Stage pin connector

Last updated
A newer stage pin connector. Note the GR denoting the longer ground pin, which is slightly off-center to prevent the plug being inserted upside down. Stage pin connector .jpg
A newer stage pin connector. Note the GR denoting the longer ground pin, which is slightly off-center to prevent the plug being inserted upside down.

A stage pin connector, also known as a grounded stage pin (GSP), grounded pin connector (GPC) or theater paddle (TP), is a standard cable type for theatrical lighting in North America and in many countries in the theatre world. [1]

Contents

Uses

Stage pin connectors are generally used for conducting dimmed power from a dimmer to stage lighting instruments, although occasionally they can power other equipment.

Construction

The first stage pin connectors had two cylindrical pins, one for line (hot) and one for neutral, arranged symmetrically in a rectangular housing. The housing was milled from a solid block of fiberglass or bakelite which may have been impregnated with asbestos for fire resistance, with a screw-on cover. Later connectors (including those currently manufactured) use molded plastic or machined phenolic resin laminate housings .

These two-pin connectors were not polarized, and thus the line and neutral conductors could be exchanged depending on which way the connectors were mated. Two-pin connectors may still be found on some equipment and are often saved by electricians for wiring ungrounded fixtures (particularly practicals), though this may not be advisable from a safety standpoint.

Modern stage pin connectors have incorporated a third pin for a safety ground connection and are commonly referred to as two pin and ground (2P&G) to distinguish them from their ungrounded two-pin predecessors. The ground pin is situated between the line and neutral pins and closer to the latter for 20 A connectors. This asymmetrical configuration effectively polarizes the connector ensuring that the line and neutral conductors are not exchanged in a properly wired installation. The ground pin is also longer than the other two, ensuring that the safety ground connection is made first when making a connection.

All stage pin connectors have longitudinal slits in the male pins that allow for compression when inserted into the female sockets to increase friction and therefore the mechanical security of the connection. A special tool appropriately called a pin splitter may be used to expand this slit and spread the two halves of the pin to compensate for wear. A knife may be used to the same effect, but this technique risks both personal injury, damage to the connector, or ruining of the knife blade. For these reasons, a flat-head screwdriver is often used as an impromptu pin splitter.

For some time Union Connector produced 2P&G connectors with a distinctive yellow cover that featured a locking tab in the ground pin that provided a positive mechanical lock to prevent accidental disengagement of the connectors. This design required special connectors on both the male and female side in order to work, meaning that all connectors in an installation would need to be replaced to see a real benefit to the locking feature. The expense of this proposition as well as the unpopularity of the connector itself among technicians led the locking feature to eventually be dropped, and locking connectors are no longer manufactured. The locking connectors that are still found occasionally in installations or spare parts bins are often referred to as "Union Connectors", though the Union Connector brand now features only standard non-locking stage pin connectors.

Since their introduction, stage pin connectors have been available in 20 A, 30 A, 60 A, and 100 A varieties, [1] with the higher-current connectors being not only far larger in size but also with a different pin configuration for ground, neutral and line. Care must be taken when repairing or building these larger connectors, because ground is on the outside pin and neutral is in the middle, with the far pin still being the line.

Cabling

Extension cables

Most extension cables made with 20 A stage pin connectors use 12/3 type SOOW or SJOOW cable which has three individually insulated 12 awg (American Wire Gauge) stranded conductors inside a larger jacket. The internal insulation is usually colored black (for line), white (for neutral) and green(for ground). This cable configuration can safely handle the full 20 ampere rating of the connector. The designation SOOW or SJOOW refers to the cable's insulation construction and type. SJ— (300 volts, maximum) and S— (600 volts, maximum) are both "most severe" service cordage. This type of cable is very hard-wearing, resistant to oil and moisture, and resists the kinking that can result in internal conductors unlaying and twisting, which is a common problem with the SJTW cable often used in household-grade extension cords. However, older cable made using natural rubber is susceptible to dry-rotting, particularly with the heat generated by lighting equipment. This can cause the insulation to fail and expose or short circuit the conductors leading to shock or fire hazard if old cable is not inspected regularly and replaced as needed.

