Large Plasma Device

Last updated

The Large Plasma Device during an experiment. Lapd exterior.jpg
The Large Plasma Device during an experiment.

The Large Plasma Device (often stylized as LArge Plasma Device or LAPD) is an experimental physics device located at UCLA. It is designed as a general purpose laboratory for experimental plasma physics research. The device began operation in 1991 [1] and was upgraded in 2001 [2] to its current version. The modern LAPD is operated as the primary device for a national collaborative research facility, the Basic Plasma Science Facility (or BaPSF), which is supported by the US Department of Energy, Fusion Energy Sciences and the National Science Foundation. [3] Half of the operation time of the device is available to scientists at other institutions and facilities who can compete for time through a yearly solicitation. [4] [5]

Contents

History

The first version of the LAPD was a 10 meter long device constructed by a team led by Walter Gekelman in 1991. The construction took 3.5 years to complete and was funded by the Office of Naval Research (ONR). A major upgrade to a 20 meter version was funded by ONR and an NSF Major Research Instrumentation award in 1999. [6] Following the completion of that major upgrade, the award of a $4.8 million grant by the US Department of Energy and the National Science Foundation in 2001 enabled the creation of the Basic Plasma Science Facility and the operation of the LAPD as part of this national user facility. Gekelman was director of the facility until 2016, when Troy Carter became BaPSF director.

Machine overview

A view of the laboratory and the interior of the Large Plasma Device down the south end of the machine during its upgrade in January 2020. Large Plasma Device Interior 2020.jpg
A view of the laboratory and the interior of the Large Plasma Device down the south end of the machine during its upgrade in January 2020.

The LAPD is a linear pulsed-discharge device operated at a high (1 Hz) repetition rate, producing a strongly magnetized background plasma which is physically large enough to support Alfvén waves. Plasma is produced from a barium oxide (BaO) cathode-anode discharge at one end of a 20-meter long, 1 meter diameter cylindrical vacuum vessel (diagram). The resulting plasma column is roughly 16.5 meters long and 60 cm in diameter. The background magnetic field, produced by a series of large electromagnets surrounding the chamber, can be varied from 400 gauss to 2.5 kilogauss (40 to 250 mT).

Plasma parameters

Because the LAPD is a general-purpose research device, the plasma parameters are carefully selected to make diagnostics simple without the problems associated with hotter (e.g. fusion-level) plasmas, while still providing a useful environment in which to do research. The typical operational parameters are:

In principle, a plasma may be generated from any kind of gas, but inert gases are typically used to prevent the plasma from destroying the coating on the barium oxide cathode. Examples of gases used are helium, argon, nitrogen and neon. Hydrogen is sometimes used for short periods of time. Multiple gases can also be mixed in varying ratios within the chamber to produce multi-species plasmas.

At these parameters, the ion Larmor radius is a few millimeters, and the Debye length is tens of micrometres. Importantly, it also implies that the Alfvén wavelength is a few meters, and in fact shear Alfvén waves are routinely observed in the LAPD. This is the main reason for the 20-meter length of the device.

Plasma sources

An interior view from an end port on the north end of the device showing a heated barium oxide cathode. The machine is under vacuum but the plasma discharge is turned off. Lapd interior.jpg
An interior view from an end port on the north end of the device showing a heated barium oxide cathode. The machine is under vacuum but the plasma discharge is turned off.

The main source of plasma within the LAPD is produced via discharge from the barium oxide (BaO) coated cathode, which emits electrons via thermionic emission. The cathode is located near the end of the LAPD and is made from a thin nickel sheet, uniformly heated to roughly 900 °C. The circuit is closed by a molybdenum mesh anode a short distance away. Typical discharge currents are in the range of 3-8 kiloamperes at 60-90 volts, supplied by a custom-designed transistor switch backed by a 4-farad capacitor bank.

A secondary cathode source made of lanthanum hexaboride (LaB6) was developed in 2010 [7] to provide a hotter and denser plasma when required. It consists of four square tiles joined to form a 20 20 cm2 area and is located at the other end of the LAPD. The circuit is also closed by a molybdenum mesh anode, which may be placed further down the machine, and is slightly smaller in size to the one used to close the BaO cathode source. The LaB6 cathode is typically heated to temperatures above 1750 °C by a graphite heater, and produces discharge currents of 2.2 kiloamperes at 150 volts.

