Copper in heat exchangers

Last updated

Heat exchangers are devices that transfer heat to achieve desired heating or cooling. An important design aspect of heat exchanger technology is the selection of appropriate materials to conduct and transfer heat fast and efficiently.

Contents

Copper has many desirable properties for thermally efficient and durable heat exchangers. First and foremost, copper is an excellent conductor of heat. This means that copper's high thermal conductivity allows heat to pass through it quickly. Other desirable properties of copper in heat exchangers include its corrosion resistance, biofouling resistance, maximum allowable stress and internal pressure, creep rupture strength, fatigue strength, hardness, thermal expansion, specific heat, antimicrobial properties, tensile strength, yield strength, high melting point, alloy, ease of fabrication, and ease of joining.

The combination of these properties enable copper to be specified for heat exchangers in industrial facilities, HVAC systems, vehicular coolers and radiators, and as heat sinks to cool computers, disk drives, televisions, computer monitors, and other electronic equipment. [1] Copper is also incorporated into the bottoms of high-quality cookware because the metal conducts heat quickly and distributes it evenly.

Non-copper heat exchangers are also available. Some alternative materials include aluminum, carbon steel, stainless steel, nickel alloys, and titanium.

This article focuses on beneficial properties and common applications of copper in heat exchangers. New copper heat exchanger technologies for specific applications are also introduced.

History

Heat exchangers using copper and its alloys have evolved along with heat transfer technologies over the past several hundred years. Copper condenser tubes were first used in 1769 for steam engines. Initially, the tubes were made of unalloyed copper. By 1870, Muntz metal, a 60% Cu-40% Zn brass alloy, was used for condensers in seawater cooling. Admiralty metal, a 70% Cu-30% Zn yellow brass alloy with 1% tin added to improve corrosion resistance, was introduced in 1890 for seawater service. [2] By the 1920s, a 70% Cu-30% Ni alloy was developed for naval condensers. Soon afterwards, a 2% manganese and 2% iron copper alloy was introduced for better erosion resistance. A 90% Cu-10% Ni alloy first became available in the 1950s, initially for seawater piping. This alloy is now the most widely used copper-nickel alloy in marine heat exchangers.

Today, steam, evaporator, and condenser coils are made from copper and copper alloys. [3] These heat exchangers are used in air conditioning and refrigeration systems, industrial and central heating and cooling systems, radiators, hot water tanks, and under-floor heating systems.

Copper-based heat exchangers can be manufactured with copper tube/aluminum fin, cupro-nickel, or all-copper constructions. Various coatings can be applied to enhance corrosion resistance of the tubes and fins. [3] [4]

Beneficial properties of copper heat exchangers

Thermal conductivity

Thermal conductivity (k, also denoted as λ or κ) is a measure of a material's ability to conduct heat. Heat transfer across materials of high thermal conductivity occurs at a higher rate than across materials of low thermal conductivity. In the International System of Units (SI), thermal conductivity is measured in watts per meter Kelvin (W/(m•K)). In the Imperial System of Measurement (British Imperial, or Imperial units), thermal conductivity is measured in Btu/(hr•ft⋅F).

Copper has a thermal conductivity of 231 Btu/(hr-ft-F). This is higher than all other metals except silver, a precious metal. Copper has a 60% better thermal conductivity rating than aluminum and has almost 30 times more thermal conductivity than stainless steel. [5]

Thermal conductivity of some common metals [6]
MetalThermal conductivity
(Btu/(hr-ft-F))(W/(m•K))
Silver247.87429
Copper231399
Gold183316
Aluminium136235
Yellow brass69.33120
Cast iron46.3380.1
Stainless steel8.114.0

Further information about the thermal conductivity of selected metals is available. [7]

Corrosion resistance

Corrosion resistance is essential in heat transfer applications where fluids are involved, such as in hot water tanks, radiators, etc. The only affordable material that has similar corrosion resistance to copper is stainless steel. However, the thermal conductivity of stainless steel is 1/30th times than that of copper. Aluminum tubes are not suitable for potable or untreated water applications because it corrodes at pH<7.0 and so it releases hydrogen gas. [8] [9] [10]

Protective films can be applied to the inner surface of copper alloy tubes to increase corrosion resistance. For certain applications, the film is composed of iron. In power plant condensers, duplex tubes consisting of an inner titanium layer with outer copper-nickel alloys are employed. This enables the use of copper’s beneficial mechanical and chemical properties (e.g., stress corrosion cracking, ammonia attack) along with titanium’s excellent corrosion resistance. A duplex tube with inner aluminium brass or copper-nickel and outer stainless or mild steel can be used for cooling in the oil refining and petrochemical industries. [11]

Biofouling resistance

Copper and copper-nickel alloys have a high natural resistance to biofouling relative to alternative materials. Other metals used in heat exchangers, such as steel, titanium and aluminum, foul readily. Protection against biofouling, particularly in marine structures, can be accomplished over long periods of time with copper metals.

