Live-line working

Last updated
A lineman wearing equipment for hot glove work Lineman changing transformer.jpg
A lineman wearing equipment for hot glove work

In electrical engineering, live-line working, also known as hotline maintenance, is the maintenance of electrical equipment, often operating at high voltage, while the equipment is energised. Although this is more hazardous for personnel than working on electrical equipment with the power off, live-line maintenance techniques are used in the electric power distribution industry to avoid the disruption and high economic costs of having to turn off power to customers to perform essential periodic maintenance on transmission lines and other equipment.

Contents

The first techniques for live-line working were developed in the early years of the 20th century, and both equipment and work methods were later refined to deal with increasingly higher voltages. In the 1960s, methods were developed in the laboratory to enable field workers to come into direct contact with high voltage lines. Such methods can be applied to enable safe work at the highest transmission voltages. [1]

Background

In general, it is impossible to determine visually whether electrical equipment is energized; in any event, it is often necessary to maintain or repair circuits while they are in operation. In addition, at high voltages, it is unnecessary to come into direct contact with charged equipment to be shocked because an arc can jump from the equipment to a tool or part of the body. Materials such as rubber, while excellent insulators, are also subject to electrical failure at high voltages.

Methods

Working under tension from an electrically insulating platform in a medium voltage network US Navy 110315-N-0278E-002 High-voltage electricians from Naval Facilities Engineering Command (NAVFAC) Hawaii reconfigure electrical circuitry and.jpg
Working under tension from an electrically insulating platform in a medium voltage network

In general, there are three methods of live-line working which help workers avoid the considerable hazards of live line working. [2] In various ways, they all serve to prevent current flowing from the live equipment through the worker.

Hot stick or Live Line Tool
Hot sticks are used in live line work by having the worker remain at a specified distance from the live parts and carry out the work by means of an insulating stick. Tools can be attached to the stick, allowing work to be performed with the worker safely away from the live conductors.
Insulating Gloves or Rubber Gloves
A live line worker is electrically protected by insulating gloves and other insulating equipment, and carries out the work in direct mechanical contact with live parts.
Barehand or Potential
The barehanded approach has a live line worker performing the work in direct electric contact with live parts. Before contact, the worker's body is raised to the same electric potential as the live parts, and then held there by electric connection, while maintaining suitable isolation from the surroundings which are at different potentials, like the ground, other people or trees. Because the worker and the work are at the same potential, no current flows through the worker.
Unearthed or De-energised
Some organizations additionally consider working on unearthed de-energised equipment to be another form of live-line working. This is because the line might become inadvertently charged (e.g. through a back-charged transformer, possibly as a result of an improperly connected, inadequately isolated emergency generator at a customer facility), or inductively coupled from an adjacent in-service line. To prevent this, the line is first grounded via a clamp known as a bond or drain earth. Once this is in place, further work is not considered to be live-line working.

Hot stick

Hot-stick working appeared in the second decade of the 20th century, when insulating poles made from baked wood were used for tasks such as replacing fuses, replacing post insulators, and transferring lines onto temporary supports. [2] The sticks enabled the linemen to carry out the work without infringing on the minimum clearance distances from live equipment. As experience with the techniques developed, then the operating voltages at which the work was performed increased. With the advent of fibreglass poles in the late 1950s, which neither split nor soaked up rainwater, utilities were prepared to carry out hot-stick working to their highest operating voltages, perhaps 765 kV. [2]

Tools, such as hooks or socket wrenches can be mounted at the end of the pole. More sophisticated poles can accept pneumatically or hydraulically driven power tools which allow, for example, bolts to be unscrewed remotely. A rotary wire brush allows a terminal to be scoured clean before a connection is made. However, a worker's dexterity is naturally reduced when operating tools at the end of a pole that is several metres long. [3]

Insulating glove or rubber glove working

Usually applied for work above 1 kV AC 1.5 kV DC The primary classes are: [ citation needed ]

Gloves protect the worker from exposure to the live part being worked upon sometimes referred to as the 1st point of contact; the point where current would enter the body should an inadvertent contact be made. Covers of insulating material such as blankets and linehose are employed in rubber glove working to protect the worker from exposure to a part at a different potential sometimes referred to as the 2nd point of contact; the point where current would leave the body should an inadvertent contact be made.

