Hoechst stain

Last updated
Chemical structure of Hoechst dyes Structure of Hoechst dyes.svg
Chemical structure of Hoechst dyes

Hoechst stains are part of a family of blue fluorescent dyes used to stain DNA. [1] [2] These bis-benzimides were originally developed by Hoechst AG, which numbered all their compounds so that the dye Hoechst 33342 is the 33,342nd compound made by the company. There are three related Hoechst stains: Hoechst 33258, Hoechst 33342, and Hoechst 34580. The dyes Hoechst 33258 and Hoechst 33342 are the ones most commonly used and they have similar excitationemission spectra.

Contents

Molecular characteristics

Excitation-emission spectra of Hoechst dyes Spectra of Hoechst dyes.svg
Excitation–emission spectra of Hoechst dyes

Both dyes are excited by ultraviolet light at around 350  nm, and both emit blue-cyan fluorescent light around an emission spectrum maximum at 461 nm. Unbound dye has its maximum fluorescence emission in the 510–540 nm range. Hoechst stains can be excited with a xenon- or mercury-arc lamp or with an ultraviolet laser. There is a considerable Stokes shift between the excitation and emission spectra that makes Hoechst dyes useful in experiments in which multiple fluorophores are used. The fluorescence intensity of Hoechst dyes also increases with the pH of the solvent. [3]

Hoechst dyes are soluble in water and in organic solvents such as dimethyl formamide or dimethyl sulfoxide. Concentrations can be achieved of up to 10 mg/mL. Aqueous solutions are stable at 2–6 °C for at least six months when protected from light. For longterm storage the solutions are instead frozen at −20 °C or below. [3]

Hoechst 33258 (magenta) bound to the minor groove of DNA (green and blue). From PDB: 264D . 264D DNA+Hoechst.png
Hoechst 33258 (magenta) bound to the minor groove of DNA (green and blue). From PDB: 264D .

The dyes bind to the minor groove of double-stranded DNA with a preference for sequences rich in adenine and thymine. Although the dyes can bind to all nucleic acids, AT-rich double-stranded DNA strands enhance fluorescence considerably. [4] Hoechst dyes are cell-permeable and can bind to DNA in live or fixed cells. Thus, these stains are often called supravital , meaning that live cells survive a treatment with these compounds. Cells that express specific ATP-binding cassette transporter proteins can also actively transport these stains out of their cytoplasm.[ citation needed ]

Applications

Transmission image of HeLa cells, with overlay of Hoechst 33258 staining (blue). The leftmost cell is in the prometaphase stage of mitosis; its chromosomes fluoresce brightly because they contain highly compacted DNA. HeLa cells stained with Hoechst 33258.jpg
Transmission image of HeLa cells, with overlay of Hoechst 33258 staining (blue). The leftmost cell is in the prometaphase stage of mitosis; its chromosomes fluoresce brightly because they contain highly compacted DNA.
Fluorescent image of cultivated neutrophils isolated from venous blood of human with Alzheimer Disease. Sample was treated with Hoechst 33342 dye that is used to stain DNA. The picture shows the release of DNA by a neutrophil as foggy area in the center of the view field indicating the spontaneous activation of neutrophil extracellular traps formation in AD patients that is not usually observed in healthy mates. Agregation of neutrophils around spontaneously activated netosis observed in Alzheimers' Desease patients blood.jpg
Fluorescent image of cultivated neutrophils isolated from venous blood of human with Alzheimer Disease. Sample was treated with Hoechst 33342 dye that is used to stain DNA. The picture shows the release of DNA by a neutrophil as foggy area in the center of the view field indicating the spontaneous activation of neutrophil extracellular traps formation in AD patients that is not usually observed in healthy mates.

A concentration of 0.1–12 μg/ml is commonly used to stain DNA in bacteria or eukaryote cells. Cells are stained for 1-30 min at room temperature or 37 °C and then washed to remove unbound dye. A green fluorescence of unbound Hoechst dye may be observed on samples which are stained with too much dye or which are washed partially. [3] Hoechst dyes are often used as substitutes for another nucleic acid stain called DAPI.