Copper-nickel alloys have been proven over many years in sea water pipework and other marine applications. These alloys resist biofouling in open seas where they do not allow microbial slime to build up and support macrofouling. [12]

Researchers attribute copper's resistance to biofouling, even in temperate waters, to two possible mechanisms: 1) a retarding sequence of colonization through slow release of copper ions during the corrosion process, thereby inhibiting the attachment of microbial layers to marine surfaces; [13] and/or, 2) separating layers that contain corrosive products and the larvae of macro-encrusting organisms. [14] The latter mechanism deters the settlement of pelagic larval stages on the metal surface, rather than killing the organisms.

Antimicrobial properties

Due to copper’s strong antimicrobial properties, copper fins can inhibit bacterial, fungal and viral growths that commonly build up in air conditioning systems. Hence, the surfaces of copper-based heat exchangers are cleaner for longer periods of time than heat exchangers made from other metals. This benefit offers a greatly expanded heat exchanger service life and contributes to improved air quality. Heat exchangers fabricated separately from antimicrobial copper and aluminum in a full-scale HVAC system have been evaluated for their ability to limit microbial growth under conditions of normal flow rates using single-pass outside air. Commonly used aluminum components developed stable biofilms of bacteria and fungi within four weeks of operation. During the same time period, antimicrobial copper was able to limit bacterial loads associated with the copper heat exchanger fins by 99.99% and fungal loads by 99.74%. [15] [16] [17]

Copper fin air conditioners have been deployed on buses in Shanghai to rapidly and completely kill bacteria, viruses and fungi that were previously thriving on non-copper fins and permitted to circulate around the systems. The decision to replace aluminum with copper followed antimicrobial tests by the Shanghai Municipal Center for Disease Control and Prevention (SCDC) from 2010 to 2012. The study found that microbial levels on copper fin surfaces were significantly lower than on aluminum, thereby helping to protect the health of bus passengers. [17] [18]

Further information about the benefits of antimicrobial copper in HVAC systems is available. [19] [20] [21]

Ease of inner grooving

Internally grooved copper tube of smaller diameters is more thermally efficient, materially efficient, and easier to bend and flare and otherwise work with. It is generally easier to make inner grooved tubes out of copper, a very soft metal.

Common applications for copper heat exchangers

Industrial facilities and power plants

Copper alloys are extensively used as heat exchanger tubing in fossil and nuclear steam generating electric power plants, chemical and petrochemical plants, marine services, and desalination plants.

The largest use of copper alloy heat exchanger tubing on a per unit basis is in utility power plants. These plants contain surface condensers, heaters, and coolers, all of which contain copper tubing. The main surface condenser that accepts turbine-steam discharges uses the most copper. [2]

Copper nickel is the group of alloys that are commonly specified in heat exchanger or condenser tubes in evaporators of desalination plants, process industry plants, air cooling zones of thermal power plants, high-pressure feed water heaters, and sea water piping in ships. [11] The composition of the alloys can vary from 90% Cu–10% Ni to 70% Cu–30% Ni.

Condenser and heat exchanger tubing of arsenical admiralty brass (Cu-Zn-Sn-As) once dominated the industrial facility market. Aluminum brass later rose in popularity because of its enhanced corrosion resistance. [22] Today, aluminum-brass, 90%Cu-10%Ni, and other copper alloys are widely used in tubular heat exchangers and piping systems in seawater, brackish water and fresh water. Aluminum-brass, 90% Cu-10% Ni and 70% Cu-30% Ni alloys show good corrosion resistance in hot de-aerated seawater and in brines in multi-stage flash desalination plants. [23] [24]

Fixed tube liquid-cooled heat exchangers especially suitable for marine and harsh applications can be assembled with brass shells, copper tubes, brass baffles, and forged brass integral end hubs. [25]

