Infrared multiphoton dissociation

Last updated
Infrared multiple photon dissociation
AcronymIRMPD
Other techniques
Related Blackbody infrared radiative dissociation
Electron capture dissociation
Collision-induced dissociation

Infrared multiple photon dissociation (IRMPD) is a technique used in mass spectrometry to fragment molecules in the gas phase usually for structural analysis of the original (parent) molecule. [1]

Contents

How it works

An infrared laser is directed through a window into the vacuum of the mass spectrometer where the ions are. The mechanism of fragmentation involves the absorption by a given ion of multiple infrared photons. The parent ion becomes excited into more energetic vibrational states until a bond(s) is broken resulting in gas phase fragments of the parent ion. In the case of powerful laser pulses, the dissociation proceeds via inner-valence ionization of electrons. [2] [3]

IRMPD is most often used in Fourier transform ion cyclotron resonance mass spectrometry. [4]

Infrared photodissociation spectroscopy

By applying intense tunable IR lasers, like IR-OPOs or IR free electron lasers, the wavelength dependence of the IRMPD yield can be studied. [5] [6] This infrared photodissociation spectroscopy allows for the measurement of vibrational spectra of (unstable) species that can only be prepared in the gas phase. Such species include molecular ions but also neutral species like metal clusters that can be gently ionized after interaction with the IR light for their mass spectrometric detection. [7]

Analytical applications

The combination of mass spectrometry and IRMPD with tunable lasers (IR ion spectroscopy) is increasingly recognized as a powerful tool for small-molecule identification. [8] Examples are metabomics, where biomarkers are identified in body fluids (urine, blood, cerebrospinal) [9] and forensic sciences, where isomeric designer drugs were identified in seized samples. [10]

Isotope separation

Due to the relatively large differences in IR absorption frequencies that are due to different resonance frequencies for molecules containing different isotopes, this technique has been suggested as a way to perform Isotope separation with difficult-to-separate isotopes, in a single pass. For example, molecules of UF6 containing U-235 might be ionized completely as a result of such a laser resonance, leaving UF6 containing the heavier U-238 intact.

See also

Related Research Articles

<span class="mw-page-title-main">Ionization</span> Process by which atoms or molecules acquire charge by gaining or losing electrons

Ionization is the process by which an atom or a molecule acquires a negative or positive charge by gaining or losing electrons, often in conjunction with other chemical changes. The resulting electrically charged atom or molecule is called an ion. Ionization can result from the loss of an electron after collisions with subatomic particles, collisions with other atoms, molecules and ions, or through the interaction with electromagnetic radiation. Heterolytic bond cleavage and heterolytic substitution reactions can result in the formation of ion pairs. Ionization can occur through radioactive decay by the internal conversion process, in which an excited nucleus transfers its energy to one of the inner-shell electrons causing it to be ejected.

<span class="mw-page-title-main">Mass spectrometry</span> Analytical technique based on determining mass to charge ratio of ions

Mass spectrometry (MS) is an analytical technique that is used to measure the mass-to-charge ratio of ions. The results are presented as a mass spectrum, a plot of intensity as a function of the mass-to-charge ratio. Mass spectrometry is used in many different fields and is applied to pure samples as well as complex mixtures.

<span class="mw-page-title-main">Ion source</span> Device that creates charged atoms and molecules (ions)

An ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines.

<span class="mw-page-title-main">Electron ionization</span> Ionization technique

Electron ionization is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard ionization method, since it uses highly energetic electrons to produce ions. This leads to extensive fragmentation, which can be helpful for structure determination of unknown compounds. EI is the most useful for organic compounds which have a molecular weight below 600. Also, several other thermally stable and volatile compounds in solid, liquid and gas states can be detected with the use of this technique when coupled with various separation methods.

<span class="mw-page-title-main">Tandem mass spectrometry</span> Type of mass spectrometry

Tandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more stages of analysis using one or more mass analyzer are performed with an additional reaction step in between these analyses to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides.

<span class="mw-page-title-main">Photoionization</span> Ion formation via a photon interacting with a molecule or atom

Photoionization is the physical process in which an ion is formed from the interaction of a photon with an atom or molecule.

Fourier-transform ion cyclotron resonance mass spectrometry is a type of mass analyzer (or mass spectrometer) for determining the mass-to-charge ratio (m/z) of ions based on the cyclotron frequency of the ions in a fixed magnetic field. The ions are trapped in a Penning trap (a magnetic field with electric trapping plates), where they are excited (at their resonant cyclotron frequencies) to a larger cyclotron radius by an oscillating electric field orthogonal to the magnetic field. After the excitation field is removed, the ions are rotating at their cyclotron frequency in phase (as a "packet" of ions). These ions induce a charge (detected as an image current) on a pair of electrodes as the packets of ions pass close to them. The resulting signal is called a free induction decay (FID), transient or interferogram that consists of a superposition of sine waves. The useful signal is extracted from this data by performing a Fourier transform to give a mass spectrum.

