Avometer

Last updated
Final version of AVOmeter model 8 produced from 1951 to 2008 (Mk7 pictured) AVO Model 8 Mk7 P4 by Megger.jpg
Final version of AVOmeter model 8 produced from 1951 to 2008 (Mk7 pictured)
Early version of the AVOmeter. AVOmeter.jpg
Early version of the AVOmeter.
Avometer 15 Volt BLR121 battery Avometer BLR121 battery.jpg
Avometer 15 Volt BLR121 battery

AVOmeter is a British trademark for a line of multimeters and electrical measuring instruments; the brand is now owned by the Megger Group Limited. The first Avometer was made by the Automatic Coil Winder and Electrical Equipment Co. in 1923, and measured direct voltage, direct current and resistance. [1] Possibly the best known multimeter of the range was the Model 8, which was produced in various versions from May 1951 until 2008; the last version was the Mark 7.

Contents

The multimeter is often called simply an AVO, because the company logo carries the first letters of 'amps', 'volts' and 'ohms'. The design concept is due to the Post Office engineer Donald Macadie, who at the time of the introduction of the original AVOmeter in 1923 was a senior officer in the Post Office Factories Department in London.

Technical features

The original AVOmeter was designed to measure direct current (3 ranges, 0.12, 1.2 & 12 A), direct voltage (3 ranges, 12, 120 & 600 V) and resistance (single range, 0 - 10,000 ohms, 225 ohms mid-scale). All ranges could be selected by a single rotary switch which set both the function and the range value. A second switch brought a rheostat into circuit in series with the instrument and could be used to control the current through a device under test and the meter. The movement drew 12 mA for full-scale deflection and used a "universal shunt" permanently in parallel with the movement which increased the input terminal full-scale current to 16.6 mA, corresponding to 60 ohms per volt. It had a knife edge pointer and an anti-parallax mirror.

Additional patents were taken out in Czechoslovakia (1923), [2] Austria, [3] France, [4] Germany, [5] and Switzerland [6] (1924). A US patent [7] followed in 1926

The case of the original AVOmeter was a comb-jointed oak box with an ebonite lower front panel. The upper part of the front panel was cast aluminium.

After around three years production, the volume of sales was sufficient to justify a redesign of the instrument, now with a movement whose full-scale current was 6 mA. The redesigned meter had 13 ranges and was constructed on a one piece phenolic moulding with the characteristic "kidney" shaped window. The back case was a deep drawn aluminium can on the back of which was a summary of the operating instructions, a feature of all future AVOmeters. The movement was originally protected by a short length of wire, selected to act as a fuse, soldered to supports on the back of the movement. Later versions had a calibrated, screw-in, fuse on the front panel.

After copper oxide instrument rectifiers became available in the late 1920s, a 20-range "Universal" version of the AVOmeter was introduced in 1931 having both direct and alternating voltage current ranges. [8] [9] Unlike many similar multimeter designs, all Universal AVOmeters, with the exception of the short-lived "High Resistance (HR) AVOmeter" (c. 1948 - 1951), could measure up to either 10 A or 12 A (AC) depending on the model.

From 1933, the number of available voltage and current ranges in Universal AVOmeters was doubled by incorporating a dual sensitivity movement circuit. [10] The higher sensitivity was selected by a push button switch marked ÷2 (Divide by two) signifying that the pointer indication should be halved. For the Model 8, this feature was not used but the push button was retained for reversing the direction of deflection of the moving coil.

A design feature of AVOmeters was simplicity of use and towards this end, all measurements could generally be made using only two input terminals. However, the AVOmeter HR had additional 2500 V (AC) and (DC) ranges which used the corresponding 1000 V ranges, and were connected through two additional terminals at the top corners of the front panel. This feature was continued in the Model 8 and, with an increase to 3000 V to match their 1 - 3 - 10 ranges sequence, in the Model 9, Marks II and IV and the Model 8 Mark V. The 3000 V ranges were deleted in the Model 8 Marks 6 and 7 due to concerns for compliance with contemporary safety standards. This also led to a significant cost saving by eliminating the high voltage multiplier resistors.

As an ohmmeter the Model 8 Mark II measures from 1 Ω up to 20 MΩ in three ranges. The instrument has an accuracy of ±1% of FSD on DC current ranges, ±2% of FSD on DC voltage ranges, ±2.25% of FSD on all AC ranges and ±5% of reading (at centre scale only) on resistance ranges. [11] Its maximum current draw of 50 μA at full-scale deflection (corresponding to 20,000 ohms per volt) is sufficient in most cases to reduce voltage measurement error due to circuit loading by the meter to an acceptable level.