Copper alloy tubes can be supplied either with a bright metallic surface (CuNiO) or with a thin, firmly attached oxide layer (aluminum brass). These finish types allow for the formation of a protective layer. [24] The protective oxide surface is best achieved when the system is operated for several weeks with clean, oxygen containing cooling water. While the protective layer forms, supportive measures can be carried out to enhance the process, such as the addition of iron sulfate or intermittent tube cleaning. The protective film that forms on Cu-Ni alloys in aerated seawater becomes mature in about three months at 60 °F and becomes increasingly protective with time. The film is resistant to polluted waters, irregular velocities, and other harsh conditions. Further details are available. [26]

The biofouling resistance of Cu-Ni alloys enables heat exchange units to operate for several months between mechanical cleanings. Cleanings are nevertheless needed to restore original heat transfer capabilities. Chlorine injection can extend the mechanical cleaning intervals to a year or more without detrimental effects on the Cu-Ni alloys.

Further information about copper alloy heat exchangers for industrial facilities is available. [27] [28] [29] [30]

Solar thermal water systems

Solar water heaters can be a cost-effective way to generate hot water for homes in many regions of the world. Copper heat exchangers are important in solar thermal heating and cooling systems because of copper's high thermal conductivity, resistance to atmospheric and water corrosion, sealing and joining by soldering, and mechanical strength. Copper is used both in receivers and in primary circuits (pipes and heat exchangers for water tanks) of solar thermal water systems. [31]

Various types of solar collectors for residential applications are available with either direct circulation (i.e., heats water and brings it directly to the home for use) or indirect circulation (i.e., pumps a heat transfer fluid through a heat exchanger, which then heats water that flows into the home) systems. [32] In an evacuated tube solar hot water heater with an indirect circulation system, the evacuated tubes contain a glass outer tube and metal absorber tube attached to a fin. Solar thermal energy is absorbed within the evacuated tubes and is converted into usable concentrated heat. Evacuated glass tubes have a double layer. Inside the glass tube is the copper heat pipe. It is a sealed hollow copper tube that contains a small amount of thermal transfer fluid (water or glycol mixture) which under low pressure boils at a very low temperature. The copper heat pipe transfers thermal energy from within the solar tube into a copper header. As the solution circulates through the copper header, the temperature rises.

Other components in solar thermal water systems that contain copper include solar heat exchanger tanks and solar pumping stations, along with pumps and controllers. [33] [34] [35] [36] [37]

HVAC systems

Air conditioning and heating in buildings and motor vehicles are two of the largest applications for heat exchangers. While copper tube is used in most air conditioning and refrigeration systems, typical air conditioning units currently use aluminum fins. These systems can harbor bacteria and mold and develop odors and fouling that can make them function poorly. [38] Stringent new requirements including demands for increased operating efficiencies and the reduction or elimination of harmful emissions are enhancing copper's role in modern HVAC systems. [39]

Copper’s antimicrobial properties can enhance the performance of HVAC systems and associated indoor air quality. After extensive testing, copper became a registered material in the U.S. for protecting heating and air conditioning equipment surfaces against bacteria, mold, and mildew. Furthermore, testing funded by the U.S. Department of Defense is demonstrating that all-copper air conditioners suppress the growth of bacteria, mold and mildew that cause odors and reduce system energy efficiency. Units made with aluminum have not been demonstrating this benefit. [40] [41]

Copper can cause a galvanic reaction in the presence of other alloys, leading to corrosion. [42]

Gas water heaters

Water heating is the second largest energy use in the home. Gas-water heat exchangers that transfer heat from gaseous fuels to water between 3 and 300 kilowatts thermal (kWth) have widespread residential and commercial use in water heating and heating boiler appliance applications.

Demand is increasing for energy-efficient compact water heating systems. Tankless gas water heaters produce hot water when needed. Copper heat exchangers are the preferred material in these units because of their high thermal conductivity and ease of fabrication. To protect these units in acidic environments, durable coatings or other surface treatments are available. Acid-resistant coatings are capable of withstanding temperatures of 1000 °C. [43] [44]

Forced air heating and cooling

Air-source heat pumps have been used for residential and commercial heating and cooling for many years. These units rely on air-to-air heat exchange through evaporator units similar to those used for air conditioners. Finned water to air heat exchangers are most commonly used for forced air heating and cooling systems, such as with indoor and outdoor wood furnaces, boilers, and stoves. They can also be suitable for liquid cooling applications. Copper is specified in supply and return manifolds and in tube coils. [8]