Multicircuit cable

Some stage pin extension cables may be constructed from cable with six or more conductors. This cable can be fitted with multiple stage-pin connectors at either end enabling the single cable to carry multiple independent output channels of dimmed power. Each channel or circuit should have its own line, ground, and neutral conductor independent of the other circuits, though in some cases the ground or neutral lines may be shared among circuits.

Alternatively, multicircuit cables may terminate in multicircuit ( socapex ) connectors which may in turn be mated to panel-mount multicircuit connectors on dimming equipment or distribution boxes, other multicircuit cables (to increase length), or break-in/break-out adapters to convert the multicircuit connection to a set of stage pin connections.

Equipment cabling

The cables integrally connected to lighting instruments (often referred to as pigtails) may use 3-conductor SJOOW or SOOW cable or individual high-temperature wires inside of a fiberglass sleeve. In either case, the cable is often smaller gauge and sized to the current rating of the equipment it services.

Adapters

Twofers are used to connect two devices to a single source. They may be constructed using individual wires inside of a fiberglass sleeve or 12/3 cable, though the latter type tends to be harder to construct and more prone to failure.

In some situations it may be desirable to connect an Edison-equipped device to a stage-pin source, such as when using a household fixture as an on-stage practical. Or it may be desirable to connect a stage pin-equipped device to an Edison source, for testing purposes or applications such as using theatrical equipment for architectural or retail displays. In either case, adapters may be constructed with a female Edison connector and a male stage pin connector or vice versa.

Some facilities feature 60 or 100 ampere circuits which have larger versions of the stage pin connector to match the higher current rating. Since it is unusual to require more than 20 amperes on a single circuit with modern lighting equipment, adapters may be made to convert a single 60 or 100 ampere stage pin connection to three to five 20 ampere stage pin connections. However, each downstream connection must be independently protected by a fuse or breaker to avoid exceeding the current rating of downstream cables and connectors.

Stage pin versus NEMA 5-15 (Edison) connectors

The primary advantage of the stage pin connector over the NEMA 5-15 connector (commonly known as an Edison plug) is its ability to lie flat on a stage lessening the likelihood of being a trip hazard. In addition the stage pin connector has an increased durability and resistance to damage due to its more robust construction and the ability to compensate for wear with a pin splitter. Having a distinct connector designated for dimmable power also helps prevent confusion of dimmed and non-dimmed circuits which could lead to equipment damage. Even the smallest stage pin connectors are rated for 20 A, which translates to 2.4 kW at 120 V, compared to the 15 A and 1.8 kW of the NEMA 5-15.

Despite the advantages of stage pin connectors, many smaller installations use Edison connectors due to their availability and the ease of connecting equipment to outlets already available in a building. This reduces refit costs, particularly when small portable dimming packs (often 4×1.2 kW channel models) are used. Such installations may also use inexpensive store-bought extension cables, though care must be taken to ensure that the ratings of such extension cables are not exceeded.

Though the initial cost of constructing a 12/3 stage pin extension cable is higher than simply purchasing an equivalent Edison extension cable, the maintenance costs of the former are ultimately lower for several reasons. To begin with, less maintenance will be required as a result of the more rugged construction. When maintenance is required, many cable faults may be repaired by disassembling the connector, replacing broken components with spares acquired by cannibalizing other broken connectors, trimming away defective sections of cable, and reapplying the connector to the cable. This sort of repair is not usually possible with Edison connectors, particularly the factory-molded type. If a connector is beyond repair, a new stage pin connector is often less expensive than a replacement Edison connector when purchased from local vendors.

