A steam generator (aka nuclear steam raising plant ('NSRP')) is a heat exchanger used to convert water into steam from heat produced in a nuclear reactor core. It is used in pressurized water reactors (PWRs), between the primary and secondary coolant loops. It is also used in liquid metal cooled reactors (LMRs), pressurized heavy-water reactors (PHWRs), and gas-cooled reactors (GCRs).

Contents

In typical PWR designs, the primary coolant is high-purity water, kept under high pressure so it cannot boil. This primary coolant is pumped through the reactor core where it absorbs heat from the fuel rods. It then passes through the steam generator, where it transfers its heat (via conduction through metal) to lower-pressure water which is allowed to boil.

Purpose

Unlike PWRs, boiling water reactors (BWRs) do not use steam generators. The primary coolant is allowed to boil directly in the reactor core, and the steam is simply passed through a steam turbine. While theoretically simple, this has a downside for maintenance. While passing through the core, primary coolant water is subjected to high neutron flux. This activates oxygen and dissolved nitrogen in the water. The major reaction [1] is: an atom of oxygen-16 absorbs 1 neutron and emits 1 proton, becoming nitrogen-16. Nitrogen-16 has a 7-second half-life and produces a gamma ray when it decays back to oxygen-16. The 7-second half-life is long enough for the water to circulate out of the reactor. In a BWR, this means that the water may be in the steam turbine when it releases its gamma rays. Although no long-lived radioisotopes are produced by this reaction, the gamma radiation means that humans cannot be present in a BWR's turbine hall during reactor operation and for a short time afterwards.

By contrast, in a PWR, the steam generator separates the activated primary coolant water from the secondary coolant which passes through the steam turbine. Thus, humans can freely access a PWR's turbines and other steam plant components during operation. This reduces maintenance cost and improves up-time.

Description

Vertical recirculating-type steam generator (typical of Westinghouse and Combustion Engineering-designed reactors) and components. Generic Nuclear PWR Steam Generator.svg
Vertical recirculating-type steam generator (typical of Westinghouse and Combustion Engineering-designed reactors) and components.

In commercial power plants, there are two to four steam generators per reactor; each steam generator can measure up to 70 feet (21 m) in height and weigh as much as 800 tons. Each steam generator can contain anywhere from 3,000 to 16,000 tubes, each about .75 inches (19 mm) in diameter. The coolant (treated water), which is maintained at high pressure to prevent boiling, is pumped through the nuclear reactor core. Heat transfer takes place between the reactor core and the circulating water and the coolant is then pumped through the primary tube side of the steam generator by coolant pumps before returning to the reactor core. This is referred to as the primary loop.

That water flowing through the steam generator boils water on the shell side (which is kept at a lower pressure than the primary side) to produce steam. This is referred to as the secondary loop. The secondary-side steam is delivered to the turbines to make electricity. The steam is subsequently condensed via cooled water from a tertiary loop and returned to the steam generator to be heated once again. The tertiary cooling water may be recirculated to cooling towers where it sheds waste heat before returning to condense more steam. Once-through tertiary cooling may otherwise be provided by a river, lake, or ocean. This primary, secondary, tertiary cooling scheme is the basis of the pressurized water reactor, which is the most common nuclear power plant design worldwide.

In other types of reactors, such as the pressurised heavy water reactors of the CANDU design, the primary fluid is heavy water. Liquid metal cooled reactors such as the Russian BN-600 reactor use a liquid metal, such as sodium, as the primary coolant. These also use heat exchangers between primary metal coolant and the secondary water coolant, and thus their secondary and tertiary cooling is similar to a PWR.

