Deaerator

Last updated
A deaerator plant Open deaerator plant.jpg
A deaerator plant

A deaerator is a device that is used for the removal of dissolved gases like oxygen from a liquid.

Contents

Thermal deaerators are commonly used to remove dissolved gases in feedwater for steam-generating boilers. The deaerator is part of the feedwater heating system. [1] [2] Dissolved oxygen in feedwater will cause serious corrosion damage in a boiler by attaching to the walls of metal piping and other equipment forming oxides (like rust). Dissolved carbon dioxide combines with water to form carbonic acid that may cause further corrosion. Most deaerators are designed to remove oxygen down to levels of 7 parts per billion by weight or less, as well as essentially eliminating carbon dioxide. [3] [4]

Vacuum deaerators are used to remove dissolved gases from products such as food, personal care products, cosmetic products, chemicals, and pharmaceuticals to increase the dosing accuracy in the filling process, to increase product shelf stability, to prevent oxidative effects (e.g. discolouration, changes of smell or taste, rancidity), to alter pH, and to reduce packaging volume. [5]

Manufacturing of deaerators started in the 1800s and continues to the present day.[ citation needed ]

History

Manufacturing of deaerators started in the 1800s.They were used to purify water used in the ice manufacturing process. [6] Feed water heaters were used for marine applications. [7] In 1899, George M Kleucker received a patent for an improved method of de-aerating water. [8]

Two sister ships, Olympic and Titanic (1912), had contact feed heaters on board. [9] In 1934 the US Navy purchased an atomizing deaerator. [10]

During the 1920s the feedwater heaters and deaerators designs improved. [11] [12] [13]

Between 1921 and 1933, George Gibson, Percy Lyon, and Victor Rohlin of Cochrane received deaerator / degasification patents for bubbling steam through liquid. [14] [15] [16]

1926 Brown Stanley received a patent for reducing oxygen and nitrogen gases (deaeration). [17]

In 1937 Samuel B Applebaum of Permutit received a water deaerator and purifier patent. [18] [19]

Deaerators continue to be used today for many applications.[ citation needed ]

Principles

Oxygen and Nitrogen are two non-condensable gases that are removed by deaeration. Henry's law describes the relationship of dissolved gases and partial pressures. Thermal deaeration relies on the principle that the solubility of a gas in water decreases as the water temperature increases and approaches its boiling point. In the deaerator, water is heated up to close to its boiling point with a minimum pressure drop and minimum vent. Deaeration is done by spraying feedwater into a chamber to increase its surface area, and may involve flow over multiple layers of trays. This scrubbing (or stripping) steam is fed to the bottom of the deaeration section of the deaerator. When steam contacts the feedwater, it heats it up to its boiling point and dissolved gases are released from the feedwater and vented from the deaerator through the vent. The treated water falls into a storage tank below the deaerator. [20] [3]

Oxygen scavenging chemicals are very often added to the deaerated boiler feedwater to remove any last traces of oxygen that were not removed by the deaerator. The type of chemical added depends on whether the location uses a volatile or non-volatile water treatment program. Most lower pressure systems (lower than 650 psi (4,500 kPa)) use non-volatile treatment programs. The most commonly used oxygen scavenger for lower pressure systems is sodium sulfite (Na2SO3). It is very effective and rapidly reacts with traces of oxygen to form sodium sulfate (Na2SO4) which is non-scaling. Most higher pressure systems (higher than 650 psi (4,500 kPa)) and all systems where certain highly alloyed materials are present are now using volatile programs, as many phosphate-based treatment programs are being phased out. Volatile programs are further broken down into oxidizing or reducing programs [(AVT(O) or AVT(R)] depending whether the environment requires an oxidizing or reducing environment to reduce the incidence of flow-accelerated corrosion. Flow-accelerated corrosion related failures have caused numerous accidents in which significant loss of property and life has occurred.[ citation needed ] Hydrazine (N2H4) is an oxygen scavenger commonly used in volatile treatment programs. Other scavengers include carbohydrazide, diethylhydroxylamine, nitrilotriacetic acid, ethylenediaminetetraacetic acid, and hydroquinone.

