Electrometer

Last updated
Kolbe electrometer, precision form of gold-leaf instrument. This has a light pivoted aluminum vane hanging next to a vertical metal plate. When charged the vane is repelled by the plate and hangs at an angle. Elektrometr Kol'be.jpg
Kolbe electrometer, precision form of gold-leaf instrument. This has a light pivoted aluminum vane hanging next to a vertical metal plate. When charged the vane is repelled by the plate and hangs at an angle.

An electrometer is an electrical instrument for measuring electric charge or electrical potential difference. [1] There are many different types, ranging from historical handmade mechanical instruments to high-precision electronic devices. Modern electrometers based on vacuum tube or solid-state technology can be used to make voltage and charge measurements with very low leakage currents, down to 1 femtoampere. A simpler but related instrument, the electroscope, works on similar principles but only indicates the relative magnitudes of voltages or charges.

Contents

Historical electrometers

Gold-leaf electroscope

Gold-leaf electroscope Electroscope.png
Gold-leaf electroscope

The gold-leaf electroscope was one of the instruments used to indicate electric charge. [1] It is still used for science demonstrations but has been superseded in most applications by electronic measuring instruments. The instrument consists of two thin leaves of gold foil suspended from an electrode. When the electrode is charged by induction or by contact, the leaves acquire similar electric charges and repel each other due to the Coulomb force. Their separation is a direct indication of the net charge stored on them. On the glass opposite the leaves, pieces of tin foil may be pasted, so that when the leaves diverge fully they may discharge into the ground. The leaves may be enclosed in a glass envelope to protect them from drafts, and the envelope may be evacuated to minimize charge leakage. A further cause of charge leakage is ionizing radiation, so to prevent this, the electrometer must be surrounded by lead shielding.[ citation needed ] This principle has been used to detect ionizing radiation, as seen in the quartz fibre electrometer and Kearny fallout meter.

This type of electroscope usually acts as an indicator and not a measuring device, although it can be calibrated. A calibrated electrometer with a more robust aluminium indicator was invented by Ferdinand Braun and first described in 1887. According to Braun, the standard gold-leaf electrometer is good up to about 800 V with a resolution of 0.1 V using an ocular micrometer. For larger voltages up to 4–6 kV Braun's instrument can achieve a resolution of 10 V. [2] [3]

The instrument was developed in the 18th century by several researchers, among them Abraham Bennet (1787) [4] and Alessandro Volta.

Early quadrant electrometer

Early quadrant electrometer. Early Quadrant Electrometer.png
Early quadrant electrometer.

While the term "quadrant electrometer" eventually referred to Kelvin's version, this term was first used to describe a simpler device. [5] It consists of an upright stem of wood, to which is affixed to a semicircle of ivory. From the center there hangs a light cork ball upon a pivot. When the instrument is placed upon a charged body, the stem participates and repels the cork ball. The amount of repulsion may be read off the graduated semicircle, though the measured angle is not in direct proportion to the charge. Early inventors included William Henley (1770) and Horace-Bénédict de Saussure. [4]

Coulomb's electrometer

Coulomb electrometer Coulomb electrometer.png
Coulomb electrometer

Torsion is used to give a measurement more sensitive than repulsion of gold leaves or cork-balls. It consists of a glass cylinder with a glass tube on top. In the axes of the tube is a glass thread, the lower end of this holds a bar of gum lac, with a gilt pith ball at each extremity. Through another aperture on the cylinder, another gum lac rod with gilt balls may be introduced. This is called the carrier rod.

If the lower ball of the carrier rod is charged when it is entered into the aperture, this will repel one of the movable balls inside. An index and scale (not pictured) is attached to the top of the twistable glass rod. The number of degrees twisted to bring the balls back together is in exact proportion of the amount of charge of the ball of the carrier rod.