A steam generator's heat-exchange tubes have an important safety role, because they separate radioactive and non-radioactive fluid systems. (The primary coolant becomes briefly radioactive from its exposure to the core, and also has trace amounts of longer-lived radioactive isotopes dissolved in it, such as dissolved atoms of iron from pipes.) Because the primary coolant is at higher pressure, a ruptured heat-exchange tube would cause primary coolant to leak into the secondary loop. Typically this would require the plant to shutdown for repair. To avoid such primary-secondary leaks, steam generator tubes are periodically inspected by eddy-current testing, and individual tubes can be plugged to remove them from operation. [2] As with many nuclear components, mechanical engineers determine the inspection frequency using the known rates of corrosion and crack propagation in the material. If an inspection finds that a tube wall is thin enough that it might corrode through before the next scheduled inspection, the tube is plugged. (Plugging a tube is typically easier than attempting to repair it. There are many small heat-exchange tubes, and steam generators are designed with excess tubes to allow some to be plugged.)

Entire steam generators are often replaced in plant mid-life, which is a major undertaking. Most U.S. PWR plants have had steam generators replaced. [2]

History

The nuclear powered steam generator started as a power plant for the first nuclear submarine, the USS Nautilus (SSN-571). It was designed and built by the Westinghouse Electric Company power company for the submarine; from there the company started its development and research of nuclear-powered steam generators. [3] Once peaceful nuclear reactors were legalized for use as power plants, power corporations jumped at the opportunity to utilize the growing development of nuclear powered steam generators. Westinghouse built one of the first nuclear power plants, the Yankee Rowe nuclear power station (NPS), which also used a nuclear powered steam generator, in 1960. This power plant had a one hundred MWe (mega watt electric) output. By comparison, some modern plants have over 1100 MWe output. Eventually, other international companies such as Babcock & Wilcox and Combustion Engineering began their own programs for research and development of the nuclear power steam generator.

Types

This Babcock & Wilcox nuclear steam generator moved in a special train (restricted to 20 mph) via the Penn Central Railroad and Southern Railway from Barberton, Ohio to a Duke Energy site in Oconee, S.C. This generator weights 1,140,000 lbs and is a record shipment for the Railroad at that time (1970). PCPOST BabcockWilcox Train.png
This Babcock & Wilcox nuclear steam generator moved in a special train (restricted to 20 mph) via the Penn Central Railroad and Southern Railway from Barberton, Ohio to a Duke Energy site in Oconee, S.C. This generator weights 1,140,000 lbs and is a record shipment for the Railroad at that time (1970).
A once-through steam generator Generic PWR OTSG.svg
A once-through steam generator
A VVER steam generator Generic WWER SG.svg
A VVER steam generator

Westinghouse and Combustion Engineering designs have vertical U-tubes with inverted tubes for the primary water. Canadian, Japanese, French, and German PWR suppliers use the vertical configuration as well. Russian VVER reactor designs use horizontal steam generators, which have the tubes mounted horizontally. Babcock & Wilcox plants (e.g., Three Mile Island) have smaller steam generators that force water through the top of the OTSGs (once-through steam generators; counter-flow to the feedwater) and out the bottom to be recirculated by the reactor coolant pumps. The horizontal design has proven to be less susceptible to degradation than the vertical U-tube design.[ citation needed ]

Materials and construction

The materials that make up the turbine and pipes of a nuclear powered steam generator are specially made and specifically designed to withstand the heat and radiation of the reactor. The water tubes also have to be able to resist corrosion from water for an extended period of time. The pipes that are used in American reactors are made of Inconel, either Alloy 600 or Alloy 690. Alloy 690 is made with extra chromium and most facilities heat treat the metal to make it better able to resist heat and corrosion. The high nickel content in Alloy 600 and Alloy 690 make them well suited for resisting acids and high degrees of stress and temperature.