Direct Exchange (DX) Geothermal Heating/Cooling

Geothermal heat pump technology, variously known as "ground source," "earth-coupled," or "direct exchange," relies on circulating a refrigerant through buried copper tubing for heat exchange. These units, which are considerably more efficient than their air-source counterparts, rely on the constancy of ground temperatures below the frost zone for heat transfer. The most efficient ground source heat pumps use ACR, Type L or special-size copper tubing buried into the ground to transfer heat to or from the conditioned space. Flexible copper tube (typically 1/4-inch to 5/8-inch) can be buried in deep vertical holes, horizontally in a relatively shallow grid pattern, in a vertical fence-like arrangement in medium-depth trenches, or as custom configurations. Further information is available. [45]

Electronic systems

Copper and aluminum are used as heat sinks and heat pipes in electronic cooling applications. A heat sink is a passive component that cools semiconductor and optoelectronic devices by dissipating heat into the surrounding air. Heat sinks have temperatures higher than their surrounding environments so that heat can be transferred into the air by convection, radiation, and conduction.

Aluminum is the most prominently used heat sink material because of its lower cost. [46] Copper heat sinks are a necessity when higher levels of thermal conductivity are needed. An alternative to all-copper or all-aluminum heat sinks is the joining of aluminum fins to a copper base. [47]

Copper heat sinks are die-cast and bound together in plates. They spread heat quickly from the heat source to copper or aluminum fins and into the surrounding air.

Heat pipes are used to move heat away from central processing units (CPUs) and graphics processing units (GPUs) and towards heat sinks, where thermal energy is dissipated into the environment. Copper and aluminum heat pipes are used extensively in modern computer systems where increased power requirements and associated heat emissions result in greater demands on cooling systems.

A heat pipe typically consists of a sealed pipe or tube at both the hot and cold ends. Heat pipes utilize evaporative cooling to transfer thermal energy from one point to another by the evaporation and condensation of a working fluid or coolant. They are fundamentally better at heat conduction over larger distances than heat sinks because their effective thermal conductivity is several orders of magnitude greater than that of the equivalent solid conductor. [48]

When it is desirable to maintain junction temperatures below 125–150 °C, copper/water heat pipes are typically used. Copper/methanol heat pipes are used if the application requires heat pipe operations below 0 °C. [49]

New technologies

Internally Grooved

The benefits of smaller-diameter internally grooved copper tube for heat transfer are well documented. [50] [51]

Smaller diameter coils have better rates of heat transfer than conventional sized coils so that they can withstand higher pressures required by the new generation of environmentally friendlier refrigerants. Smaller diameter coils also have lower material costs because they require less refrigerant, fin, and coil materials; and they enable the design of smaller and lighter high-efficiency air conditioners and refrigerators because the evaporators and condensers coils are smaller and lighter. MicroGroove uses a grooved inner surface of the tube to increase the surface to volume ratio and increase turbulence to mix the refrigerant and homogenize temperatures across the tube. [52] [53] [54]

3D Printing

A new technology to make heat exchangers is 3D Printing. With 3D printing, you can create complex forms and inside channels. This results in high performance of heat exchangers. [55] The heat exchanger printed is mainly for the industry. The heat exchangers can be printed in pure copper, CuCrZr, and CuNi2SiCr alloy.

Related Research Articles

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

<span class="mw-page-title-main">Heat exchanger</span> Equipment used to transfer heat between fluids

A heat exchanger is a system used to transfer heat between a source and a working fluid. Heat exchangers are used in both cooling and heating processes. The fluids may be separated by a solid wall to prevent mixing or they may be in direct contact. They are widely used in space heating, refrigeration, air conditioning, power stations, chemical plants, petrochemical plants, petroleum refineries, natural-gas processing, and sewage treatment. The classic example of a heat exchanger is found in an internal combustion engine in which a circulating fluid known as engine coolant flows through radiator coils and air flows past the coils, which cools the coolant and heats the incoming air. Another example is the heat sink, which is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant.

Beryllium copper (BeCu), also known as copper beryllium (CuBe), beryllium bronze, and spring copper, is a copper alloy with 0.5–3% beryllium. Copper beryllium alloys are often used because of their high strength and good conductivity of both heat and electricity. It is used for its ductility, weldability in metalworking, and machining properties. It has many specialized applications in tools for hazardous environments, musical instruments, precision measurement devices, bullets, and some uses in the field of aerospace. Beryllium copper and other beryllium alloys are harmful carcinogens that present a toxic inhalation hazard during manufacturing.

Cupronickel or copper-nickel (CuNi) is an alloy of copper with nickel, usually along with small quantities of other elements added for strength, such as iron and manganese. The copper content typically varies from 60 to 90 percent.