The AVOmeter design incorporates an electrical interlock which prevents AC & DC ranges being selected simultaneously. [12] For example, none of the DC ranges, current or voltage, can be connected unless the AC switch is set to its "DC" position. On a Model 8, this is the position with the AC switch arrow vertical. Similarly, to use the AC ranges, the DC switch must be set to its "AC" position.

With the DC switch set to its "AC" position and the AC switch set to "DC", no current can flow through the instrument. However whenever any moving coil instrument is likely to be subjected to heavy shock in transit, it is good practice to damp the movement by short circuiting the moving coil using a heavy gauge wire connected across the terminals. On earlier Avometers, this may be done by short-circuiting the input terminals and selecting the most sensitive direct current range. The Model 8 Mark V, 6 & 7 were provided with an "OFF" position on the DC switch which both disconnected the meter's terminals and short-circuited the moving coil.

AVOmeters designed from 1936 onwards were fitted with an overload cut-out operated by the moving coil frame hitting either forward or reverse sprung end stops. [13] The Model 7 was the first type to use the end stop cut-out and it also featured an acceleration trip which, in the event of heavy overloads, could open the cut-out before the pointer had reached two-thirds of full scale. The acceleration cut-out was not however used in the Model 8. From the Mark III version, the Model 8 had further protection by a fuse on its resistance ranges and fuse protection was provided on all ranges of the Model 8 Marks 6 & 7.

AVO multimeters were almost ubiquitous in British manufacturing and service industry, research and development and higher and further education. They were also widely used by utilities, government agencies and the British armed forces. A number of special versions were produced to British Admiralty and Air Ministry specifications and for other customers. The Model 8 Marks V, 6 & 7 were designed to meet a NATO specification and were standard issue to NATO services. Many commercial and military service manuals specified that values for measurements of current or voltage had been made with a Model 7 or Model 8 AVOmeter. Advertisements of the late 1930s compared the utility of the AVOmeter to the slide rule. Even nowadays it can still be found in regular use.

The earlier versions of models 7, 8 and 9 had a design flaw which resulted in many instruments sustaining damage to the movement in transit. Users would habitually 'switch off' the instrument by setting the AC switch to 'DC' and the DC switch to 'AC'. With the switches at these settings, the movement is completely undamped. [14] The operating manuals for the affected instruments did contain a note that they should not be switched to 'AC' and 'DC' (or the blank position either side of the 'AC' and 'DC') though failed to explain why. [15] The problem was solved on later instruments by providing the DC switch with an 'OFF' position (see illustration above).

Present times

Despite continuing demand from customers, production was stopped in 2008, reportedly due to increasing problems with suppliers of mechanical parts. [16] The last meter to leave the factory was an AVOmeter Eight Mk 7 (Serial Number 6110-610/081208/5166) which was presented in February 2010 to the winner of a competition run by the Megger company. [17]

Principal models

General purpose multimeters

"The AVOmeter" - 1923 to 1928 7 ranges direct current, direct voltage and resistance

(DC) AVOmeter - 1928 to 1939, Originally 13 ranges, later extended to 22 ranges through use of "divide by two" push button switch

Universal AVOmeter - 1931 to 1939, originally 20 ranges, later extended 34 and 36 ranges through use of "divide by two" push button switch, replaced by Model 40

Universal AVOmeter Model 40 1939 to c. 1986. A development of the 36-range Universal AVOmeter incorporating automatic cut-out and internal construction similar to the Model 7 (Basic ranges to 12 A and 1200 V, the former extendable with accessory current shunts). 167 ohms/volt. [18] [19]

"High Sensitivity" meters principally for Radio and Electronics

Universal AVOmeter 50-range Later known as Model 7 (1936 to c. 1986): A "High Sensitivity" multimeter for radio servicing. (Basic ranges to 10 A and 1000 V, the former extendable with accessory current shunts. A power factor and wattage unit was also available). 500 ohms/volt with divide by two button in normal position, 1000 ohms per volt with divide by two button pressed. [20]

(The features of the Models 8 and 9 were combined from the Model 8 Mark V of 1972, when the Model 9 was discontinued).

Special Purpose Multimeters

"Minor" Models

AVOminor (1935 to 1952) - A small instrument with direct current, direct voltage and resistance ranges only. Ranges selected by plugging leads into required socket.