Degradation

The annealed, or heat treated, Alloy 600 was prone to tube denting and thinning due to water chemistry. Plants that used the Alloy 600 in their water tubes therefore had to install new water chemistry controllers and change the chemicals they put in the water. Due to this, pipe thinning has been taken care of, but on rare occasions, tube denting still occurs, causing leaks and ruptures. The only way to prevent this is regular maintenance and check-ups, but this forces the reactor to shut down. In some cases, plants replaced their Alloy 600 tubes with Alloy 690 tubes and a few plants were shut down. To prevent future problems, manufacturers of steam turbines for nuclear power plants have improved their fabrication techniques and used other materials, such as stainless steel, to prevent tube denting. [4]

Typical operating conditions

Steam generators in a "typical" PWR in the USA have the following operating conditions:

SidePressure
(absolute)
Inlet
temperature
Outlet
temperature
Primary side (tube side)15.5 MPa
(2,250 psi)
315 °C
(599 °F)
(liquid water)
275 °C
(527 °F)
(liquid water)
Secondary side (shell side)6.2 MPa
(900 psi)
220 °C
(428 °F)
(liquid water)
275 °C
(527 °F)
(saturated steam)

Tube material

Various high-performance alloys and superalloys have been used for steam generator tubing, including type 316 stainless steel, Alloy 400, Alloy 600MA (mill annealed), Alloy 600TT (thermally treated), Alloy 690TT, and Alloy 800Mod.

See also

Related Research Articles

<span class="mw-page-title-main">Nuclear reactor</span> Device for controlled nuclear reactions

A nuclear reactor is a device used to initiate and control a fission nuclear chain reaction. Nuclear reactors are used at nuclear power plants for electricity generation and in nuclear marine propulsion. When a fissile nucleus like uranium-235 or plutonium-239 absorbs a neutron, it splits into lighter nuclei, releasing energy, gamma radiation, and free neutrons, which can induce further fission in a self-sustaining chain reaction. The process is carefully controlled using control rods and neutron moderators to regulate the number of neutrons that continue the reaction, ensuring the reactor operates safely. The efficiency of energy conversion in nuclear reactors is significantly higher compared to conventional fossil fuel plants; a kilo of uranium-235 can release millions of times more energy than a kilo of coal.

<span class="mw-page-title-main">Pressurized water reactor</span> Type of nuclear reactor

A pressurized water reactor (PWR) is a type of light-water nuclear reactor. PWRs constitute the large majority of the world's nuclear power plants. In a PWR, the primary coolant (water) is pumped under high pressure to the reactor core where it is heated by the energy released by the fission of atoms. The heated, high pressure water then flows to a steam generator, where it transfers its thermal energy to lower pressure water of a secondary system where steam is generated. The steam then drives turbines, which spin an electric generator. In contrast to a boiling water reactor (BWR), pressure in the primary coolant loop prevents the water from boiling within the reactor. All light-water reactors use ordinary water as both coolant and neutron moderator. Most use anywhere from two to four vertically mounted steam generators; VVER reactors use horizontal steam generators.

<span class="mw-page-title-main">Boiling water reactor</span> Type of nuclear reactor that directly boils water

A boiling water reactor (BWR) is a type of light water nuclear reactor used for the generation of electrical power. It is the second most common type of electricity-generating nuclear reactor after the pressurized water reactor (PWR), which is also a type of light water nuclear reactor.

<span class="mw-page-title-main">RBMK</span> Type of Soviet nuclear power reactor

The RBMK is a class of graphite-moderated nuclear power reactor designed and built by the Soviet Union. It is somewhat like a boiling water reactor as water boils in the pressure tubes. It is one of two power reactor types to enter serial production in the Soviet Union during the 1970s, the other being the VVER reactor. The name refers to its design where instead of a large steel pressure vessel surrounding the entire core, the core is surrounded by a cylindrical annular steel tank inside a concrete vault and each fuel assembly is enclosed in an individual 8 cm (inner) diameter pipe. The channels also contain the coolant, and are surrounded by graphite.

