This list article lists file formats for luminaire radiometric data. File formats from standards organizations are grouped in Table 1 and other formats appear in Table 2.
Computer files using these formats are designed to be imported into lighting simulation software for architectural lighting design, and are not readily interpreted by human readers. [1] They typically contain data describing the light output of luminaires (i.e., light fixtures), but can also represent the lamps (i.e., light bulbs) and other kinds of light sources used within luminaires. If such a file exists for a given lighting product, it can usually be obtained from a vendor (e.g., manufacturer website).
Some formats were only designed to describe visible radiation (i.e., light), but can be adapted to describe other kinds of optical radiation—namely ultraviolet radiation and/or infrared radiation—if the file is appropriately annotated and the user understands the deviation. [2] [3] Other formats were explicitly designed to describe any kind of optical radiation to support the design and analysis of systems for germicidal, horticulture, lighting, heating, and other applications. [4] [5]
Whereas photometry covers the measurement of light (typically weighted by wavelength according to a luminous efficiency function), radiometry more broadly covers the measurement of optical radiation (sometimes extended to other kinds of electromagnetic radiation) without regard for spectral sensitivity. [6] Photometry is thus a subset or branch of radiometry. This page focuses on file formats that include one or more of the following kinds of radiometric data:
These granular data can be used to calculate other metrics such as luminous flux (e.g., total lumen output), beam angle, and correlated color temperature. Notably, the reverse is often impossible (e.g., typically cannot derive SPD from CCT). [10] With additional information, such as distance and angle of incidence, luminous intensity distribution data can also be used to calculate illuminance (by combining the cosine law with the inverse-square law [11] [7] ) and other quantities.
Formats often accommodate additional kinds of data useful in designing systems (e.g., electrical input power, physical dimensions). Some formats can also contain photon intensity distribution data, which capture photon intensity data in multiple directions; such data is based on photon counting, which is distinct from radiometry and can for example be useful when designing horticultural lighting systems to provide sufficient photosynthetically active radiation (PAR).
| File format | Filename extensions | Editions | Status | Supported kinds of distribution data |
|---|---|---|---|---|
| CIBSE TM14 | .c1s, .cc, .cib, .tml | 1988 [12] | Archived | Luminous intensity |
| EN 13032-1 | .cen | 2004, 2012 [13] | Active European standard, based on archived CIE 102-1993 [14] | Luminous intensity |
| IES LM-63 | .ies | 1986, 1991, 1995, 2002, 2019, 2025 [15] | Active ANSI standard | Luminous intensity |
| IES TM-27 | .spdx | 2014, 2020 [16] | Active ANSI standard | SPD |
| IES TM-33 | .json, .xml | 2018, 2023 [17] | Active ANSI standard | Luminous intensity, photon intensity, radiant intensity, SPD, ASRID |
| ISO 16739-1 (IFC) | .ifc, .ifcXML, .ifcZIP, .ttl, .rdf | 2005, 2013, 2018, 2024 [18] [19] | Active ISO standard | Luminous intensity |
| UNI 11733 | .json, .xml | 2019, [20] 2020 [21] | Active Italian standard | Luminous intensity, photon intensity, radiant intensity, SPD, ASRID |
| File format | Filename extensions | Editions | Status | Supported kinds of distribution data |
|---|---|---|---|---|
| ATLA S001 and S001-A | .json, .xml | 2018, [22] 2021 [23] | Open file format, basis for IES TM-33 and UNI 11733 [24] [25] [26] [27] [28] | Luminous intensity, photon intensity, radiant intensity, SPD, ASRID |
| DIALux | .uld | n/a | Proprietary file format [29] [30] | Luminous intensity |
| EULUMDAT | .exl, .ldt | 1990, 1998 [31] [32] | Open file format, de facto European standard [33] [34] [1] [35] | Luminous intensity |
| GLDF | .gldf, .xml | v1.0.rc3 [36] | Open file format, requires other formats for luminous intensity distribution data (via ZIP), remains in development [37] | Luminous intensity, SPD |
| LiteStar 4D | .oxl | 2015 [38] | Open file format in XML [39] | Luminous intensity, SPD |
| Relux | .rolf | n/a | Proprietary file format [40] | Luminous intensity |
Building information modeling (BIM) involves the generation and management of digital representations of the physical and functional characteristics of buildings or other physical assets and facilities. Some file formats used in BIM can include luminous intensity distribution data but may not specify its format.
Character encoding (the use of a numeric value to digitally represent each character) can differ between file formats. For example, IES LM-63 uses ASCII encoding, while IES TM-33 uses UTF-8 encoding.