Universal AVOminor (1936 to 1952) - A small instrument with AC & DC ranges selected by plugging leads into required socket.

All current and voltage ranges for above are both AC and DC unless otherwise stated.

Other products

AVO Meter Survey Radiac Mk.6 geiger counter Radiac Survey Meter Mk6.jpeg
AVO Meter Survey Radiac Mk.6 geiger counter

The company manufactured geiger counters for civil defence use during the 1950s and 60s.

The Automatic Coil Winder & Electrical Equipment Co. Ltd. made many other types of instruments, including a line of valve (vacuum tube) testers. [24]

Related Research Articles

Ammeter Device that measures electric current

An ammeter is a measuring instrument used to measure the current in a circuit. Electric currents are measured in amperes (A), hence the name. The ammeter is usually connected in series with the circuit in which the current is to be measured. An ammeter usually has low resistance so that it does not cause a significant voltage drop in the circuit being measured.

Resistor Passive electrical component providing electrical resistance

A resistor is a passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements, or as sensing devices for heat, light, humidity, force, or chemical activity.

Volt SI derived unit of voltage

The volt is the SI derived unit for electric potential, electric potential difference (voltage), and electromotive force. It is named after the Italian physicist Alessandro Volta (1745–1827).

Voltmeter Instrument used for measuring voltage

A voltmeter is an instrument used for measuring electric potential difference between two points in an electric circuit. It is connected in parallel. It usually has a high resistance so that it takes negligible current from the circuit.

Ohmmeter Tool for measuring electrical resistance

An ohmmeter is an electrical instrument that measures electrical resistance. Multimeters also function as ohmmeters when in resistance-measuring mode. An ohmmeter applies current to the circuit or component whose resistance is to be measured. It then measures the resulting voltage and calculates the resistance using Ohm’s law .

Multimeter Electronic measuring instrument that combines several measurement functions in one unit

A multimeter is a measuring instrument that can measure multiple electrical properties. A typical multimeter can measure voltage, resistance, and current, in which case it is also known as a volt-ohm-milliammeter (VOM), as the unit is equipped with voltmeter, ammeter, and ohmmeter functionality. Some feature the measurement of additional properties such as temperature and capacitance.

Alternating current Electric current that periodically reverses direction

Alternating current (AC) is an electric current which periodically reverses direction and changes its magnitude continuously with time in contrast to direct current (DC) which flows only in one direction. Alternating current is the form in which electric power is delivered to businesses and residences, and it is the form of electrical energy that consumers typically use when they plug kitchen appliances, televisions, fans and electric lamps into a wall socket. A common source of DC power is a battery cell in a flashlight. The abbreviations AC and DC are often used to mean simply alternating and direct, as when they modify current or voltage.

Voltage regulator System designed to maintain a constant voltage

A voltage regulator is a system designed to automatically maintain a constant voltage. A voltage regulator may use a simple feed-forward design or may include negative feedback. It may use an electromechanical mechanism, or electronic components. Depending on the design, it may be used to regulate one or more AC or DC voltages.

Line level is the specified strength of an audio signal used to transmit analog audio between components such as CD and DVD players, television sets, audio amplifiers, and mixing consoles.

HVDC converter station

An HVDC converter station is a specialised type of substation which forms the terminal equipment for a high-voltage direct current (HVDC) transmission line. It converts direct current to alternating current or the reverse. In addition to the converter, the station usually contains:

In electronics, a shunt is a device that creates a low-resistance path for electric current, to allow it to pass around another point in the circuit. The origin of the term is in the verb 'to shunt' meaning to turn away or follow a different path.

Wattmeter

The wattmeter is an instrument for measuring the electric active power in watts of any given circuit. Electromagnetic wattmeters are used for measurement of utility frequency and audio frequency power; other types are required for radio frequency measurements.

Contactor Electronic circuit element serving as a switch

A contactor is an electrically-controlled switch used for switching an electrical power circuit. A contactor is typically controlled by a circuit which has a much lower power level than the switched circuit, such as a 24 volt coil electromagnet controlling a 240 volt motor switch.

Solenoid voltmeter

A solenoid voltmeter is a specific type of voltmeter electricians use to test electrical power circuits. It uses a solenoid coil to attract a spring-loaded plunger; the movement of the plunger is calibrated in terms of approximate voltage. It is more rugged than a D'arsonval movement, but neither as sensitive nor as precise.

