Max D. Liston | |
---|---|
Born | Oswego, Kansas, U.S. | March 16, 1918
Citizenship | United States |
Alma mater | University of Minnesota, Chrysler Institute of Engineering |
Known for | Infrared spectrophotometry, Capnometry, Liston-Becker Model 28 Exhaust Gas Analyzer spectrophotometry |
Scientific career | |
Fields | Engineering |
Institutions | Perkin-Elmer, General Motors, Liston-Becker |
Max Davis Liston (born March 16, 1918) is an American pioneer in the development of instruments for infrared spectrophotometry and non-dispersive infrared analysis. [1] Two of his innovations, the breaker-type direct-coupled amplifier and the vacuum thermocouple, were essential to the development of infrared spectrometry technology. [2] Among others, Liston has developed instruments for capnometry, the measurement of carbon dioxide in respiratory gases, used to monitor patients. [3] He also developed instruments to measure smog and car exhaust emissions, essential to attempts to improve Los Angeles air quality in the 1950s. [4]
Max Davis Liston [5] was born on March 16, 1918, in Oswego, Kansas, United States to Virdon (or Verdon) Milne Liston and Madge Ruth Davis. He had an older sister, Lorene. His father was a superintendent of schools. Liston attended high school in Fort Scott, Kansas. [1] [6] Because the science options there were limited, he took summer classes in physics at Northwestern University. [1]
Liston received a B.A. in electrical engineering with a minor in communications (electronics) from the University of Minnesota in 1940. In his junior year he wrote a paper on "Modulation of incandescent lamps", winning an IEEE prize. In his senior year he wrote a "Study of the negative transconductance of pentodes". He was the first undergraduate to be admitted into the University of Minnesota Sigma Psi chapter. [1] : 3
Hired by the Chrysler Corporation, he worked at Chrysler from 1940 to 1942, receiving his M.S. in mechanical engineering in 1941 through an innovative work-study program, the Chrysler Institute of Engineering. He developed a bonded strain gauge pressure sensor, modifying a previous Pullman Company design, and presented the work to the American Automotive Society. [1] : 3
In 1942 Liston joined General Motors. A number of projects at GM were related to World War II, and involved researchers in other companies, universities and government. Initially Liston worked with a group led by Charles F. Kettering at GM to develop a sensor to detect submarines [1] : 4, 6–9 and with Harrison M. Randall of the University of Michigan on the improvement of infrared spectroscopy equipment for analysis of high-octane Triptane aviation fuel. [1] : 5–6
In 1943, Liston developed the breaker-type direct-coupled amplifier. This allowed a signal to be sent directly from a thermocouple to a recording device. [2] It was initially classified as top-secret because of its use in military applications. These included submarine detection instruments, heat-tracking sensors for experimental glide bombs, oximeters for high-altitude aviation, and instruments to measure thermal radiation released in atomic bomb tests for the Manhattan Project. [1] : 6–10 Liston published a paper on the d.c. amplifier in 1954. [7]
Through his war work, Liston met James Elam and George Saxton. [1] : 8 He also met August Herman Pfund of Johns Hopkins University, who had patented both early positive and negative IR-analyzers. [1] : 13 While visiting the Naval Research Laboratories, Liston was able to identify positive type infrared analyzers which had been brought back from Germany at the end of the war. [1] : 8, 14
When GM and Dupont decided to build their own spectrophotometers, Liston and David Frye from GM apprenticed with Harrison Randall at the University of Michigan to learn more about spectrophotometry. They then helped Dr. Downing at Dupont Experimental Station to build a spectrophotometer for use in petrochemical classification and plastics research. [1] : 8–9, 59
To further improve GM's spectrophotometer, Liston worked with Charles Morris Reeder to develop a vacuum thermocouple that eliminated the problem of thermal drift in spectroscopy measurements. The breaker-type direct-coupled amplifier and the vacuum thermocouple became essential contributions to the development of infrared spectrometry technology. [2]
In 1946, Richard Scott Perkin recruited Liston to join Perkin-Elmer as a chief engineer. Liston, John U. White, Van Zandt Williams and Vincent J. Coates formed the double-beam spectrophotometer research group. [2] Liston's breaker amplifier and the Reeder thermocouple were incorporated into designs for the Perkin-Elmer Model 12 single-beam and Model 21 double-beam spectrophotometers, which became extremely successful. [2]
In 1950, Morris Folb and Max Liston formed the Liston-Folb company, focusing on the development of nondispersive infrared analyzers. In 1951, they received backing from Albert Austin and Richard S. Becker, who created the Liston-Becker Instrument Company to handle instrument sales. [1] : 15 The Liston-Becker plant was located in Springdale, Connecticut. [1] : 20 They developed and sold the Model 16 capnograph and Mark II and Mark III atmospheric analyzers for the US Navy's submarines.
