Acton Lane Power Station | |
---|---|
Country | England, United Kingdom |
Location | London Borough of Ealing |
Coordinates | 51°31′50″N0°15′21″W / 51.5305°N 0.2559°W |
Status | Demolished |
Commission date | A 1899, B 1950 |
Decommission date | A 1964, B 1983 |
Owner(s) | As operator |
Operator(s) | METESCo (1899–1925) LPC (1925–1948) British Electricity Authority (1948–1955) Central Electricity Authority (1955–1957) Central Electricity Generating Board (1958–1983) |
Thermal power station | |
Primary fuel | Coal |
Cooling towers | 3 (concrete) |
Cooling source | Recirculating water |
Power generation | |
Units operational | A: 1 × 30 MW, B: 5 × 30 MW |
Units decommissioned | All |
Nameplate capacity | 150 MW |
Annual net output | See graph in text |
Acton Lane Power Station was a power station in London NW10. The station, also known as Willesden power station, was located to the south of the Euston to Birmingham railway on a site bounded by Acton Lane, the Grand Union Canal and the Dudding Hill railway line. In later years the site was extended to the south side of the canal. The entire site is now occupied by Willesden Grid Supply Point buildings. [1]
The first 'A' station was built by the Metropolitan Electric Supply Company Limited (METESCo) and commissioned in 1899. It was originally called Willesden power station but was later known as Acton Lane to distinguish it from another station called Willesden power station at Taylors Lane. METESCo supplied electricity to Finsbury, Holborn, Paddington, the City of Westminster, Acton, Greenford, Hanwell, Southall and Brentford.
The commissioning of the 'A' station enabled smaller less efficient power stations in central London to be closed or reconfigured as distribution substations. These included Manchester Square, Sardinia Street, Amberley Road (see below), Rathbone Place and Whitehall Court. [2]
In 1903 METESCo experimented with pulverised fuel firing of some of its boilers. Coal was pulverised to a fine powder in ball mills. The advantage was intimate mixing of powdered coal and air giving better combustion and higher boiler efficiencies. [3]
The station was taken over by the London Power Company Limited in 1925. It was one of four stations (the others being Bow, Deptford East and Grove Road Saint John's Wood) which continued following the formation of the London and Home Counties Joint Electricity Authority in 1925, which resulted in closure of many smaller stations in central London. [4]
The later Acton Lane 'B' station had three concrete cooling towers and dominated the eastern end of North Acton trading estate at Park Royal. Work on this began in 1950, initially for 56 MW. [5] Coal was supplied by rail to sidings from the adjacent railway to the north. Other power stations nearby included Neasden (since demolished), Taylors Lane and Stonebridge Park (demolished).
In 1967 there were complaints from boaters that ash from Acton Lane power station was silting up the Grand Union canal. The CEGB denied they were depositing ash into the canal and said that ash was taken away by lorry. It did admit that ash from another power station was deposited into the canal from another station but that this had been closed in 1958. [6]
The station closed on 31 October 1983 with a generating capacity of 150 MW. [7]
The 'A' station had a high pressure (HP) plant and a low pressure (LP) plant. The HP plant had an installed capacity of 30 MW comprising a single 30 MW machine.
In 1923 the generating plant at the 'A' station comprised 2 × 1,500 kW and 2 × 3,000 kW reciprocating machines and 1 × 3,000 kW, 2 × 4,000 kW and 2 × 10,000 kW steam turbines, a total generating capacity of 40 MW. [8] The boilers had a maximum capacity of 584,000 lb/hr (73.6 kg/s) of steam. The station had a total of 49,856 connections and a maximum load of 20,442 MW, supplied through a range of current and voltages: [8]
In 1923 the station generated 38.69 GWh, and sold 29.62 GWh, providing an income of £271,812. [8]
In 1954 the station generated 112.862 GWh. [9] The HP boilers had an output capacity of 440,000 lb/h, and in 1954 burned 71,700 tons of coal. The LP plant had an installed capacity of 127.9 MW. In 1954 it generated 130.34 GWh. The LP boilers had an output capacity of 1,400,000 lb/h and in 1954 burned 133,300 tons of coal. [9] The thermal efficiency of the LP plant was 14.24 per cent, compared to 22.91 per cent for the HP plant. [9] The LP side was decommissioned in the late 1950s.