The plasma in the LAPD is usually pulsed at 1 Hz, with the background BaO source on for 10-20 milliseconds at a time. If the LaB6 source is being utilized, it typically discharges together BaO cathode, but for a shorter period of time (about 5–8 ms) nearing the end of each discharge cycle. The use of an oxide-cathode plasma source, along with a well-designed transistor switch for the discharge, allows for a plasma environment which is extremely reproducible shot-to-shot.

One interesting aspect of the BaO plasma source is its ability to act as an "Alfvén Maser", a source of large-amplitude, coherent shear Alfvén waves. [8] The resonant cavity is formed by the highly reflective nickel cathode and the semitransparent grid anode. Since the source is located at the end of the solenoid which generates the main LAPD background field, there is a gradient in the magnetic field within the cavity. As shear waves do not propagate above the ion cyclotron frequency, the practical effect of this is to act as a filter on the modes which may be excited. Maser activity occurs spontaneously at certain combinations of magnetic field strength and discharge current, and in practice may be activated (or avoided) by the machine user.

Diagnostic access and probes

Probes

The main diagnostic is the movable probe. The relatively low electron temperature makes probe construction straightforward and does not require the use of exotic materials. Most probes are constructed in-house within the facility and include magnetic field probes, [9] Langmuir probes, Mach probes (to measure flow), electric dipole probes and many others. Standard probe design also allows external users to bring their own diagnostics with them, if they desire. Each probe is inserted through its own vacuum interlock, which allows probes to be added and removed while the device is in operation.

A 1 Hz rep-rate, coupled with the high reproducibility of the background plasma, allows the rapid collection of enormous datasets. An experiment on LAPD is typically designed to be repeated once per second, for as many hours or days as is necessary to assemble a complete set of observations. This makes it possible to diagnose experiments using a small number of movable probes, in contrast to the large probe arrays used in many other devices.

The entire length of the device is fitted with "ball joints," vacuum-tight angular couplings (invented by a LAPD staff member) which allow probes to be inserted and rotated, both vertically and horizontally. In practice, these are used in conjunction with computer-controlled motorized probe drives to sample "planes" (vertical cross-sections) of the background plasma with whatever probe is desired. Since the only limitation on the amount of data to be taken (number of points in the plane) is the amount of time spent recording shots at 1 Hz, it is possible to assemble large volumetric datasets consisting of many planes at different axial locations.

Visualizations composed from such volumetric measurements can be seen at the LAPD gallery.

Including the ball joints, there are a total of 450 access ports on the machine, some of which are fitted with windows for optical or microwave observation.

Other diagnostics

A variety of other diagnostics are also available at the LAPD to complement probe measurements. These include photodiodes, microwave interferometers, a high speed camera (3 ns/frame) and laser-induced fluorescence.

See also

Related Research Articles

<span class="mw-page-title-main">Plasma stability</span> Degree to which disturbing a plasma system at equilibrium will destabilize it

In plasma physics, plasma stability concerns the stability properties of a plasma in equilibrium and its behavior under small perturbations. The stability of the system determines if the perturbations will grow, oscillate, or be damped out. It is an important consideration in topics such as nuclear fusion and astrophysical plasma.

<span class="mw-page-title-main">Ion source</span> Device that creates charged atoms and molecules (ions)

An ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines.

<span class="mw-page-title-main">Inertial electrostatic confinement</span> Fusion power research concept

Inertial electrostatic confinement, or IEC, is a class of fusion power devices that use electric fields to confine the plasma rather than the more common approach using magnetic fields found in magnetic confinement fusion (MCF) designs. Most IEC devices directly accelerate their fuel to fusion conditions, thereby avoiding energy losses seen during the longer heating stages of MCF devices. In theory, this makes them more suitable for using alternative aneutronic fusion fuels, which offer a number of major practical benefits and makes IEC devices one of the more widely studied approaches to fusion.

Plasma diagnostics are a pool of methods, instruments, and experimental techniques used to measure properties of a plasma, such as plasma components' density, distribution function over energy (temperature), their spatial profiles and dynamics, which enable to derive plasma parameters.