Liston's initial development work on the capnograph occurred before the formation of Liston-Folb. Capnometry is the measurement of the concentration of carbon dioxide (CO
2) in the respiratory gases, an important monitoring tool for patients undergoing anesthesia and in intensive care. [3] Liston-Becker was one of a number of companies seeking to develop instruments to measure CO
2 using infrared absorption.
Soon after leaving Perkin-Elmer, Liston was approached by Drs. James Elam and George Saxton, who he had met doing war work, to build a CO
2 analyzer to test their theories about causes of cardiac arrest in anesthesia patients. In 1951, Liston provided Elam with a prototype nondispersive infrared analyzer, which Elam used in his human respiratory physiology research at Barnes Hospital and Washington University in St. Louis, Missouri. After relocating to Roswell Park Comprehensive Cancer Center (then known as the Roswell Park Memorial Institute) in Buffalo, New York in 1953, Elam used a newer Liston-Becker model analyzer in his research. With Liston's apparatus, Elam was able to make important contributions to the study of respiratory physiology, and substantial improvements to anesthesia machines. [8] The color indicators on the instruments were not working properly, allowing patients to inhale high levels of dangerous CO
2 undetected, and a valve in the apparatus tended to stick and cause rebreathing. Once identified, both problems were fixed. [1] : 12 Liston also provided prototypes to Dr. Philip Drinker of Harvard Medical School, to Dr. John Wendell Severinghaus of Johns Hopkins University, and to Dr. J. L. Whittenberger. [1] : 16 Liston's first sale was to Dr. Julius H. Comroe, Jr. at the University of Pennsylvania. [1] : 62
Initially the medical spectrophotometer had a mask-style attachment, into which the patient breathed. This was later modified to use a nasal catheter because many polio patients could not use the mouth-breathing apparatus. [1] : 62 Eventually the Polio Foundation began to use Liston's Model 16 CO2 analyzer to monitor Iron Lung machines, cutting in half both the time that patients spent in the machines and the death rate of Iron Lung machine users. [1] : 12–13
Liston developed an industrial analyzer in response to a request from Dupont. The industrial analyzer performed similar types of analysis, but was built in an explosive-proof case to meet industrial safety requirements. The Model 15 had a cheap metal case and could be used for non-explosive laboratory work. [1] : 16, 62–64
By 1958, Liston-Becker had also delivered several atmospheric-analyzer models for the US Navy's submarines, some of which were tested on the USSN Nautilus , the first atomic-powered submarine. [1] : 67–70 The Navy was interested in monitoring the air quality on submarines during long submersion, particularly the presence of carbon monoxide, carbon dioxide, hydrogen, oxygen and Freon. Liston-Becker redesigned a Pauling Oxygen meter from Beckman Instruments for the oxygen detection. The final atmospheric analyzer had to pass Navy tests for measuring air quality, withstanding shock, and tilt sensitivity. Liston-Becker's first atmosphere analyzers were the Mark II, built in 1953, and the Mark III, built in 1954. Fourteen Mark III analyzers were sold to the Navy, for $75,000 each. [1] : 17–19 After the Beckman Instruments company took over Liston-Becker, Beckman continued the development of the Mark IV and Mark V. [9]
In 1955, Liston's backers, Albert Austin and Richard S. Becker, agreed to sell their company to Beckman Instruments. Max Liston joined Beckman Instruments, Inc. in 1955 and remained with the company until 1965, initially as manager of Liston-Becker. After the Connecticut-based Liston-Becker plant was closed in a reorganization in 1958, Liston became Beckman Instruments Director of Engineering in California. [1] : 20–21
Arnold Beckman lived in Altadena, California and had a strong interest in solving the smog issue. [10] : 207–208 One of Liston's most significant projects at Beckman Instruments involved automobile-emissions analyzers for smog tests in L.A.