<span class="mw-page-title-main">Matrix-assisted laser desorption/ionization</span> Ionization technique

In mass spectrometry, matrix-assisted laser desorption/ionization (MALDI) is an ionization technique that uses a laser energy-absorbing matrix to create ions from large molecules with minimal fragmentation. It has been applied to the analysis of biomolecules and various organic molecules, which tend to be fragile and fragment when ionized by more conventional ionization methods. It is similar in character to electrospray ionization (ESI) in that both techniques are relatively soft ways of obtaining ions of large molecules in the gas phase, though MALDI typically produces far fewer multi-charged ions.

<span class="mw-page-title-main">Electron-capture dissociation</span>

Electron-capture dissociation (ECD) is a method of fragmenting gas-phase ions for structure elucidation of peptides and proteins in tandem mass spectrometry. It is one of the most widely used techniques for activation and dissociation of mass selected precursor ion in MS/MS. It involves the direct introduction of low-energy electrons to trapped gas-phase ions.

<span class="mw-page-title-main">History of mass spectrometry</span>

The history of mass spectrometry has its roots in physical and chemical studies regarding the nature of matter. The study of gas discharges in the mid 19th century led to the discovery of anode and cathode rays, which turned out to be positive ions and electrons. Improved capabilities in the separation of these positive ions enabled the discovery of stable isotopes of the elements. The first such discovery was with the element neon, which was shown by mass spectrometry to have at least two stable isotopes: 20Ne and 22Ne. Mass spectrometers were used in the Manhattan Project for the separation of isotopes of uranium necessary to create the atomic bomb.

<span class="mw-page-title-main">Triple quadrupole mass spectrometer</span>

A triple quadrupole mass spectrometer (TQMS), is a tandem mass spectrometer consisting of two quadrupole mass analyzers in series, with a (non-mass-resolving) radio frequency (RF)–only quadrupole between them to act as a cell for collision-induced dissociation. This configuration is often abbreviated QqQ, here Q1q2Q3.

<span class="mw-page-title-main">Instrumental chemistry</span> Study of analytes using scientific instruments

Instrumental analysis is a field of analytical chemistry that investigates analytes using scientific instruments.

<span class="mw-page-title-main">Fragmentation (mass spectrometry)</span>

In mass spectrometry, fragmentation is the dissociation of energetically unstable molecular ions formed from passing the molecules mass spectrum. These reactions are well documented over the decades and fragmentation patterns are useful to determine the molar weight and structural information of unknown molecules. Fragmentation that occurs in tandem mass spectrometry experiments has been a recent focus of research, because this data helps facilitate the identification of molecules.

<span class="mw-page-title-main">Collision-induced dissociation</span> Mass spectrometry technique to induce fragmentation of selected ions in the gas phase

Collision-induced dissociation (CID), also known as collisionally activated dissociation (CAD), is a mass spectrometry technique to induce fragmentation of selected ions in the gas phase. The selected ions are usually accelerated by applying an electrical potential to increase the ion kinetic energy and then allowed to collide with neutral molecules. In the collision, some of the kinetic energy is converted into internal energy which results in bond breakage and the fragmentation of the molecular ion into smaller fragments. These fragment ions can then be analyzed by tandem mass spectrometry.

Atmospheric pressure laser ionization is an atmospheric pressure ionization method for mass spectrometry (MS). Laser light in the UV range is used to ionize molecules in a resonance-enhanced multiphoton ionization (REMPI) process. It is a selective and sensitive ionization method for aromatic and polyaromatic compounds. Atmospheric photoionization is the latest in development of atmospheric ionization methods.

Photoelectron photoion coincidence spectroscopy (PEPICO) is a combination of photoionization mass spectrometry and photoelectron spectroscopy. It is largely based on the photoelectric effect. Free molecules from a gas-phase sample are ionized by incident vacuum ultraviolet (VUV) radiation. In the ensuing photoionization, a cation and a photoelectron are formed for each sample molecule. The mass of the photoion is determined by time-of-flight mass spectrometry, whereas, in current setups, photoelectrons are typically detected by velocity map imaging. Electron times-of-flight are three orders of magnitude smaller than those of ions, which allows electron detection to be used as a time stamp for the ionization event, starting the clock for the ion time-of-flight analysis. In contrast with pulsed experiments, such as REMPI, in which the light pulse must act as the time stamp, this allows to use continuous light sources, e.g. a discharge lamp or a synchrotron light source. No more than several ion–electron pairs are present simultaneously in the instrument, and the electron–ion pairs belonging to a single photoionization event can be identified and detected in delayed coincidence.

