This article needs additional citations for verification .(March 2012) |
Thermowells are cylindrical fittings used to protect temperature sensors installed to monitor industrial processes. A thermowell consists of a tube closed at one end and mounted on the wall of the piping or vessel within which the fluid of interest flows. A temperature sensor, such as a thermometer, thermocouple, or resistance temperature detector, is inserted in the open end of the tube, which is usually in the open air outside the piping or vessel and any thermal insulation.
Thermodynamically, the process fluid transfers heat to the thermowell wall, which in turn transfers heat to the sensor. Since more mass is present with a sensor-well assembly than with a probe directly immersed into the fluid, the sensor's response to changes in temperature is slowed by the addition of the well. If the sensor fails, it can be easily replaced without draining the vessel or piping. Since the mass of the thermowell must be heated to the fluid temperature, and since the walls of the thermowell conduct heat out of the process, sensor accuracy and responsiveness is reduced by the addition of a thermowell. [1]
Traditionally, the thermowell length has been based in the degree of insertion relative to pipe wall diameter. This tradition is misplaced as it can expose the thermowell to the risk of flow-induced vibration and fatigue failure. When measurement error calculations are carried out for the installation, for insulated piping or near-ambient fluid temperatures, excluding thermal radiation effects, conduction error is less than one percent as long as the tip is exposed to flow, even in flanged mounted installations. Arguments for longer designs are based on traditional notions but rarely justified. Long thermowells may be used in low velocity services or in cases where historical experience justified their use. In modern high-strength piping and elevated fluid velocities, each installation must be carefully examined especially in cases where acoustic resonances in the process are involved.
The response time of the installed sensor is largely governed by the fluid velocity and considerably greater than the response time of the sensor itself. This is the result of the thermal mass of the thermowell tip, and the heat transfer coefficient between the thermowell and the fluid.
A representative thermowell is machined from drilled bar stock to ensure a proper sensor fit (ex: an 0.260-inch bore matching an 0.250-inch sensor). A thermowell is typically mounted into the process stream by way of a threaded, welded, sanitary cap, or flanged process connection. The temperature sensor is inserted in the open end of the thermowell and typically spring-loaded to ensure that the outside tip of the temperature sensor is in metal to metal contact with the inside tip of the thermowell. The use of welded sections for long designs is discouraged due to corrosion and fatigue risks.
The thermowell protects the instrument from the pressure, flow-induced forces, and chemical effects of the process fluid. Typically a thermowell is made from metal bar stock. The end of the thermowell may be of reduced diameter (as is the case with a tapered or stepped-shank thermowell) to improve the speed of response.
For low pressures and temperatures, Teflon may be used to make a thermowell; various types of stainless steel are typical, with other metals used for highly corrosive process fluids.
Where temperatures are high and the pressure differential is small, a protection tube may be used with a bare thermocouple element. These are often made of alumina or other ceramic material to prevent chemical attack of the platinum or other thermocouple elements. The ceramic protection tube may be inserted into a heavy outer protection tube manufactured from silicon carbide or other material where increased protection is required.
Thermowells are typically installed in piping systems and subject to both hydrostatic and aerodynamic forces. Vortex shedding is the dominant concern for thermowells in cross-flow applications and is capable of forcing the thermowell into resonance with the possibility of fatigue failure not only of the thermowell but also of the temperature sensor. The conditions for flow-induced resonance generally govern the design of the thermowell apart from its pressure rating and materials of construction. Flow-induced motion of the thermowell occurs both in-line with and transverse to the direction of flow with the fluid forces acting to bend the thermowell. In many applications the transverse component of the fluid forces resulting from vortex shedding tends to govern the onset of flow-induced resonance, with a forcing frequency equal to the vortex shedding rate. In liquids and in high-pressure compressible fluids, a smaller but nonetheless significant component of motion in the flow-direction is also present and occurs at nearly twice the vortex shedding rate. The in-line resonance condition may govern thermowell design at high fluid velocities although its amplitude is a function of the mass-damping parameter or Scruton number describing the thermowell-fluid interaction.