In 1952, Arie Jan Haagen-Smit presented results that suggested that car exhausts were a major contributor to the development of California smog. [10] : 220–226 In 1956 the city of Los Angeles conducted emissions tests to determine whether cars were to blame for the smog of Los Angeles. Determining the effects of automobiles required the development of a mobile instrument capable of measuring smog and automobile emissions. The Liston-Becker Model 28 could be put in the back of a car and powered by batteries in the trunk. The city tested 1000 cars, owned by local businesses, at the Los Angeles riverbed. Seven Liston analyzers were used in the tests. [1] : 26, 71 The emissions tests revealed that many of the test cars had poorly maintained V8 engines. The engines' cylinders fired poorly and in some cases raw fuel escaped. The experimenters also discovered that the smog in L.A. caused varnish to form in the automobiles’ carburetors, changing the fuel-to-air ratio. [4] The Model 28 and Model 30 emissions analyzers were sold to major U.S. auto manufacturers such as Chrysler and General Motors and used for the inspection and servicing of automobiles. Liston also worked with Haagen-Smit on equipment for monitoring SO
2 from power stacks and refineries. [1] : 27
While at Beckman Instruments, Liston helped to develop the Mark IV submarine analyzer. [11] He also developed the first pulse oximeter, but Beckman Instruments was not interested in marketing it. [1] : 27 Liston retired from the company in 1965, not long after Arnold Beckman stepped down as president of the company. [1] : 25
After leaving Beckman Instruments, Liston continued to work on a variety of projects with various partners, eventually forming Liston Scientific, of which he became president. [1] [12]
One project was to improve the design of medical respirators, which were of interest to Forrest Bird, Dr. Albert Starr and Miles "Lowell" Edwards of Edwards Lifesciences. Liston believed he could create a ventilator with an integrated circuit to detect when the patient was able to breathe on his own, automatically switching between a preset ventilation rate and a patient-dependent one as needed. He was able to develop such an instrument for Edwards. [1] : 30–31
Another project, involving Miles Edwards, Jr. was the development of an Instrument Positive Pressure Breathalyzer (IPPB) for treating asthma patients. Liston's design was known as the Handi-Vent IPPB. It was later licensed to Ohio Medical Products. [1] : 30–31
SmithKline approached Liston to improve the design of its spectrophotometer. They needed a machine that could meet tight specifications, for analyzing reagents in temperature-dependent rate reactions. Liston's design and 35 prototypes made by Edward Murphy were accepted by SmithKline. Liston Scientific completed its part of the project in 1966, helping to set up the Corbin-Farnsworth factory for production. Liston's design was manufactured by SmithKline as the Alpha spectrophotometer, part of a system called the Escalab. [1] : 31–34
In 1966 and 1967, Liston developed a Digital-Alpha circuit to calculate the logarithmic decay of a capacitor-resistor. The circuit was patented by Liston Scientific in 1967. It was used in bichromatic analyzers which Liston designed for Abbott Laboratories, beginning with the ABA-100. The ABA-100 was a single-reagent double-channel kinetic analyzer for ultra-micro chemical analysis and simultaneous bichromatic spectrophotometry. One module of the instrument performed the chemical processing, dispensing the reagent and sample for the reaction and performing the spectrophotometry measurements. A second module monitored and controlled the processing module and calculated and reported results. [13] Later models incorporated specialty microprocessors instead of memory chips. [1] : 36–43
Liston was interested in developing a multi-channel unit which could handle multiple tests at once, and which would incorporate a sample-identification system to prevent identification errors. When Abbott was not interested in it, Liston went on to develop the Paramax clinical analyzer for Baxter International. [1] : 46–48
Liston developed instruments that used selective binding of fluorescent tags and subsequent photodetection for the examination of chemical compounds. One instrument was designed to test blood samples for steroids and other drugs. Liston also developed specialty test instruments for electrolyte testing, Hemoccult testing, glucose testing and blood urea nitrogen (BUN) analysis. [1] : 49–51 He is an innovator in the area of chemical-luminescence instrumentation, particularly measurement of oxides of nitrogen. [1] : 54
In addition, Liston and Lowell Edwards formed the Liston-Edwards company to work on the measurement of hydrocarbons. They developed an emissions analyzer that detected photo-reactive gases, ignoring non-reactive gases. [1] : 52–53
Analytical chemistry studies and uses instruments and methods to separate, identify, and quantify matter. In practice, separation, identification or quantification may constitute the entire analysis or be combined with another method. Separation isolates analytes. Qualitative analysis identifies analytes, while quantitative analysis determines the numerical amount or concentration.