<span class="mw-page-title-main">Control rod</span> Device used to regulate the power of a nuclear reactor

Control rods are used in nuclear reactors to control the rate of fission of the nuclear fuel – uranium or plutonium. Their compositions include chemical elements such as boron, cadmium, silver, hafnium, or indium, that are capable of absorbing many neutrons without themselves decaying. These elements have different neutron capture cross sections for neutrons of various energies. Boiling water reactors (BWR), pressurized water reactors (PWR), and heavy-water reactors (HWR) operate with thermal neutrons, while breeder reactors operate with fast neutrons. Each reactor design can use different control rod materials based on the energy spectrum of its neutrons. Control rods have been used in nuclear aircraft engines like Project Pluto as a method of control.

<span class="mw-page-title-main">Light-water reactor</span> Type of nuclear reactor that uses normal water

The light-water reactor (LWR) is a type of thermal-neutron reactor that uses normal water, as opposed to heavy water, as both its coolant and neutron moderator; furthermore a solid form of fissile elements is used as fuel. Thermal-neutron reactors are the most common type of nuclear reactor, and light-water reactors are the most common type of thermal-neutron reactor.

Passive nuclear safety is a design approach for safety features, implemented in a nuclear reactor, that does not require any active intervention on the part of the operator or electrical/electronic feedback in order to bring the reactor to a safe shutdown state, in the event of a particular type of emergency. Such design features tend to rely on the engineering of components such that their predicted behaviour would slow down, rather than accelerate the deterioration of the reactor state; they typically take advantage of natural forces or phenomena such as gravity, buoyancy, pressure differences, conduction or natural heat convection to accomplish safety functions without requiring an active power source. Many older common reactor designs use passive safety systems to a limited extent, rather, relying on active safety systems such as diesel-powered motors. Some newer reactor designs feature more passive systems; the motivation being that they are highly reliable and reduce the cost associated with the installation and maintenance of systems that would otherwise require multiple trains of equipment and redundant safety class power supplies in order to achieve the same level of reliability. However, weak driving forces that power many passive safety features can pose significant challenges to effectiveness of a passive system, particularly in the short term following an accident.

Auxiliary feedwater is a backup water supply system found in pressurized water reactor nuclear power plants (PWRs). This system, sometimes known as emergency feedwater, can be used to cool the reactor, if normal feedwater to the steam generators fails to work. It works by pumping water to the steam generators from reserve tanks or a larger body of water to remove decay heat from the reactor by dumping non-radioactive steam to atmosphere or using this steam to drive turbine driven auxiliary feedwater pump(s). The auxiliary feedwater system in PWRs are often equipped with motor driven aux feedwater pumps, and, as an additional measure, turbine driven aux feedwater pump that is driven not by electricity but by steam generated by decay heat removal from the normal secondary side steam circuit of the plant. The typical steam turbine used in the aux feedwater systems are the “solid wheel” or “water wheel” Terry Steam Turbines manufactured by the Curtiss-Wright Corporation in Summerville, SC.

<span class="mw-page-title-main">Containment building</span> Structure surrounding a nuclear reactor to prevent radioactive releases

A containment building is a reinforced steel, concrete or lead structure enclosing a nuclear reactor. It is designed, in any emergency, to contain the escape of radioactive steam or gas to a maximum pressure in the range of 275 to 550 kPa. The containment is the fourth and final barrier to radioactive release, the first being the fuel ceramic itself, the second being the metal fuel cladding tubes, the third being the reactor vessel and coolant system.

<span class="mw-page-title-main">Supercritical water reactor</span> Concept nuclear reactor whose water operates at supercritical pressure

The supercritical water reactor (SCWR) is a concept Generation IV reactor, designed as a light water reactor (LWR) that operates at supercritical pressure. The term critical in this context refers to the critical point of water, and should not be confused with the concept of criticality of the nuclear reactor.

