Two-in, two-out

Last updated

In firefighting, the policy of two-in, two-out refers to United States Occupational Safety and Health Administration (OSHA) policy 29 CFR 1910.134(g)(4)(i). [1] The respiratory protection standard requires that workers engaged in fighting interior structural fires work in a buddy system; at least two workers must enter the building together, so that they can monitor each other's whereabouts as well as the work environment. There must also be at least two standby personnel outside the fire area prepared to rescue the inside firefighters should the need arise. One of these outside firefighters must actively monitor the status of the inside fighters but the second outside firefighter may perform a variety of other duties, such as pump operations, incident commander or outside hose line operation. There are no provisions in the standard to waive the requirements for either the "two-inside firefighters" or the "two-outside firefighters", although the circumstances under which this provision applies are more limited than generally understood. [2]

Contents

The standard does not require the "two-in/two-out" provision if the fire is still in the incipient stage and it does not prohibit firefighters from fighting the fire from outside before sufficient personnel have arrived. It also does not prohibit firefighters from entering a burning structure to perform rescue operations (Search) when there is a reasonable belief that victims may be inside. It is only when firefighters are engaged in the interior attack of an interior structural firefighting that the "two-in/two-out" requirement applies. It is the incident commander's responsibility to judge whether a fire is an interior structural fire and how it will be attacked. [2]

Explanation

Two-in

The respiratory protection standard requires that workers engaged in fighting interior structural fires work in a buddy system; at least two workers must enter the building together, so that they can monitor each other's whereabouts as well as the work environment. An interior structural fire (an advanced fire that has spread inside of the building where high temperatures, "heat" and dense smoke are normally occurring) would present an "Immediately Dangerous to Life or Health" (IDLH) atmosphere and therefore, require the use of respirators. There should always be at least two firefighters together when they enter a location that is deemed a hazard area that is considered IDLH (i.e., the interior of the structure fire). Firefighters operating in the hazard area must operate in a buddy system and maintain voice or visual contact with one another at all times. This helps in assuring accountability within the team. They must operate together as a team all the time they are in the hazard area. If one firefighter has to leave the hazard area, for any reason, such as air supply getting low, they must both exit.

Two-out

OSHA requires that one of the two firefighters outside must be dedicated to accounting for the two firefighters inside, and, if necessary, initiate a fire fighter rescue. The other firefighter is permitted to take on other roles, such as incident commander in charge of the emergency incident, safety officer or equipment/pump operator. However, the second firefighter outside cannot be assigned tasks that are critical to the safety and health of any other employee working at the incident.

These rules also apply to all training with live fires inside structures, and are even more important when inexperienced trainees are inside.

(OSHA) only when firefighters are engaged in the interior attack of an interior structural fire that the "two-in/two-out" requirement applies. It does not prohibit firefighters from entering a structure fire to do a search before an entire team has been assembled

The standard does not require the "two-in/two-out" provision if the fire is still in the incipient stage and it does not prohibit firefighters from fighting the fire from outside before sufficient personnel have arrived. It also does not prohibit firefighters from entering a burning structure to perform rescue operations when there is a reasonable belief that victims may be inside. It is only when firefighters are engaged in the interior attack of an interior structural firefighting that the "two-in/two-out" requirement applies.  The interpretation covers the number of persons who must be on the scene before fire fighting personnel may begin the interior attack on an interior structural fire. Until those persons arrive on the scene, fire fighters may fight the blaze from outside the structure and carry out rescue activities.    Incipient stage fire  An incipient stage fire is defined as a fire that is in the initial or beginning stage and can be controlled or extinguished by portable fire extinguishers, Class II standpipe, or small hose systems without the need for protective clothing or breathing apparatus.

Rapid intervention crew

The National Fire Protection Association (NFPA) defines the policy that refers to a safety system to protect firefighters, known as rapid intervention crew(RIC) or firefighter assist and search team(FAST), where two or more firefighters enter a building and at least two more remain outside, near the entrance, fully equipped and ready to help in case of emergency.