An optical spectrometer is an instrument used to measure properties of light over a specific portion of the electromagnetic spectrum, typically used in spectroscopic analysis to identify materials. The variable measured is most often the irradiance of the light but could also, for instance, be the polarization state. The independent variable is usually the wavelength of the light or a closely derived physical quantity, such as the corresponding wavenumber or the photon energy, in units of measurement such as centimeters, reciprocal centimeters, or electron volts, respectively.
Ultraviolet (UV) spectroscopy or ultraviolet–visible (UV–VIS) spectrophotometry refers to absorption spectroscopy or reflectance spectroscopy in part of the ultraviolet and the full, adjacent visible regions of the electromagnetic spectrum. Being relatively inexpensive and easily implemented, this methodology is widely used in diverse applied and fundamental applications. The only requirement is that the sample absorb in the UV-Vis region, i.e. be a chromophore. Absorption spectroscopy is complementary to fluorescence spectroscopy. Parameters of interest, besides the wavelength of measurement, are absorbance (A) or transmittance (%T) or reflectance (%R), and its change with time.
In laboratories, a cuvette is a small tube-like container with straight sides and a circular or square cross-section. It is sealed at one end, and made of a clear, transparent material such as plastic, glass, or fused quartz. Cuvettes are designed to hold samples for spectroscopic measurement, where a beam of light is passed through the sample within the cuvette to measure the absorbance, transmittance, fluorescence intensity, fluorescence polarization, or fluorescence lifetime of the sample. This measurement is done with a spectrophotometer.
A pH meter is a scientific instrument that measures the hydrogen-ion activity in water-based solutions, indicating its acidity or alkalinity expressed as pH. The pH meter measures the difference in electrical potential between a pH electrode and a reference electrode, and so the pH meter is sometimes referred to as a "potentiometric pH meter". The difference in electrical potential relates to the acidity or pH of the solution. Testing of pH via pH meters (pH-metry) is used in many applications ranging from laboratory experimentation to quality control.
A scientific instrument is a device or tool used for scientific purposes, including the study of both natural phenomena and theoretical research.
Arnold Orville Beckman was an American chemist, inventor, investor, and philanthropist. While a professor at California Institute of Technology, he founded Beckman Instruments based on his 1934 invention of the pH meter, a device for measuring acidity, later considered to have "revolutionized the study of chemistry and biology". He also developed the DU spectrophotometer, "probably the most important instrument ever developed towards the advancement of bioscience". Beckman funded the Shockley Semiconductor Laboratory, the first silicon transistor company in California, thus giving rise to Silicon Valley. After retirement, he and his wife Mabel (1900–1989) were numbered among the top philanthropists in the United States.
Spectrophotometry is a branch of electromagnetic spectroscopy concerned with the quantitative measurement of the reflection or transmission properties of a material as a function of wavelength. Spectrophotometry uses photometers, known as spectrophotometers, that can measure the intensity of a light beam at different wavelengths. Although spectrophotometry is most commonly applied to ultraviolet, visible, and infrared radiation, modern spectrophotometers can interrogate wide swaths of the electromagnetic spectrum, including x-ray, ultraviolet, visible, infrared, and/or microwave wavelengths.
