001). Deriving Acceptable Values for Party Wall Sound Insulation from Survey Results. Inter-noise 2001 : The 2001 International Congress and Exhibition on Noise Control Engineering. The Hague, The Netherlands. ISBN   9789080655423. OCLC   48937099.
  7. Cavanaugh, W.J.; Farrell, W.R.; Hirtle, P.W.; Watters, B.G. (April 1962). "Speech Privacy in Buildings". The Journal of the Acoustical Society of America. 34 (4): 475–492. Bibcode:1962ASAJ...34..475C. doi:10.1121/1.1918154. ISSN   0001-4966.
  8. Knudsen, Vern O. (1988). Acoustical designing in architecture . Acoustical Society of America. ISBN   0-88318-267-X. OCLC   758181173.
  9. Chrisler, V. L. (1939). Sound insulation of wall and floor constructions. U.S. G.P.O. OCLC   14104628.
  10. Northwood, T. D. (April 1962). "Sound-Insulation Ratings and the New ASTM Sound-Transmission Class". The Journal of the Acoustical Society of America. 34 (4): 493–501. Bibcode:1962ASAJ...34..493N. doi:10.1121/1.1918155. ISSN   0001-4966.
  11. Ballou 2008, pp. 72–73.
  12. Ballou 2008, p. 89.
  13. 1 2 3 4 5 Ballou, Glen, ed. (2015). Handbook for sound engineers (5th ed.). CRC Press. ISBN   978-1-135-01665-4. OCLC   913880162.
  14. 1 2 3 4 5 6 7 Halliwell, R.E.; Nightingale, T.R.T.; Warnock, A.C.C.; Birta, J.A. (March 1998). "Gypsum Board Walls: Transmission Loss Data". National Research Council Canada. doi:10.4224/20331556. IRC-IR-761.
  15. 1 2 3 Bétit, Aaron (March 2010). "Performance Details of Metal Stud Partitions" (PDF). Sound and Vibration Magazine: 14–16.
  16. "ASTM E413-22 Classification for Rating Sound Insulation". ASTM International. May 2022.
  17. Warnock, A.C.C. (1985). "Field sound transmission loss measurements". Building Research Note. 1985–06. doi:10.4224/40000485.
  18. Ballou 2008, p. 97.
  19. Brown, Steven M.; Niedzielski, Joseph; Spalding, G. Robert (1978). "Effect of sound-absorptive facings on partition airborne-sound transmission loss". The Journal of the Acoustical Society of America. 63 (6): 1851–1856. Bibcode:1978ASAJ...63.1851B. doi:10.1121/1.381924.
  20. LoVerde, J.; Dong, W. (2010). "Quantitative comparisons of resilient channel design and installation in single wood stud walls" (PDF). Proceedings of 20th International Congress on Acoustics, ICA 2010.
  21. Halliwell, R. E. (1998). Gypsum board walls : transmission loss data. Institute for Research in Construction. OCLC   155721225.
  22. Davy, John L.; Fard, Mohammad; Dong, Wayland; Loverde, John (February 2019). "Empirical corrections for predicting the sound insulation of double leaf cavity stud building elements with stiffer studs". The Journal of the Acoustical Society of America. 145 (2): 703–713. Bibcode:2019ASAJ..145..703D. doi:10.1121/1.5089222. ISSN   0001-4966. PMID   30823783. S2CID   73462977.
  23. Shafer, Benjamin M.; Tinianov, Brandon (October 2011). "Use of damped drywall in architectural acoustics". The Journal of the Acoustical Society of America. 130 (4): 2388. Bibcode:2011ASAJ..130R2388S. doi:10.1121/1.3654567. ISSN   0001-4966.
  24. Tinianov, Brian D. (September 2005). "Two case studies: QuietRock QR-530 drywall panels in new and remediated multifamily construction". The Journal of the Acoustical Society of America. 118 (3): 1976. doi:10.1121/1.2097073. ISSN   0001-4966.
  25. Acoustical glazing design guide : laminated glass with Saflex plastic interlayer for superior sound control. Monsanto Company. 1986. OCLC   38400395.
  26. Ballou 2008, pp. 77–78.
  27. "Acoustics in Practice - NRC-CNRC". Archived from the original on 2010-03-15. Retrieved 2012-02-07. Acoustics in Practice
  28. Shafer, Benjamin M. (2013). An overview of constrained-layer damping theory and application. Proceedings of Meetings on Acoustics. Vol. 133. Acoustical Society of America. p. 065023. Bibcode:2013ASAJ..133.3332S. doi: 10.1121/1.4800606 .
  29. Shafer, Benjamin M.; Tinianov, Brandon (2011). "Use of damped drywall in architectural acoustics". The Journal of the Acoustical Society of America. 130 (4): 2388. Bibcode:2011ASAJ..130R2388S. doi:10.1121/1.3654567.
  30. LoVerde, John; Dong, Wayland (2010). "Predictability of field airborne noise isolation from laboratory testing". The Journal of the Acoustical Society of America. 127 (3): 1741. Bibcode:2010ASAJ..127.1741L. doi:10.1121/1.3383509. ISSN   0001-4966.
  31. ASTM E336-20 (2020). "Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings". Conshohocken, PA: ASTM International.{{cite web}}: CS1 maint: numeric names: authors list (link)
  32. Standard Test Method for Measurement of the Normalized Insertion Loss of Doors, ASTM International, doi:10.1520/e2964-14
  33. The Complete Photo Guide to Home Improvement . Creative Publishing international. July 2001. p.  194. ISBN   9780865735804 . Retrieved 2011-10-01. The Complete Photo Guide to Home Improvement.
  34. 1 2 3 4 "STC Ratings for Masonry Walls". Acoustics.com. Retrieved 2011-10-01.
  35. 1 2 3 "New Data Shows Masonry Wall and Precast Hollow Core Floor Systems Reaching High STC Ratings" (PDF). Masonry Advisory Council. Retrieved 2011-10-01.
  36. Horan, Daniel (2014). "Computer Modeling of STC- Options and Accuracy" (PDF). Sound & Vibration (December): 8–11.
  37. ASTM E1332-16 (2016). "Standard Classification for Rating Outdoor-Indoor Sound Attenuation". Conshohocken, PA: ASTM International.{{cite web}}: CS1 maint: numeric names: authors list (link)

Bibliography