Fanno flow

Last updated

Fanno flow is the adiabatic flow through a constant area duct where the effect of friction is considered. [1] Compressibility effects often come into consideration, although the Fanno flow model certainly also applies to incompressible flow. For this model, the duct area remains constant, the flow is assumed to be steady and one-dimensional, and no mass is added within the duct. The Fanno flow model is considered an irreversible process due to viscous effects. The viscous friction causes the flow properties to change along the duct. The frictional effect is modeled as a shear stress at the wall acting on the fluid with uniform properties over any cross section of the duct.

Contents

For a flow with an upstream Mach number greater than 1.0 in a sufficiently long duct, deceleration occurs and the flow can become choked. On the other hand, for a flow with an upstream Mach number less than 1.0, acceleration occurs and the flow can become choked in a sufficiently long duct. It can be shown that for flow of calorically perfect gas the maximum entropy occurs at M  = 1.0. Fanno flow is named after Gino Girolamo Fanno.

Theory

Figure 1 A Fanno Line is plotted on the dimensionless H-DS axis. Fanno1.PNG
Figure 1 A Fanno Line is plotted on the dimensionless H-ΔS axis.

The Fanno flow model begins with a differential equation that relates the change in Mach number with respect to the length of the duct, dM/dx. Other terms in the differential equation are the heat capacity ratio, γ, the Fanning friction factor, f, and the hydraulic diameter, Dh:

Assuming the Fanning friction factor is a constant along the duct wall, the differential equation can be solved easily. [2] [3] One must keep in mind, however, that the value of the Fanning friction factor can be difficult to determine for supersonic and especially hypersonic flow velocities. The resulting relation is shown below where L* is the required duct length to choke the flow assuming the upstream Mach number is supersonic. The left-hand side is often called the Fanno parameter.

Equally important to the Fanno flow model is the dimensionless ratio of the change in entropy over the heat capacity at constant pressure, cp.

The above equation can be rewritten in terms of a static to stagnation temperature ratio, which, for a calorically perfect gas, is equal to the dimensionless enthalpy ratio, H:

The equation above can be used to plot the Fanno line, which represents a locus of states for given Fanno flow conditions on an H-ΔS diagram. In the diagram, the Fanno line reaches maximum entropy at H = 0.833 and the flow is choked. According to the Second law of thermodynamics, entropy must always increase for Fanno flow. This means that a subsonic flow entering a duct with friction will have an increase in its Mach number until the flow is choked. Conversely, the Mach number of a supersonic flow will decrease until the flow is choked. Each point on the Fanno line corresponds with a different Mach number, and the movement to choked flow is shown in the diagram.

The Fanno line defines the possible states for a gas when the mass flow rate and total enthalpy are held constant, but the momentum varies. Each point on the Fanno line will have a different momentum value, and the change in momentum is attributable to the effects of friction. [4]

Additional Fanno flow relations

Figure 2 Common thermodynamic property ratios plotted as a function of Mach number using the Fanno flow model. Fanno Properties.PNG
Figure 2 Common thermodynamic property ratios plotted as a function of Mach number using the Fanno flow model.

As was stated earlier, the area and mass flow rate in the duct are held constant for Fanno flow. Additionally, the stagnation temperature remains constant. These relations are shown below with the * symbol representing the throat location where choking can occur. A stagnation property contains a 0 subscript.

Differential equations can also be developed and solved to describe Fanno flow property ratios with respect to the values at the choking location. The ratios for the pressure, density, temperature, velocity and stagnation pressure are shown below, respectively. They are represented graphically along with the Fanno parameter.

Applications

Figure 3 A supersonic nozzle leading into a constant area duct is depicted. The initial conditions exist at point 1. Point 2 exists at the nozzle throat, where M = 1. Point 3 labels the transition from isentropic to Fanno flow. Points 4 and 5 give the pre- and post-shock wave conditions, and point E is the exit from the duct. Fanno flow through a nozzle.png
Figure 3 A supersonic nozzle leading into a constant area duct is depicted. The initial conditions exist at point 1. Point 2 exists at the nozzle throat, where M = 1. Point 3 labels the transition from isentropic to Fanno flow. Points 4 and 5 give the pre- and post-shock wave conditions, and point E is the exit from the duct.
Figure 4 The H-S diagram is depicted for the conditions of Figure 3. Entropy is constant for isentropic flow, so the conditions at point 1 move down vertically to point 3. Next, the flow follows the Fanno line until a shock changes the flow from supersonic to subsonic. The flow then follows the Fanno line again, almost reaching a choked condition before exiting the duct. H-S graph of a Fanno flow.png
Figure 4 The H-S diagram is depicted for the conditions of Figure 3. Entropy is constant for isentropic flow, so the conditions at point 1 move down vertically to point 3. Next, the flow follows the Fanno line until a shock changes the flow from supersonic to subsonic. The flow then follows the Fanno line again, almost reaching a choked condition before exiting the duct.
Figure 5 Fanno and Rayleigh Line Intersection Chart. Fanno-Rayleigh confrontation graph.png
Figure 5 Fanno and Rayleigh Line Intersection Chart.