Key differences between Hoechst dyes and DAPI are:

Hoechst 33342 and 33258 are quenched by bromodeoxyuridine (BrdU), which is commonly used to detect dividing cells. Hoechst 33342 exhibits a 10 fold greater cell-permeability than H 33258. Cells can integrate BrdU in newly synthesized DNA as a substitute for thymidine. When BrdU is integrated into DNA, it is supposed that the bromine deforms the minor groove so that Hoechst dyes cannot reach their optimal binding site. Binding of Hoechst dyes is even stronger to BrdU-substituted DNA; however, no fluorescence ensues. Hoechst dyes can be used with BrdU to monitor cell cycle progression. [7] [8]

Hoechst dyes are commonly used to stain genomic DNA in the following applications:

Hoechst efflux is also used to study hematopoietic and embryonic stem cells. As these cells are able to effectively efflux the dye, they can be detected via flow cytometry in what is termed the side population. This is done by passing the fluorescence emitted from the excited hoechst through both red and blue filters, and plotting hoechst red and blue against each other.[ citation needed ]

Toxicity and safety

Because Hoechst stains bind to DNA, they interfere with DNA replication during cell division. Consequently, they are potentially mutagenic and carcinogenic, so care should be used in their handling and disposal. Hoechst stain is used to sort sperm in livestock and humans. Its safety has been debated. [13] [14]

See also

Related Research Articles

<span class="mw-page-title-main">Staining</span> Technique used to enhance visual contrast of specimens observed under a microscope

Staining is a technique used to enhance contrast in samples, generally at the microscopic level. Stains and dyes are frequently used in histology, in cytology, and in the medical fields of histopathology, hematology, and cytopathology that focus on the study and diagnoses of diseases at the microscopic level. Stains may be used to define biological tissues, cell populations, or organelles within individual cells.

<span class="mw-page-title-main">Flow cytometry</span> Lab technique in biology and chemistry

Flow cytometry (FC) is a technique used to detect and measure physical and chemical characteristics of a population of cells or particles.

<span class="mw-page-title-main">Fluorophore</span> Agents that emit light after excitation by light

A fluorophore is a fluorescent chemical compound that can re-emit light upon light excitation. Fluorophores typically contain several combined aromatic groups, or planar or cyclic molecules with several π bonds.

<span class="mw-page-title-main">Immunofluorescence</span> Technique used for light microscopy

Immunofluorescence is a technique used for light microscopy with a fluorescence microscope and is used primarily on biological samples. This technique uses the specificity of antibodies to their antigen to target fluorescent dyes to specific biomolecule targets within a cell, and therefore allows visualization of the distribution of the target molecule through the sample. The specific region an antibody recognizes on an antigen is called an epitope. There have been efforts in epitope mapping since many antibodies can bind the same epitope and levels of binding between antibodies that recognize the same epitope can vary. Additionally, the binding of the fluorophore to the antibody itself cannot interfere with the immunological specificity of the antibody or the binding capacity of its antigen. Immunofluorescence is a widely used example of immunostaining and is a specific example of immunohistochemistry. This technique primarily makes use of fluorophores to visualise the location of the antibodies.

<span class="mw-page-title-main">Fluorescence microscope</span> Optical microscope that uses fluorescence and phosphorescence

A fluorescence microscope is an optical microscope that uses fluorescence instead of, or in addition to, scattering, reflection, and attenuation or absorption, to study the properties of organic or inorganic substances. "Fluorescence microscope" refers to any microscope that uses fluorescence to generate an image, whether it is a simple set up like an epifluorescence microscope or a more complicated design such as a confocal microscope, which uses optical sectioning to get better resolution of the fluorescence image.

<span class="mw-page-title-main">DAPI</span> Fluorescent stain

DAPI, or 4′,6-diamidino-2-phenylindole, is a fluorescent stain that binds strongly to adenine–thymine-rich regions in DNA. It is used extensively in fluorescence microscopy. As DAPI can pass through an intact cell membrane, it can be used to stain both live and fixed cells, though it passes through the membrane less efficiently in live cells and therefore provides a marker for membrane viability.

