A loop-gap resonator (LGR) is an electromagnetic resonator that operates in the radio and microwave frequency ranges. The simplest LGRs are made from a conducting tube with a narrow slit cut along its length. [1] [2] The LGR dimensions are typically much smaller than the free-space wavelength of the electromagnetic fields at the resonant frequency. Therefore, relatively compact LGRs can be designed to operate at frequencies that are too low to be accessed using, for example, cavity resonators. These structures can have very sharp resonances (high quality factors) making them useful for electron spin resonance (ESR) experiments, [3] [4] and precision measurements of electromagnetic material properties (permittivity and permeability). [5]
Loop-gap resonators (LGRs) can be modelled as lumped-element circuits. The slit along the length of the resonator has an effective capacitance and the bore of the resonator has effective inductance . At, or near, the resonance frequency, a circumferential current is established along the inner wall of the resonator. The effective resistance that limits this current is, in part, determined by the resistivity and electromagnetic skin depth of the conductor used to make the LGR. [1] It is, therefore, possible to model the LGR as an circuit. Since the LGR current is a maximum at the resonant frequency, the equivalent circuit model is a series circuit. This circuit model works well provided the dimensions of the resonator remain small compared to the free-space wavelength of the electromagnetic fields. [6]
One advantage of the LGR is that it produces regions of uniform electric and magnetic fields that are isolated from one another. A uniform electric field exists within the slit of the LGR and a uniform magnetic field exists within the bore of the resonator. The uniform magnetic field makes the LGR a good source of microwave magnetic fields in ESR experiments. Furthermore, because the electric and magnetic fields are isolated from one another, one can use the LGR to independently probe the electric and magnetic properties of materials. For example, if the gap of the LGR is filled with a dielectric material, the effective capacitance of the LGR will be modified which will change the frequency and quality factor of the resonance. Measurements of the changes in and can be used to fully determine the complex permittivity of the dielectric material. Likewise, if the bore of the LGR is filled with a magnetic material, the effective inductance of the LGR will be modified and the resulting changes in and can be used to extract the complex permeability of the magnetic material. [5] [7]
The capacitance of the gap of the LGR is given by
where is the permittivity of free space, is the thickness of the bore wall, is the gap width, and is the length of the resonator. The resonator bore acts as a single-turn solenoid with inductance given by
where is the permeability of free space and is the inner radius of the LGR bore. For a high- resonator, the resonant frequency is, to an approximation, given by
where is the vacuum speed of light. Therefore, the resonant frequency of the LGR is determined from its geometry and is, to first approximation, independent of its length.
For a highly underdamped series circuit, the quality factor, which determines the sharpness of the resonance, is given by
The effective resistance of a LGR can be estimated by considering the length of conductor through which the current travels and the cross-sectional area available to it. The relevant conductor length is the circumference of the conductor's inner surface. The depth that the current penetrates into the inner surface of the LGR bore is determined by the electromagnetic skin depth . Therefore, the cross-sectional area through which charge flows is . Combining these results gives an effective resistance
where is the resistivity of the conductor. The effective capacitance, inductance, and resistance then lead to a simple expression for the expected quality factor of the LGR
where, for a good conductor, the electromagnetic skin depth at the resonance frequency is given by
and . For an aluminum resonator with and the above analysis predicts . [1] [6]
In practice, the measured quality factor a cylindrical LGR, without additional electromagnetic shielding, will be much less than the predicted value of . The suppression of the quality factor is due to radiative power loss from magnetic field lines that extend out of LGR bore and into free space. An order-of-magnitude estimate of the effective radiation resistance can be made by treating the LGR as a conducting loop. In the limit that the wavelength of the radiation is much larger than the loop radius , the radiation resistance is
and can be much larger than the resistance due to the resistivity of the LGR conductor. [8] [9] The radiative losses can be suppressed by placing the LGR inside a circular waveguide. Provided that the cutoff frequency of the lowest TE11 waveguide mode is well above the resonant frequency of the LGR, the magnetic field lines will be prevented from propagating into free space. The presence of the electromagnetic shield will alter the resonant frequency and quality factor of the LGR, but typically by only a few percent. [1] [6]
In some applications requiring high quality factors, the electromagnetic shielding provided by a concentric circular waveguide surrounding a cylindrical LGR can be bulky and awkward to work. A toroidal LGR can be used for high- measurements without requiring additional electromagnetic shielding. In the toroidal geometry the two ends of a cylindrical LGR are joined to form a completely closed structure. In this case, the magnetic field is completely confined within the bore of the resonator and there is no radiative power loss. The toroidal LGR consists of two halves that are bolted together along the outer diameter of the structure.