The aerodynamic force coefficients and the dependence of the shedding rate are dependent on the so-called tip Reynolds number. for Reynolds numbers less than 100000 (the Critical Reynolds Number), the shedding forces are well behaved and lead to periodic forcing. For Reynolds Numbers associated with the Drag Crisis (first reported by Gustav Eiffel) 100,000 < Rd < 1,000,000-3,000,000, the shedding forces are randomized with a corresponding reduction in magnitude. The random fluctuations are characterized by their Fourier Spectra characterized by its Strouhal Bandwidth and the root mean square magnitudes of the aerodynamic force coefficients in the lift and drag directions.
For drilled bar-stock thermowells, the most common form of failure is bending fatigue at its base where the bending stresses are greatest. In extreme flow conditions (high-velocity liquids or high-velocity, high-pressure gases and vapors) catastrophic failure may occur with bending stresses exceeding the ultimate strength of the material. For extremely long thermowells, the static component of the bending stresses may govern design. In less demanding services, fatigue failure is more gradual and often preceded by a series sensor failures. The latter are due to the acceleration of the thermowell tip as it vibrates, this motion causes the element to lift off the bottom of the thermowell and batter itself to pieces. In cases where the acceleration stresses have been measured, sensor accelerations at resonant conditions often exceed 250 g and have destroyed the accelerometer.
The natural frequencies of thermowell bending modes are dependent upon the dimensions of the thermowell, the compliance (or flexibility) of its support, and to a lesser extent dependent upon the mass of the sensor and the added mass of the fluid surrounding the thermowell.
The ASME Performance Test Code PTC 19.3TW-2016 ("19.3TW") defines criteria for the design and application of rigidly supported thermowells. However, these thermowells must be manufactured from bar stock or forged material where certain dimensional requirements and manufacturing tolerances are met. Coatings, sleeves, velocity collars, and special machined surfaces such as spirals or fins are expressly outside the scope of the 19.3TW standard. [2]
Catastrophic failure of a thermowell due to fatigue caused the 1995 sodium leak and fire at the Monju Nuclear Power Plant in Japan. Other failures are documented in the published literature.
The ASME PTC 19.3 TW (2016) Thermowells Standard is a widely used code for thermowells machined from bar stock and includes those welded to or threaded into a flange as well as those welded into a process vessel or pipe with or without a weld adaptor, but does not account for pipe wall flexibility or ovalization.
A viscometer is an instrument used to measure the viscosity of a fluid. For liquids with viscosities which vary with flow conditions, an instrument called a rheometer is used. Thus, a rheometer can be considered as a special type of viscometer. Viscometers can measure only constant viscosity, that is, viscosity that does not change with flow conditions.
In fluid dynamics, a vortex is a region in a fluid in which the flow revolves around an axis line, which may be straight or curved. Vortices form in stirred fluids, and may be observed in smoke rings, whirlpools in the wake of a boat, and the winds surrounding a tropical cyclone, tornado or dust devil.
A boiler is a closed vessel in which fluid is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, including water heating, central heating, boiler-based power generation, cooking, and sanitation.
Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below:
Shear stress is the component of stress coplanar with a material cross section. It arises from the shear force, the component of force vector parallel to the material cross section. Normal stress, on the other hand, arises from the force vector component perpendicular to the material cross section on which it acts.
The vortex tube, also known as the Ranque-Hilsch vortex tube, is a mechanical device that separates a compressed gas into hot and cold streams. The gas emerging from the hot end can reach temperatures of 200 °C (390 °F), and the gas emerging from the cold end can reach −50 °C (−60 °F). It has no moving parts and is considered an environmentally friendly technology because it can work solely on compressed air and does not use Freon. Its efficiency is low, however, counteracting its other environmental advantages.
In fluid dynamics, a Kármán vortex street is a repeating pattern of swirling vortices, caused by a process known as vortex shedding, which is responsible for the unsteady separation of flow of a fluid around blunt bodies.
In fluid dynamics, vortex shedding is an oscillating flow that takes place when a fluid such as air or water flows past a bluff body at certain velocities, depending on the size and shape of the body. In this flow, vortices are created at the back of the body and detach periodically from either side of the body forming a Kármán vortex street. The fluid flow past the object creates alternating low-pressure vortices on the downstream side of the object. The object will tend to move toward the low-pressure zone.
