Capacitive displacement sensors are a kind of non-contact displacement sensor, measuring the position and change of position in capacitive materials to a high resolution. [1] They are also able to measure the thickness or density of non-conductive materials. [2] Capacitive displacement sensors are used in a wide variety of applications including semiconductor processing, assembly of precision equipment such as disk drives, precision thickness measurements, machine tool metrology and assembly line testing. These types of sensors can be found in machining and manufacturing facilities around the world.
Two identical parallel conductive plates of area separated by a gap of distance will have a capacitance of:
where is the permittivity of free space constant and is the relative permittivity (also called the dielectric constant) of the material in the gap.
There are two general types of capacitive displacement sensing systems. One type is used to measure thicknesses of conductive materials. The other type measures thicknesses of non conductive materials or the level of a fluid.
A capacitive sensing system for conductive materials uses a model similar to the one described above, but in place of one of the conductive plates, is the sensor, and in place of the other, is the conductive target to be measured. Since the area of the probe and target remain constant, and the dielectric of the material in the gap (usually air) also remains constant, "any change in capacitance is a result of a change in the distance between the probe and the target." [4] Therefore, the equation above can be simplified to:
where α indicates a proportional relationship. Due to this proportional relationship, a capacitive sensing system is able to measure changes in capacitance and translate these changes in distance measurements.
The operation of the sensor for measuring thickness of non-conductive materials can be thought of as two capacitors in series, with each having a different dielectric (and dielectric constant). The sum of the thicknesses of the two dielectric materials remains constant but the thickness of each can vary. The thickness of the material to be measured displaces the other dielectric. The gap is often an air gap, (≈1) and the material has a higher dielectric. As the material gets thicker, the capacitance increases and is sensed by the system.
A sensor for measuring fluid levels works as two capacitors in parallel with constant total area. Again the difference in the dielectric constant of the fluid and the dielectric constant of air results in detectable changes in the capacitance between the conductive probes or plates.
One of the more common applications of capacitive sensors is for precision positioning. Capacitive displacement sensors can be used to measure the position of objects down to the nanometer level. This type of precise positioning is used in the semiconductor industry where silicon wafers need to be positioned for exposure. Capacitive sensors are also used to pre-focus the electron microscopes used in testing and examining the wafers.
In the disc drive industry, capacitive displacement sensors are used to measure the runout (a measure of how much the axis of rotation deviates from an ideal fixed line) of disc drive spindles. By knowing the exact runout of these spindles, disc drive manufacturers are able to determine the maximum amount of data that can be placed onto the drives. Capacitive sensors are also used to ensure that disc drive platters are orthogonal to the spindle before data is written to them.
Capacitive displacement sensors can be used to make very precise thickness measurements. Capacitive displacement sensors operate by measuring changes in position. If the position of a reference part of known thickness is measured, other parts can be subsequently measured and the differences in position can be used to determine the thickness of these parts. [5] In order for this to be effective using a single probe, the parts must be completely flat and measured on a perfectly flat surface. If the part to be measured has any curvature or deformity, or simply does not rest firmly against the flat surface, the distance between the part to be measured and the surface it is placed upon will be erroneously included in the thickness measurement. This error can be eliminated by using two capacitive sensors to measure a single part. Capacitive sensors are placed on either side of the part to be measured. By measuring the parts from both sides, curvature and deformities are taken into account in the measurement and their effects are not included in the thickness readings.
The thickness of plastic materials can be measured with the material placed between two electrodes a set distance apart. These form a type of capacitor. The plastic when placed between the electrodes acts as a dielectric and displaces air (which has dielectric constant of 1, different from the plastic). Consequently, the capacitance between the electrodes changes. The capacitance changes can then be measured and correlated with the material's thickness. [6]
Capacitive sensors circuits can be constructed that are able to detect changes in capacitance on the order of a 10−5 picofarads (10 attofarads).
While capacitive displacement sensors are most often used to sense changes in position of conductive targets, they can also be used to sense the thickness and/or density of non-conductive targets as well. [4] A non-conductive object placed in between the probe and conductive target will have a different dielectric constant than the air in the gap and will therefore change the Capacitance between probe and target. (See the first equation above) By analyzing this change in capacitance, the thickness and density of the non-conductor can be determined.
Capacitive displacement sensors are often used in metrology applications. In many cases, sensors are used “to measure shape errors in the part being produced. But they also can measure the errors arising in the equipment used to manufacture the part, a practice known as machine tool metrology”. [7] In many cases, the sensors are used to analyze and optimize the rotation of spindles in various machine tools, examples include surface grinders, lathes, milling machines, and air bearing spindles. [8] By measuring errors in the machines themselves, rather than simply measuring errors in the final products, problems can be dealt with and fixed earlier in the manufacturing process.
Capacitive displacement sensors are often used in assembly line testing. Sometimes they are used to test assembled parts for uniformity, thickness or other design features. At other times, they are used to simply look for the presence or absence of a certain component, such as glue. [9] Using capacitive sensors to test assembly line parts can help to prevent quality concerns further along in the production process.