Thermal deaerators

Schematic diagram of a typical tray-type deaerator Deaerator-en.svg
Schematic diagram of a typical tray-type deaerator
Schematic diagram of a typical spray-type deaerator SprayDeaerator-en.svg
Schematic diagram of a typical spray-type deaerator

Thermal deaerators are commonly used to remove dissolved gases in feedwater for steam-generating boilers. Dissolved oxygen in feedwater will cause serious corrosion damage in a boiler by attaching to the walls of metal piping and other equipment forming oxides (like rust). Dissolved carbon dioxide combines with water to form carbonic acid that may cause further corrosion. Most deaerators are designed to remove oxygen down to levels of 7 parts per billion by weight or less, as well as essentially eliminating carbon dioxide. [3] [4] The deaerators in the steam generating systems of most thermal power plants use low pressure steam obtained from an extraction point in their steam turbine system. However, the steam generators in many large industrial facilities such as petroleum refineries may use whatever low-pressure steam is available.[ citation needed ]

Tray-type

The tray-type deaerator has a vertical domed deaeration section mounted above a horizontal boiler feedwater storage vessel. Boiler feedwater enters the vertical deaeration section through spray valves above the perforated trays and then flows downward through the perforations. Low-pressure deaeration steam enters below the perforated trays and flows upward through the perforations. Combined action of spray valves & trays guarantees very high performance because of longer contact time between steam and water. [21] [ verification needed ] Some designs use various types of packed beds, rather than perforated trays, to provide good contact and mixing between the steam and the boiler feed water.[ citation needed ]

The steam strips the dissolved gas from the boiler feedwater and exits via the vent valve at the top of the domed section. If this vent valve has not be opened sufficiently, the deaerator will not work properly, resulting in feed water with a high oxygen content going to the boilers. Should the boiler not have an oxygen-content analyzer, a high level in the boiler chlorides may indicate the vent valve not being far enough open. Some designs may include a vent condenser to trap and recover any water entrained in the vented gas. The vent line usually includes a valve and just enough steam is allowed to escape with the vented gases to provide a small visible telltale plume of steam.[ citation needed ]

The deaerated water flows down into the horizontal storage vessel from where it is pumped to the steam generating boiler system. Low-pressure heating steam, which enters the horizontal vessel through a Sparge Pipe in the bottom of the vessel, is provided to keep the stored boiler feedwater warm. Stainless steel material is recommended for the sparger pipe. [22] External insulation of the vessel is typically provided to minimize heat loss.

Spray-type

The typical spray-type deaerator is a horizontal vessel which has a preheating section and a deaeration section. The two sections are separated by a baffle. Low-pressure steam enters the vessel through a sparger in the bottom of the vessel. The boiler feedwater is sprayed into section where it is preheated by the rising steam from the sparger. The purpose of the feedwater spray nozzle and the preheat section is to heat the boiler feedwater to its saturation temperature to facilitate stripping out the dissolved gases in the following deaeration section. The preheated feedwater then flows into the deaeration section (F), where it is deaerated by the steam rising from the sparger system. The gases stripped out of the water exit via the vent at the top of the vessel. Again, some designs may include a vent condenser to trap and recover any water entrained in the vented gas. Also again, the vent line usually includes a valve and just enough steam is allowed to escape with the vented gases to provide a small and visible telltale plume of steam. The deaerated boiler feedwater is pumped from the bottom of the vessel to the steam generating boiler system. Silencers (optional) have been used for reducing venting noise levels in the Deaerator equipment industry.[ citation needed ]

Vacuum deaerators

Schematic diagram of rotating disc deaerator Vacuum rotating disc deaerator.jpg
Schematic diagram of rotating disc deaerator

Deaerators are also used to remove dissolved gases from products such as food, personal care products, cosmetic products, chemicals, and pharmaceuticals to increase the dosing accuracy in the filling process, to increase product shelf stability, to prevent oxidative effects (e.g. discolouration, changes of smell or taste, rancidity), to alter pH, and to reduce packaging volume. Vacuum deaerators are also used in the petrochemical field. [5]

In 1921 a tank with vacuum pump for removing gases was used in Pittsburgh. [23] In 1934 and 1940 a tank with vacuum pump for removing gases were used in Indiana. [24] [25]

Vacuum deaerators can be rubber lined on the inside to protect the steel heads and shell from corrosion. [26]