<span class="mw-page-title-main">Brazing</span> Metal-joining technique

Brazing is a metal-joining process in which two or more metal items are joined by melting and flowing a filler metal into the joint, with the filler metal having a lower melting point than the adjoining metal.

<span class="mw-page-title-main">Heat sink</span> Passive heat exchanger that transfers the heat

A heat sink is a passive heat exchanger that transfers the heat generated by an electronic or a mechanical device to a fluid medium, often air or a liquid coolant, where it is dissipated away from the device, thereby allowing regulation of the device's temperature. In computers, heat sinks are used to cool CPUs, GPUs, and some chipsets and RAM modules. Heat sinks are used with high-power semiconductor devices such as power transistors and optoelectronics such as lasers and light-emitting diodes (LEDs), where the heat dissipation ability of the component itself is insufficient to moderate its temperature.

<span class="mw-page-title-main">Heat pipe</span> Heat-transfer device that employs phase transition

A heat pipe is a heat-transfer device that employs phase transition to transfer heat between two solid interfaces.

<span class="mw-page-title-main">Solar thermal collector</span> Device that collects heat

A solar thermal collector collects heat by absorbing sunlight. The term "solar collector" commonly refers to a device for solar hot water heating, but may refer to large power generating installations such as solar parabolic troughs and solar towers or non water heating devices such as solar cooker, solar air heaters.

<span class="mw-page-title-main">Monel</span> Solid-solution binary alloy of nickel and copper

Monel is a group of alloys of nickel and copper, with small amounts of iron, manganese, carbon, and silicon. Monel is not a cupronickel alloy because it has less than 60% copper.

<span class="mw-page-title-main">Heating element</span> Device that converts electricity into heat

A heating element is a device used for conversion of electric energy into heat, consisting of a heating resistor and accessories. Heat is generated by the passage of electric current through a resistor through a process known as Joule Heating. Heating elements are used in household appliances, industrial equipment, and scientific instruments enabling them to perform tasks such as cooking, warming, or maintaining specific temperatures higher than the ambient.

<span class="mw-page-title-main">Shell-and-tube heat exchanger</span> Class of heat exchanger designs

A shell-and-tube heat exchanger is a class of heat exchanger designs. It is the most common type of heat exchanger in oil refineries and other large chemical processes, and is suited for higher-pressure applications. As its name implies, this type of heat exchanger consists of a shell with a bundle of tubes inside it. One fluid runs through the tubes, and another fluid flows over the tubes to transfer heat between the two fluids. The set of tubes is called a tube bundle, and may be composed of several types of tubes: plain, longitudinally finned, etc.

<span class="mw-page-title-main">Thermal power station</span> Power plant that generates electricity from heat energy

A thermal power station is a type of power station in which heat energy is converted to electrical energy. In a steam-generating cycle heat is used to boil water in a large pressure vessel to produce high-pressure steam, which drives a steam turbine connected to an electrical generator. The low-pressure exhaust from the turbine enters a steam condenser where it is cooled to produce hot condensate which is recycled to the heating process to generate more high pressure steam. This is known as a Rankine cycle.

<span class="mw-page-title-main">Surface condenser</span> Steam engine component

A surface condenser is a water-cooled shell and tube heat exchanger installed to condense exhaust steam from a steam turbine in thermal power stations. These condensers are heat exchangers which convert steam from its gaseous to its liquid state at a pressure below atmospheric pressure. Where cooling water is in short supply, an air-cooled condenser is often used. An air-cooled condenser is however, significantly more expensive and cannot achieve as low a steam turbine exhaust pressure as a water-cooled surface condenser.

<span class="mw-page-title-main">Ground-coupled heat exchanger</span> Underground heat exchanger loop that can capture or dissipate heat to or from the ground

A ground-coupled heat exchanger is an underground heat exchanger that can capture heat from and/or dissipate heat to the ground. They use the Earth's near constant subterranean temperature to warm or cool air or other fluids for residential, agricultural or industrial uses. If building air is blown through the heat exchanger for heat recovery ventilation, they are called earth tubes.

