Draft (water)

Last updated
Fire engine drafting Fire-engine-drafting.jpg
Fire engine drafting

A draft is the use of suction to move a liquid such as water from a vessel or body of water below the intake of a suction pump. A rural fire department or farmer might draft water from a pond as the first step in moving the water elsewhere. A suction pump creates a partial vacuum (a "draft") and the atmospheric pressure on the water's surface forces the water into the pump, usually via a rigid pipe (sometimes called a dry hydrant) or a semi-rigid hard suction hose. [1] [2]

Standard atmospheric pressure is 101 kPa (14.7 lbf/in²) and that can only raise water to a theoretical maximum of 10.3 metres (34 feet). [3] Depending on application, fire department pumps lift water 6 to 10 metres (20 to 33 ft).

Medium diameter hard suction hose, with attached strainer, for use with wildland firefighting apparatus. Hard suction end med strainer.jpg
Medium diameter hard suction hose, with attached strainer, for use with wildland firefighting apparatus.

To reduce drafting friction and obtain a larger flow or higher lift, a larger cross-section of suction hose is employed. For example, using a five-inch (127 mm) hose, a pump that could lift 500 US gallons per minute (30 L/s) up 23 feet (7.0 m) would only be able to lift the same amount of water 12.5 feet (3.8 m) through a 3.5-inch (89 mm) hose. Fire engines are often seen carrying two or three 10-foot (3.0 m) lengths of suction hose, but the longer the lift, the lower the flow, for a fixed-diameter suction hose and a given pump. Multiple relays could be used if the need arises, with a suction pump drafting up to 10 metres (33 feet) and discharging at great distances.

It is also possible to use a gravity siphon to draft water for a small lift, and this technique is often used in forest fire suppression, where portable reservoirs of 1,000 to 3,000 US gallons (5 to 10 m³) are filled with water and small hoses are used downhill of the tanks. The nozzle pressure is proportional to its distance below the reservoir surface. 100 ft height change yields approximately 43 psi. The tank may itself be gravity-fed through hoses from a nearby water source, or by pumps or helicopters delivering water from further away.

See also

Related Research Articles

<span class="mw-page-title-main">Fire engine</span> Emergency vehicle intended to put out fires

A fire engine is a road vehicle that functions as a firefighting apparatus. The primary purposes of a fire engine include transporting firefighters and water to an incident as well as carrying equipment for firefighting operations. Some fire engines have specialized functions, such as wildfire suppression and aircraft rescue and firefighting, and may also carry equipment for technical rescue.

<span class="mw-page-title-main">Fire hose</span> Flexible tube used for delivering water or foam at high pressure, to fight fires

A fire hose is a high-pressure hose that carries water or other fire retardant to a fire to extinguish it. Outdoors, it attaches either to a fire engine, fire hydrant, or a portable fire pump. Indoors, it can permanently attach to a building's standpipe or plumbing system.

<span class="mw-page-title-main">Fire hydrant</span> Connection point by which firefighters can tap into a water supply

A fire hydrant, fireplug, or firecock (archaic) is a connection point by which firefighters can tap into a water supply. It is a component of active fire protection. Underground fire hydrants have been used in Europe and Asia since at least the 18th century. Above-ground pillar-type hydrants are a 19th-century invention.

<span class="mw-page-title-main">Siphon</span> Device involving the flow of liquids through tubes

A siphon is any of a wide variety of devices that involve the flow of liquids through tubes. In a narrower sense, the word refers particularly to a tube in an inverted "U" shape, which causes a liquid to flow upward, above the surface of a reservoir, with no pump, but powered by the fall of the liquid as it flows down the tube under the pull of gravity, then discharging at a level lower than the surface of the reservoir from which it came.

<span class="mw-page-title-main">Injector</span> Type of pump using high pressure fluid to entrain a lower pressure fluid

An injector is a system of ducting and nozzles used to direct the flow of a high-pressure fluid in such a way that a lower pressure fluid is entrained in the jet and carried through a duct to a region of higher pressure. It is a fluid-dynamic pump with no moving parts except a valve to control inlet flow. A steam injector is a typical application of the principle used to deliver cold water to a boiler against its own pressure, using its own live or exhaust steam, replacing any mechanical pump. When first developed, its operation was intriguing because it seemed paradoxical, almost like perpetual motion, but it was later explained using thermodynamics. Other types of injector may use other pressurised motive fluids such as air.

Firefighting jargon includes a diverse lexicon of both common and idiosyncratic terms. One problem that exists in trying to create a list such as this is that much of the terminology used by a particular department is specifically defined in their particular standing operating procedures, such that two departments may have completely different terms for the same thing. For example, depending on whom one asks, a safety team may be referred to as a standby, a RIT or RIG or RIC, or a FAST. Furthermore, a department may change a definition within its SOP, such that one year it may be RIT, and the next RIG or RIC.

This glossary of wildfire terms is a list of definitions of terms and concepts relevant to wildfires and wildland firefighting. Except where noted, terms have largely been sourced from a 1998 Fireline Handbook transcribed for a Conflict 21 counter-terrorism studies website by the Air National Guard.

This is a glossary of firefighting equipment.