<span class="mw-page-title-main">VVER</span> Soviet / Russian nuclear reactor type

The water-water energetic reactor (WWER), or VVER is a series of pressurized water reactor designs originally developed in the Soviet Union, and now Russia, by OKB Gidropress. The idea of such a reactor was proposed at the Kurchatov Institute by Savely Moiseevich Feinberg. VVER were originally developed before the 1970s, and have been continually updated. They were one of the initial reactors developed by the USSR, the other being the infamous RBMK. As a result, the name VVER is associated with a wide variety of reactor designs spanning from generation I reactors to modern generation III+ reactor designs. Power output ranges from 70 to 1300 MWe, with designs of up to 1700 MWe in development. The first prototype VVER-210 was built at the Novovoronezh Nuclear Power Plant.

<span class="mw-page-title-main">BN-600 reactor</span> Russian sodium-cooled fast breeder reactor

The BN-600 reactor is a sodium-cooled fast breeder reactor, built at the Beloyarsk Nuclear Power Station, in Zarechny, Sverdlovsk Oblast, Russia. It has a 600 MWe gross capacity and a 560 MWe net capacity, provided to the Middle Urals power grid. It has been in operation since 1980 and represents an improvement to the preceding BN-350 reactor. In 2014, its larger sister reactor, the BN-800 reactor, began operation.

<span class="mw-page-title-main">Carolinas–Virginia Tube Reactor</span> Decommissioned experimental pressurized water reactor in South Carolina, US

Carolinas–Virginia Tube Reactor (CVTR), also known as Parr Nuclear Station, was an experimental pressurized tube heavy water nuclear power reactor at Parr, South Carolina in Fairfield County. It was built and operated by the Carolinas Virginia Nuclear Power Associates. CVTR was a small test reactor, capable of generating 17 megawatts of electricity. It was officially commissioned in December 1963 and left service in January 1967.

International Reactor Innovative and Secure (IRIS) is a Generation IV reactor design made by an international team of companies, laboratories, and universities and coordinated by Westinghouse. IRIS is hoped to open up new markets for nuclear power and make a bridge from Generation III reactor to Generation IV reactor technology. The design is not yet specific to reactor power output. Notably, a 335 MW output has been proposed, but it could be tweaked to be as low as a 100 MW unit.

The three primary objectives of nuclear reactor safety systems as defined by the U.S. Nuclear Regulatory Commission are to shut down the reactor, maintain it in a shutdown condition and prevent the release of radioactive material.

The B&W mPower was a proposed small modular reactor designed by Babcock & Wilcox, and to be built by Generation mPower LLC, a joint venture of Babcock & Wilcox and Bechtel. It was a Generation III+ integral pressurized water reactor concept.

A nuclear reactor coolant is a coolant in a nuclear reactor used to remove heat from the nuclear reactor core and transfer it to electrical generators and the environment. Frequently, a chain of two coolant loops are used because the primary coolant loop takes on short-term radioactivity from the reactor.

Boiling water reactor safety systems are nuclear safety systems constructed within boiling water reactors in order to prevent or mitigate environmental and health hazards in the event of accident or natural disaster.

<span class="mw-page-title-main">GE BWR</span> Type of commercial fission reactor

General Electric's BWR product line of boiling water reactors represents the designs of a relatively large (~18%) percentage of the commercial fission reactors around the world.

<span class="mw-page-title-main">Integral Molten Salt Reactor</span>

The integral molten salt reactor (IMSR) is a nuclear power plant design targeted at developing a commercial product for the small modular reactor (SMR) market. It employs molten salt reactor technology which is being developed by the Canadian company Terrestrial Energy.

References

  1. http://mafija.fmf.uni-lj.si/seminar/files/2015_2016/Andrej_Zohar_Activation.pdf [ bare URL PDF ]
  2. 1 2 "US steam generator replacement a winner". World Nuclear News. 30 January 2014. Retrieved 1 February 2014.
  3. Outline History of Nuclear Energy, World Nuclear Association (2014)
  4. Everything you want to know about Nuclear Power, University of Melbourne (2014) Nuclearinfo.net