Rotating Disc

In a typical design, the product is distributed as a thin layer on a high speed spinning disc via special feed system. The centrifugal force slings it through a perforated screen onto the inner wall of the vessel, which is under vacuum. Air (gas) pockets are released in the process and are drawn off by the vacuum. A discharge pump carries the deaerated product to the next process in the production line. For high viscous products the rotating disc is replaced with static one.[ citation needed ]

Other types

Sound waves using ultrasonic equipment can be used to assist deaerating water. [27] [28]

Production

Welding of the steel pressure vessels during the manufacturing process sometimes requires Post weld heat treatment, XRAY, Dye Penetration, Ultrasonic, and other type non-destructive testing. ASME Boiler and Pressure Vessel Code, NACE International, and HEI (Heat Exchange Institute) have recommendations on the type of testing required. [29] Older fabrication techniques also used cast iron for the shell and heads. [30]

Thermal insulation is sometimes required after fabrication or after installation at the project site. Insulation is used to reduce heat loses. [31]

Inspection and maintenance

NACE International (now known as Association for Materials Protection and Performance (AMPP)) and CIBO (Council of Industrial Boiler Owners) have several recommendations to increase the life of the deaerator unit. First, regular inspections (and testing) of the pressure vessel for cracking of welds, and repairing of any weld defects. Second, maintaining a proper water chemistry to reduce deaerator deterioration. Third, minimize temperature and pressure fluctuation. Fourth, internals and accessories should be inspected for proper operation. [32] [33] [34] NACE had created a Corrosion Task Group in 1984 that studied causes of corrosion and provided recommendations; [35] NACE still provides recommendations to improve operations of the equipment.

Manufacturers

Stickle, Cochrane, and Permutit are three of the oldest Deaerator manufacturers in the USA. [36] [37] In 1929, a court case between Elliott Company (no longer in business) and H.S.B.W. Cochrane Corporation allowed both businesses to continue manufacturing deaerators. [38]

In 1909 Weir was manufacturing contact feed heaters (for de-aerating) in Europe. [39] [40] [41]

By 1937 Permutit was manufacturing deaerators. [42] [19]

In 1939, Cochrane, Darby, Elliott, Groeschel, Stearns-Rogers, Worthington, and others were competing against each other for business. [43] In 1949 Chicago Heater was formed and became a leading deaerator manufacturer. [44] In 1954, Allis-Chalmers, Chicago Heater, Cochrane, Elliott, Graver, Swartwout, Worthington, and others were in business. [45]

Applications

Deaerators are used in many industries such as co-generation plants, hospitals, larger laundry facilities, oil fields, oil refineries, off-shore platforms, paper mills, power plants, prisons, steel mills, and many other industries.[ citation needed ]

See also

Related Research Articles

<span class="mw-page-title-main">Boiler</span> Closed vessel in which fluid is heated

A boiler is a closed vessel in which fluid is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, including water heating, central heating, boiler-based power generation, cooking, and sanitation.

<span class="mw-page-title-main">Safety valve</span> Device for releasing excess pressure in a system

A safety valve is a valve that acts as a fail-safe. An example of safety valve is a pressure relief valve (PRV), which automatically releases a substance from a boiler, pressure vessel, or other system, when the pressure or temperature exceeds preset limits. Pilot-operated relief valves are a specialized type of pressure safety valve. A leak tight, lower cost, single emergency use option would be a rupture disk.

In the oil industry, waterflooding or water injection is where water is injected into the oil reservoir, to maintain the pressure, or to drive oil towards the wells, and thereby increase production. Water injection wells may be located on- and offshore, to increase oil recovery from an existing reservoir.

<span class="mw-page-title-main">Fire-tube boiler</span> Type of boiler

A fire-tube boiler is a type of boiler invented in 1828 by Mark Seguin, in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.

<span class="mw-page-title-main">Feedwater heater</span> Power plant component

A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler. Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system. This reduces plant operating costs and also helps to avoid thermal shock to the boiler metal when the feedwater is introduced back into the steam cycle.

<span class="mw-page-title-main">Hydronics</span> Use of liquid or gaseous water in heating or cooling systems

Hydronics is the use of liquid water or gaseous water (steam) or a water solution as heat-transfer medium in heating and cooling systems. The name differentiates such systems from oil and refrigerant systems.

