ELISpot

Last updated

The enzyme-linked immunosorbent spot (ELISpot) is a type of assay that focuses on quantitatively measuring the frequency of cytokine secretion for a single cell. The ELISpot Assay is also a form of immunostaining since it is classified as a technique that uses antibodies to detect a protein analyte, with the word analyte referring to any biological or chemical substance being identified or measured.

Contents

The FluoroSpot Assay is a variation of the ELISpot assay. The FluoroSpot Assay uses fluorescence in order to analyze multiple analytes, meaning it can detect the secretion of more than one type of protein.

History

Cecil Czerkinsky first described ELISpot in 1983 as a new way to quantify the production of an antigen-specific immunoglobulin by hybridoma cells. In 1988, Czerkinsky developed an ELISA spot assay that quantified the secretion of a lymphokine by T cells. In the same year, dual-color ELISpot was combined with computer imaging for the first time, which allowed for the enumeration and analysis of spots. 1988 also marked the first use of membrane-bottomed plates for performing these assays. [1]

Mechanism of ELISpot

  1. Antibody coating: Throughout the ELISpot Assay technique, different substances are added to and washed away from wells. Wells are found on a laboratory plate with tiny dishes/bowls that can be filled with a substance to be examined; the amount of wells on a plate varies, but it usually ranges from 16-100. The first substance added to the wells are cytokine specific monoclonal antibodies. These antibodies coat the walls of the wells for future binding to cytokine. The monoclonal antibodies means that the antibody is produced from a single cell lineage, and is only able to bind to one protein epitope. Polyclonal antibodies, on the other hand, are capable of binding to multiple epitopes of the same protein.
  2. Cell incubation: The desired cells being observed and analyzed are added to the wells. Each well can have the presence or absence of stimuli that activate the secretion of cytokine in cells. During cell incubation, the cells are allowed to react to any present stimuli and secrete cytokine. There are many procedures and methods to follow to ensure proper cell handling. To make sure that cells are of high quality, cells in blood samples should be lightly agitated if stored for longer than 3 hours, the blood samples should be diluted in PBS (phosphate buffered saline) before being stored, and the blood samples should not have granulocytes. Any cells that have been cryopreserved and thawed should be allowed to rest for an hour or more at 37 degrees Celsius (the typical temperature of the human body). [2] There are also many things that should be taken into consideration when incubating the cells, such as making sure that the cells do not experience sudden movements that could affect spot formation, or that the incubator's humidity is high enough to avoid excessive evaporation and drying out the wells. [3]
  3. Cytokine capture: Since the cells are surrounded by cytokine specific monoclonal antibodies that coat the walls of the wells, cytokine that has been secreted by the incubated cells will start to attach to the antibodies at a specific epitope.
  4. Detection antibodies: At this point, the wells must be rinsed in order to get rid of the cells and any other undesirable substances. All that should remain are the cytokine specific monoclonal antibodies and any cytokine that bonded to the antibodies. Biotinylated cytokine-specific detection antibodies are then added to the well. These cytokine-specific detection antibodies will bind to any cytokine that is left in the well since the cytokine is still attached to the first set of antibodies used. Since the cytokine attached to the first set of antibodies coating the wells, the cytokine was not washed away when the wells were rinsed.
  5. Streptavidin-enzyme conjugate: Streptavidin-enzyme conjugate is added to the wells in order to bind with the detection antibodies. The purpose of biotinylating the cytokine-specific detection antibodies added to the wells in the previous step is so that the antibody can bind to the new streptavidin-enzyme conjugate. Biotinylation basically creates a strong affinity between the biotin on the cytokine-specific antibody and the streptavidin on the conjugate. [4]
  6. Addition of substrate: A substrate is added to the wells, and is catalyzed by the enzyme conjugate added in the previous step. This reaction forms insoluble precipitate that forms spots in the wells. The substrate that you use in this step will depend on the type of enzyme used in the previous step. If streptavidin-ALP (streptavidin and alkaline phosphatase conjugate) is used, then using BCIP/NBT-plus (a mixture of 5-bromo-4-chloro-3-indolyl phosphate and nitroblue tetrazolium chloride) [5] as a substrate will produce more distinct spots that are easier to analyze. If streptavidin-HRP (streptavidin and horseradish peroxidase conjugate) is used, then using TMB (tetramethylbenzidine) [6] as a substrate will produce better results. [7]
  7. Analysis: The spots that are formed can then be read on an automated ELISpot reader, or counted under a dissection microscope, and further used to calculate the frequency of cytokine secretion.