Francis Ronalds, the inaugural Director of the Kew Observatory, made important improvements to the Coulomb torsion balance around 1844 and the modified instrument was sold by London instrument-makers. [6] Ronalds used a thin suspended needle rather than the gum lac bar and replaced the carrier rod with a fixed piece in the plane of the needle. Both were metal, as was the suspending line and its surrounding tube, so that the needle and the fixed piece could be charged directly through wire connections. Ronalds also employed a Faraday cage and trialled photography to record the readings continuously. It was the forerunner of Kelvin's quadrant electrometer (described below).

Peltier electrometer

Developed by Peltier, this uses a form of magnetic compass to measure deflection by balancing the electrostatic force with a magnetic needle.

Bohnenberger electrometer

The Bohnenberger electrometer, developed by J. G. F. von Bohnenberger from an invention by T. G. B. Behrens, [1] consists of a single gold leaf suspended vertically between the anode and cathode of a dry pile. Any charge imparted to the gold leaf causes it to move toward one or the other pole; thus, the sign of the charge as well as its approximate magnitude may be gauged. [7]

Attraction electrometer

Also known as "attracted disk electrometers", [1] attraction electrometers are sensitive balances measuring the attraction between charged disks. William Snow Harris is credited with the invention of this instrument, which was further improved by Lord Kelvin.

Kelvin's quadrant electrometer

Lord Kelvin's Quadrant Electrometer Lord Kelvin quadrant electrometer engraving.jpg
Lord Kelvin's Quadrant Electrometer

Developed by Lord Kelvin, this is the most sensitive and accurate of all the mechanical electrometers. The original design uses a light aluminum sector suspended inside a drum cut into four segments. The segments are insulated and connected diagonally in pairs. The charged aluminum sector is attracted to one pair of segments and repelled from the other. The deflection is observed by a beam of light reflected from a small mirror attached to the sector, just as in a galvanometer. The engraving on the right shows a slightly different form of this electrometer, using four flat plates rather than closed segments. The plates can be connected externally in the conventional diagonal way (as shown), or in a different order for specific applications.

A more sensitive form of quadrant electrometer was developed by Frederick Lindemann. It employs a metal-coated quartz fiber instead of an aluminum sector. The deflection is measured by observing the movement of the fiber under a microscope. Initially used for measuring star light,[ citation needed ] it was employed for the infrared detection[ citation needed ] of airplanes in the early stages of World War II.

Some mechanical electrometers were housed inside a cage often referred to as a “bird cage”. This is a form of Faraday Cage that protected the instrument from external electrostatic charges.

Electrograph

Electricity readings may be recorded continuously with a device known as an electrograph. Francis Ronalds created an early electrograph around 1814 in which the changing electricity made a pattern in a rotating resin-coated plate. It was employed at Kew Observatory and the Royal Observatory, Greenwich in the 1840s to create records of variations in atmospheric electricity. [6] In 1845, Ronalds invented photographic means of registering the atmospheric electricity. The photosensitive surface was pulled slowly past of the aperture diaphragm of the camera box, which also housed an electrometer, and captured ongoing movements of the electrometer indices as a trace. [8] Kelvin used similar photographic means for his quadrant electrometer (see above) in the 1860s.

Modern electrometers

A modern electrometer is a highly sensitive electronic voltmeter whose input impedance is so high that the current flowing into it can be considered, for most practical purposes, to be zero. The actual value of input resistance for modern electronic electrometers is around 1014Ω, compared to around 1010Ω for nanovoltmeters. [9] Owing to the extremely high input impedance, special design considerations (such as driven shields and special insulation materials) must be applied to avoid leakage current.

Among other applications, electrometers are used in nuclear physics experiments as they are able to measure the tiny charges left in matter by the passage of ionizing radiation. The most common use for modern electrometers is the measurement of radiation with ionization chambers, in instruments such as geiger counters.[ citation needed ]

Vibrating reed electrometers

Vibrating reed electrometers use a variable capacitor formed between a moving electrode (in the form of a vibrating reed) and a fixed input electrode. As the distance between the two electrodes varies, the capacitance also varies and electric charge is forced in and out of the capacitor. The alternating current signal produced by the flow of this charge is amplified and used as an analogue for the DC voltage applied to the capacitor. The DC input resistance of the electrometer is determined solely by the leakage resistance of the capacitor, and is typically extremely high, (although its AC input impedance is lower).