In a hydraulic circuit, net positive suction head (NPSH) may refer to one of two quantities in the analysis of cavitation:

  1. The Available NPSH (NPSHA): a measure of how close the fluid at a given point is to flashing, and so to cavitation. Technically it is the absolute pressure head minus the vapour pressure of the liquid.
  2. The Required NPSH (NPSHR): the head value at the suction side required to keep the fluid away from cavitating.
<span class="mw-page-title-main">Wildland fire engine</span>

A wildland fire engine is a fire engine specifically designed to assist in fighting wildfires by transporting firefighters to the scene and providing them with access to the fire, along with water or other equipment. Most commonly used by the United States Forest Service, there are multiple types of wildfire apparatus which are used in different scenarios. According to the National Fire Protection Association, if the apparatus will be used primarily for outdoor and wildland responses, then it is to be considered a wildland fire apparatus and must conform to NFPA 1906.

<span class="mw-page-title-main">Wildland water tender</span>

A wildland water tender is a specialized vehicle capable of bringing water, foam, or dry chemicals to fire trucks in the field that are engaged on the fireline. Water tenders have a large truck mounted tank that carries a minimum 1,000 gallons and up to 4,000 gallons of water. These vehicles are specifically designed for fire fighting often with four-wheel drive, rugged suspension and high wheel clearance for mountainous dirt road conditions. According to the National Fire Protection Association, if the apparatus will be used primarily for outdoor and wildland responses, then it is to be considered a wildland fire apparatus and must conform to NFPA 1906.

<span class="mw-page-title-main">Compressed air foam system</span>

A compressed air foam system is used in firefighting to deliver fire retardant foam for the purpose of extinguishing a fire or protecting unburned areas. Allegedly.

A muster is an event pertaining to fire/rescue services. It is held in a central area such as a park and has many activities for fire department members and sometimes other community members. A muster typically revolves around a firematic competition between fire companies from around the surrounding area. Other attractions include a flea market, live music, food, demonstrations, apparatus judging, vehicle shows and contests.

<span class="mw-page-title-main">Hard suction hose</span> Drafting fire hose made to withstand vacuum

Flexible suction hose, not to be confused with hard suction hose in U.S., is a specific type of fire hose used in drafting operations, when a fire engine uses a vacuum to draw water from a portable water tank, pool, or other static water source. It is built to withstand vacuum, rather than pressure, abrasion, and heat. Conversely, hard suction is capable of withstanding up to 200 PSIG, as well as vacuum. In the United States, it is standard equipment according to the National Fire Protection Association standards for fire engines. It is used in both structural and wildland firefighting throughout the world, and is made in various diameters and connection types.

<span class="mw-page-title-main">Portable water tank</span>

A portable water tank is a temporary collapsible tank designed for the reserve storage of water in firefighting, emergency relief, and military applications. These tanks can be either supported or unsupported. The supported tanks have a steel or aluminum frame and range in size from 600 to 5000 US gallons or larger by custom design. Portable water tanks are also unsupported such as self-supporting tanks, blivets and pillow or bladder tanks and are available in sizes ranging from 100 US gallons (380 L) up to 80,000 US gallons (300,000 L).

A suction excavator or vacuum excavator is a construction vehicle that removes materials from a hole on land, or removes heavy debris on land.

<span class="mw-page-title-main">Vacuum truck</span> Tank truck with a pump designed to load material through suction lines

A vacuum truck, vacuum tanker, vactor truck, vactor, vac-con truck, vac-con is a tank truck that has a pump and a tank. The pump is designed to pneumatically suck liquids, sludges, slurries, or the like from a location into the tank of the truck. The objective is to enable transport of the liquid material via road to another location. Vacuum trucks transport the collected material to a treatment or disposal site, for example a sewage treatment plant.

<span class="mw-page-title-main">San Francisco Fire Department Auxiliary Water Supply System</span>

The Auxiliary Water Supply System is a high pressure water supply network built for the city of San Francisco in response to the failure of the existing emergency water system during the 1906 earthquake. It was originally proposed by San Francisco Fire Department chief engineer Dennis T. Sullivan in 1903, with construction beginning in 1909 and finishing in 1913. The system is made up of a collection of water reservoirs, pump stations, cisterns, suction connections and fireboats. While the system can use both fresh or salt water, it is preferential to not use salt water, as it commonly causes galvanic corrosion in fire equipment.

<span class="mw-page-title-main">Humphrey pump</span>

The Humphrey pump is a large internal combustion gas-fuelled liquid-piston pump. They were used for large-scale water supply projects. They were only popular for a short time, from around 1910 to the outbreak of World War I, but they continued in service for a long period afterwards, some lasting into the 1970s.

<span class="mw-page-title-main">Santa Barbara County Fire Department</span> American county fire department

The Santa Barbara County Fire Department (SBCFD) provides fire protection and emergency response services for the unincorporated areas of Santa Barbara County, California, and for multiple cities within the county. Together, these areas compose the Santa Barbara County Fire Protection District.

References

  1. Corbett, Glenn (2009). Fire Engineering's Handbook for Firefighter I and II. p. 434. ISBN   9781593701352.
  2. Lowell Fire Department. Drafting Drill (PDF).[ permanent dead link ]
  3. Jimenez, Dan. "3.5 Drafting Guidelines". Firefighter Math.