The electricity output from Acton Lane A power station was: [10] [11] [12]
Year | LP station output GWh | HP station output GWh |
---|---|---|
1946 | 226.47 | |
1953/4 | 143.97 | 117.01 |
1954/5 | 151.09 | 110.26 |
1955/6 | 107.83 | 103.41 |
1956/7 | 84.72 | 109.68 |
1957/8 | 38.32 | 77.691 |
1960/1 | 5.18 | |
1961/2 | 6.00 | |
1962/3 | 30.49 |
By its final year of operation in 1963-64 the 'A' station had 1 × 30 MW generator. [13] It produced 28 GWh of electricity in that year. The steam capacity of the boilers was 440,000 lb/hr (55.4 kg/s). The steam conditions at the turbine stop valve was 600 psi (41.4 bar). In 1963-64 the overall thermal efficiency of the A station was 13.06 per cent. [13]
By 1963-64 the 'B' station had 5 × 30 MW generators. [13] There were seven 240,000 lb/hr boilers with a total steam capacity of 1,680,000 lb/hr (211.7 kg/s). Steam conditions at the turbine stop valves was 600 psi (41.4 bar) and 454 °C. The boilers were chain grate stoked and in 1954 burned 27,100 tons of coal. In 1963-64 the overall thermal efficiency of the B station was 24.48 per cent, by the time of its closure the thermal efficiency had fallen to 14.47 per cent. [13]
Electricity output from Acton Lane 'B' power station during its operational life was as follows. [13] [14] [10] [11]
Acton Lane B annual electricity output GWh.
Graphs are temporarily unavailable due to technical issues. |
Willesden Feeder station on the site comprises systems operating at 400 kV to/from Kensal Green substation; 275 kV to/from Ealing substation; 132 kV from Taylors Lane power station, Neasden feeder station, White City substation, North Pole feeder station; 66 kV to Townmead Road substation, Bulwer Street substation; and 22 kV to Acton Lane, Brentham new LUL, and Kimberley Road. [15]
The disused power station was used as a film set in Aliens (1986) and as the 'Axis Chemical Works' in Batman (1989). [16]
The Metropolitan Electric Supply Company Limited also owned and operated a power station at Amberley Road in Westbourne Green adjacent to the Grand Union Canal (51.522632°N 0.192518°W). The station was first commissioned in March 1893. [17] In 1923 the station had four 600 kW steam turbines supplied from boilers producing 96,000 lb/hr (12.1 kg/s) of steam. [8] The station closed in 1926. Today the site is a substation connected to Aberdeen Place substation (132 kV) and to Moscow Road substation (22 kV). [17]
Agecroft power station was a coal-fired power station between the eastern bank of the Manchester, Bolton and Bury Canal and the western bank of the River Irwell at Pendlebury, near Manchester, England. It operated between 1925 and 1993, and was demolished in 1994. HM Prison Forest Bank has since been built on the site.
The Littlebrook Power Station were a series of four oil and coal-fired power stations situated on the south bank of the River Thames, next to the Queen Elizabeth 2 Bridge and the Dartford Tunnel in Dartford, Kent. The final power station, Littlebrook D, ceased operating in March 2015, and has now been demolished.
Brimsdown Power Station was a coal-fired power station on the Lee Navigation at Brimsdown in Middlesex. The station had seven cooling towers which were visible from a wide area.
West Ham Power Station was a coal-fired power station on Bow Creek at Canning Town, in east London. It was often referred to informally as Canning Town Power Station.