Capacitive displacement sensors share many similarities to eddy current (or inductive) displacement sensors; however capacitive sensors use an electric field as opposed to the magnetic field used by eddy current sensors [10] [11] This leads to a variety of differences between the two sensing technologies, with the most notable differences being that capacitive sensors are generally capable of higher resolution measurements, and eddy current sensors work in dirty environments while capacitive sensors do not. [10]
In electromagnetism, a dielectric is an electrical insulator that can be polarised by an applied electric field. When a dielectric material is placed in an electric field, electric charges do not flow through the material as they do in an electrical conductor, because they have no loosely bound, or free, electrons that may drift through the material, but instead they shift, only slightly, from their average equilibrium positions, causing dielectric polarisation. Because of dielectric polarisation, positive charges are displaced in the direction of the field and negative charges shift in the direction opposite to the field. This creates an internal electric field that reduces the overall field within the dielectric itself. If a dielectric is composed of weakly bonded molecules, those molecules not only become polarised, but also reorient so that their symmetry axes align to the field.
The relative permittivity is the permittivity of a material expressed as a ratio with the electric permittivity of a vacuum. A dielectric is an insulating material, and the dielectric constant of an insulator measures the ability of the insulator to store electric energy in an electrical field.
In electromagnetism, the absolute permittivity, often simply called permittivity and denoted by the Greek letter ε (epsilon), is a measure of the electric polarizability of a dielectric material. A material with high permittivity polarizes more in response to an applied electric field than a material with low permittivity, thereby storing more energy in the material. In electrostatics, the permittivity plays an important role in determining the capacitance of a capacitor.
Capacitance is the capacity of a material object or device to store electric charge. It is measured by the charge in response to a difference in electric potential, expressed as the ratio of those quantities. Commonly recognized are two closely related notions of capacitance: self capacitance and mutual capacitance. An object that can be electrically charged exhibits self capacitance, for which the electric potential is measured between the object and ground. Mutual capacitance is measured between two components, and is particularly important in the operation of the capacitor, an elementary linear electronic component designed to add capacitance to an electric circuit.
A touchscreen is a type of display that can detect touch input from a user. It consists of both an input device and an output device. The touch panel is typically layered on the top of the electronic visual display of a device. Touchscreens are commonly found in smartphones, tablets, laptops, and other electronic devices. The display is often an LCD, AMOLED or OLED display.
In physics, the electric displacement field or electric induction is a vector field that appears in Maxwell's equations. It accounts for the electromagnetic effects of polarization and that of an electric field, combining the two in an auxiliary field. It plays a major role in topics such as the capacitance of a material, as well as the response of dielectrics to an electric field, and how shapes can change due to electric fields in piezoelectricity or flexoelectricity as well as the creation of voltages and charge transfer due to elastic strains.
Surface plasmon resonance (SPR) is a phenomenon that occurs where electrons in a thin metal sheet become excited by light that is directed to the sheet with a particular angle of incidence, and then travel parallel to the sheet. Assuming a constant light source wavelength and that the metal sheet is thin, the angle of incidence that triggers SPR is related to the refractive index of the material and even a small change in the refractive index will cause SPR to not be observed. This makes SPR a possible technique for detecting particular substances (analytes) and SPR biosensors have been developed to detect various important biomarkers.
Capacitors are manufactured in many styles, forms, dimensions, and from a large variety of materials. They all contain at least two electrical conductors, called plates, separated by an insulating layer (dielectric). Capacitors are widely used as parts of electrical circuits in many common electrical devices.
Level sensors detect the level of liquids and other fluids and fluidized solids, including slurries, granular materials, and powders that exhibit an upper free surface. Substances that flow become essentially horizontal in their containers because of gravity whereas most bulk solids pile at an angle of repose to a peak. The substance to be measured can be inside a container or can be in its natural form. The level measurement can be either continuous or point values. Continuous level sensors measure level within a specified range and determine the exact amount of substance in a certain place, while point-level sensors only indicate whether the substance is above or below the sensing point. Generally the latter detect levels that are excessively high or low.
Nanoindentation, also called instrumented indentation testing, is a variety of indentation hardness tests applied to small volumes. Indentation is perhaps the most commonly applied means of testing the mechanical properties of materials. The nanoindentation technique was developed in the mid-1970s to measure the hardness of small volumes of material.
In electrical engineering, a capacitor is a device that stores electrical energy by accumulating electric charges on two closely spaced surfaces that are insulated from each other. The capacitor was originally known as the condenser, a term still encountered in a few compound names, such as the condenser microphone. It is a passive electronic component with two terminals.
Frequency domain (FD) sensor is an instrument developed for measuring soil moisture content. The instrument has an oscillating circuit, the sensing part of the sensor is embedded in the soil, and the operating frequency will depend on the value of soil's dielectric constant.