<span class="mw-page-title-main">Aluminium alloy</span> Alloy in which aluminium is the predominant metal

An aluminium alloy (UK/IUPAC) or aluminum alloy is an alloy in which aluminium (Al) is the predominant metal. The typical alloying elements are copper, magnesium, manganese, silicon, tin, nickel and zinc. There are two principal classifications, namely casting alloys and wrought alloys, both of which are further subdivided into the categories heat-treatable and non-heat-treatable. About 85% of aluminium is used for wrought products, for example rolled plate, foils and extrusions. Cast aluminium alloys yield cost-effective products due to the low melting point, although they generally have lower tensile strengths than wrought alloys. The most important cast aluminium alloy system is Al–Si, where the high levels of silicon (4–13%) contribute to give good casting characteristics. Aluminium alloys are widely used in engineering structures and components where light weight or corrosion resistance is required.

<span class="mw-page-title-main">Direct exchange geothermal heat pump</span>

A direct exchange (DX) geothermal heat pump is a type of ground source heat pump in which refrigerant circulates through copper tubing placed in the ground unlike other ground source heat pumps where refrigerant is restricted to the heat pump itself with a secondary loop in the ground filled with a mixture of water and anti-freeze.

CuproBraze is a copper-alloy heat exchanger technology for high-temperature and pressure environments such as those in modern diesel engines. The technology, developed by the International Copper Association (ICA), is licensed for free to heat exchanger manufacturers around the world.

Internally grooved copper tubes, also known as "microfin tubes", are a small diameter coil technology for modern air conditioning and refrigeration systems. Grooved coils facilitate more efficient heat transfer than smooth coils. Small diameter coils have better rates of heat transfer than conventionally-sized condenser and evaporator coils with round copper tubes and aluminum or copper fin that have been the standard in the HVAC industry for many years. Small diameter coils can withstand the higher pressures required by the new generation of environmentally friendlier refrigerants. They have lower material costs because they require less refrigerant, fin, and coil materials. They enable the design of smaller and lighter high-efficiency air conditioners and refrigerators because the evaporator and condenser coils are smaller and lighter.

<span class="mw-page-title-main">Copper in renewable energy</span> The use of copper in renewable energy

Renewable energy sources such as solar, wind, tidal, hydro, biomass, and geothermal have become significant sectors of the energy market. The rapid growth of these sources in the 21st century has been prompted by increasing costs of fossil fuels as well as their environmental impact issues that significantly lowered their use.

Steam and water analysis system (SWAS) is a system dedicated to the analysis of steam or water. In power stations, it is usually used to analyze boiler steam and water to ensure the water used to generate electricity is clean from impurities which can cause corrosion to any metallic surface, such as in boiler and turbine.