Like the cylindrical LGR, the toroidal LGR can be modelled as a series circuit. In general, the effective capacitance, inductance, and resistance of the toroidal LGR will differ from the expressions given above for the cylindrical LGR. However, in limit that the radius of the torus is large compared to the bore radius , the capacitance, inductance, and resistance of the toroidal LGR are approximated by the expressions above if one takes to be equal to the circumference of the torus.
The toroidal LGR is particularly convenient when characterizing the electromagnetic properties of liquid samples or particles suspended in a liquid. In these cases, the bore of the toroidal LGR can be partially filled with the liquid sample without requiring a special sample holder. This setup allows one to characterize the magnetic properties of, for example, a ferrofluid. Alternatively, if the liquid sample is nonmagnetic, the entire toroidal LGR can be submerged in the liquid (or gas). In this case, the dielectric properties of the sample only modify the effective capacitance of the resonator and the changes in and can be used to determine the complex permittivity of the sample. [7] [9]
Inductive coupling loops are typically used to couple magnetic flux into and out of the LGR. The coupling loops are made by first removing a length of outer conductor and dielectric from a semi-rigid coaxial cable. The exposed centre conductor is then bent into a loop and short-circuited to the outer conductor. The opposite end of the coaxial cable is connected to either a signal generator or a receiver. In the case of a signal generator, an oscillating current is established in the coupling loop. By Faraday's law of induction, this current creates and oscillating magnetic flux which can be coupled into the bore of the LGR. This magnetic flux, in turn, induces circumferential currents along the inner wall of the LGR. The induced current, once again by Faraday's law, creates an approximately uniform oscillating magnetic field in the bore of the LGR. A second coupling loop, connected to a receiver, can be used to detect the magnetic flux produced by the LGR. Alternatively, using a vector network analyzer (VNA), a single coupling loop can be used to both inject a signal into the LGR and measure its response. The VNA can measure the ratio of the forward and reflected voltages (, or reflection coefficient) as a function of microwave frequency. Far away from resonance, the magnitude of the reflection coefficient will be close to one since very little power is coupled into the LGR at these frequencies. However, near the resonance frequency , the magnitude of the reflection coefficient will fall below one as power is transferred into the LGR. The coupling between the external circuits and the LGR can be tuned by adjusting the relative positions and orientations of the coupling loop and LGR. At critical coupling, impedance matching is achieved and the reflection coefficient approaches zero. [11]
It is also possible to capacitively couple electric fields into and out of the gap of the LGR using suitably-fashioned electrodes at the end of a coaxial cable. [11]
Multi-loop, multi-gap LGRs have also been developed. The simplest of these is the two-loop, one-gap LGR. In this case, magnetic field lines form closed loops by passing through each of the bores of the LGR and the currents on the inner walls propagate in opposite directions - clockwise in one bore and counterclockwise in the other. The equivalent circuit, neglecting losses, is a parallel combination of inductors and in series with capacitance . If , then the resonant frequency of the two-loop, one-gap LGR is times greater than that of the conventional one-loop, one-gap LGR having the same bore and gap dimensions. It is also worth noting that, since magnetic field lines pass from one bore to the other, radiative power losses are strongly suppressed and the resonator maintains a high quality factor without requiring additional electromagnetic shielding. [10] [13]
The multi-loop, multi-gap LGRs with more than two loops have more than one resonant mode. If the central bore is singled out as having inductance , then one of the resonant modes is one in which all of the magnetic flux from each of the external loops of inductance is shared with the central loop. For this mode, the resonant frequency of an -loop, -gap LGR is given by
where it has been assumed that all loops have the same inductance . [14] [15] [16] [17] [18]
Loop-gap resonators have been used to make precise measurements of the electrodynamic properties of unconventional superconductors. [19] Most notably, a LGR was used to reveal the linear temperature dependence of the magnetic penetration depth, characteristic of a d-wave superconductor, in a single crystal of YBa2Cu3O6.95. [20] In these experiments, a superconducting sample is placed inside the bore of a LGR. The diamagnetic response of the superconductor alters in the inductance of the LGR and, therefore, its resonant frequency. As described below, tracking the change in the resonant frequency as the temperature of the sample is changed allows one to deduce the temperature dependence of the magnetic penetration depth.