Dielectric elastomers (DEs) are smart material systems that produce large strains and are promising for Soft robotics, Artificial muscle, etc. They belong to the group of electroactive polymers (EAP). DE actuators (DEA) transform electric energy into mechanical work and vice versa. Thus, they can be used as both actuators, sensors, and energy-harvesting devices. They have high elastic energy density and fast response due to being lightweight, highly stretchable, and operating under the electrostatic principle. They have been investigated since the late 1990s. Many prototype applications exist. Every year, conferences are held in the US and Europe.
Capacitance sensors use capacitance to measure the dielectric permittivity of a surrounding medium. The configuration is like the neutron probe where an access tube made of PVC is installed in the soil; probes can also be modular (comb-like) and connected to a logger. The sensing head consists of an oscillator circuit, the frequency is determined by an annular electrode, fringe-effect capacitor, and the dielectric constant of the soil. Each capacitor sensor consists of two metal rings mounted on the circuit board at some distance from the top of the access tube. These rings are a pair of electrodes, which form the plates of the capacitor with the soil acting as the dielectric in between. The plates are connected to an oscillator, consisting of an inductor and a capacitor. The oscillating electrical field is generated between the two rings and extends into the soil medium through the wall of the access tube. The capacitor and the oscillator form a circuit, and changes in dielectric constant of surrounding media are detected by changes in the operating frequency. The capacitance sensors are designed to oscillate in excess of 100 MHz inside the access tube in free air. The output of the sensor is the frequency response of the soil’s capacitance due to its soil moisture level.
In electrical engineering, capacitive sensing is a technology, based on capacitive coupling, that can detect and measure anything that is conductive or has a dielectric constant different from air. Many types of sensors use capacitive sensing, including sensors to detect and measure proximity, pressure, position and displacement, force, humidity, fluid level, and acceleration. Human interface devices based on capacitive sensing, such as touchpads, can replace the computer mouse. Digital audio players, mobile phones, and tablet computers will sometimes use capacitive sensing touchscreens as input devices. Capacitive sensors can also replace mechanical buttons.
Optical conductivity is the property of a material which gives the relationship between the induced current density in the material and the magnitude of the inducing electric field for arbitrary frequencies. This linear response function is a generalization of the electrical conductivity, which is usually considered in the static limit, i.e., for time-independent or slowly varying electric fields.
A biotransducer is the recognition-transduction component of a biosensor system. It consists of two intimately coupled parts; a bio-recognition layer and a physicochemical transducer, which acting together converts a biochemical signal to an electronic or optical signal. The bio-recognition layer typically contains an enzyme or another binding protein such as antibody. However, oligonucleotide sequences, sub-cellular fragments such as organelles and receptor carrying fragments, single whole cells, small numbers of cells on synthetic scaffolds, or thin slices of animal or plant tissues, may also comprise the bio-recognition layer. It gives the biosensor selectivity and specificity. The physicochemical transducer is typically in intimate and controlled contact with the recognition layer. As a result of the presence and biochemical action of the analyte, a physico-chemical change is produced within the biorecognition layer that is measured by the physicochemical transducer producing a signal that is proportionate to the concentration of the analyte. The physicochemical transducer may be electrochemical, optical, electronic, gravimetric, pyroelectric or piezoelectric. Based on the type of biotransducer, biosensors can be classified as shown to the right.
Three-dimensional electrical capacitance tomography also known as electrical capacitance volume tomography (ECVT) is a non-invasive 3D imaging technology applied primarily to multiphase flows. It was introduced in the early 2000s as an extension of the conventional two-dimensional ECT. In conventional electrical capacitance tomography, sensor plates are distributed around a surface of interest. Measured capacitance between plate combinations is used to reconstruct 2D images (tomograms) of material distribution. Because the ECT sensor plates are required to have lengths on the order of the domain cross-section, 2D ECT does not provide the required resolution in the axial dimension. In ECT, the fringing field from the edges of the plates is viewed as a source of distortion to the final reconstructed image and is thus mitigated by guard electrodes. 3D ECT exploits this fringing field and expands it through 3D sensor designs that deliberately establish an electric field variation in all three dimensions. In 3D tomography, the data are acquired in 3D geometry, and the reconstruction algorithm produces the three-dimensional image directly, in contrast to 2D tomography, where 3D information might be obtained by stacking 2D slices reconstructed individually.
A force-sensing capacitor is a material whose capacitance changes when a force, pressure or mechanical stress is applied. They are also known as "force-sensitive capacitors". They can provide improved sensitivity and repeatability compared to force-sensitive resistors but traditionally required more complicated electronics.
A loop-gap resonator (LGR) is an electromagnetic resonator that operates in the radio and microwave frequency ranges. The simplest LGRs are made from a conducting tube with a narrow slit cut along its length. The LGR dimensions are typically much smaller than the free-space wavelength of the electromagnetic fields at the resonant frequency. Therefore, relatively compact LGRs can be designed to operate at frequencies that are too low to be accessed using, for example, cavity resonators. These structures can have very sharp resonances making them useful for electron spin resonance (ESR) experiments, and precision measurements of electromagnetic material properties.