Firefighters enter a building in teams to extinguish the fire and/or make a rescue. When a team enters an IDLH atmosphere (the "two-in"), two more firefighters (the "two-out") stand by at the entrance in full personal protective equipment (to include bunker gear and self-contained breathing apparatus), and ready with rescue tools, in order to rapidly enter the building if the team inside becomes endangered. By some interpretations, the rule requires at least two more firefighters to remain outside, even when the standby team has gone in to find and rescue the first team. However, the rule specifically exempts an emergency rescue with fewer personnel on hand (i.e., no additional "two-out" required if they go in to find the "two-in"), although the increased risk to all four should be obvious if further backup is not on-scene.

The two firefighters who are specifically designated as standing by outside are referred to in different ways by many localities. The NFPA designated term is "RIC", [3] some are referred to as a rapid intervention team, and others are referred to as a F.A.S.T. truck (as in the Fire Department of New York).

Where there are teams working inside multiple entrances of a large structure fire, there may be standby teams designated at each entry point, although the rule does not necessarily mean two firefighters ready outside for every two inside.

Other tactics work within the rule to "stage" the next team, ready to relieve the inside team when their air supplies run low. When the third team arrives to serve as the RIT, the second team enters, follows the hose line to the first team and relieves them. This is naturally smoother with good radio communications between officers.

Application in France

Until 1999, the firefighting in France was performed according to the "Rules of instruction and maneuvers" (Règlement d'instructions et de manoeuvres, RIM). The firefighters acted in teams of three members, called "trinomial" (trinôme): one chief, one deputy chief and one support; a fire engine with eight people thus had two trinom, an engine chief (chef d'agrès) and a driver. In the 1990s, the Paris Fire Brigade started to work with teams of two people, called "binomial teams" (équipes en binôme) or shortly "binomials" (binômes). This organisation was generalised to the whole France in a departmental order signed by the minister of Internal Affairs the 3 February 1999. An engine with eight people now has three binomials, an engine chief and a driver; an engine with six people has two binomials, an engine chief and a driver.

A binomial can be assigned two types of missions:

The mission can change during an intervention (i.e., an attack binomial can become a supply binomial or vice versa).

The "usual" intervention (simple fire with only one fire engine and six people, no casualty, no specific risk) thus involves two binomials.

  1. The engine chief makes a reconnaissance with an attack binomial. The other binomial stands by outside, ready to help the reconnaissance team.
  2. The attack binomial unrolls the fire hoses at the "attack point" defined by the engine chief and prepare to go to the target also defined by the engine chief. The supply binomial joins the attack point to the fire engine with hoses.
  3. The attack binomial starts the firefighting. The supply binomial joins the fire engine to the hydrant.
  4. The supply binomial stands by, ready to help the attack binomial.

The overall organisation is the same when more engines are involved.

Germany

German fire services regulations (FwDV) demand that firefighters must always operate in teams of two, called a Trupp; and that an interior attack with breathing apparatus may only be undertaken if there's at least a Staffel on scene, which consists of six firefighters: two Trupps, a commander, and an engineer. [4] Furthermore, every incident scene where breathing apparatus is in use must have at least one Trupp with breathing apparatus on standby as a dedicated rescue team, and more where appropriate. [5]

See also

Related Research Articles

<span class="mw-page-title-main">Firefighter</span> Rescuer trained to extinguish fires and save people

A firefighter is a first responder trained in firefighting, primarily to control and extinguish fires that threaten life and property, as well as to rescue persons from confinement or dangerous situations. Male firefighters are sometimes referred to as firemen.

<span class="mw-page-title-main">Fire engine</span> Emergency vehicle intended to put out fires

A fire engine is a vehicle, usually a specially-designed or modified truck, that functions as a firefighting apparatus. The primary purposes of a fire engine include transporting firefighters and water to an incident as well as carrying equipment for firefighting operations in a fire drill. Some fire engines have specialized functions, such as wildfire suppression and aircraft rescue and firefighting, and may also carry equipment for technical rescue.