Safety

Though stage pin connectors are usually used in part to distinguish dimmed circuits from non-dimmed Edison circuits, newer theatrical installations may have several dimmed circuits that terminate in Edison outlets at various locations for convenience; thus care must be taken to avoid using these circuits for non-dimmable equipment. Connecting certain non-dimmable appliances or equipment to dimmed circuits may result in damage to the dimming equipment or the downstream device.

Most modern stage pin connectors feature a ground pin that is longer than the line and neutral pins, ensuring that the ground connection is made first, and thus the safety ground is in place before line voltage is applied to the downstream equipment.

As an added precaution, some SPCs are built with a clear housing on one side. This allows a user to confirm that they are wired correctly before connecting them.

On some older female pin receptacles, the electrical contacts are not deeply recessed in the plug body and can easily be accidentally contacted resulting in an electric shock if the circuit is live. This was one advantage of the Edison outlet in that it was impossible to contact live parts unless something conductive was inserted into the slots. New connectors have the contacts deeper inside the body.

A major disadvantage to this style of connector is that it can be mated with one connector reversed, reversing ground and line connections. For equipment mechanically attached to grounded building structures such as a lighting instrument mounted to a batten or grid this will cause a line-ground short circuit. For equipment not attached to a building ground, such as a floor-mounted lighting instrument, this condition will cause the chassis of the equipment to become electrified creating a shock hazard. Care must therefore be taken to avoid misaligning plugs. It is also possible to mate stage pin connectors such that the ground pin is inserted into the neutral socket and the neutral pin is inserted into the ground socket, but this mistake does not usually result in a fault condition unless there is a hot-neutral reverse upstream in the cabling.

Standards

Stage pin connectors are specified by Entertainment Services and Technology Association (ESTA) standard"ANSI E1.24 – 2012 (R2017) Entertainment Technology Dimensional Requirements for Stage Pin Connectors" [2]

Other connectors used in theatre applications

Many theatres also use NEMA connectors, which are the standard connector used in homes and businesses in North America, because of their availability and the ability to connect household fixtures to a theatrical control system. Twist-lock connectors are used in many theatres because of their locking feature, which will not allow fixtures to become accidentally disconnected. Connectors used to power lighting fixtures must be rated at 20 amperes or higher, depending on local electrical codes. Temporary high-power distribution wiring often employs camlock connectors to connect dimming equipment, power distribution units, controllers for motorized chain hoists, and other high-power equipment to a company switch, generator, or other tie-in point.

For individual dimmable lighting fixtures, UK theatrical lighting installations normally use the BS 546 type plug rated at 15 A (the higher phase voltage of 230 V allows lower currents for the same power) or occasionally IEC 60309 16 A industrial plugs.

See also

Related Research Articles

<span class="mw-page-title-main">Direct current</span> Unidirectional flow of electric charge

Direct current (DC) is one-directional flow of electric charge. An electrochemical cell is a prime example of DC power. Direct current may flow through a conductor such as a wire, but can also flow through semiconductors, insulators, or even through a vacuum as in electron or ion beams. The electric current flows in a constant direction, distinguishing it from alternating current (AC). A term formerly used for this type of current was galvanic current.

<span class="mw-page-title-main">600 series connector</span>

A 600 series connector is an obsolete three-pin connector with up to six conductors.

<span class="mw-page-title-main">Electrical connector</span> Device used to join electrical conductors

Components of an electrical circuit are electrically connected if an electric current can run between them through an electrical conductor. An electrical connector is an electromechanical device used to create an electrical connection between parts of an electrical circuit, or between different electrical circuits, thereby joining them into a larger circuit. Most electrical connectors have a gender – i.e. the male component, called a plug, connects to the female component, or socket. The connection may be removable, require a tool for assembly and removal, or serve as a permanent electrical joint between two points. An adapter can be used to join dissimilar connectors.

Balanced audio is a method of interconnecting audio equipment using balanced interfaces. This type of connection is very important in sound recording and production because it allows the use of long cables while reducing susceptibility to external noise caused by electromagnetic interference. The balanced interface guarantees that induced noise appears as common-mode voltages at the receiver which can be rejected by a differential device.