For convenience of use, the vibrating reed assembly is often attached by a cable to the rest of the electrometer. This allows for a relatively small unit to be located near the charge to be measured while the much larger reed-driver and amplifier unit can be located wherever it is convenient for the operator. [10]

Valve electrometers

Valve electrometers use a specialized vacuum tube (thermionic valve) with a very high gain (transconductance) and input resistance. The input current is allowed to flow into the high impedance grid, and the voltage so generated is vastly amplified in the anode (plate) circuit. Valves designed for electrometer use have leakage currents as low as a few femtoamperes (10−15 amperes). Such valves must be handled with gloved hands as the salts left on the glass envelope can provide leakage paths for these tiny currents. [11]

In a specialized circuit called inverted triode, the roles of anode and grid are reversed. This places the control electrode at a maximum distance from the space-charge region surrounding the filament, minimizing the number of electrons collected by the control electrode, and thus minimizing the input current. [12]

Solid-state electrometers

The most modern electrometers consist of a solid state amplifier using one or more field-effect transistors, connections for external measurement devices, and usually a display and/or data-logging connections. The amplifier amplifies small currents so that they are more easily measured. The external connections are usually of a co-axial or tri-axial design, and allow attachment of diodes or ionization chambers for ionising radiation measurement. The display or data-logging connections allow the user to see the data or record it for later analysis. Electrometers designed for use with ionization chambers may include a high-voltage power supply, which is used to bias the ionization chamber.

Solid-state electrometers are often multipurpose devices that can measure voltage, charge, resistance and current. They measure voltage by means of "voltage balancing", in which the input voltage is compared with an internal reference voltage source using an electronic circuit with a very high input impedance (of the order of 1014 Ω). A similar circuit modified to act as a current-to-voltage converter enables the instrument to measure currents as small as a few femtoamperes. Combined with an internal voltage source, the current measuring mode can be adapted to measure very high resistances, of the order of 1017 Ω. Finally, by calculation from the known capacitance of the electrometer's input terminal, the instrument can measure very small electric charges, down to a small fraction of a picocoulomb.

See also

Related Research Articles

<span class="mw-page-title-main">Voltmeter</span> Instrument used for measuring voltage

A voltmeter is an instrument used for measuring electric potential difference between two points in an electric circuit. It is connected in parallel. It usually has a high resistance so that it takes negligible current from the circuit.

<span class="mw-page-title-main">Multimeter</span> Electronic measuring instrument that combines several measurement functions in one unit

A multimeter is a measuring instrument that can measure multiple electrical properties. A typical multimeter can measure voltage, resistance, and current, in which case can be used as a voltmeter, ohmmeter, and ammeter. Some feature the measurement of additional properties such as temperature and capacitance.

<span class="mw-page-title-main">Ground (electricity)</span> Reference point in an electrical circuit from which voltages are measured

In electrical engineering, ground or earth may be a reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.

<span class="mw-page-title-main">Capacitance</span> Ability of a body to store an electrical charge

Capacitance is the capability of a material object or device to store electric charge. It is measured by the charge in response to a difference in electric potential, expressed as the ratio of those quantities. Commonly recognized are two closely related notions of capacitance: self capacitance and mutual capacitance. An object that can be electrically charged exhibits self capacitance, for which the electric potential is measured between the object and ground. Mutual capacitance is measured between two components, and is particularly important in the operation of the capacitor, an elementary linear electronic component designed to add capacitance to an electric circuit.

<span class="mw-page-title-main">Flashtube</span> Incoherent light source

A flashtube (flashlamp) is an electric arc lamp designed to produce extremely intense, incoherent, full-spectrum white light for a very short time. A flashtube is a glass tube with an electrode at each end and is filled with a gas that, when triggered, ionizes and conducts a high-voltage pulse to make light. Flashtubes are used most in photography; they also are used in science, medicine, industry, and entertainment.