Bare hand

Bare-hand, or potential working involves placing the worker in direct electrical contact with an energized overhead line. The worker might work alongside the lines, from a platform that is suspended from them, or may sit or stand directly on the line itself. [3] In all cases, the worker's body is maintained at the same voltage as the line. It is imperative that the worker maintain appropriate and adequate limits of approach to any part at a different potential. Such techniques were first used in 1960. [2]

There are a number of ways in which the worker can access the live parts:

As the worker approaches the line, an arc will form between the line and the worker as they are being charged. This arc can be debilitating, and the worker must immediately bond themself electrically to the line to prevent further arcing. [3] A worker may use a conducting wand during the approach to first make the connection. Once on the line, the worker is safe from shock as both the lineworker and the wire are at the same electric potential, and hence no current passes through their body. This is the same principle as that which allows birds to safely sit on power lines. [3]

When the work is completed, the process is reversed to remove the worker safely from the wire. Barehand working provides the lineworker with greater dexterity than the hot stick method, and may be the preferred option if conditions permit it. [4] With this technique, insulator strings, conductor spacers and vibration dampers can be replaced, or lines spliced, without any loss of supply. [4]

The strong electric field surrounding charged equipment is enough to drive a current of approximately 15 μA for each kV·m−1 through a human body. [5] To prevent this, hot-hand workers are usually required to wear a Faraday suit. This is a set of overalls made from or woven throughout with conducting fibers. The suit is in effect a wearable Faraday cage, which equalizes the potential over the body, and ensures there is no through-tissue current. [6] [7] Conducting gloves, even conducting socks, are also necessary, [8] leaving only the face uncovered. [3]

There is little practical upper voltage limit for hot-hand working, and it has been successfully performed at some of the highest transmission operating voltages in the world, such as the Russian 1150 kV system. [9]

Helicopter

A lineworker wearing a Faraday suit can work on live, high-power lines by being transported to the lines in a helicopter. The worker can perform maintenance sitting on an outrigger platform attached to the helicopter while the aircraft hovers next to the line. When approaching the line a long wand is touched to the line to equalize the potential of the aircraft to that of the line, then a breakaway bonding wire connected to the helicopter's frame is attached to the line during work. Alternatively the worker can transfer to the wires from the helicopter and crawl down the wires, then be picked up by the helicopter after the work is completed. [10]

Eye protection

An electric arc is extremely bright, including in the ultraviolet, and can cause arc eye, a painful and potentially blinding condition. Workers may be provided with appropriately tinted goggles that protect their vision in the event of a flash, and provide defence against debris ejected by an arc.

See also

Related Research Articles

<span class="mw-page-title-main">Insulator (electricity)</span> Material that does not conduct an electric current

An electrical insulator is a material in which electric current does not flow freely. The atoms of the insulator have tightly bound electrons which cannot readily move. Other materials—semiconductors and conductors—conduct electric current more easily. The property that distinguishes an insulator is its resistivity; insulators have higher resistivity than semiconductors or conductors. The most common examples are non-metals.

<span class="mw-page-title-main">Overhead line</span> Cable that provides power to electric railways, trams, and trolleybuses

An overhead line or overhead wire is an electrical cable that is used to transmit electrical energy to electric locomotives, trolleybuses or trams. The generic term used by the International Union of Railways for the technology is overhead line. It is known variously as overhead catenary, overhead contact line (OCL), overhead contact system (OCS), overhead equipment (OHE), overhead line equipment, overhead lines (OHL), overhead wiring (OHW), traction wire, and trolley wire.

<span class="mw-page-title-main">Circuit breaker</span> Automatic circuit protection device

A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by overcurrent. Its basic function is to interrupt current flow to protect equipment and to prevent the risk of fire. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset to resume normal operation.

<span class="mw-page-title-main">Electrical substation</span> Part of an electrical transmission, and distribution system

A substation is a part of an electrical generation, transmission, and distribution system. Substations transform voltage from high to low, or the reverse, or perform any of several other important functions. Between the generating station and consumer, electric power may flow through several substations at different voltage levels. A substation may include transformers to change voltage levels between high transmission voltages and lower distribution voltages, or at the interconnection of two different transmission voltages. They are a common component of the infrastructure. There are 55,000 substations in the United States.