<span class="mw-page-title-main">DMX512</span> Digital communication network standard for controlling stage lighting and effects

DMX512 is a standard for digital communication networks that are commonly used to control lighting and effects. It was originally intended as a standardized method for controlling stage lighting dimmers, which, prior to DMX512, had employed various incompatible proprietary protocols. It quickly became the primary method for linking controllers to dimmers and special effects devices such as fog machines and intelligent lights.

<span class="mw-page-title-main">Registered jack</span> Telecommunication network interface

A registered jack (RJ) is a standardized telecommunication network interface for connecting voice and data equipment to a service provided by a local exchange carrier or long distance carrier. Registered interfaces were first defined in the Universal Service Ordering Code (USOC) system of the Bell System in the United States for complying with the registration program for customer-supplied telephone equipment mandated by the Federal Communications Commission (FCC) in the 1970s. They were subsequently codified in title 47 of the Code of Federal Regulations Part 68. Registered jack connections began to see use after their invention in 1973 by Bell Labs. The specification includes physical construction, wiring, and signal semantics. Accordingly, registered jacks are primarily named by the letters RJ, followed by two digits that express the type. Additional letter suffixes indicate minor variations. For example, RJ11, RJ14, and RJ25 are the most commonly used interfaces for telephone connections for one-, two-, and three-line service, respectively. Although these standards are legal definitions in the United States, some interfaces are used worldwide.

<span class="mw-page-title-main">DIN connector</span> Electrical connector

The DIN connector is an electrical connector that was standardized by the Deutsches Institut für Normung (DIN), the German Institute for Standards, in the mid 1950's, initial with 3 pins for mono, but when stereo connections and gear appeared in late 1950's, versions with 5 pins or more were launched. The male DIN connectors (plugs) feature a 13.2 mm diameter metal shield with a notch that limits the orientation in which plug and socket can mate. The range of DIN connectors, different only in the configuration of the pins, have been standardized as DIN 41524 / IEC/DIN EN 60130-9 ; DIN 45322 ; DIN 45329 / IEC/DIN EN 60130–9 ; and DIN 45326 / IEC/DIN EN 60130-9.

<span class="mw-page-title-main">Power cord</span> Electrical cable that connects an appliance to the electricity supply via a wall socket

A power cord, line cord, or mains cable is an electrical cable that temporarily connects an appliance to the mains electricity supply via a wall socket or extension cord. The terms are generally used for cables using a power plug to connect to a single-phase alternating current power source at the local line voltage. The terms power cable, mains lead, flex or kettle lead are also used. A lamp cord is a light-weight, ungrounded, single-insulated two-wire cord used for small loads such as a table or floor lamp.

Electrical wiring in North America follows the regulations and standards applicable at the installation location. It is also designed to provide proper function, and is also influenced by history and traditions of the location installation.

A distribution board is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure. Normally, a main switch, and in recent boards, one or more residual-current devices (RCDs) or residual current breakers with overcurrent protection (RCBOs) are also incorporated.

AC power plugs and sockets connect electric equipment to the alternating current (AC) mains electricity power supply in buildings and at other sites. Electrical plugs and sockets differ from one another in voltage and current rating, shape, size, and connector type. Different standard systems of plugs and sockets are used around the world.

In an electrical system, a ground loop or earth loop occurs when two points of a circuit are intended to have the same ground reference potential but instead have a different potential between them. This is typically caused when enough current is flowing in the connection between the two ground points to produce a voltage drop and cause two points to be at different potentials. Current may be produced in a circular ground connection by electromagnetic induction.