<span class="mw-page-title-main">Propidium iodide</span> Chemical compound

Propidium iodide is a fluorescent intercalating agent that can be used to stain cells and nucleic acids. PI binds to DNA by intercalating between the bases with little or no sequence preference. When in an aqueous solution, PI has a fluorescent excitation maximum of 493 nm (blue-green), and an emission maximum of 636 nm (red). After binding DNA, the quantum yield of PI is enhanced 20-30 fold, and the excitation/emission maximum of PI is shifted to 535 nm (green) / 617 nm (orange-red). Propidium iodide is used as a DNA stain in flow cytometry to evaluate cell viability or DNA content in cell cycle analysis, or in microscopy to visualize the nucleus and other DNA-containing organelles. Propidium Iodide is not membrane-permeable, making it useful to differentiate necrotic, apoptotic and healthy cells based on membrane integrity. PI also binds to RNA, necessitating treatment with nucleases to distinguish between RNA and DNA staining. PI is widely used in fluorescence staining and visualization of the plant cell wall.

<span class="mw-page-title-main">Texas Red</span> Chemical compound

Texas Red or sulforhodamine 101 acid chloride is a red fluorescent dye, used in histology for staining cell specimens, for sorting cells with fluorescent-activated cell sorting machines, in fluorescence microscopy applications, and in immunohistochemistry. Texas Red fluoresces at about 615 nm, and the peak of its absorption spectrum is at 589 nm. The powder is dark purple. Solutions can be excited by a dye laser tuned to 595-605 nm, or less efficiently a krypton laser at 567 nm. The absorption extinction coefficient at 596 nm is about 85,000 M−1cm−1.

Cyanines, also referred to as tetramethylindo(di)-carbocyanines are a synthetic dye family belonging to the polymethine group. Although the name derives etymologically from terms for shades of blue, the cyanine family covers the electromagnetic spectrum from near IR to UV.

<span class="mw-page-title-main">Thioflavin</span> Chemical compound

Thioflavins are fluorescent dyes that are available as at least two compounds, namely Thioflavin T and Thioflavin S. Both are used for histology staining and biophysical studies of protein aggregation. In particular, these dyes have been used since 1989 to investigate amyloid formation. They are also used in biophysical studies of the electrophysiology of bacteria. Thioflavins are corrosive, irritants, and are acutely toxic, causing serious eye damage. Thioflavin T has been used in research into Alzheimer's disease and other neurodegenerative diseases.

<span class="mw-page-title-main">Molecular beacon</span>

Molecular beacons, or molecular beacon probes, are oligonucleotide hybridization probes that can report the presence of specific nucleic acids in homogenous solutions. Molecular beacons are hairpin-shaped molecules with an internally quenched fluorophore whose fluorescence is restored when they bind to a target nucleic acid sequence. This is a novel non-radioactive method for detecting specific sequences of nucleic acids. They are useful in situations where it is either not possible or desirable to isolate the probe-target hybrids from an excess of the hybridization probes.

<span class="mw-page-title-main">Acridine orange</span> Organic dye used in biochemistry

Acridine orange is an organic compound that serves as a nucleic acid-selective fluorescent dye with cationic properties useful for cell cycle determination. Acridine orange is cell-permeable, which allows the dye to interact with DNA by intercalation, or RNA via electrostatic attractions. When bound to DNA, acridine orange is very similar spectrally to an organic compound known as fluorescein. Acridine orange and fluorescein have a maximum excitation at 502nm and 525 nm (green). When acridine orange associates with RNA, the fluorescent dye experiences a maximum excitation shift from 525 nm (green) to 460 nm (blue). The shift in maximum excitation also produces a maximum emission of 650 nm (red). Acridine orange is able to withstand low pH environments, allowing the fluorescent dye to penetrate acidic organelles such as lysosomes and phagolysosomes that are membrane-bound organelles essential for acid hydrolysis or for producing products of phagocytosis of apoptotic cells. Acridine orange is used in epifluorescence microscopy and flow cytometry. The ability to penetrate the cell membranes of acidic organelles and cationic properties of acridine orange allows the dye to differentiate between various types of cells. The shift in maximum excitation and emission wavelengths provides a foundation to predict the wavelength at which the cells will stain.