Three distinct coal-fired power stations were built at Deptford on the south bank of the River Thames, the first of which is regarded as the first central high-voltage power station in the world.
Peterborough Power Station is a 360MW gas-fired power station at Eastern Industry, Fengate in the city of Peterborough, Cambridgeshire in the United Kingdom. It employs around forty people.
Great Yarmouth Power Station is combined cycle gas turbine power station on South Denes Road in Great Yarmouth in Norfolk, England, with a maximum output of 420 MW electricity, opened in 2001. It is built on the site of an oil-fired power station, built in 1958 and closed and demolished in the 1990s. A coal-fired power station was built in Great Yarmouth in 1894 and operated until 1961. The station is operated by RWE.
Rotherham power station was a coal-fired power station sited close to the centre of Rotherham in South Yorkshire.
Birchills power station and Walsall power station are a series of three coal-fired power stations in, or near, Walsall in the West Midlands, England.
The Croydon power stations refers to a pair of demolished coal-fired power stations and to a gas-fired power station in the Purley Way area of Croydon, London.
Taylors Lane Power Station is situated in Willesden, north-west London. The first power station on the site, known as Willesden power station, was coal-fired and operated from 1903 to 1972 and was subsequently demolished. Taylors Lane is now an open cycle gas turbine (OCGT) power station built in 1979.
Kingston Power Station was a coal-fired generating station on the Thames in Kingston upon Thames, Surrey. It ceased generating in 1980 and has been demolished.
Hackney Power Station was a coal-fired power station situated at Lea Bridge on the River Lee Navigation in London.
Cliff Quay Power Station was a coal-fired power station situated to the south of Ipswich, Suffolk in the East of England. The station was designed by Sir Alexander Gibb & Partners and built by the Cleveland Bridge Company.
Skelton Grange Power Station refers to two now-demolished coal fired power stations that served the city of Leeds and surrounding areas. They were located in the Stourton area of the city. The power stations were built in the early 1950s and early 1960s, taken out of use in 1983 and 1994 and subsequently dismantled but the associated 275 kV switching substation was retained and remains in use.
Watford Power Station was a coal-fired power station situated in Watford's Riverside area. The station was built by the Watford Corporation Electricity Department starting with the installation of cables in 1899 with completion around 1900, near the banks of the River Colne. A gas turbine power station was commissioned in 1980.
Blackburn power stations are a series of electricity generating stations that have provided electric power to the town of Blackburn and the wider area from 1895 to the present. The first station in Jubilee Street, Blackburn began operating in 1895. A new larger station known as Blackburn East or Whitebirk power station was commissioned in 1921 and was rebuilt in stages over the period 1942 to 1955. Whitebirk station closed in 1976. The 60 MW Blackburn Mill Combined Cycle Gas Turbine (CCGT) power station has generated electricity since 2002. The Blackburn energy from waste (EfW) plant is currently (2020) being planned.
Carlisle power stations were two electricity generating stations that supplied electricity to Carlisle and the surrounding area from 1899 until 1980. The first power station (1899–1927) was in the centre of the city near Nelson Bridge, and the second larger station was at Willow Holme North-West of the city (1923–1980).
The Lancaster power stations provided electricity to the Lancashire town and city of Lancaster and the surrounding area from 1894 to 1976. The first power station was built and operated by Lancaster Corporation and started generating electricity in April 1894. The second power station was built during the First World War near the Lune Aqueduct to provide electric power for a munitions factory. When the factory closed after the war the power station was purchased by the corporation to provide electric power throughout its supply area.
The Percival Lane power station in Runcorn was built and operated by the Mersey Power Company Limited. It comprised two stations A and B commissioned in 1921 and 1941. The station supplied electricity to commercial, industrial and domestic users over a wide area of 95 square miles around the River Mersey including Widnes, Ellesmere Port and Runcorn.