The inductance of the LGR can be expressed as , where is the volume of the LGR bore. Since the resonant frequency of the LGR is proportional to , a small change in the effective volume of the resonator bore will result in a change in the resonant frequency given by
Due to the Meissner effect, when a superconducting sample is placed in the bore of a LGR, the magnetic flux is expelled from the interior of the sample to within a penetration depth of its surface. Therefore, the effective volume of the resonator bore is reduced by an amount equal to the volume from which the magnetic flux has been excluded. This excluded volume is given by
where , , and are the sample dimensions along the three crystallographic directions and is the sample volume . In the above expression, it has been assumed that the microwave magnetic field is applied parallel to the -axis of the sample. Since the presence of the superconductor reduces the LGR volume, and
Solving this expression for the -axis penetration depth yields
Generally, it is not possible to use LGR frequency-shift measurements to determine the absolute value of the penetration depth because it would require knowing the sample thickness very precisely. For example, in fully doped YBa2Cu3O7, at low temperature. [21] Therefore, to use the LGR measurement to determine to within 10%, one would have to know the value of with an accuracy of which is typically not possible.
Instead, the strategy is to track the changes in frequency as the sample temperature varies (while keeping the LGR at a fixed temperature). The absolute penetration depth can be expressed as
where is temperature, is the experimental base temperature, and is the change in penetration depth as the sample temperature is increased above the base temperature. One can, therefore, express the change in penetration depth as
Finally, defining , one has
This final expression shows how the LGR shifts in resonant frequency can be used to determine the temperature dependence of the magnetic penetration depth in a superconducting sample.
In a d-wave superconductor, the penetration depth typically changes by a few ångströms per degree kelvin, which corresponds to for a platelet sample in a LGR with a bore volume of . Measuring such small changes in relative frequency requires an extremely high- resonator. The ultrahigh quality factors are obtained by coating the LGR surfaces with a superconducting material, such as a lead-tin alloy. The resonator is then cooled below the superconducting transition temperature of the coating using a bath of superfluid liquid helium. Quality factors of have been achieved using copper LGRs coated with lead-tin and cooled to . [20]
This section describes how LGRs can be used to determine the electromagnetic properties of materials. When there are no materials filling either the gap or bore of the resonator, the impedance of the LGR can be expressed as
where . Re-expressed in terms of the resonant frequency and quality factor , the impedance is given by
A measurement of the frequency dependence of the impedance of an empty LGR can be used to determine and . The impedance measurement is most easily done using the vector network analyzer (VNA) to measure the reflection coefficient from an inductively-coupled LGR. The impedance and reflection coefficient are related by
where is the output impedance of the VNA (usually, ).
Now suppose that the gap of resonator has been completely filled with a dielectric material that has complex relative permittivity . In this case, the effective capacitance becomes and the impedance of the LGR is given by
Separating the real and imaginary terms leads to
This expression shows that a nonzero enhances the effective resistance of the LGR and, therefore, lowers its quality factor. A nonzero , on the other hand, alters the imaginary part of the impedance and modifies the resonant frequency. Written in terms of the empty-resonator resonant frequency and quality factor, the above impedance can be expressed as
Provided that and are known before hand, a measurement of the frequency dependence of can be used to determine and of the material filling the gap of the LGR. This analysis gives the values of and at the resonant frequency of the filled LGR. [5] [6] [7]
Next, suppose that the bore of a LGR is filled with a magnetic material have complex relative permeability . In this case, the effective inductance becomes and the impedance of the LGR is given by
Separating into its real and imaginary components and writing the impedance in terms of and of the empty LGR yields
Once again, contributes additional dissipation which lowers the quality factor of the filled resonator and shifts the resonant frequency. A measurement of the frequency dependence of can be used to extract the values of and at the resonant frequency of the filled LGR. [5] [10] [12] [22]
In physics, the cross section is a measure of the probability that a specific process will take place in a collision of two particles. For example, the Rutherford cross-section is a measure of probability that an alpha particle will be deflected by a given angle during an interaction with an atomic nucleus. Cross section is typically denoted σ (sigma) and is expressed in units of area, more specifically in barns. In a way, it can be thought of as the size of the object that the excitation must hit in order for the process to occur, but more exactly, it is a parameter of a stochastic process.