<span class="mw-page-title-main">SYBR Green I</span> Dye used for molecular genetics

SYBR Green I (SG) is an asymmetrical cyanine dye used as a nucleic acid stain in molecular biology. The SYBR family of dyes is produced by Molecular Probes Inc., now owned by Thermo Fisher Scientific. SYBR Green I binds to DNA. The resulting DNA-dye-complex best absorbs 497 nanometer blue light and emits green light. The stain preferentially binds to double-stranded DNA, but will stain single-stranded (ss) DNA with lower performance. SYBR Green can also stain RNA with a lower performance than ssDNA.

<span class="mw-page-title-main">7-Aminoactinomycin D</span> Chemical compound

7-Aminoactinomycin D (7-AAD) is a fluorescent chemical compound with a strong affinity for DNA. It is used as a fluorescent marker for DNA in fluorescence microscopy and flow cytometry. It intercalates in double-stranded DNA, with a high affinity for GC-rich regions, making it useful for chromosome banding studies.

<span class="mw-page-title-main">Fluorescence in the life sciences</span> Scientific investigative technique

Fluorescence is used in the life sciences generally as a non-destructive way of tracking or analysing biological molecules. Some proteins or small molecules in cells are naturally fluorescent, which is called intrinsic fluorescence or autofluorescence. Alternatively, specific or general proteins, nucleic acids, lipids or small molecules can be "labelled" with an extrinsic fluorophore, a fluorescent dye which can be a small molecule, protein or quantum dot. Several techniques exist to exploit additional properties of fluorophores, such as fluorescence resonance energy transfer, where the energy is passed non-radiatively to a particular neighbouring dye, allowing proximity or protein activation to be detected; another is the change in properties, such as intensity, of certain dyes depending on their environment allowing their use in structural studies.

Cell cycle analysis by DNA content measurement is a method that most frequently employs flow cytometry to distinguish cells in different phases of the cell cycle. Before analysis, the cells are usually permeabilised and treated with a fluorescent dye that stains DNA quantitatively, such as propidium iodide (PI) or 4,6-diamidino-2-phenylindole (DAPI). The fluorescence intensity of the stained cells correlates with the amount of DNA they contain. As the DNA content doubles during the S phase, the DNA content (and thereby intensity of fluorescence) of cells in the G0 phase and G1 phase (before S), in the S phase, and in the G2 phase and M phase (after S) identifies the cell cycle phase position in the major phases (G0/G1 versus S versus G2/M phase) of the cell cycle. The cellular DNA content of individual cells is often plotted as their frequency histogram to provide information about relative frequency (percentage) of cells in the major phases of the cell cycle.

<span class="mw-page-title-main">Chromatin bridge</span> Medical condition

Chromatin bridge is a mitotic occurrence that forms when telomeres of sister chromatids fuse together and fail to completely segregate into their respective daughter cells. Because this event is most prevalent during anaphase, the term anaphase bridge is often used as a substitute. After the formation of individual daughter cells, the DNA bridge connecting homologous chromosomes remains fixed. As the daughter cells exit mitosis and re-enter interphase, the chromatin bridge becomes known as an interphase bridge. These phenomena are usually visualized using the laboratory techniques of staining and fluorescence microscopy.

YOYO-1 is a green fluorescent dye used in DNA staining. It belongs to the family of monomethine cyanine dyes and is a tetracationic homodimer of Oxazole Yellow, typically available as tetraiodide salt. In aqueous buffer, free YOYO-1 dye has very low fluorescence quantum yield. However, the intensity of fluorescence increases 3200 times upon binding through bis-intercalation to double-stranded DNA.

Bacterioplankton counting is the estimation of the abundance of bacterioplankton in a specific body of water, which is useful information to marine microbiologists. Various counting methodologies have been developed over the years to determine the number present in the water being observed. Methods used for counting bacterioplankton include epifluorescence microscopy, flow cytometry, measures of productivity through frequency of dividing cells (FDC), thymidine incorporation, and leucine incorporation.