The Fanno flow model is often used in the design and analysis of nozzles. In a nozzle, the converging or diverging area is modeled with isentropic flow, while the constant area section afterwards is modeled with Fanno flow. For given upstream conditions at point 1 as shown in Figures 3 and 4, calculations can be made to determine the nozzle exit Mach number and the location of a normal shock in the constant area duct. Point 2 labels the nozzle throat, where M = 1 if the flow is choked. Point 3 labels the end of the nozzle where the flow transitions from isentropic to Fanno. With a high enough initial pressure, supersonic flow can be maintained through the constant area duct, similar to the desired performance of a blowdown-type supersonic wind tunnel. However, these figures show the shock wave before it has moved entirely through the duct. If a shock wave is present, the flow transitions from the supersonic portion of the Fanno line to the subsonic portion before continuing towards M = 1. The movement in Figure 4 is always from the left to the right in order to satisfy the second law of thermodynamics.

The Fanno flow model is also used extensively with the Rayleigh flow model. These two models intersect at points on the enthalpy-entropy and Mach number-entropy diagrams, which is meaningful for many applications. However, the entropy values for each model are not equal at the sonic state. The change in entropy is 0 at M = 1 for each model, but the previous statement means the change in entropy from the same arbitrary point to the sonic point is different for the Fanno and Rayleigh flow models. If initial values of si and Mi are defined, a new equation for dimensionless entropy versus Mach number can be defined for each model. These equations are shown below for Fanno and Rayleigh flow, respectively.

Figure 5 shows the Fanno and Rayleigh lines intersecting with each other for initial conditions of si = 0 and Mi = 3. The intersection points are calculated by equating the new dimensionless entropy equations with each other, resulting in the relation below.

The intersection points occur at the given initial Mach number and its post-normal shock value. For Figure 5, these values are M = 3 and 0.4752, which can be found the normal shock tables listed in most compressible flow textbooks. A given flow with a constant duct area can switch between the Fanno and Rayleigh models at these points.

See also

Related Research Articles

<span class="mw-page-title-main">Mach number</span> Ratio of speed of an object moving through fluid and local speed of sound

The Mach number, often only Mach, is a dimensionless quantity in fluid dynamics representing the ratio of flow velocity past a boundary to the local speed of sound. It is named after the Czech physicist and philosopher Ernst Mach.

<span class="mw-page-title-main">Potential flow</span> Velocity field as the gradient of a scalar function

In fluid dynamics, potential flow or irrotational flow refers to a description of a fluid flow with no vorticity in it. Such a description typically arises in the limit of vanishing viscosity, i.e., for an inviscid fluid and with no vorticity present in the flow.

<span class="mw-page-title-main">Ideal gas</span> Mathematical model which approximates the behavior of real gases

An ideal gas is a theoretical gas composed of many randomly moving point particles that are not subject to interparticle interactions. The ideal gas concept is useful because it obeys the ideal gas law, a simplified equation of state, and is amenable to analysis under statistical mechanics. The requirement of zero interaction can often be relaxed if, for example, the interaction is perfectly elastic or regarded as point-like collisions.

In electrochemistry, the Nernst equation is a chemical thermodynamical relationship that permits the calculation of the reduction potential of a reaction from the standard electrode potential, absolute temperature, the number of electrons involved in the redox reaction, and activities of the chemical species undergoing reduction and oxidation respectively. It was named after Walther Nernst, a German physical chemist who formulated the equation.

<span class="mw-page-title-main">Weibull distribution</span> Continuous probability distribution

In probability theory and statistics, the Weibull distribution is a continuous probability distribution. It models a broad range of random variables, largely in the nature of a time to failure or time between events. Examples are maximum one-day rainfalls and the time a user spends on a web page.

Compressible flow is the branch of fluid mechanics that deals with flows having significant changes in fluid density. While all flows are compressible, flows are usually treated as being incompressible when the Mach number is smaller than 0.3. The study of compressible flow is relevant to high-speed aircraft, jet engines, rocket motors, high-speed entry into a planetary atmosphere, gas pipelines, commercial applications such as abrasive blasting, and many other fields.

<span class="mw-page-title-main">Isentropic process</span> Thermodynamic process that is reversible and adiabatic

An isentropic process is an idealized thermodynamic process that is both adiabatic and reversible. The work transfers of the system are frictionless, and there is no net transfer of heat or matter. Such an idealized process is useful in engineering as a model of and basis of comparison for real processes. This process is idealized because reversible processes do not occur in reality; thinking of a process as both adiabatic and reversible would show that the initial and final entropies are the same, thus, the reason it is called isentropic. Thermodynamic processes are named based on the effect they would have on the system. Even though in reality it is not necessarily possible to carry out an isentropic process, some may be approximated as such.