A photometer is an instrument that measures the strength of electromagnetic radiation in the range from ultraviolet to infrared and including the visible spectrum. Most photometers convert light into an electric current using a photoresistor, photodiode, or photomultiplier.
Beckman Coulter, Inc. is a Danaher Corporation company that develops, manufactures, and markets products that simplify, automate, and innovate upon complex biomedical testing. It operates in two industries: Diagnostics and Life Sciences. For more than 80 years, Beckman Coulter Inc. has helped healthcare and laboratory professionals, pharmaceutical and biotechnology companies, universities, medical schools, and research institutions worldwide.
Total organic carbon (TOC) is an analytical parameter representing the concentration of organic carbon in a sample. TOC determinations are made in a variety of application areas. For example, TOC may be used as a non-specific indicator of water quality, or TOC of source rock may be used as one factor in evaluating a petroleum play. For marine surface sediments average TOC content is 0.5% in the deep ocean, and 2% along the eastern margins.
Stanford Research Systems is a maker of general test and measurement instruments. The company was founded in 1980, is privately held, and is not affiliated with Stanford University.
Henry Cary was an American engineer and the co-founder of the Applied Physics Corporation, along with George W. Downs and William Miller. The Cary 14 UV-Vis-NIR and the Cary Model 81 Raman Spectrophotometer were particularly important contributions in scientific instrumentation and spectroscopy. Before starting Applied Physics, Cary was employed by Beckman Instruments, where he worked on the design of several instruments including the ubiquitous DU spectrophotometer. Howard Cary was a founder and the first president of the Optical Society of Southern California.
The Spectronic 20 is a brand of single-beam spectrophotometer, designed to operate in the visible spectrum across a wavelength range of 340 nm to 950 nm, with a spectral bandpass of 20 nm. It is designed for quantitative absorption measurement at single wavelengths. Because it measures the transmittance or absorption of visible light through a solution, it is sometimes referred to as a colorimeter. The name of the instrument is a trademark of the manufacturer.
Brüel & Kjær is a Danish multinational engineering and electronics company headquartered in Nærum, near Copenhagen. It was the largest producer in the world of equipment for acoustic and vibrational measurements. Brüel & Kjær is a subsidiary of Spectris.
Stray light is light in an optical system which was not intended in the design. The light may be from the intended source, but follow paths other than intended, or it may be from a source other than that intended. This light will often set a working limit on the dynamic range of the system; it limits the signal-to-noise ratio or contrast ratio, by limiting how dark the system can be. Ocular straylight is stray light in the human eye.
Masao Horiba was a Japanese businessman. In 1945, he founded Horiba Radio Laboratory, now Horiba Ltd., a manufacturer of advanced analytical and measurement technology. Masao Horiba received several awards from the Japanese government including a national Blue Ribbon Medal, and was the first non-American to receive the Pittcon Heritage Award.
R. Robert Brattain was an American physicist at Shell Development Company. He was involved in a number of secret projects during World War II. He is recognized as one of America's leading infrared spectroscopists for his work in designing several models of spectrophotometer, and for using the infrared spectrophotometer to determine the β-lactam structure of penicillin. His instrumentation work was essential to the subsequent study and understanding of structures in organic chemistry.
The DU spectrophotometer or Beckman DU, introduced in 1941, was the first commercially viable scientific instrument for measuring the amount of ultraviolet light absorbed by a substance. This model of spectrophotometer enabled scientists to easily examine and identify a given substance based on its absorption spectrum, the pattern of light absorbed at different wavelengths. Arnold O. Beckman's National Technical Laboratories developed three in-house prototype models and one limited distribution model (D) before moving to full commercial production with the DU. Approximately 30,000 DU spectrophotometers were manufactured and sold between 1941 and 1976.
The Cary Model 14 UV-VIS Spectrophotometer was a double beam recording spectrophotometer designed to operate over the wide spectral range of ultraviolet, visible and near infrared wavelengths (UV/Vis/NIR). This included wavelengths ranging from 185 nanometers to 870 nanometers.