<span class="mw-page-title-main">SYBR Gold</span> Chemical compound

SYBR Gold is an asymmetrical cyanine dye. It can be used as a stain for double-stranded DNA, single-stranded DNA, and RNA. SYBR Gold is the most sensitive fluorescent stain of the SYBR family of dyes for the detection of nucleic acids. The SYBR family of dyes is produced by Molecular Probes Inc., now owned by Thermo Fisher Scientific

References

  1. Latt, SA; Stetten, G; Juergens, LA; Willard, HF; Scher, CD (July 1975). "Recent developments in the detection of deoxyribonucleic acid synthesis by 33258 Hoechst fluorescence". Journal of Histochemistry and Cytochemistry. 23 (7): 493–505. doi: 10.1177/23.7.1095650 . PMID   1095650.
  2. Latt, SA; Stetten, G (January 1976). "Spectral studies on 33258 Hoechst and related bisbenzimidazole dyes useful for fluorescent detection of deoxyribonucleic acid synthesis". Journal of Histochemistry and Cytochemistry. 24 (1): 24–33. doi: 10.1177/24.1.943439 . PMID   943439.
  3. 1 2 3 "Hoechst Stains" (PDF). Invitrogren (Molecular Probes). Archived from the original (PDF) on 2009-04-19.
  4. Portugal, J; Waring, MJ (Feb 28, 1988). "Assignment of DNA binding sites for 4′,6-diamidine-2-phenylindole and bisbenzimide (Hoechst 33258). A comparative footprinting study". Biochimica et Biophysica Acta (BBA) - Gene Structure and Expression. 949 (2): 158–68. doi:10.1016/0167-4781(88)90079-6. PMID   2449244.
  5. BD Bioscience (2009). Techniques for Immune Function Analysis (PDF) (2 ed.). Becton, Dickinson and Company.
  6. Bucevičius, Jonas; Lukinavičius, Gražvydas; Gerasimaitė, Rūta (2018-04-18). "The Use of Hoechst Dyes for DNA Staining and beyond". Chemosensors. 6 (2): 18. doi: 10.3390/chemosensors6020018 . hdl: 21.11116/0000-0001-A4FE-8 . ISSN   2227-9040.
  7. Kubbies, M; Rabinovitch, PS (January 1983). "Flow cytometric analysis of factors which influence the BrdUrd-Hoechst quenching effect in cultivated human fibroblasts and lymphocytes". Cytometry. 3 (4): 276–81. doi: 10.1002/cyto.990030408 . PMID   6185287.
  8. Breusegem, SY; Clegg, RM; Loontiens, FG (Feb 1, 2002). "Base-sequence specificity of Hoechst 33258 and DAPI binding to five (A/T)4 DNA sites with kinetic evidence for more than one high-affinity Hoechst 33258-AATT complex". Journal of Molecular Biology. 315 (5): 1049–61. doi:10.1006/jmbi.2001.5301. PMID   11827475.
  9. Iain Johnson, Michelle T.Z. Spence, ed. (2011). Molecular Probes Handbook: A Guide to Fluorescent Probes and Labeling Technologies (11 ed.). Invitrogen. ISBN   978-0-9829279-1-5.
  10. Kubbies, M (1990). "Flow cytometric recognition of clastogen induced chromatin damage in G0/G1 lymphocytes by non-stoichiometric Hoechst fluorochrome binding". Cytometry. 11 (3): 386–94. doi: 10.1002/cyto.990110309 . PMID   1692786.
  11. 1 2 Mocharla, R; Mocharla, H; Hodes, ME (Dec 23, 1987). "A novel, sensitive fluorometric staining technique for the detection of DNA in RNA preparations". Nucleic Acids Research. 15 (24): 10589. doi:10.1093/nar/15.24.10589. PMC   339970 . PMID   2447564.
  12. Sterzel, W; Bedford, P; Eisenbrand, G (June 1985). "Automated determination of DNA using the fluorochrome Hoechst 33258". Analytical Biochemistry. 147 (2): 462–7. doi:10.1016/0003-2697(85)90299-4. PMID   2409841.
  13. Ashwood-Smith, M.J. (1994). "Safety of human sperm selection by flow cytometry". Human Reproduction . Oxford University Press. 9 (5): 757–759. doi:10.1093/oxfordjournals.humrep.a138589. PMID   7929716.
  14. Parrilla, I; Vázquez, J M; Cuello, C; Gil, MA; Roca, J; Di Berardino, D; Martínez, EA (2004). "Hoechst 33342 stain and u.v. laser exposure do not induce genotoxic effects in flow-sorted boar spermatozoa". Reproduction . 128 (5): 615–621. doi: 10.1530/rep.1.00288 . PMID   15509707.