Mechanism of FluoroSpot

The FluoroSpot assay is very similar to the ELISpot assay. The main difference is that the FluoroSpot assay is able to analyze the presence of multiple analytes on one plate of wells, whereas the ELISpot assay can only analyze one analyte at a time. The FluoroSpot assay accomplishes this by using fluorescence rather than an enzymatic reaction for detection. The steps for a FluoroSpot assay are also similar, with a few differences. [8]

  1. Antibody Coating: Similar to the ELISpot, cytokine-specific monoclonal capture antibodies are added to a plate with wells. For both assays, the plates are ethanol-treated to avoid contamination and skewed data collection. For the FluoroSpot assay, a mixture of different types of capture antibodies are attached to the wells in order to detect multiple types of analytes. In order to get optimal results with the ELISpot and the FluoroSpot assay, proper plate coating techniques should be followed. The plates should be treated with ethanol, washed, and then coated with antibodies. Ethanol treatment methods also vary depending on the type of plates that are used. For MSIP and IPFL plates, you should add 15 micro liters of 35% ethanol to all of the wells. Allow the ethanol to sit in the wells for one minute, and then pour it out. For MAIPSWU plates, you should instead add 50 micro liters of 70% ethanol to all of the wells. Allow the ethanol to sit in the wells for two minutes, and then pour it out. After you have treated the wells with ethanol, you need to wash all of the wells with 200 micro liters of sterile water. This washing process should be repeated for a total of 5 times. Once the wells have been treated with ethanol and washed, the cytokine-specific monoclonal capture antibodies can be added to each well. [9]
  2. Cell Incubation: Cell are added to the wells and are incubated in the presence or absence of stimuli that affect protein secretion.
  3. Cytokine Capture: Proteins/analytes that are secreted by the incubated cells will bind to the capture antibodies attached to the wells during the first step.
  4. Detection Antibodies: Similar to the ELISpot, once the wells are rinsed to get rid of the cells and other substances that we are not interested in identifying or measuring, a biotinylated detection antibody is added (this is specific for one type of analyte that you wish to quantify) and then tag-labeled detection antibodies are added for the second and third types of analytes being studied.
  5. Fluorophore-labeled Conjugates: Instead of adding a streptavidin-enzyme conjugate, the detection of multiple analytes is amplified in the FluoroSpot with the use of fluorophore-labeled anti-tag antibody and streptavidin-fluorophore conjugate. A fluorescence enhancer solution is also added during this step in order to enhance the signals later used when analyzing the fluorescence colors in the wells. This fluorescence is what makes it possible for the FluoroSpot to analyze and compare multiple analytes, unlike the ELISpot.
  6. Analysis: Since the FluoroSpot relies on the use of fluorescence and not an enzymatic reaction, there is no need for a step that adds a substrate to react with enzymes (as needed for the ELISpot). The last step for the FluoroSpot assay is to analyze the fluorophores under an automated fluorescence reader that has separate filters for the different fluorophores being analyzed. These filters should be selected for the specific wavelengths of the fluorophores if you want accurate measurements. [8]

Since the FluoroSpot assay identifies and quantifies the presence of multiple analytes, it is possible that the absorption of one analyte can affect the secretion of another analyte; this is called capture effects. [8] The effect an analyte has on another analyte could be positive or negative (the production of the second analyte can either increase or decrease). To counteract capture effects, it is possible to use co-stimulation in order to bypass the decreased production of an analyte. [8] This is when a second antibody that stimulates the production of the same analyte is added to the wells.

Applications of ELISpot and FluoroSpot

The ELISpot and FluoroSpot assays can be used in many research fields: vaccine development, [10] cancer, [11] allergies, [12] monocytes/macrophages/dendritic cells characterization, apolipoproteins analysis, and veterinary research. With the ELISpot, you can study antigen-specific cytokine responses, antibody specific secreting cells, [13] tumor antigens, [11] granzyme B and Perforin release by T cells, vaccine efficacy, [14] epitope mapping, [15] cytotoxic T-cell activity, detection of IL-4, IL-5, and IL-13, [12] vaccine-induced antibody responses, antigen-specific memory B cells, [10] and much more.