In electronics, a voltage divider (also known as a potential divider) is a passive linear circuit that produces an output voltage (Vout) that is a fraction of its input voltage (Vin). Voltage division is the result of distributing the input voltage among the components of the divider. A simple example of a voltage divider is two resistors connected in series, with the input voltage applied across the resistor pair and the output voltage emerging from the connection between them.

<span class="mw-page-title-main">Electroscope</span> Early scientific instrument to detect charge

The electroscope is an early scientific instrument used to detect the presence of electric charge on a body. It detects charge by the movement of a test object due to the Coulomb electrostatic force on it. The amount of charge on an object is proportional to its voltage. The accumulation of enough charge to detect with an electroscope requires hundreds or thousands of volts, so electroscopes are used with high voltage sources such as static electricity and electrostatic machines. An electroscope can only give a rough indication of the quantity of charge; an instrument that measures electric charge quantitatively is called an electrometer.

<span class="mw-page-title-main">Internal resistance</span> Impedance of a linear circuits Thévenin representation

In electrical engineering, a practical electric power source which is a linear circuit may, according to Thévenin's theorem, be represented as an ideal voltage source in series with an impedance. This impedance is termed the internal resistance of the source. When the power source delivers current, the measured voltage output is lower than the no-load voltage; the difference is the voltage drop caused by the internal resistance. The concept of internal resistance applies to all kinds of electrical sources and is useful for analyzing many types of circuits.

The ionization chamber is the simplest type of gaseous ionisation detector, and is widely used for the detection and measurement of many types of ionizing radiation, including X-rays, gamma rays, alpha particles and beta particles. Conventionally, the term "ionization chamber" refers exclusively to those detectors which collect all the charges created by direct ionization within the gas through the application of an electric field. It uses the discrete charges created by each interaction between the incident radiation and the gas to produce an output in the form of a small direct current. This means individual ionising events cannot be measured, so the energy of different types of radiation cannot be differentiated, but it gives a very good measurement of overall ionising effect.

<span class="mw-page-title-main">Electrostatic generator</span> Device that generates electrical charge on a high voltage electrode

An electrostatic generator, or electrostatic machine, is an electrical generator that produces static electricity, or electricity at high voltage and low continuous current. The knowledge of static electricity dates back to the earliest civilizations, but for millennia it remained merely an interesting and mystifying phenomenon, without a theory to explain its behavior and often confused with magnetism. By the end of the 17th century, researchers had developed practical means of generating electricity by friction, but the development of electrostatic machines did not begin in earnest until the 18th century, when they became fundamental instruments in the studies about the new science of electricity.

<span class="mw-page-title-main">Capacitor types</span> Manufacturing styles of an electronic device

Capacitors are manufactured in many styles, forms, dimensions, and from a large variety of materials. They all contain at least two electrical conductors, called plates, separated by an insulating layer (dielectric). Capacitors are widely used as parts of electrical circuits in many common electrical devices.

<span class="mw-page-title-main">Charge amplifier</span>

A charge amplifier is an electronic current integrator that produces a voltage output proportional to the integrated value of the input current, or the total charge injected.

Electrochemistry, a branch of chemistry, went through several changes during its evolution from early principles related to magnets in the early 16th and 17th centuries, to complex theories involving conductivity, electric charge and mathematical methods. The term electrochemistry was used to describe electrical phenomena in the late 19th and 20th centuries. In recent decades, electrochemistry has become an area of current research, including research in batteries and fuel cells, preventing corrosion of metals, the use of electrochemical cells to remove refractory organics and similar contaminants in wastewater electrocoagulation and improving techniques in refining chemicals with electrolysis and electrophoresis.

<span class="mw-page-title-main">Capacitor</span> Passive two-terminal electronic component that stores electrical energy in an electric field

In electrical engineering, a capacitor is a device that stores electrical energy by accumulating electric charges on two closely spaced surfaces that are insulated from each other. The capacitor was originally known as the condenser, a term still encountered in a few compound names, such as the condenser microphone. It is a passive electronic component with two terminals.