<span class="mw-page-title-main">Rankine–Hugoniot conditions</span> Concept in physics

The Rankine–Hugoniot conditions, also referred to as Rankine–Hugoniot jump conditions or Rankine–Hugoniot relations, describe the relationship between the states on both sides of a shock wave or a combustion wave in a one-dimensional flow in fluids or a one-dimensional deformation in solids. They are named in recognition of the work carried out by Scottish engineer and physicist William John Macquorn Rankine and French engineer Pierre Henri Hugoniot.

de Laval nozzle Pinched tube generating supersonic flow

A de Laval nozzle is a tube which is pinched in the middle, making a carefully balanced, asymmetric hourglass shape. It is used to accelerate a compressible fluid to supersonic speeds in the axial (thrust) direction, by converting the thermal energy of the flow into kinetic energy. De Laval nozzles are widely used in some types of steam turbines and rocket engine nozzles. It also sees use in supersonic jet engines.

<span class="mw-page-title-main">Heat capacity ratio</span> Thermodynamic quantity

In thermal physics and thermodynamics, the heat capacity ratio, also known as the adiabatic index, the ratio of specific heats, or Laplace's coefficient, is the ratio of the heat capacity at constant pressure to heat capacity at constant volume. It is sometimes also known as the isentropic expansion factor and is denoted by γ (gamma) for an ideal gas or κ (kappa), the isentropic exponent for a real gas. The symbol γ is used by aerospace and chemical engineers.

The principle of detailed balance can be used in kinetic systems which are decomposed into elementary processes. It states that at equilibrium, each elementary process is in equilibrium with its reverse process.

Rayleigh flow refers to frictionless, non-adiabatic flow through a constant area duct where the effect of heat addition or rejection is considered. Compressibility effects often come into consideration, although the Rayleigh flow model certainly also applies to incompressible flow. For this model, the duct area remains constant and no mass is added within the duct. Therefore, unlike Fanno flow, the stagnation temperature is a variable. The heat addition causes a decrease in stagnation pressure, which is known as the Rayleigh effect and is critical in the design of combustion systems. Heat addition will cause both supersonic and subsonic Mach numbers to approach Mach 1, resulting in choked flow. Conversely, heat rejection decreases a subsonic Mach number and increases a supersonic Mach number along the duct. It can be shown that for calorically perfect flows the maximum entropy occurs at M = 1. Rayleigh flow is named after John Strutt, 3rd Baron Rayleigh.

Choked flow is a compressible flow effect. The parameter that becomes "choked" or "limited" is the fluid velocity.

<span class="mw-page-title-main">Chapman–Jouguet condition</span>

The Chapman–Jouguet condition holds approximately in detonation waves in high explosives. It states that the detonation propagates at a velocity at which the reacting gases just reach sonic velocity as the reaction ceases.

<span class="mw-page-title-main">Prandtl–Meyer expansion fan</span> Phenomenon in fluid dynamics

A supersonic expansion fan, technically known as Prandtl–Meyer expansion fan, a two-dimensional simple wave, is a centered expansion process that occurs when a supersonic flow turns around a convex corner. The fan consists of an infinite number of Mach waves, diverging from a sharp corner. When a flow turns around a smooth and circular corner, these waves can be extended backwards to meet at a point.

Isentropic nozzle flow describes the movement of a gas or fluid through a narrowing opening without an increase or decrease in entropy.

Compressible Duct Flow with friction. This article concerns a gas flow with friction due to the boundary walls under consideration. This problem is same as the Moody type pipe-friction problem but with considerably larger changes in friction, kinetic energy and enthalpy of the flow.

In gas dynamics, the Kantrowitz limit refers to a theoretical concept describing choked flow at supersonic or near-supersonic velocities. When an initially subsonic fluid flow experiences a reduction in cross-section area, the flow speeds up in order to maintain the same mass-flow rate, per the continuity equation. If a near supersonic flow experiences an area contraction, the velocity of the flow will increase until it reaches the local speed of sound, and the flow will be choked. This is the principle behind the Kantrowitz limit: it is the maximum amount of contraction a flow can experience before the flow chokes, and the flow speed can no longer be increased above this limit, independent of changes in upstream or downstream pressure.

Mass injection flow refers to inviscid, adiabatic flow through a constant area duct where the effect of mass addition is considered. For this model, the duct area remains constant, the flow is assumed to be steady and one-dimensional, and mass is added within the duct. Because the flow is adiabatic, unlike in Rayleigh flow, the stagnation temperature is a constant. Compressibility effects often come into consideration, though this flow model also applies to incompressible flow.

References

  1. Shapiro, A.H., The Dynamics and Thermodynamics of Compressible Fluid Flow, Volume 1, Ronald Press, 1953.
  2. Zucker, R.D., Biblarz, O., Fundamentals of Gas Dynamics, John Wiley & Sons, 2002.
  3. Hodge, B.K., and Koenig, K., Compressible Fluid Dynamics with Personal Computer Applications, Prentice Hall, 1995.
  4. The Phenomena of Fluid Motions, R. S. Brodkey, p187, R. S. Brodkey (pub), 1995