More specifically, the T-cell ELISpot assay is used to characterize T-cell subsets. This is because the assay can detect the production of cytokines IFN-y, IL-2, TNF-alpha, IL-4, IL-5, and IL-13. The first three cytokines are produced by Th1 cells, while the last three are produced by Th2 cells. Measuring T-cell responses through cytokine production also makes it possible to study vaccine efficacy. [16]

With T-cell FluoroSpot, you can monitor tumor-infiltrating lymphocytes. You can also analyze the IFN-y cytokine and granzyme B secretion in order to assess cytotoxic T-cell responses. Both of these are used for cancer research. [17]

With B-cell FluoroSpot, vaccine efficacy can also be observed by quantifying the secretion of IgG, IgA, and IgM before and after a vaccination. This analysis of multiple immunoglobulins is made possible because of the fluorescence method used in the FluoroSpot. [17]

Related Research Articles

Immunoperoxidase is a type of immunostain used in molecular biology, medical research, and clinical diagnostics. In particular, immunoperoxidase reactions refer to a sub-class of immunohistochemical or immunocytochemical procedures in which the antibodies are visualized via a peroxidase-catalyzed reaction.

<span class="mw-page-title-main">ELISA</span> Method to detect an antigen using an antibody and enzyme

The enzyme-linked immunosorbent assay (ELISA) is a commonly used analytical biochemistry assay, first described by Eva Engvall and Peter Perlmann in 1971. The assay uses a solid-phase type of enzyme immunoassay (EIA) to detect the presence of a ligand in a liquid sample using antibodies directed against the protein to be measured. ELISA has been used as a diagnostic tool in medicine, plant pathology, and biotechnology, as well as a quality control check in various industries.

A biosensor is an analytical device, used for the detection of a chemical substance, that combines a biological component with a physicochemical detector. The sensitive biological element, e.g. tissue, microorganisms, organelles, cell receptors, enzymes, antibodies, nucleic acids, etc., is a biologically derived material or biomimetic component that interacts with, binds with, or recognizes the analyte under study. The biologically sensitive elements can also be created by biological engineering. The transducer or the detector element, which transforms one signal into another one, works in a physicochemical way: optical, piezoelectric, electrochemical, electrochemiluminescence etc., resulting from the interaction of the analyte with the biological element, to easily measure and quantify. The biosensor reader device connects with the associated electronics or signal processors that are primarily responsible for the display of the results in a user-friendly way. This sometimes accounts for the most expensive part of the sensor device, however it is possible to generate a user friendly display that includes transducer and sensitive element. The readers are usually custom-designed and manufactured to suit the different working principles of biosensors.

An assay is an investigative (analytic) procedure in laboratory medicine, mining, pharmacology, environmental biology and molecular biology for qualitatively assessing or quantitatively measuring the presence, amount, or functional activity of a target entity. The measured entity is often called the analyte, the measurand, or the target of the assay. The analyte can be a drug, biochemical substance, chemical element or compound, or cell in an organism or organic sample. An assay usually aims to measure an analyte's intensive property and express it in the relevant measurement unit.

<span class="mw-page-title-main">Flow cytometry</span> Lab technique in biology and chemistry

Flow cytometry (FC) is a technique used to detect and measure physical and chemical characteristics of a population of cells or particles.

<span class="mw-page-title-main">Immunostaining</span> Biochemical technique

In biochemistry, immunostaining is any use of an antibody-based method to detect a specific protein in a sample. The term "immunostaining" was originally used to refer to the immunohistochemical staining of tissue sections, as first described by Albert Coons in 1941. However, immunostaining now encompasses a broad range of techniques used in histology, cell biology, and molecular biology that use antibody-based staining methods.

Plate readers, also known as microplate readers or microplate photometers, are instruments which are used to detect biological, chemical or physical events of samples in microtiter plates. They are widely used in research, drug discovery, bioassay validation, quality control and manufacturing processes in the pharmaceutical and biotechnological industry and academic organizations. Sample reactions can be assayed in 1-1536 well format microtiter plates. The most common microplate format used in academic research laboratories or clinical diagnostic laboratories is 96-well with a typical reaction volume between 100 and 200 µL per well. Higher density microplates are typically used for screening applications, when throughput and assay cost per sample become critical parameters, with a typical assay volume between 5 and 50 µL per well. Common detection modes for microplate assays are absorbance, fluorescence intensity, luminescence, time-resolved fluorescence, and fluorescence polarization.

In biochemistry, biotinylation is the process of covalently attaching biotin to a protein, nucleic acid or other molecule. Biotinylation is rapid, specific and is unlikely to disturb the natural function of the molecule due to the small size of biotin. Biotin binds to streptavidin and avidin with an extremely high affinity, fast on-rate, and high specificity, and these interactions are exploited in many areas of biotechnology to isolate biotinylated molecules of interest. Biotin-binding to streptavidin and avidin is resistant to extremes of heat, pH and proteolysis, making capture of biotinylated molecules possible in a wide variety of environments. Also, multiple biotin molecules can be conjugated to a protein of interest, which allows binding of multiple streptavidin, avidin or neutravidin protein molecules and increases the sensitivity of detection of the protein of interest. There is a large number of biotinylation reagents available that exploit the wide range of possible labelling methods. Due to the strong affinity between biotin and streptavidin, the purification of biotinylated proteins has been a widely used approach to identify protein-protein interactions and post-translational events such as ubiquitylation in molecular biology.