Temperature measurement describes the process of measuring a current temperature for immediate or later evaluation. Datasets consisting of repeated standardized measurements can be used to assess temperature trends.
In fluid dynamics, vortex-induced vibrations (VIV) are motions induced on bodies interacting with an external fluid flow, produced by, or the motion producing, periodic irregularities on this flow.
In fluid dynamics, flow separation or boundary layer separation is the detachment of a boundary layer from a surface into a wake.
The term friction loss has a number of different meanings, depending on its context.
The Kutta–Joukowski theorem is a fundamental theorem in aerodynamics used for the calculation of lift of an airfoil translating in a uniform fluid at a constant speed so large that the flow seen in the body-fixed frame is steady and unseparated. The theorem relates the lift generated by an airfoil to the speed of the airfoil through the fluid, the density of the fluid and the circulation around the airfoil. The circulation is defined as the line integral around a closed loop enclosing the airfoil of the component of the velocity of the fluid tangent to the loop. It is named after Martin Kutta and Nikolai Zhukovsky who first developed its key ideas in the early 20th century. Kutta–Joukowski theorem is an inviscid theory, but it is a good approximation for real viscous flow in typical aerodynamic applications.
In fluid dynamics, drag crisis is a phenomenon in which drag coefficient drops off suddenly as Reynolds number increases. This has been well studied for round bodies like spheres and cylinders. The drag coefficient of a sphere will change rapidly from about 0.5 to 0.2 at a Reynolds number in the range of 300000. This corresponds to the point where the flow pattern changes, leaving a narrower turbulent wake. The behavior is highly dependent on small differences in the condition of the surface of the sphere.
Instrumentation is used to monitor and control the process plant in the oil, gas and petrochemical industries. Instrumentation ensures that the plant operates within defined parameters to produce materials of consistent quality and within the required specifications. It also ensures that the plant is operated safely and acts to correct out of tolerance operation and to automatically shut down the plant to prevent hazardous conditions from occurring. Instrumentation comprises sensor elements, signal transmitters, controllers, indicators and alarms, actuated valves, logic circuits and operator interfaces.
A pipe support or pipe hanger is a designed element that transfer the load from a pipe to the supporting structures. The load includes the weight of the pipe proper, the content that the pipe carries, all the pipe fittings attached to pipe, and the pipe covering such as insulation. The four main functions of a pipe support are to anchor, guide, absorb shock, and support a specified load. Pipe supports used in high or low temperature applications may contain insulation materials. The overall design configuration of a pipe support assembly is dependent on the loading and operating conditions.
Vortex flowmeter is a flowmeter for measuring fluid flow rates in an enclosed conduit.
A whistle is a device that makes sound from air blown from one end forced through a small opening at the opposite end. They are shaped in a way that allows air to oscillate inside of a chamber in an unstable way. The physical theory of the sound-making process is an example of the application of fluid dynamics or hydrodynamics and aerodynamics. The principles relevant to whistle operation also have applications in other areas, such as fluid flow measurement.
Post weld heat treatment (PWHT) is a controlled process in which a material that has been welded is reheated to a temperature below its lower critical transformation temperature, and then it is held at that temperature for a specified amount of time. It is often referred to as being any heat treatment performed after welding; however, within the oil, gas, petrochemical and nuclear industries, it has a specific meaning. Industry codes, such as the ASME Pressure Vessel and Piping Codes, often require mandatory performance of PWHT on certain materials to ensure a safe design with optimal mechanical and metallurgical properties.
Joseph Katz is an Israel-born American fluid dynamicist, known for his work on experimental fluid mechanics, cavitation phenomena and multiphase flow, turbulence, turbomachinery flows and oceanography flows, flow-induced vibrations and noise, and development of optical flow diagnostics techniques, including Particle Image Velocimetry (PIV) and Holographic Particle Image Velocimetry (HPIV). As of 2005, he is the William F. Ward Sr. Distinguished Professor at the Department of Mechanical Engineering of the Whiting School of Engineering at the Johns Hopkins University.
Regarding measurement error and more complex thermowell installations:
More recent references involve radiation induced measurement error, sooting flames, and proximity of heat sources.
Regarding thermowell design:
Regarding published failure reports:
Regarding thermowell flow tests with and without strakes: