This article needs additional citations for verification .(May 2023) |
An infinite switch, simmerstat, energy regulator or infinite controller is a type of switch that allows variable power output of a heating element of an electric stove. It is called "infinite" because its average output is infinitely variable rather than being limited to a few switched levels. It uses a bi-metallic strip conductive connection across terminals that disconnects with increased temperature. As current passes through the bimetal connection, it will heat and deform, breaking the connection and turning off the power. After a short time, the bimetal will cool and reconnect. Infinite switches vary the average power delivered to a device by switching frequently between on and off states. [1] They may be used for situations that are not sensitive to such changes, such as the resistive heating elements in electric stoves and kilns.
An early switch operating by this principle was invented by Chester I. Hall of the General Electric Company, with a patent filed in 1921 and approved in 1924. Like the modern infinite switch, Hall's invention used a bi-metallic strip, heated by a constant current, to break a connection after a given period of time. It also used a rotatable cam attached to a knob to control duration. However, unlike its successors, Hall's invention was not self-resetting and would only stay on for a single cycle, after which a manual reset button could be pressed. According to the patent, the intended use was to control the timing of exposures in medical radiography. [2]
The infinite switch itself was described in a 1975 patent of George F. Esker Jr. and Otto J. Cousins of the Harper Wyman Company. This switch would reset itself as the bi-metallic strip cooled, provided a cycle of calibrated opening and closing. It also provided an indicator light that remained on as long as the knob was not in the closed position. This switch was designed for use in electric stoves. [3]
A rotary hand control turns a shaft that is connected within the infinite switch to a cam and follower. At the off position both power line connections are interrupted. At all on positions the manual contacts connect one of the line terminals to the pilot lamp terminal and one of the terminals for the heating element being controlled. At the maximum heat position the cam follower applies sufficient force for the cycling contacts to remain closed at all times. At the other positions the cam follower applies less force allowing the cycling contacts to cycle. Initially, the cycling contacts close in all positions and a permanent magnet pulls them to remain closed. One of the two cycling contacts energizes the controlled heating element and the other energizes a very small electric heating element attached to a bimetallic strip. The force from the heated bimetallic strip increases as its temperature rises until it overcomes the combined force from the cam follower, an unheated bimetallic strip that compensates for ambient temperature, and the permanent magnet allowing the cycling contacts open which interrupts the electric current to both heating elements. Both the bimetallic strip and the "burner" begin to cool. Eventually the heated bimetallic strip will no longer have enough force to overcome the force from the cam follower and the unheated bimetallic strip. As the contacts approach each other the permanent magnet attracts the contact beam rapidly closing the contacts and the cycle repeats. [4]
Controls for domestic cooking generally have a 5% on time at the minimum setting. Controls for commercial cooking generally have a 22.5% on time at the minimum setting. Controls for warming trays, kilns and other applications may have a higher minimum setting to provide fine control over a range useful for the application.[ citation needed ]
An important variation of the control is the series or current sensitive type as opposed to the parallel or voltage sensitive type. The difference between the types is whether the internal heater within the infinite switch becomes connected in series with the controlled heating element, that is to one power line terminal and the controlled heating element terminal or it becomes connected to the two power line terminals. The preceding discussion referring to two cycling contacts presumes the parallel or voltage sensitive type. The current sensitive type has the effect of compensating the control for the temperature of the controlled heating element because the resistance of nickel chromium heating elements changes significantly with temperature. When cool the heating element has a lower resistance and dissipates more power than it does when hot. This has the effect of shrinking the range of power delivered by the voltage sensitive type when the heating element is cooled, by a vessel containing water for example. The current sensitive type makes it easier to control the rate at which a pot boils. The current sensitive type is specific to nominal current of the heating element being controlled and can't be used for applications that allow the power rating of the heating element to be changed for different cooking tasks.[ citation needed ]
Disadvantages of frequently cycled mechanical contacts may include erosion of the switch contacts if the contacts move slowly by design or due to contamination so that power from electrical arcing between closely spaced contacts has time to accumulate and overheat or melt the contact surface. Operating the device contacts at low current to control a relay to preserve the contacts from thermal damage causes rapid failure as condensed volatile organic compounds, more familiarly known as kitchen grease, accumulate and insulate the contacts. The pulse of radio frequency noise emitted by any electrical arc is contained within the metal enclosure required for a safe design in the event of a component or wire insulation failure. The mechanical contact infinite switch is unsuitable for resistive loads more than 15 A at 240 V or 3.6 kW. The contacts have a reduced operating life when used for inductive loads like electric motors or induction heating.[ citation needed ]
The infinite switch is comparable to a slow pulse-width modulation device, but both the duty cycle and the cycle rate vary. The device is also conceptually similar to a bimetallic switching thermostat, except that the infinite switch responds to the temperature of its internal heater as a model for the temperature of the "burner" being controlled instead of sensing the temperature being controlled directly.[ citation needed ]
A relay is an electrically operated switch. It consists of a set of input terminals for a single or multiple control signals, and a set of operating contact terminals. The switch may have any number of contacts in multiple contact forms, such as make contacts, break contacts, or combinations thereof.
A soldering iron is a hand tool used in soldering. It supplies heat to melt solder so that it can flow into the joint between two workpieces.