<span class="mw-page-title-main">Thermal power station</span> Power plant that generates electricity from heat energy

A thermal power station is a type of power station in which heat energy is converted to electrical energy. In a steam-generating cycle heat is used to boil water in a large pressure vessel to produce high-pressure steam, which drives a steam turbine connected to an electrical generator. The low-pressure exhaust from the turbine enters a steam condenser where it is cooled to produce hot condensate which is recycled to the heating process to generate more high pressure steam. This is known as a Rankine cycle.

<span class="mw-page-title-main">Surface condenser</span> Steam engine component

A surface condenser is a water-cooled shell and tube heat exchanger installed to condense exhaust steam from a steam turbine in thermal power stations. These condensers are heat exchangers which convert steam from its gaseous to its liquid state at a pressure below atmospheric pressure. Where cooling water is in short supply, an air-cooled condenser is often used. An air-cooled condenser is however, significantly more expensive and cannot achieve as low a steam turbine exhaust pressure as a water-cooled surface condenser.

<span class="mw-page-title-main">Steam-electric power station</span>

The steam-electric power station is a power station in which the electric generator is steam driven. Water is heated, turns into steam and spins a steam turbine which drives an electrical generator. After it passes through the turbine, the steam is condensed in a condenser. The greatest variation in the design of steam-electric power plants is due to the different fuel sources.

Chemical fouling inhibitors are products that are mixtures of fouling and corrosion inhibitors use in boiler feedwater treatment. Several of these products use aliphatic polyamines to coat the surface of pipes.

A boiler feedwater pump is a specific type of pump used to pump feedwater into a steam boiler. The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.

<span class="mw-page-title-main">Boiler water</span>

Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam. The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.

<span class="mw-page-title-main">Franco-Crosti boiler</span>

The Franco–Crosti boiler is a type of boiler used for steam locomotives. It was designed in the 1930s by Attilio Franco and Dr Piero Crosti. The main difference between it and conventional feedwater heaters widely used on the continent is that the Franco-Crosti boiler uses both exhaust steam and exhaust gases from the firebox. Conventional feedwater heaters only use exhaust steam.

<span class="mw-page-title-main">Boiler feedwater</span>

Boiler feedwater is an essential part of boiler operations. The feed water is put into the steam drum from a feed pump. In the steam drum the feed water is then turned into steam from the heat. After the steam is used, it is then dumped to the main condenser. From the condenser, it is then pumped to the deaerated feed tank. From this tank it then goes back to the steam drum to complete its cycle. The feedwater is never open to the atmosphere. This cycle is known as a closed system or Rankine cycle.

The three primary objectives of nuclear reactor safety systems as defined by the U.S. Nuclear Regulatory Commission are to shut down the reactor, maintain it in a shutdown condition and prevent the release of radioactive material.

A deaerating feed tank (DFT), often found in steam plants that propel ships, is located after the main condensate pump and before the main feed booster pump. It has these three purposes:

  1. Remove dissolved oxygen (“air”) from the condensate
  2. Pre-heat the feedwater
  3. Provide a storage/surge volume

Boilers for generating steam or hot water have been designed in countless shapes, sizes and configurations. An extensive terminology has evolved to describe their common features. This glossary provides definitions for these terms.

<span class="mw-page-title-main">Evaporator (marine)</span> Fresh water production device

An evaporator, distiller or distilling apparatus is a piece of ship's equipment used to produce fresh drinking water from sea water by distillation. As fresh water is bulky, may spoil in storage, and is an essential supply for any long voyage, the ability to produce more fresh water in mid-ocean is important for any ship.

Steam and water analysis system (SWAS) is a system dedicated to the analysis of steam or water. In power stations, it is usually used to analyze boiler steam and water to ensure the water used to generate electricity is clean from impurities which can cause corrosion to any metallic surface, such as in boiler and turbine.

Oxygenated treatment (OT) is a technique used to reduce corrosion in a boiler and its associated feedwater system in flow-through boilers.