Current clamp Tool for measuring electrical current

In electrical and electronic engineering, a current clamp, also known as current probe, is an electrical device with jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe.

Test probe

A test probe is a physical device used to connect electronic test equipment to a device under test (DUT). Test probes range from very simple, robust devices to complex probes that are sophisticated, expensive, and fragile. Specific types include test prods, oscilloscope probes and current probes. A test probe is often supplied as a test lead, which includes the probe, cable and terminating connector.

Capacitor discharge ignition

Capacitor discharge ignition (CDI) or thyristor ignition is a type of automotive electronic ignition system which is widely used in outboard motors, motorcycles, lawn mowers, chainsaws, small engines, turbine-powered aircraft, and some cars. It was originally developed to overcome the long charging times associated with high inductance coils used in inductive discharge ignition (IDI) systems, making the ignition system more suitable for high engine speeds. The capacitive-discharge ignition uses capacitor discharge current to the coil to fire the spark plugs.

A regulated power supply is an embedded circuit; it converts unregulated AC into a constant DC. With the help of a rectifier it converts AC supply into DC. Its function is to supply a stable voltage, to a circuit or device that must be operated within certain power supply limits. The output from the regulated power supply may be alternating or unidirectional, but is nearly always DC. The type of stabilization used may be restricted to ensuring that the output remains within certain limits under various load conditions, or it may also include compensation for variations in its own supply source. The latter is much more common today.

Megger Group Limited

Megger Group Limited is a British manufacturing company that manufactures electronic test equipment and measuring instruments for electrical power applications.

An ESR meter is a two-terminal electronic measuring instrument designed and used primarily to measure the equivalent series resistance (ESR) of real capacitors; usually without the need to disconnect the capacitor from the circuit it is connected to. Other types of meters used for routine servicing, including normal capacitance meters, cannot be used to measure a capacitor's ESR, although combined meters are available which measure both ESR and out-of-circuit capacitance. A standard (DC) milliohmmeter or multimeter cannot be used to measure ESR, because a steady direct current cannot be passed through the capacitor. Most ESR meters can also be used to measure non-inductive low-value resistances, whether or not associated with a capacitor; this leads to a number of additional applications described below.

References

  1. GB Patent 200977
  2. Czech Patent CA236252
  3. Austrian Patent AT98613B
  4. French Patent FR566295
  5. German Patent DE405863
  6. Swiss Patent CH107655
  7. US Patent US1593024
  8. L. O. Grondahl and P. H. Geiger, A New Electronic Rectifier, A. 1. E. E. 46, 357-366 (1927).
  9. GB Patent GB404015
  10. GB Patent GB423199
  11. "Archived copy" (PDF). Archived (PDF) from the original on 2016-03-04. Retrieved 2012-10-09.{{cite web}}: CS1 maint: archived copy as title (link) AVO Model 8 Service Manual.
  12. GB Patent GB404015 Claim 6
  13. GB Patent GB464867
  14. Model 7, 8 and 9 schematic diagrams.
  15. AVOmeter user manual for AVO 8 Mk 2.
  16. Tom Wilson. "www.electronicsweekly.com / Megger bids farewell to AVO 8". Electronicsweekly.com. Retrieved 2009-09-24.
  17. "Own the last ever Avo!". ee Publishers. 2009-09-09. Archived from the original on 2012-08-01. Retrieved 2010-03-03.
  18. "Avometer Model 40 Equipment AVO LTD.; London, build 1950 ??". Archived from the original on 2016-03-04. Retrieved 2012-11-05.
  19. "Avometer Model 40 | Another fine example of British electric… | Flickr". www.flickr.com. Archived from the original on 9 March 2021. Retrieved 6 June 2022.
  20. "Archived copy". Archived from the original on 2016-03-03. Retrieved 2012-11-02.{{cite web}}: CS1 maint: archived copy as title (link) Avo Model 7 Mk2 Service manual
  21. "Universal AVOMeter 8 MK V (MK5) Equipment AVO LTD.; London". Archived from the original on 2016-03-04. Retrieved 2012-11-05.
  22. "Universal AVOMeter 9 MK II Equipment AVO LTD.; London". Archived from the original on 2016-03-04. Retrieved 2012-11-05.
  23. Avo Multiminor Mk 4 User Manual
  24. Alan Douglas, Tube Testers and Classic Electronic Test Gear, pages 23-25