<span class="mw-page-title-main">Single-wire earth return</span> Supply energy using single wire with earth as return

Single-wire earth return (SWER) or single-wire ground return is a single-wire transmission line which supplies single-phase electric power from an electrical grid to remote areas at lowest cost. Its distinguishing feature is that the earth is used as the return path for the current, to avoid the need for a second wire to act as a return path.

<span class="mw-page-title-main">Electrical breakdown</span> Conduction of electricity through an insulator under sufficiently high voltage

In electronics, electrical breakdown or dielectric breakdown is a process that occurs when an electrically insulating material, subjected to a high enough voltage, suddenly becomes a conductor and current flows through it. All insulating materials undergo breakdown when the electric field caused by an applied voltage exceeds the material's dielectric strength. The voltage at which a given insulating object becomes conductive is called its breakdown voltage and, in addition to its dielectric strength, depends on its size and shape, and the location on the object at which the voltage is applied. Under sufficient electrical potential, electrical breakdown can occur within solids, liquids, or gases. However, the specific breakdown mechanisms are different for each kind of dielectric medium.

<span class="mw-page-title-main">High voltage</span> Electrical potential which is large enough to cause damage or injury

High voltage electricity refers to electrical potential large enough to cause injury or damage. In certain industries, high voltage refers to voltage above a certain threshold. Equipment and conductors that carry high voltage warrant special safety requirements and procedures.

<span class="mw-page-title-main">Distribution transformer</span> Final stage in power distribution to users

A distribution transformer or service transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. The invention of a practical efficient transformer made AC power distribution feasible; a system using distribution transformers was demonstrated as early as 1882.

<span class="mw-page-title-main">Utility pole</span> Post used by public utilities to support overhead wires and related equipment

A utility pole is a column or post usually made out of wood used to support overhead power lines and various other public utilities, such as electrical cable, fiber optic cable, and related equipment such as transformers and street lights. It can be referred to as a transmission pole, telephone pole, telecommunication pole, power pole, hydro pole, telegraph pole, or telegraph post, depending on its application. A Stobie pole is a multi-purpose pole made of two steel joists held apart by a slab of concrete in the middle, generally found in South Australia.

<span class="mw-page-title-main">Overhead power line</span> Above-ground structure for bulk transfer and distribution of electricity

An overhead power line is a structure used in electric power transmission and distribution to transmit electrical energy along large distances. It consists of one or more conductors suspended by towers or poles. Since most of the insulation is provided by air, overhead power lines are generally the lowest-cost method of power transmission for large quantities of electric energy.

<span class="mw-page-title-main">Lineworker</span> Skilled worker

A lineworker constructs and maintains the electric transmission and distribution facilities that deliver electrical energy to industrial, commercial, and residential establishments. A lineworker installs, services, and emergency repairs electrical lines in the case of lightning, wind, ice storm, or ground disruptions. Whereas lineworkers generally work at outdoor installations, those who install and maintain electrical wiring inside buildings are electricians.

<span class="mw-page-title-main">Arcing horns</span>

Arcing horns are projecting conductors used to protect insulators or switch hardware on high voltage electric power transmission systems from damage during flashover. Overvoltages on transmission lines, due to atmospheric electricity, lightning strikes, or electrical faults, can cause arcs across insulators (flashovers) that can damage them. Alternately, atmospheric conditions or transients that occur during switching can cause an arc to form in the breaking path of a switch during its operation. Arcing horns provide a path for flashover to occur that bypasses the surface of the protected device. Horns are normally paired on either side of an insulator, one connected to the high voltage part and the other to ground, or at the breaking point of a switch contact. They are frequently to be seen on insulator strings on overhead lines, or protecting transformer bushings.

<span class="mw-page-title-main">Arc flash</span> Heat and light produced during an electrical arc fault

An arc flash is the light and heat produced as part of an arc fault, a type of electrical explosion or discharge that results from a connection through air to ground or another voltage phase in an electrical system.