References

  1. "Introduction". Copper properties and uses. SchoolscIence.co.uk. Archived from the original on 22 November 2019. Retrieved 26 November 2012.
  2. 1 2 Gaffoglio, Carl J., Copper alloy surface condenser tube application and service considerations; CDA Heat Exchange Seminars; Copper Development Association
  3. 1 2 "Coils" (PDF). Super Radiator Coils. Archived from the original (PDF) on 26 May 2020. Retrieved 15 March 2019.
  4. 10 tips on getting the most from your coil; Super Radiator Coils; http://www.srcoils.com/wp-content/blogs.dir/1/files/2010/05/T003-10-Tips.pdf%5B%5D
  5. Chung, DDL (2001). "Materials for thermal conduction" (PDF). Applied Thermal Engineering. 21 (16): 1593–1605. doi:10.1016/s1359-4311(01)00042-4.
  6. "Thermal Properties of Metals, Conductivity, Thermal Expansion, Specific Heat". Engineer's Edge.
  7. "Thermal conductivity of selected metals" (PDF). National Standard Reference Data System (NSRDS). US Department of Commerce. 25 November 1966. Archived from the original (PDF) on 24 September 2008.
  8. 1 2 Finned coil heat exchangers (water to air heat exchangers); Brazetek; http://www.brazetek.com/water-to-air-heat-exchangers
  9. T.E. Larson, Corrosion by domestic waters; ISWS-75 Bulletin 59; State of Illinois Department of Registration and Education; Page 29.
  10. D.N. Fultonberg; Corrosion of aluminum in water; Westinghouse Electric Corp. Contract NAS 3-5215, prepared for the Lewis Research Center, U.S. National Aeronautics and Space Administration; Page 3.
  11. 1 2 Kobelco: Copper alloy tubes for heat-exchanger; Shinko Metal Products, Japan; http://www.shinkometal.co.jp/catalog/copperalloy-en-sc.pdf Archived 29 October 2013 at the Wayback Machine
  12. Powell, C.A.; Preventing biofouling with copper-nickel; Copper Development Association, October 2002; "Archived copy" (PDF). Archived from the original (PDF) on 30 October 2012. Retrieved 26 November 2012.{{cite web}}: CS1 maint: archived copy as title (link)
  13. Sutherland, I.W., 1983, Microbial exopolysaccarides: Their role in microbial adhesion in aqueous systems, Critical Reviews in Microbiology, Vol. 10, pp.173–201
  14. Edding, Mario E., Flores, Hector, and Miranda, Claudio, (1995), Experimental Usage of Copper-Nickel Alloy Mesh in Mariculture. Part 1: Feasibility of usage in a temperate zone; Part 2: Demonstration of usage in a cold zone; Final report to the International Copper Association Ltd.
  15. Michels, H. (2011). Copper air quality program. Annual Report #4, prepared for U.S. Army Medical Research and Materiel Command, Financial Times. Detrick, Maryland.
  16. Schmidt, Michael G.; Attaway, Hubert H.; Terzieva, Silva; Marshall, Anna; Steed, Lisa L.; Salzberg, Deborah; Hamoodi, Hameed A.; Khan, Jamil A.; Feigley, Charles E.; Michels, Harold. T. (2012). "Characterization and Control of the Microbial Community Affiliated with Copper or Aluminum Heat Exchangers of HVAC Systems". Current Microbiology. 65 (2): 141–9. doi:10.1007/s00284-012-0137-0. PMC   3378845 . PMID   22569892.
  17. 1 2 Copper Helps Shanghai Bus Users Breathe Easy: http://www.microgroove.net/press/copper-helps-shanghai-bus-users-breathe-easy
  18. Jiangping, C. (2011). Year 2011 Research Report for the Comparative Analysis of Antimicrobial Capability for Copper and Aluminum Fin Radiators in Air Conditioners of Public Buses, Shanghai Municipal Center for Disease Control and Prevention, Environmental Health Section, International Copper Association.
  19. Michel, J. 2012. Your new weapon in the fight against hospital-acquired infections; Antimicrobial copper webinar presented by Modern Healthcare, 12 September 2012; Webinar ID: 883-480-666.
  20. Feigley, C. 2011. Copper heat exchangers for improving indoor ait quality: Cooling season at Ft. Jackson. Paper #919, Proceedings of Indoor Air 2011. 12th International Conference on Indoor Air Quality and Climate; Austin, Texas, USA, June 2011
  21. Weaver, L.; Michels, H.T.; Keevil, C.W. (2010). "Potential for preventing spread of fungi in air-conditioning systems constructed using copper instead of aluminium". Letters in Applied Microbiology. 50 (1): 18–23. doi:10.1111/j.1472-765X.2009.02753.x. PMID   19943884. S2CID   3912272.
  22. Condenser and heat exchanger systems; CDA; W. Kirk, LaQue Center for Corrosion Technology; Authur Tuthill, Consultant to Nickel Development Institute; http://www.copper.org/applications/cuni/txt_condenser_heat_exch_syst.html Archived 27 November 2012 at the Wayback Machine
  23. B. Todd (1986). Nickel-Containing Materials in Marine and Related Environments. 25th Conference of Metallurgists, Toronto, August 1986
  24. 1 2 Heat Exchangers and Piping Systems from Copper Alloys – Commissioning, Operating and Shutdown, Manfred Jasner, Meinhard Hecht, Wolfgang Beckmann, KME; http://www.copper.org/applications/cuni/txt_kme.html Archived 20 October 2012 at the Wayback Machine