Maxwell's equations, or Maxwell–Heaviside equations, are a set of coupled partial differential equations that, together with the Lorentz force law, form the foundation of classical electromagnetism, classical optics, electric and magnetic circuits. The equations provide a mathematical model for electric, optical, and radio technologies, such as power generation, electric motors, wireless communication, lenses, radar, etc. They describe how electric and magnetic fields are generated by charges, currents, and changes of the fields. The equations are named after the physicist and mathematician James Clerk Maxwell, who, in 1861 and 1862, published an early form of the equations that included the Lorentz force law. Maxwell first used the equations to propose that light is an electromagnetic phenomenon. The modern form of the equations in their most common formulation is credited to Oliver Heaviside.
The wave impedance of an electromagnetic wave is the ratio of the transverse components of the electric and magnetic fields. For a transverse-electric-magnetic (TEM) plane wave traveling through a homogeneous medium, the wave impedance is everywhere equal to the intrinsic impedance of the medium. In particular, for a plane wave travelling through empty space, the wave impedance is equal to the impedance of free space. The symbol Z is used to represent it and it is expressed in units of ohms. The symbol η (eta) may be used instead of Z for wave impedance to avoid confusion with electrical impedance.
In electromagnetism, the absolute permittivity, often simply called permittivity and denoted by the Greek letter ε (epsilon), is a measure of the electric polarizability of a dielectric material. A material with high permittivity polarizes more in response to an applied electric field than a material with low permittivity, thereby storing more energy in the material. In electrostatics, the permittivity plays an important role in determining the capacitance of a capacitor.
A Fermi gas is an idealized model, an ensemble of many non-interacting fermions. Fermions are particles that obey Fermi–Dirac statistics, like electrons, protons, and neutrons, and, in general, particles with half-integer spin. These statistics determine the energy distribution of fermions in a Fermi gas in thermal equilibrium, and is characterized by their number density, temperature, and the set of available energy states. The model is named after the Italian physicist Enrico Fermi.
In physics and engineering, the quality factor or Q factor is a dimensionless parameter that describes how underdamped an oscillator or resonator is. It is defined as the ratio of the initial energy stored in the resonator to the energy lost in one radian of the cycle of oscillation. Q factor is alternatively defined as the ratio of a resonator's centre frequency to its bandwidth when subject to an oscillating driving force. These two definitions give numerically similar, but not identical, results. Higher Q indicates a lower rate of energy loss and the oscillations die out more slowly. A pendulum suspended from a high-quality bearing, oscillating in air, has a high Q, while a pendulum immersed in oil has a low one. Resonators with high quality factors have low damping, so that they ring or vibrate longer.
In electromagnetism, skin effect is the tendency of an alternating electric current (AC) to become distributed within a conductor such that the current density is largest near the surface of the conductor and decreases exponentially with greater depths in the conductor. It is caused by opposing eddy currents induced by the changing magnetic field resulting from the alternating current. The electric current flows mainly at the skin of the conductor, between the outer surface and a level called the skin depth.
In the calculus of variations and classical mechanics, the Euler–Lagrange equations are a system of second-order ordinary differential equations whose solutions are stationary points of the given action functional. The equations were discovered in the 1750s by Swiss mathematician Leonhard Euler and Italian mathematician Joseph-Louis Lagrange.
The path integral formulation is a description in quantum mechanics that generalizes the stationary action principle of classical mechanics. It replaces the classical notion of a single, unique classical trajectory for a system with a sum, or functional integral, over an infinity of quantum-mechanically possible trajectories to compute a quantum amplitude.
In physics, the Hamilton–Jacobi equation, named after William Rowan Hamilton and Carl Gustav Jacob Jacobi, is an alternative formulation of classical mechanics, equivalent to other formulations such as Newton's laws of motion, Lagrangian mechanics and Hamiltonian mechanics.
In quantum physics, Fermi's golden rule is a formula that describes the transition rate from one energy eigenstate of a quantum system to a group of energy eigenstates in a continuum, as a result of a weak perturbation. This transition rate is effectively independent of time and is proportional to the strength of the coupling between the initial and final states of the system as well as the density of states. It is also applicable when the final state is discrete, i.e. it is not part of a continuum, if there is some decoherence in the process, like relaxation or collision of the atoms, or like noise in the perturbation, in which case the density of states is replaced by the reciprocal of the decoherence bandwidth.