In electrical engineering, a switch is an electrical component that can disconnect or connect the conducting path in an electrical circuit, interrupting the electric current or diverting it from one conductor to another. The most common type of switch is an electromechanical device consisting of one or more sets of movable electrical contacts connected to external circuits. When a pair of contacts is touching current can pass between them, while when the contacts are separated no current can flow.
An alternators is an electrical generator that converts mechanical energy to electrical energy in the form of alternating current. For reasons of cost and simplicity, most alternators use a rotating magnetic field with a stationary armature. Occasionally, a linear alternator or a rotating armature with a stationary magnetic field is used. In principle, any AC electrical generator can be called an alternator, but usually the term refers to small rotating machines driven by automotive and other internal combustion engines.
A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by current in excess of that which the equipment can safely carry (overcurrent). Its basic function is to interrupt current flow to protect equipment and to prevent fire. Unlike a fuse, which operates once and then must be replaced, a circuit breaker can be reset to resume normal operation.
A thermostat is a regulating device component which senses the temperature of a physical system and performs actions so that the system's temperature is maintained near a desired setpoint.
A cam timer or drum sequencer is an electromechanical system for controlling a sequence of events automatically. It resembles a music box with movable pins, controlling electrical switches instead of musical notes.
A timer or countdown timer is a type of clock that starts from a specified time duration and stops when reaching 00:00. A simple timer is an hourglass. Commonly, a timer triggers an alarm when it ends. A timer can be implemented through hardware or software. Stopwatches operate in the opposite direction, downwards from 00:00, measuring elapsed time since a given time instant. Time switches are timers that control an electric switch.
A bimetallic strip or bimetal strip is a strip that consists of two strips of different metals which expand at different rates as they are heated. They are used to convert a temperature change into mechanical displacement. The different expansions force the flat strip to bend one way if heated, and in the opposite direction if cooled below its initial temperature. The metal with the higher coefficient of thermal expansion is on the outer side of the curve when the strip is heated and on the inner side when cooled.
A motor controller is a device or group of devices that can coordinate in a predetermined manner the performance of an electric motor. A motor controller might include a manual or automatic means for starting and stopping the motor, selecting forward or reverse rotation, selecting and regulating the speed, regulating or limiting the torque, and protecting against overloads and electrical faults. Motor controllers may use electromechanical switching, or may use power electronics devices to regulate the speed and direction of a motor.
In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby stopping or interrupting the current. It is a sacrificial device; once a fuse has operated, it is an open circuit, and must be replaced or rewired, depending on its type.
A kettle, sometimes called a tea kettle or teakettle, is a device specialized for boiling water, commonly with a lid, spout, and handle. There are two main types: the stovetop kettle, which uses heat from a hob, and the electric kettle, which is a small kitchen appliance with an internal heating element.
Induction cooking is performed using direct electrical induction heating of cooking vessels, rather than relying on indirect radiation, convection, or thermal conduction. Induction cooking allows high power and very rapid increases in temperature to be achieved: changes in heat settings are instantaneous.
An electronic component is any basic discrete electronic device or physical entity part of an electronic system used to affect electrons or their associated fields. Electronic components are mostly industrial products, available in a singular form and are not to be confused with electrical elements, which are conceptual abstractions representing idealized electronic components and elements. A datasheet for an electronic component is a technical document that provides detailed information about the component's specifications, characteristics, and performance.
A fan heater, also called a blow heater, is a heater that works by using a fan to pass air over a heat source. This heats up the air, which then leaves the heater, warming up the surrounding room. They can heat an enclosed space such as a room faster than a heater without a fan, but like any fan, create a degree of noise.
A thermal cutoff is an electrical safety device that interrupts electric current when heated to a specific temperature. These devices may be for one-time use, or may be reset manually or automatically.
A convection heater, also known as a convector heater, is a type of heater that utilizes convection currents to heat and circulate air. These currents move through the appliance and across its heating element, using thermal conduction to warm the air and decrease its density relative to colder air, causing it to rise.
A glow switch starter or glowbottle starter is a type of preheat starter used with a fluorescent lamp. It is commonly filled with neon gas or argon gas and typically contains a bimetallic strip and a stationary electrode. The operating principle is simple, when current is applied, the gas inside ionizes and heats a bimetallic strip which in turn bends toward the stationary electrode thus shorting the starter between the electrodes of the fluorescent lamp. After about a second the starter's bimetallic strip cools and opens the circuit between the electrodes, and the process repeats until the lamp has lit. One disadvantage of glow switch starters is that when the lamp is at the end of its life it will continuously blink on and off until the glow switch starter wears out or an electrode on the fluorescent lamp burns out. Glow starters have a relatively short life, and light fittings enable the starter to be changed easily. Electronic starters, being interchangeable and using the same casing as a glow starter, last for many years.
Overheating is a phenomenon of rising temperatures in an electrical circuit. Overheating causes damage to the circuit components and can cause fire, explosion, and injury. Damage caused by overheating is usually irreversible; the only way to repair it is to replace some components.
This glossary of electrical and electronics engineering is a list of definitions of terms and concepts related specifically to electrical engineering and electronics engineering. For terms related to engineering in general, see Glossary of engineering.