References

  1. "U.S. Department of Energy, Energy Efficiency & Renewable Energy, Advanced Manufacturing, Energy Tips: STEAM" (PDF). Energy.gov. January 2, 2012. Retrieved August 17, 2023.
  2. "Water Treatment Deaerators". Newterra. 2023-01-05. Retrieved 2023-08-17.
  3. 1 2 3 "The Deaerating Principle". Sterling Deaerator Company.
  4. 1 2 "Deaerators". Stork. Archived from the original on 2018-09-01. Retrieved 2016-09-30.
  5. 1 2 OSTI abstract. Retrieved April 23, 2021
  6. "The Wichita Star 26 May 1887, page 1". Newspapers.com. Retrieved 2023-08-17.
  7. "Iowa County Democrat 04 Mar 1881, page 2". Newspapers.com. Retrieved 2023-08-17.
  8. US664763A,Kleucker, George M.,"Method of deaerating water",issued 1900-12-25
  9. Carey, Stephen (2018-01-01). "Cold Starting the Titanic". Encyclopedia Titanica.
  10. D, Ryan (2016-08-26). "10 of the Best Boiler Feed Water Treatment Equipment Supply and Technology Companies". SAMCO Technologies. Retrieved 2023-08-17.
  11. "Montclair Times 01 Dec 1926, page 14". Newspapers.com. Retrieved 2023-08-17.
  12. "The News 16 May 1928, page 7". Newspapers.com. Retrieved 2023-08-17.
  13. "Vermont Tribune 13 Apr 1900, page 1". Newspapers.com. Retrieved 2023-08-17.
  14. US1914166A,Rohlin, Victor A.,"Apparatus for treating liquids",issued 1933-06-13
  15. US1596423A,Gibson, George H.,"Water-deaerating apparatus",issued 1926-08-17
  16. US1877412A,Lyon, Percy S.,"Deaerating water heater",issued 1932-09-13
  17. US1750035A,Stanley, Brown,"Deaerator",issued 1930-03-11
  18. "Intelligencer Journal 13 Feb 1958, page 42". Newspapers.com. Retrieved 2023-08-17.
  19. 1 2 US2204062A,Applebaum, Samuel B.,"Water deaerator and purifier",issued 1940-06-11
  20. "Deaerator working principle". Boilers Info.
  21. Standards and Typical Specifications for Tray Type Deaerators (10th ed.). Heat Exchange Institute. November 2016.
  22. "The Feedtank and Feedwater Conditioning". Spirax Sarco.
  23. Public Opinion, Chambersburg, PA, Feb 11, 1921. Retrieved Jan 25, 2022
  24. Palladium-Item, Richmond, Indiana, Sep 24, 1934. Retrieved Jan 25, 2022
  25. Union City Times-Gazette, Jul 23, 1940. Retrieved Jan 25, 2022
  26. Paterson Evening News, Paterson, NJ, Sep 12, 1956.Retrieved Jun 4, 2023
  27. STS Canada. Retrieved Mar 18, 2023
  28. Hielscher. Retrieved Mar 18, 2023
  29. Deaerator history. Retrieved Apr 24, 2021
  30. Vancouver Sun, Apr 14, 1962. Retrieved Jun 4, 2023
  31. US Dept of Energy, Deaerators in Industrial Steam Systems. Retrieved Mar 18, 2023
  32. AMPP, NACE RFP050-96, Standard Recommended Practice. Retrieved April 22, 2021
  33. The National Board of Boiler and Pressure Vessel Inspectors, April 1988. Retrieved April 22, 2021
  34. US Dept of Energy, CIBO paper dated Nov 1997. Retrieved April 23, 2021
  35. Proceedings of the American Power Conference paper, Otakar Jonas. Retrieved Jun 3, 2022
  36. Stickle History, Retrieved April 23, 2021
  37. Handbook, Chapter 14 Degasification. Retrieved April 23, 2021
  38. Court Case, 1929. Retrieved April 23, 2021
  39. The Guardian, Nov 2, 1951. Retrieved Mar 18, 2023
  40. Daily Mail, Feb 9, 1925. Retrieved Mar 18, 2023
  41. Perthshire Advertiser, Feb 27, 1909. Retrieved Mar 18, 2023
  42. Intellingencer Journal, Feb 13, 1958. Retrieved Mar 18, 2023
  43. Alliance Times-Herald, Mar 31, 1939. Retrieved Mar 18, 2023
  44. Chicago Tribune, Jul 15, 1949. Retrieved Mar 18, 2023
  45. News-Record, Aug 2, 1954. Retrieved Mar 18, 2023

Sources

Further reading