In quantum mechanics, a two-state system is a quantum system that can exist in any quantum superposition of two independent quantum states. The Hilbert space describing such a system is two-dimensional. Therefore, a complete basis spanning the space will consist of two independent states. Any two-state system can also be seen as a qubit.
The electromagnetic wave equation is a second-order partial differential equation that describes the propagation of electromagnetic waves through a medium or in a vacuum. It is a three-dimensional form of the wave equation. The homogeneous form of the equation, written in terms of either the electric field E or the magnetic field B, takes the form:
An electromagnetic reverberation chamber (also known as a reverb chamber (RVC) or mode-stirred chamber (MSC)) is an environment for electromagnetic compatibility (EMC) testing and other electromagnetic investigations. Electromagnetic reverberation chambers have been introduced first by H.A. Mendes in 1968. A reverberation chamber is screened room with a minimum of absorption of electromagnetic energy. Due to the low absorption, very high field strength can be achieved with moderate input power. A reverberation chamber is a cavity resonator with a high Q factor. Thus, the spatial distribution of the electrical and magnetic field strengths is strongly inhomogeneous (standing waves). To reduce this inhomogeneity, one or more tuners (stirrers) are used. A tuner is a construction with large metallic reflectors that can be moved to different orientations in order to achieve different boundary conditions. The Lowest Usable Frequency (LUF) of a reverberation chamber depends on the size of the chamber and the design of the tuner. Small chambers have a higher LUF than large chambers.
The Voigt effect is a magneto-optical phenomenon which rotates and elliptizes linearly polarised light sent into an optically active medium. The effect is named after the German scientist Woldemar Voigt who discovered it in vapors. Unlike many other magneto-optical effects such as the Kerr or Faraday effect which are linearly proportional to the magnetization, the Voigt effect is proportional to the square of the magnetization and can be seen experimentally at normal incidence. There are also other denominations for this effect, used interchangeably in the modern scientific literature: the Cotton–Mouton effect and magnetic-linear birefringence, with the latter reflecting the physical meaning of the effect.
In electrical engineering, dielectric loss quantifies a dielectric material's inherent dissipation of electromagnetic energy. It can be parameterized in terms of either the loss angleδ or the corresponding loss tangenttan(δ). Both refer to the phasor in the complex plane whose real and imaginary parts are the resistive (lossy) component of an electromagnetic field and its reactive (lossless) counterpart.
When an electromagnetic wave travels through a medium in which it gets attenuated, it undergoes exponential decay as described by the Beer–Lambert law. However, there are many possible ways to characterize the wave and how quickly it is attenuated. This article describes the mathematical relationships among:
An RLC circuit is an electrical circuit consisting of a resistor (R), an inductor (L), and a capacitor (C), connected in series or in parallel. The name of the circuit is derived from the letters that are used to denote the constituent components of this circuit, where the sequence of the components may vary from RLC.
The non-radiative dielectric (NRD) waveguide was introduced by Yoneyama in 1981. In Fig. 1 the crosses shown: it consists of a dielectric rectangular slab of height (a) and width (b), which is placed between two metallic parallel plates of a suitable width. The structure is practically the same as the H waveguide, proposed by Tischer in 1953. Due to the dielectric slab, the electromagnetic field is confined in the vicinity of the dielectric region, whereas in the outside region for suitable frequencies, the electromagnetic field decays exponentially. Therefore, if the metallic plates are sufficiently extended, the field is practically negligible at the end of the plates and therefore the situation does not greatly differ from the ideal case in which the plates are infinitely extended. The polarization of the electric field in the required mode is mainly parallel to the conductive walls. As it is known, if the electric field is parallel to the walls, the conduction losses decrease in the metallic walls at the increasing frequency, whereas, if the field is perpendicular to the walls, losses increase at the increasing frequency. Since the NRD waveguide has been devised for its implementation at millimeter waves, the selected polarization minimizes the ohmic losses in the metallic walls.
In mathematics and electronics, cavity perturbation theory describes methods for derivation of perturbation formulae for performance changes of a cavity resonator.