<span class="mw-page-title-main">Industrial and multiphase power plugs and sockets</span>

Industrial and multiphase plugs and sockets provide a connection to the electrical mains rated at higher voltages and currents than household plugs and sockets. They are generally used in polyphase systems, with high currents, or when protection from environmental hazards is required. Industrial outlets may have weatherproof covers, waterproofing sleeves, or may be interlocked with a switch to prevent accidental disconnection of an energized plug. Some types of connectors are approved for hazardous areas such as coal mines or petrochemical plants, where flammable gas may be present.

In electrical engineering, ground and neutral are circuit conductors used in alternating current (AC) electrical systems. The ground circuit is connected to earth, and neutral circuit is usually connected to ground. As the neutral point of an electrical supply system is often connected to earth ground, ground and neutral are closely related. Under certain conditions, a conductor used to connect to a system neutral is also used for grounding (earthing) of equipment and structures. Current carried on a grounding conductor can result in objectionable or dangerous voltages appearing on equipment enclosures, so the installation of grounding conductors and neutral conductors is carefully defined in electrical regulations. Where a neutral conductor is used also to connect equipment enclosures to earth, care must be taken that the neutral conductor never rises to a high voltage with respect to local ground.

<span class="mw-page-title-main">Electrical wiring</span> Electrical installation of cabling

Electrical wiring is an electrical installation of cabling and associated devices such as switches, distribution boards, sockets, and light fittings in a structure.

An earthing system or grounding system (US) connects specific parts of an electric power system with the ground, typically the Earth's conductive surface, for safety and functional purposes. The choice of earthing system can affect the safety and electromagnetic compatibility of the installation. Regulations for earthing systems vary among countries, though most follow the recommendations of the International Electrotechnical Commission (IEC). Regulations may identify special cases for earthing in mines, in patient care areas, or in hazardous areas of industrial plants.

<span class="mw-page-title-main">Camlock (electrical)</span> High-current power connector

A camlock or cam-lock is an interchangeable electrical connector, often used in temporary electrical power production and distribution, predominantly in North America. Originally a trade name as Cam-Lok, it is now a generic term. Each camlock connector carries a single phase, pole, or conductor; multiple camlock connectors will be used to make a complete electrical supply or circuit.

<span class="mw-page-title-main">NEMA connector</span> Power plugs and receptacles used in North America and some other regions

NEMA connectors are power plugs and receptacles used for AC mains electricity in North America and other countries that use the standards set by the US National Electrical Manufacturers Association. NEMA wiring devices are made in current ratings from 15 to 60 amperes (A), with voltage ratings from 125 to 600 volts (V). Different combinations of contact blade widths, shapes, orientations, and dimensions create non-interchangeable connectors that are unique for each combination of voltage, electric current carrying capacity, and grounding system.

<span class="mw-page-title-main">Socapex</span> Brand of electrical connector

Socapex is a brand of electrical connectors, known in the entertainment industry primarily for their 19-pin electrical connectors, commonly known as Socapex connectors, and used in film, television, and stage lighting to terminate the ends of a multicable. They are wired with six hot/live pins, six neutral pins, six ground/earth pins, and a final central pin used to aid alignment of the male end of the connector with a female receptacle. The Socapex was first created by a company called Socapex in 1961, which later on became Amphenol Socapex. "Socapex" became a brand name owned by Amphenol Socapex, the term "Soca" is now often applied to similar off-brand connectors as a genericized trademark.

<span class="mw-page-title-main">AC power plugs and sockets: British and related types</span> AC power plug type

Plugs and sockets for electrical appliances not hardwired to mains electricity originated in the United Kingdom in the 1870s and were initially two-pin designs. These were usually sold as a mating pair, but gradually de facto and then official standards arose to enable the interchange of compatible devices. British standards have proliferated throughout large parts of the former British Empire.

References

  1. 1 2 Richard Cadena, Electricity for the Entertainment Electrician & Technician, Focal Press, 2009 ( ISBN   0-240-80995-5).
  2. "ANSI E1.24-2012 (R2017) - Entertainment Technology - Dimensional Requirements for Stage Pin Connectors".