The magnesium argide ion, MgAr+ is an ion composed of one ionised magnesium atom, Mg+ and an argon atom. It is important in inductively coupled plasma mass spectrometry and in the study of the field around the magnesium ion. The ionization potential of magnesium is lower than the first excitation state of argon, so the positive charge in MgAr+ will reside on the magnesium atom. Neutral MgAr molecules can also exist in an excited state.

<span class="mw-page-title-main">Infrared photodissociation spectroscopy</span>

Infrared photodissociation (IRPD) spectroscopy uses infrared radiation to break bonds in, often ionic, molecules (photodissociation), within a mass spectrometer. In combination with post-ionization, this technique can also be used for neutral species. IRPD spectroscopy has been shown to use electron ionization, corona discharge, and electrospray ionization to obtain spectra of volatile and nonvolatile compounds. Ionized gases trapped in a mass spectrometer can be studied without the need of a solvent as in infrared spectroscopy.

References

  1. Little DP, Speir JP, Senko MW, O'Connor PB, McLafferty FW (1994). "Infrared multiphoton dissociation of large multiply charged ions for biomolecule sequencing". Anal. Chem. 66 (18): 2809–15. doi:10.1021/ac00090a004. PMID   7526742.
  2. Talebpour A, Bandrauk AD, Yang J, Chin SL (1999). "Multiphoton ionization of inner-valence electrons and fragmentation of ethylene in an intense Ti:sapphire laser pulse". Chemical Physics Letters. 313 (5–6): 789–794. Bibcode:1999CPL...313..789T. doi:10.1016/s0009-2614(99)01075-1.
  3. Talebpour A, Bandrauk AD, Vijayalakshmi K, Chin SL (2000). "Dissociative ionization of benzene in intense ultra-fast laser pulses". Journal of Physics B: Atomic, Molecular and Optical Physics. 33 (21): 4615–4626. Bibcode:2000JPhB...33.4615T. doi:10.1088/0953-4075/33/21/307.
  4. Laskin J, Futrell JH (2005). "Activation of large ions in FT-ICR mass spectrometry". Mass Spectrometry Reviews. 24 (2): 135–67. Bibcode:2005MSRv...24..135L. doi:10.1002/mas.20012. PMID   15389858.
  5. Polfer NC, Oomens J (2007). "Reaction products in mass spectrometry elucidated with infrared spectroscopy". Physical Chemistry Chemical Physics. 9 (29): 3804–17. Bibcode:2007PCCP....9.3804P. doi:10.1039/b702993b. PMID   17637973. S2CID   23485300.
  6. Fielicke, André (2023). "Probing the binding and activation of small molecules by gas-phase transition metal clusters via IR spectroscopy". Chemical Society Reviews. 52 (11): 3778–3841. doi: 10.1039/D2CS00104G . ISSN   0306-0012.
  7. Gruene P, Rayner DM, Redlich B, van der Meer AF, Lyon JT, Meijer G, Fielicke A (2008). "Structures of Neutral Au7, Au19, and Au20 Clusters in the Gas Phase". Science. 321 (5889): 674–6. Bibcode:2008Sci...321..674G. doi:10.1126/science.1161166. hdl: 11858/00-001M-0000-0010-FC2A-A . PMID   18669858.
  8. Martens J, van Outersterp RE, Vreeken RJ, Cuyckens F, Coene KL, Engelke UF, et al. (January 2020). "Infrared ion spectroscopy: New opportunities for small-molecule identification in mass spectrometry - A tutorial perspective". Analytica Chimica Acta. 1093: 1–15. doi:10.1016/j.aca.2019.10.043. hdl: 2066/212342 . PMID   31735202.
  9. Martens J, Berden G, van Outersterp RE, Kluijtmans LA, Engelke UF, van Karnebeek CD, et al. (June 2017). "Molecular identification in metabolomics using infrared ion spectroscopy". Scientific Reports. 7 (1): 3363. doi:10.1038/s41598-017-03387-4. PMC   5469762 . PMID   28611404.
  10. van Geenen FA, Kranenburg RF, van Asten AC, Martens J, Oomens J, Berden G (February 2021). "Isomer-Specific Two-Color Double-Resonance IR2MS3 Ion Spectroscopy Using a Single Laser: Application in the Identification of Novel Psychoactive Substances". Analytical Chemistry. 93 (4): 2687–2693. doi:10.1021/acs.analchem.0c05042. PMC   7859929 . PMID   33470107.