<span class="mw-page-title-main">Capacitance meter</span> Type of electronic test equipment

A capacitance meter is a piece of electronic test equipment used to measure capacitance, mainly of discrete capacitors. Depending on the sophistication of the meter, it may display the capacitance only, or it may also measure a number of other parameters such as leakage, equivalent series resistance (ESR), and inductance. For most purposes and in most cases the capacitor must be disconnected from circuit; ESR can usually be measured in circuit.

<span class="mw-page-title-main">Test probe</span>

A test probe is a physical device used to connect electronic test equipment to a device under test (DUT). Test probes range from very simple, robust devices to complex probes that are sophisticated, expensive, and fragile. Specific types include test prods, oscilloscope probes and current probes. A test probe is often supplied as a test lead, which includes the probe, cable and terminating connector.

In the field of electronics, a technique where part of the output of a system is used at startup can be described as bootstrapping.

<span class="mw-page-title-main">Four-terminal sensing</span> Method of measuring electrical impedance

In electrical engineering, four-terminal sensing, 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements than the simpler and more usual two-terminal (2T) sensing. Four-terminal sensing is used in some ohmmeters and impedance analyzers, and in wiring for strain gauges and resistance thermometers. Four-point probes are also used to measure sheet resistance of thin films.

<span class="mw-page-title-main">LCR meter</span> Electronic test equipment that measures inductance, capacitance, and resistance

An LCR meter is a type of electronic test equipment used to measure the inductance (L), capacitance (C), and resistance (R) of an electronic component. In the simpler versions of this instrument the impedance was measured internally and converted for display to the corresponding capacitance or inductance value. Readings should be reasonably accurate if the capacitor or inductor device under test does not have a significant resistive component of impedance. More advanced designs measure true inductance or capacitance, as well as the equivalent series resistance of capacitors and the Q factor of inductive components.

<span class="mw-page-title-main">Quartz fiber dosimeter</span> Type of radiation dosimeter

A quartz fiber dosimeter, sometimes called a self indicating pocket dosimeter (SIPD) or self reading pocket dosimeter (SRPD) or quartz fibre electrometer (QFE), is a type of radiation dosimeter, a pen-like device that measures the cumulative dose of ionizing radiation received by the device, usually over one work period. It is clipped to a person's clothing, normally a breast pocket for whole body exposure, to measure the user's exposure to radiation.

References

  1. 1 2 3 4 Fleming, John Ambrose (1911). "Electrometer"  . In Chisholm, Hugh (ed.). Encyclopædia Britannica . Vol. 9 (11th ed.). Cambridge University Press. pp. 234–237.
  2. Ferdinand Braun, "Ueber das electrische Verhalten des Steinsalzes", Annalen der Physik, vol. 31, pp. 855–872, 1887.
  3. "Braun Electroscope (early 1900s)", ORAU Museum of Radiation and Radiology, retrieved 20 September 2021.
  4. 1 2 Baigrie, Brian (2007). Electricity and magnetism: A historical perspective. Westport, CT: Greenwood Press. p. 33.
  5. Draper, John William (1861). A textbook on chemistry. New York: Harper and sons. p.  119. john william draper textbook on chemistry.
  6. 1 2 Ronalds, B.F. (2016). Sir Francis Ronalds: Father of the Electric Telegraph. London: Imperial College Press. ISBN   978-1-78326-917-4.
  7. John Angell (1877). Elements of magnetism and electricity: with practical instructions for the performance of experiments, and the construction of cheap apparatus. W. Collins, Sons, & Co. pp. 169–. Retrieved 26 May 2013.
  8. Ronalds, B.F. (2016). "The Beginnings of Continuous Scientific Recording using Photography: Sir Francis Ronalds' Contribution". European Society for the History of Photography. Retrieved 2 June 2016.
  9. Keithley, Making precision low current and high resistance measurements, "A greater measure of confidence" brochure, 2011, page 8
  10. XL7900 Vibrating capacitor data sheet
  11. "CK5889 Electrometer pentode data sheet" (PDF). Archived from the original (PDF) on 2016-09-20. Retrieved 2016-08-29.
  12. Inverted Triode for Industrial Measurements, Manual of Industrial Circuits Electronics. Electronics. December 1944. p. 176.