In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire or a blown fuse or circuit breaker. In three-phase systems, a fault may involve one or more phases and ground, or may occur only between phases. In a "ground fault" or "earth fault", current flows into the earth. The prospective short-circuit current of a predictable fault can be calculated for most situations. In power systems, protective devices can detect fault conditions and operate circuit breakers and other devices to limit the loss of service due to a failure.

<span class="mw-page-title-main">Earth potential rise</span> Rise of voltage of local earth when a large current flows through an earth grid impedance

In electrical engineering, earth potential rise (EPR), also called ground potential rise (GPR), occurs when a large current flows to earth through an earth grid impedance. The potential relative to a distant point on the Earth is highest at the point where current enters the ground, and declines with distance from the source. Ground potential rise is a concern in the design of electrical substations because the high potential may be a hazard to people or equipment.

<span class="mw-page-title-main">Fuse cutout</span>

In electrical distribution, a fuse cutout or cut-out fuse is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to melt and the switch mechanism to visibly open, disconnecting the transformer from the line. The device can also be opened manually by utility linemen standing on the ground and using a long insulating stick called a "hot stick".

<span class="mw-page-title-main">Hot stick</span> Electricians tool

In the electric power distribution industry, a hot stick is an insulated pole, usually made of fiberglass, used by electric utility workers when engaged on live-line working on energized high-voltage electric power lines, to protect them from electric shock. Depending on the tool attached to the end of the hot stick, it is possible to test for voltage, tighten nuts and bolts, apply tie wires, open and close switches, replace fuses, lay insulating sleeves on wires, and perform various other tasks while not exposing the crew to a large risk of electric shock.

<span class="mw-page-title-main">Aerial bundled cable</span>

Aerial bundled cables are overhead power lines using several insulated phase conductors bundled tightly together, usually with a bare neutral conductor. This contrasts with the traditional practice of using uninsulated conductors separated by air gaps. This variation of bundled conductors utilizes the same principles as overhead power lines, except that they are closer together to the point of touching but each conductor is surrounded by an insulating layer.

<span class="mw-page-title-main">Corona ring</span>

A corona ring, more correctly referred to as an anti-corona ring, is a toroid of conductive material, usually metal, which is attached to a terminal or other irregular hardware piece of high voltage equipment. The purpose of the corona ring is to distribute the electric field gradient and lower its maximum values below the corona threshold, preventing corona discharge. Corona rings are used on very high voltage power transmission insulators and switchgear, and on scientific research apparatus that generates high voltages. A very similar related device, the grading ring, is used around insulators.

References

  1. Gorur, Ravi (2017-08-26). "Live Line Working and Insulators". INMR : Independent T&D Information Resources. Retrieved 2019-03-10.
  2. 1 2 3 4 "Live Work Guide for Substations" (PDF). EPRI. October 2004. Retrieved 8 December 2008.[ dead link ]
  3. 1 2 3 4 5 Stix, Gary (September 1988). "Working hot: life at 765 kV" (PDF). IEEE Spectrum. 25 (9): 54–56. doi:10.1109/6.7169. ISSN   0018-9235.
  4. 1 2 Miller, R.H.; Malinowski, J.H. (1970). Power System Operation. McGraw-Hill Professional. pp. 178–180. ISBN   978-0-07-041977-3.
  5. Krawulski, Andrzej; Niejadlik, Tomasz (7–9 June 2006). "Live wire work on 400 kV and 220 kV OHL" (PDF). Proceedings of the 8th International Conference on Live Maintenance. Prague: ICOLIM 2006.[ permanent dead link ]
  6. Bosonetto, Doriano; Iulita, Mario (7–9 June 2006). "The development of conductive suits: the Italian experience" (PDF). Proceedings of the 8th International Conference on Live Maintenance. Prague: ICOLIM 2006.[ permanent dead link ]
  7. Davies, John (1988). Performance of Protective Clothing. ASTM International. pp. 813–832. ISBN   978-0-8031-1167-7.
  8. Electrical Times. Vol. 156. July 1969. p. 58.
  9. Krylov, S.V.; Timashova, L.V. "Experience of live-line maintenance on 500-1200 kV lines in Russia". Transmission and Distribution Construction and Live Line Maintenance: 359–368.
  10. Head, Elan (April 2015). "High-value cargo". Vertical Magazine. pp. 80–87. Retrieved 24 June 2021.