<span class="mw-page-title-main">Immunohistochemistry</span> Common application of immunostaining

Immunohistochemistry (IHC) is the most common application of immunostaining. It involves the process of selectively identifying antigens (proteins) in cells of a tissue section by exploiting the principle of antibodies binding specifically to antigens in biological tissues. IHC takes its name from the roots "immuno", in reference to antibodies used in the procedure, and "histo", meaning tissue. Albert Coons conceptualized and first implemented the procedure in 1941.

<span class="mw-page-title-main">Hybridoma technology</span> Method for producing lots of identical antibodies

Hybridoma technology is a method for producing large numbers of identical antibodies. This process starts by injecting a mouse with an antigen that provokes an immune response. A type of white blood cell, the B cell, produces antibodies that bind to the injected antigen. These antibody producing B-cells are then harvested from the mouse and, in turn, fused with immortal B cell cancer cells, a myeloma, to produce a hybrid cell line called a hybridoma, which has both the antibody-producing ability of the B-cell and the longevity and reproductivity of the myeloma. The hybridomas can be grown in culture, each culture starting with one viable hybridoma cell, producing cultures each of which consists of genetically identical hybridomas which produce one antibody per culture (monoclonal) rather than mixtures of different antibodies (polyclonal). The myeloma cell line that is used in this process is selected for its ability to grow in tissue culture and for an absence of antibody synthesis. In contrast to polyclonal antibodies, which are mixtures of many different antibody molecules, the monoclonal antibodies produced by each hybridoma line are all chemically identical.

<span class="mw-page-title-main">Dot blot</span>

A dot blot is a technique in molecular biology used to detect proteins. It represents a simplification of the western blot method, with the exception that the proteins to be detected are not first separated by electrophoresis. Instead, the sample is applied directly on a membrane in a single spot, and the blotting procedure is performed.

<span class="mw-page-title-main">Antibody-dependent cellular cytotoxicity</span> Cell-mediated killing of other cells mediated by antibodies

Antibody-dependent cellular cytotoxicity (ADCC), also referred to as antibody-dependent cell-mediated cytotoxicity, is a mechanism of cell-mediated immune defense whereby an effector cell of the immune system actively lyses a target cell, whose membrane-surface antigens have been bound by specific antibodies. It is one of the mechanisms through which antibodies, as part of the humoral immune response, can act to limit and contain infection.

<span class="mw-page-title-main">Immunocytochemistry</span>

Immunocytochemistry (ICC) is a common laboratory technique that is used to anatomically visualize the localization of a specific protein or antigen in cells by use of a specific primary antibody that binds to it. The primary antibody allows visualization of the protein under a fluorescence microscope when it is bound by a secondary antibody that has a conjugated fluorophore. ICC allows researchers to evaluate whether or not cells in a particular sample express the antigen in question. In cases where an immunopositive signal is found, ICC also allows researchers to determine which sub-cellular compartments are expressing the antigen.

<span class="mw-page-title-main">Antibody microarray</span>

An antibody microarray is a specific form of protein microarray. In this technology, a collection of captured antibodies are spotted and fixed on a solid surface such as glass, plastic, membrane, or silicon chip, and the interaction between the antibody and its target antigen is detected. Antibody microarrays are often used for detecting protein expression from various biofluids including serum, plasma and cell or tissue lysates. Antibody arrays may be used for both basic research and medical and diagnostic applications.

A tetramer assay is a procedure that uses tetrameric proteins to detect and quantify T cells that are specific for a given antigen within a blood sample. The tetramers used in the assay are made up of four major histocompatibility complex (MHC) molecules, which are found on the surface of most cells in the body. MHC molecules present peptides to T-cells as a way to communicate the presence of viruses, bacteria, cancerous mutations, or other antigens in a cell. If a T-cell's receptor matches the peptide being presented by an MHC molecule, an immune response is triggered. Thus, MHC tetramers that are bioengineered to present a specific peptide can be used to find T-cells with receptors that match that peptide. The tetramers are labeled with a fluorophore, allowing tetramer-bound T-cells to be analyzed with flow cytometry. Quantification and sorting of T-cells by flow cytometry enables researchers to investigate immune response to viral infection and vaccine administration as well as functionality of antigen-specific T-cells. Generally, if a person's immune system has encountered a pathogen, the individual will possess T cells with specificity toward some peptide on that pathogen. Hence, if a tetramer stain specific for a pathogenic peptide results in a positive signal, this may indicate that the person's immune system has encountered and built a response to that pathogen.