  25. Industrial Shell-and-tube heat exchangers; American Industrial Heat Transfer Inc.; http://www.aihti.com/pdf/fbf.pdf
  26. Heat Exchangers and Piping Systems from Copper Alloys – Commissioning, Operating and Shutdown; http://www.copper.org/applications/cuni/txt_kme.html#1 Archived 20 October 2012 at the Wayback Machine
  27. W. Kirk, Condenser and heat exchanger systems; CDA; LaQue Center for Corrosion Technology; Authur Tuthill, Consultant to Nickel Development Institute; http://www.copper.org/applications/cuni/txt_condenser_heat_exch_syst.html Archived 27 November 2012 at the Wayback Machine
  28. P.T. Gilbert, "A Review of Recent Work on Corrosion Behavior of Copper Alloys in Seawater," Materials Performance, Vol.21, Feb. 1982, pp.47–53
  29. P.T. Gilbert, "Selection of Materials for Heat Exchangers," 6th International Congress on Metallic Corrosion, Sydney, Australia, December 1975.
  30. A.H. Tuthill, "The Right Metal for Heat Exchanger Tubes," Chemical Engineering, Vol.97, January 1990, pp.120–124.
  31. 2011 global status report by Renewable Energy Policy Network for the 21st Century (REN21)); "REN21 - Renewables Global Status Report". Archived from the original on 3 November 2012. Retrieved 26 November 2012.
  32. Solar water heaters; Energy Savers; Energy Efficiency and Renewable Energy; U.S. Department of Energy; http://www.energysavers.gov/your_home/water_heating/index.cfm/mytopic=12850/ Archived 25 August 2012 at the Wayback Machine
  33. Solar hot water; B&R Service Inc.; http://www.bandrservice.com/solar.htm
  34. How solar hot water system works; SolarPlusGreen.com; http://www.solarplusgreen.com/solar-know-how.htm Archived 4 September 2012 at the Wayback Machine
  35. Mirasol Solar Energy Systems; http://www.mirasolenergysystems.com/pdf/et-technology.pdf Archived 4 November 2013 at the Wayback Machine
  36. How solar heaters work; Mayca Solar Energy; "Technical Info, Haining Mayca Solar Energy Technology Co., Ltd". Archived from the original on 28 October 2012. Retrieved 26 November 2012.
  37. Bayat Energy: solar water heaters; http://www.bayatenergy.co.uk/Solar%20Water%20Heaters%20Catalogue.pdf Archived 3 November 2013 at the Wayback Machine
  38. Antimicrobial Copper; http://www.antimicrobialcopper.com Archived 17 October 2012 at the Wayback Machine
  39. Applications: Air Conditioning and Refrigeration; Copper Development Association; http://www.copper.org/applications/plumbing/apps/acr.html
  40. US EPA registers antimicrobial copper for HVAC applications; Antimicrobial Copper; http://www.antimicrobialcopper.com/us/news-center/news/us-epa-registers-antimicrobial-copper-for-hvac-applications.aspx
  41. Buildings.com; Copper for HVAC Efficiency; http://www.buildings.com/tabid/3334/ArticleID/11545/Default.aspx
  42. Corrosion Control-Cooling Systems | GE Water
  43. Gas water heaters with improved heat exchangers; http://copperalliance.org/core-initiatives/technology/technology-projects/
  44. Gas Combustion Equipment; http://copperalliance.org/wordpress/wp-content/uploads/downloads/2012/06/technology_roadmap-en.pdf%5B%5D
  45. Copper DX geothermal heat pump; Copper Development Association; http://www.copper.org/applications/plumbing/heatpump/dxhp_main.html
  46. Thermal Solutions Intl., Copper heatsinks; http://www.thermal-solutions.us/copper-heatsinks.html
  47. Cooliance; Copper heat sinks; "Copper Heatsinks". Archived from the original on 11 October 2014. Retrieved 10 February 2015.
  48. Electronics Cooling Methods in Industry; Heat Pipes in Electronics; http://www.pathways.cu.edu.eg/ec/Text-PDF/Part%20C-15.pdf
  49. Electronics cooling: Heat pipes for electronics cooling applications; 1 September 1996; http://www.electronics-cooling.com/1996/09/heat-pipes-for-electronics-cooling-applications
  50. Bilen, Kadir; Cetin, Murat; Gul, Hasan; Balta, Tuba (2009). "The investigation of groove geometry effect on heat transfer for internally grooved tubes". Applied Thermal Engineering. 29 (4): 753–61. doi:10.1016/j.applthermaleng.2008.04.008.
  51. Aroonrat, K.; Jumpholkul, C.; Leelaprachakul, R.; Dalkilic, A.S.; Mahian, O.; Wongwises, S. (2013). "Heat transfer and single-phase flow in internally grooved tubes". International Communications in Heat and Mass Transfer. 42: 62–8. doi:10.1016/j.icheatmasstransfer.2012.12.001.
  52. FAQs: Thirty Questions with Answers about Economical, Eco-friendly Copper Tubes for Air Conditioner Applications; http://www.microgroove.net/sites/default/files/overview-ica-questions-and-answers-qa30.pdf
  53. Microgroove Brochure: http://www.microgroove.net/sites/default/files/microgroove-brochure-game-changer.pdf
  54. Microgroove™ Update Newsletter: Volume 1, Issue 2, August 2011: http://www.microgroove.net/sites/default/files/4315_microgroove_newsletter_august_2.pdf
  55. "How Copper printing can solve complex problems". 19 October 2022.