<span class="mw-page-title-main">Self-contained breathing apparatus</span> Breathing gas supply system carried by the user

A self-contained breathing apparatus (SCBA) is a device worn to provide an autonomous supply of breathable gas in an atmosphere that is immediately dangerous to life or health. They are typically used in firefighting and industry. The term self-contained means that the SCBA is not dependent on a remote supply of breathing gas. If designed for use under water, it is also known as a scuba set. When not used underwater, they are sometimes called industrial breathing sets. Some types are also referred to as a compressed air breathing apparatus (CABA) or simply breathing apparatus (BA). Unofficial names include air pack, air tank, oxygen cylinder or simply pack, which are mostly used in firefighting.

<span class="mw-page-title-main">Firefighting</span> Actions to prevent damage from fire

Firefighting is a profession aimed at controlling and extinguishing fire. A person who engages in firefighting is known as a firefighter or fireman. Firefighters typically undergo a high degree of technical training. This involves structural firefighting and wildland firefighting. Specialized training includes aircraft firefighting, shipboard firefighting, aerial firefighting, maritime firefighting, and proximity firefighting.

<span class="mw-page-title-main">PASS device</span> Device used to set off an alarm when a firefighter is in distress

A PASS device, also known as a Distress Signal Unit (DSU) or ADSU, is a personal safety device used primarily by firefighters entering a hazardous or Immediately Dangerous to Life and Health (IDLH) environment such as a burning building. The PASS device sounds a loud (95 decibel) audible alert to notify others in the area that the firefighter is in distress. On a fireground, the sound of an activated PASS device indicates a true emergency and results in an immediate response to rescue the firefighter(s) in distress. In the United States, the National Fire Protection Association sets standards for PASS devices in NFPA 1982.

<span class="mw-page-title-main">Immediately dangerous to life or health</span> Exposure to dangerous levels of airborne contaminants

The term immediately dangerous to life or health (IDLH) is defined by the US National Institute for Occupational Safety and Health (NIOSH) as exposure to airborne contaminants that is "likely to cause death or immediate or delayed permanent adverse health effects or prevent escape from such an environment." Examples include smoke or other poisonous gases at sufficiently high concentrations. It is calculated using the LD50 or LC50. The Occupational Safety and Health Administration (OSHA) regulation defines the term as "an atmosphere that poses an immediate threat to life, would cause irreversible adverse health effects, or would impair an individual's ability to escape from a dangerous atmosphere."

Firefighting jargon includes a diverse lexicon of both common and idiosyncratic terms. One problem that exists in trying to create a list such as this is that much of the terminology used by a particular department is specifically defined in their particular standing operating procedures, such that two departments may have completely different terms for the same thing. For example, depending on whom one asks, a safety team may be referred to as a standby, a RIT or RIG or RIC, or a FAST. Furthermore, a department may change a definition within its SOP, such that one year it may be RIT, and the next RIG or RIC.

<span class="mw-page-title-main">Fire station</span> Structure for storage of firefighting apparatus

A fire station is a structure or other area for storing firefighting apparatuses such as fire engines and related vehicles, personal protective equipment, fire hoses and other specialized equipment. Fire stations frequently contain working and living space for the firefighters and support staff.

This is a glossary of firefighting equipment.

The New Zealand Fire Service was New Zealand's main firefighting body from 1 April 1976 until 1 July 2017 – at which point it was dissolved and incorporated into the new Fire and Emergency New Zealand.

<span class="mw-page-title-main">Wildland fire engine</span> Fire engine designed for fighting wildfires

A wildland fire engine or brush truck is a fire engine specifically designed to assist in fighting wildfires by transporting firefighters to the scene and providing them with access to the fire, along with water or other equipment. There are multiple types of wildfire apparatus which are used in different scenarios. According to the U.S. National Fire Protection Association, if the apparatus will be used primarily for outdoor and wildland responses, then it is to be considered a wildland fire apparatus and must conform to NFPA 1906.

<span class="mw-page-title-main">Wildland water tender</span>

A wildland water tender is a specialized vehicle capable of bringing water, foam, or dry chemicals to fire trucks in the field that are engaged on the fireline. Water tenders have a large truck mounted tank that carries a minimum 1,000 gallons and up to 4,000 gallons of water. These vehicles are specifically designed for fire fighting often with four-wheel drive, rugged suspension and high wheel clearance for mountainous dirt road conditions. According to the National Fire Protection Association, if the apparatus will be used primarily for outdoor and wildland responses, then it is to be considered a wildland fire apparatus and must conform to NFPA 1906.