A reverse phase protein lysate microarray (RPMA) is a protein microarray designed as a dot-blot platform that allows measurement of protein expression levels in a large number of biological samples simultaneously in a quantitative manner when high-quality antibodies are available.

<span class="mw-page-title-main">Fluorescence in the life sciences</span> Scientific investigative technique

Fluorescence is used in the life sciences generally as a non-destructive way of tracking or analysing biological molecules. Some proteins or small molecules in cells are naturally fluorescent, which is called intrinsic fluorescence or autofluorescence. Alternatively, specific or general proteins, nucleic acids, lipids or small molecules can be "labelled" with an extrinsic fluorophore, a fluorescent dye which can be a small molecule, protein or quantum dot. Several techniques exist to exploit additional properties of fluorophores, such as fluorescence resonance energy transfer, where the energy is passed non-radiatively to a particular neighbouring dye, allowing proximity or protein activation to be detected; another is the change in properties, such as intensity, of certain dyes depending on their environment allowing their use in structural studies.

Chromogenic in situ hybridization (CISH) is a cytogenetic technique that combines the chromogenic signal detection method of immunohistochemistry (IHC) techniques with in situ hybridization. It was developed around the year 2000 as an alternative to fluorescence in situ hybridization (FISH) for detection of HER-2/neu oncogene amplification. CISH is similar to FISH in that they are both in situ hybridization techniques used to detect the presence or absence of specific regions of DNA. However, CISH is much more practical in diagnostic laboratories because it uses bright-field microscopes rather than the more expensive and complicated fluorescence microscopes used in FISH.

A hybridization assay comprises any form of quantifiable hybridization i.e. the quantitative annealing of two complementary strands of nucleic acids, known as nucleic acid hybridization.

<span class="mw-page-title-main">Fluorescence polarization immunoassay</span> Class of invitro biochemical test

Fluorescence polarization immunoassay (FPIA) is a class of in vitro biochemical test used for rapid detection of antibody or antigen in sample. FPIA is a competitive homogenous assay, that consists of a simple prepare and read method, without the requirement of separation or washing steps.

References

  1. Ranieri, Elena; Popescu, Iulia; Gigante, Margherita (2014). "CTL ELISPOT Assay". Cytotoxic T-Cells. Methods in Molecular Biology. Vol. 1186. pp. 75–86. doi:10.1007/978-1-4939-1158-5_6. ISBN   978-1-4939-1157-8. PMID   25149304.
  2. "Cells for ELISpot and FluoroSpot". MABTECH. Retrieved 6 December 2018.
  3. "Cell Incubation". MABTECH. Retrieved 6 December 2018.
  4. "Biotinylation". ThermoFisher Scientific. Retrieved 6 December 2018.
  5. "BCIP/NBT-plus SDS Summary" (PDF). MABTECH. Retrieved 6 December 2018.
  6. "TMB Datasheet/Protocol" (PDF). MABTECH. Retrieved 6 December 2018.
  7. "ELISpot Substrates". MABTECH. Retrieved 6 December 2018.
  8. 1 2 3 4 "FluoroSpot Assay Principle". MABTECH. Retrieved 6 December 2018.
  9. "Plate Coating Guide". MABTECH. Retrieved 6 December 2018.
  10. 1 2 "Vaccine Development". MABTECH. Retrieved 6 December 2018.
  11. 1 2 "Cancer". MABTECH. Retrieved 6 December 2018.
  12. 1 2 "Allergy". MABTECH. Retrieved 6 December 2018.
  13. Czerkinsky, CC (16 December 1983). "A solid-phase enzyme-linked immunospot (ELISPOT) assay for enumeration of specific antibody-secreting cells". Journal of Immunological Methods. 65 (1–2): 109–121. doi:10.1016/0022-1759(83)90308-3. PMID   6361139.
  14. Saletti, Giulietta (9 May 2013). "Enzyme-linked immunospot assays for direct ex vivo measurement of vaccine-induced human humoral immune responses in blood". Nature Protocols. 8 (6): 1073–1087. doi:10.1038/nprot.2013.058. PMID   23660756. S2CID   38317207.
  15. "T cell ELISpot Assays". PROIMMUNE. Retrieved 6 December 2018.
  16. Strand, Nacka. "Find 1 cell in 100,000 with ELISpot" (PDF). MABTECH. Retrieved 6 December 2018.
  17. 1 2 Strand, Nacka. "Discover more with FluoroSpot" (PDF). MABTECH. Retrieved 6 December 2018.