<span class="mw-page-title-main">Thyratron</span> Gas-filled tube, electrical switch, rectifier

A thyratron is a type of gas-filled tube used as a high-power electrical switch and controlled rectifier. Thyratrons can handle much greater currents than similar hard-vacuum tubes. Electron multiplication occurs when the gas becomes ionized, producing a phenomenon known as Townsend discharge. Gases used include mercury vapor, xenon, neon, and hydrogen. Unlike a vacuum tube (valve), a thyratron cannot be used to amplify signals linearly.

<span class="mw-page-title-main">Magnetic reconnection</span> Process in plasma physics

Magnetic reconnection is a physical process occurring in electrically conducting plasmas, in which the magnetic topology is rearranged and magnetic energy is converted to kinetic energy, thermal energy, and particle acceleration. Magnetic reconnection involves plasma flows at a substantial fraction of the Alfvén wave speed, which is the fundamental speed for mechanical information flow in a magnetized plasma.

A dense plasma focus (DPF) is a type of plasma generating system originally developed as a fusion power device starting in the early 1960s. The system demonstrated scaling laws that suggested it would not be useful in the commercial power role, and since the 1980s it has been used primarily as a fusion teaching system, and as a source of neutrons and X-rays.

<span class="mw-page-title-main">Duoplasmatron</span>

The Duoplasmatron is an ion source in which a cathode filament emits electrons into a vacuum chamber. A gas such as argon is introduced in very small quantities into the chamber, where it becomes charged or ionized through interactions with the free electrons from the cathode, forming a plasma. The plasma is then accelerated through a series of at least two highly charged grids, and becomes an ion beam, moving at a fairly high speed from the aperture of the device.

The Enormous Toroidal Plasma Device (ETPD) is an experimental physics device housed at the Basic Plasma Science Facility at University of California, Los Angeles (UCLA). It previously operated as the Electric Tokamak (ET) between 1999 and 2006 and was noted for being the world's largest tokamak before being decommissioned due to the lack of support and funding. The machine was renamed to ETPD in 2009. At present, the machine is undergoing upgrades to be re-purposed into a general laboratory for experimental plasma physics research.

A double layer is a structure in a plasma consisting of two parallel layers of opposite electrical charge. The sheets of charge, which are not necessarily planar, produce localised excursions of electric potential, resulting in a relatively strong electric field between the layers and weaker but more extensive compensating fields outside, which restore the global potential. Ions and electrons within the double layer are accelerated, decelerated, or deflected by the electric field, depending on their direction of motion.

<span class="mw-page-title-main">Liu Chen (physicist)</span> American physicist

Liu Chen is an American theoretical physicist who has made original contributions to many aspects of plasma physics. He is known for the discoveries of kinetic Alfven waves, toroidal Alfven eigenmodes, and energetic particle modes; the theories of geomagnetic pulsations, Alfven wave heating, and fishbone oscillations, and the first formulation of nonlinear gyrokinetic equations. Chen retired from University of California, Irvine (UCI) in 2012, assuming the title professor emeritus of physics and astronomy.

<span class="mw-page-title-main">Plasma (physics)</span> State of matter

Plasma is one of four fundamental states of matter, characterized by the presence of a significant portion of charged particles in any combination of ions or electrons. It is the most abundant form of ordinary matter in the universe, mostly in stars, but also dominating the rarefied intracluster medium and intergalactic medium. Plasma can be artificially generated, for example, by heating a neutral gas or subjecting it to a strong electromagnetic field.

The GLAss Spherical Tokamak is a name given to a set of small spherical tokamaks located in Islamabad, Pakistan. They were developed by the Pakistan Atomic Energy Commission (PAEC) as part of the National Tokamak Fusion Program (NTFP) in 2008 and are primarily used for teaching and training purposes.

<span class="mw-page-title-main">Ball-pen probe</span>

A ball-pen probe is a modified Langmuir probe used to measure the plasma potential in magnetized plasmas. The ball-pen probe balances the electron and ion saturation currents, so that its floating potential is equal to the plasma potential. Because electrons have a much smaller gyroradius than ions, a moving ceramic shield can be used to screen off an adjustable part of the electron current from the probe collector.

The Star Thrust Experiment (STX) was a plasma physics experiment at the University of Washington's Redmond Plasma Physics Laboratory which ran from 1999 to 2001. The experiment studied magnetic plasma confinement to support controlled nuclear fusion experiments. Specifically, STX pioneered the possibility of forming a Field-reversed configuration (FRC) by using a Rotating Magnetic Field (RMF).