As firefighting has a rich history throughout the world, traditions in this profession vary widely from country to country.

<span class="mw-page-title-main">Charleston Sofa Super Store fire</span> 2007 firefighter disaster in South Carolina, US

The Charleston Sofa Super Store fire disaster occurred on the evening of June 18, 2007, in Charleston, South Carolina, and killed nine firefighters. This was the deadliest firefighter disaster in the US since the September 11 attacks. Though the fire was believed to have started in some discarded furniture in the loading dock area, the exact source of ignition remains undetermined. After the fire, the store was demolished and bought by Charleston and a fire station was built nearby.

Firefighting is the act of extinguishing destructive fires. A firefighter fights these fires with the intent to prevent destruction of life, property and the environment. Firefighting is a highly technical profession, which requires years of training and education in order to become proficient. A fire can rapidly spread and endanger many lives; however, with modern firefighting techniques, catastrophe can usually be avoided. To help prevent fires from starting, a firefighter's duties include public education and conducting fire inspections. Because firefighters are often the first responders to victims in critical conditions, firefighters often also provide basic life support as emergency medical technicians or advanced life support as licensed paramedics. Firefighters make up one of the major emergency services, along with the emergency medical service, the police, and many others.

<span class="mw-page-title-main">Hard suction hose</span> Drafting fire hose made to withstand vacuum

Flexible suction hose, not to be confused with hard suction hose in U.S., is a specific type of fire hose used in drafting operations, when a fire engine uses a vacuum to draw water from a portable water tank, pool, or other static water source. It is built to withstand vacuum, rather than pressure, abrasion, and heat. Conversely, hard suction is capable of withstanding up to 200 PSIG, as well as vacuum. In the United States, it is standard equipment according to the National Fire Protection Association standards for fire engines. It is used in both structural and wildland firefighting throughout the world, and is made in various diameters and connection types.

<span class="mw-page-title-main">Fire appliances in the United Kingdom</span>

Fire services in the United Kingdom use a variety of fire appliances, which perform a wide range of general and specialised roles and fit into several distinct categories. Contemporary fire appliances carry a multitude of equipment and firefighting media to deal with different types of emergencies ranging from fires, rescues, vehicle extrication, floods, salvage, casualty and trauma care.

<span class="mw-page-title-main">Firefighting in the United States</span> Firefighting

Firefighting in the United States dates back to the earliest European colonies in the Americas. Early firefighters were simply community members who would respond to neighborhood fires with buckets. The first dedicated volunteer fire brigade was established in 1736 in Philadelphia. These volunteer companies were often paid by insurance companies in return for protecting their clients.

<span class="mw-page-title-main">Baltimore City Fire Department</span> Fire department in the United States

The Baltimore City Fire Department (BCFD) provides fire protection and emergency medical services to the city of Baltimore, Maryland, United States. Founded in 1797 and established in 1859, the Baltimore City Fire Department covers an area of 81 square miles (210 km2) of land and 11 square miles (28 km2) of water, with a resident population of over 640,000 and a daytime population of over 1,000,000. The BCFD responds to approximately 235,000 emergency calls annually. There are two International Association of Fire Fighters (IAFF) locals; IAFF 734 for firefighters and IAFF 964 for officers.

References

  1. "OSHA 29 CFR 1910.134(g)(4)(i) Procedures for interior structural firefighting". Occupational Safety and Health Administration.
  2. 1 2 "1910.134 - Respiratory Protection". www.osha.gov. US Occupational Safety and Health Administration. Retrieved 2021-03-22.PD-icon.svg This article incorporates text from this source, which is in the public domain .
  3. "NFPA 1500: Standard on Fire Department Occupational Safety and Health Program 2013 Edition". National Fire Protection Association. Retrieved 30 Jan 2013.[ permanent dead link ]
  4. FwDV 3 (pdf, German)
  5. FwDV 7 (pdf, German)