<span class="mw-page-title-main">Compact Toroidal Hybrid</span>

The Compact Toroidal Hybrid (CTH) is an experimental device at Auburn University that uses magnetic fields to confine high-temperature plasmas. CTH is a torsatron type of stellarator with an external, continuously wound helical coil that generates the bulk of the magnetic field for containing a plasma.

Walter N. Gekelman is an experimental plasma physicist and a professor emeritus at the University of California, Los Angeles (UCLA). He is known for the development and construction of the Large Plasma Device (LAPD), an over 20-meter long cylindrical plasma device to study fundamental plasma processes, such as Alfvén waves and magnetic flux ropes, under laboratory conditions. He is an elected fellow of the American Physical Society.

Dmitri Dmitriyevich Ryutov is a Russian theoretical plasma physicist.

Noah Hershkowitz was an American experimental plasma physicist. He was known for his pioneering research on the understanding of plasma sheaths, solitons and double layers in plasmas, as well as the development of the emissive probe which measures the plasma potential.

Reiner Ludwig Stenzel was an American plasma physicist and professor emeritus at the University of California, Los Angeles (UCLA). He was known for his experimental work in basic plasma physics, such as on whistler waves and magnetic reconnection, and had contributed to the development of various plasma probes and antennas, which included the microwave resonator (hairpin) probe. He was a fellow of the American Physical Society.

References

  1. Gekelman, W.; Pfister, H.; Lucky, Z.; Bamber, J.; Leneman, D.; Maggs, J. (1991). "Design, construction, and properties of the large plasma research device−The LAPD at UCLA". Review of Scientific Instruments. 62 (12): 2875–2883. Bibcode:1991RScI...62.2875G. doi:10.1063/1.1142175. ISSN   0034-6748.
  2. Gekelman, W.; Pribyl, P.; Lucky, Z.; Drandell, M.; Leneman, D.; Maggs, J.; Vincena, S.; Van Compernolle, B.; Tripathi, S. K. P. (2016). "The upgraded Large Plasma Device, a machine for studying frontier basic plasma physics". Review of Scientific Instruments. 87 (2): 025105. Bibcode:2016RScI...87b5105G. doi:10.1063/1.4941079. ISSN   0034-6748. PMID   26931889.
  3. "US NSF - MPS - PHY - Facilities and Centers". www.nsf.gov. Retrieved July 29, 2020.
  4. Samuel Reich, Eugenie (2012). "Lab astrophysics aims for the stars". Nature. 491 (7425): 509. Bibcode:2012Natur.491..509R. doi: 10.1038/491509a . ISSN   0028-0836. PMID   23172193.
  5. Perez, Jean C.; Horton, W.; Bengtson, Roger D.; Carter, Troy (2006). "Study of strong cross-field sheared flow with the vorticity probe in the Large Plasma Device". Physics of Plasmas. 13 (5): 055701. Bibcode:2006PhPl...13e5701P. doi:10.1063/1.2179423. ISSN   1070-664X.
  6. "NSF Award Search: Award#9724366 - To Upgrade a Large Plasma Device". www.nsf.gov. Retrieved July 29, 2020.
  7. Cooper, C. M.; Gekelman, W.; Pribyl, P.; Lucky, Z. (2010). "A new large area lanthanum hexaboride plasma source". Review of Scientific Instruments. 81 (8): 083503. Bibcode:2010RScI...81h3503C. doi:10.1063/1.3471917. ISSN   0034-6748. PMID   20815604.
  8. Maggs, J. E.; Morales, G. J.; Carter, T. A. (2004). "An Alfvén wave maser in the laboratory". Physics of Plasmas. 12 (1): 013103. Bibcode:2005PhPl...12a3103M. doi:10.1063/1.1823413. ISSN   1070-664X. PMID   12906425.
  9. Everson, E. T.; Pribyl, P.; Constantin, C. G.; Zylstra, A.; Schaeffer, D.; Kugland, N. L.; Niemann, C. (2009). "Design, construction, and calibration of a three-axis, high-frequency magnetic probe (B-dot probe) as a diagnostic for exploding plasmas". Review of Scientific Instruments. 80 (11): 113505. Bibcode:2009RScI...80k3505E. doi:10.1063/1.3246785. ISSN   0034-6748. PMID   19947729.