LaMont boiler

Last updated
Schematic Diagram of La Mont Boiler.jpg

A LaMont boiler is a type of forced circulation water-tube boiler [1] in which the boiler water is circulated through an external pump through long closely spaced tubes of small diameter. The mechanical pump is employed in order to have an adequate and positive circulation in steam and hot water boilers.

Contents

History

Martin Benson was the first to work on the idea of forced circulation drum boilers. [2] In 1918, Walter Douglas La Mont  [ de ] brought the forced circulation boiler from concept into existence. [3] La Mont was a Lieutenant Commander and an engineer in the US Navy. He died of a heart attack in 1942 in New York. [4]

La Mont's initial designs confirmed the lighter, safer and higher rates of heat transfer and evaporation per square foot as compared to that of the standard water tube boilers, also the circulation of vaporized water at a differential pressure of 2.5 bar was 8 to 10 times greater. [5] The time needed for a La Mont Boiler to be able to deliver an evaporation rate of 100,000 pounds per hour was between 15 and 20 minutes. During World War II the U.S. Navy mainly relied upon Babcock & Wilcox boilers which were used commonly at the time. On the other hand, thousands were built in Europe and several German and Japanese ships used La Mont boilers.

Principle

The circulation of water and steam mixture takes with the help of an external pump which supplies water at a higher pressure than in a natural circulation boiler.

Working

A centrifugal pump which forms the heart of this boiler is responsible to circulate water within the boiler system. It receives water from the drum and delivers this water to a distribution header as shown in the diagram here. The number of headers may differ in numbers and depends on the size and boiler design of each boiler.

The boiler heating surfaces includes a number of tubes arranged in a parallel form and the inlet ends are welded to the distributors or the headers. A circulation pressure is to be provided during the installation of the pump as per the boiler design and it should be sufficient to over come the resistance offered by the tubes. An even circulation takes place with the helps of the inlet nozzles provided at the inlet of tubes which creates the differential pressure adequate to cover the variations occurring at fluctuating loads or uneven firing conditions. The riser tubes outlet is welded to the collector headers and also directly to the drum containing steam and water .

See also

Related Research Articles

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

<span class="mw-page-title-main">Boiler</span> Closed vessel in which fluid is heated

A boiler is a closed vessel in which fluid is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, including water heating, central heating, boiler-based power generation, cooking, and sanitation.

<span class="mw-page-title-main">Chiller</span> Machine that removes heat from a liquid coolant via vapor compression

A chiller is a machine that removes heat from a liquid coolant via a vapor-compression, adsorption refrigeration, or absorption refrigeration cycles. This liquid can then be circulated through a heat exchanger to cool equipment, or another process stream. As a necessary by-product, refrigeration creates waste heat that must be exhausted to ambience, or for greater efficiency, recovered for heating purposes. Vapor compression chillers may use any of a number of different types of compressors. Most common today are the hermetic scroll, semi-hermetic screw, or centrifugal compressors. The condensing side of the chiller can be either air or water cooled. Even when liquid cooled, the chiller is often cooled by an induced or forced draft cooling tower. Absorption and adsorption chillers require a heat source to function.

<span class="mw-page-title-main">Injector</span> Type of pump using high pressure fluid to entrain a lower pressure fluid

An injector is a system of ducting and nozzles used to direct the flow of a high-pressure fluid in such a way that a lower pressure fluid is entrained in the jet and carried through a duct to a region of higher pressure. It is a fluid-dynamic pump with no moving parts except a valve to control inlet flow.

<span class="mw-page-title-main">Water-tube boiler</span> Type of furnace generating steam

A high pressure watertube boiler is a type of boiler in which water circulates in tubes heated externally by the fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes. In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled tubes that make up the walls of the furnace to generate steam.

<span class="mw-page-title-main">Thermal power station</span> Power plant that generates electricity from heat energy

A thermal power station is a type of power station in which heat energy is converted to electrical energy. In a steam-generating cycle heat is used to boil water in a large pressure vessel to produce high-pressure steam, which drives a steam turbine connected to an electrical generator. The low-pressure exhaust from the turbine enters a steam condenser where it is cooled to produce hot condensate which is recycled to the heating process to generate more high pressure steam. This is known as a Rankine cycle.

<span class="mw-page-title-main">Surface condenser</span> Steam engine component

A surface condenser is a water-cooled shell and tube heat exchanger installed to condense exhaust steam from a steam turbine in thermal power stations. These condensers are heat exchangers which convert steam from its gaseous to its liquid state at a pressure below atmospheric pressure. Where cooling water is in short supply, an air-cooled condenser is often used. An air-cooled condenser is however, significantly more expensive and cannot achieve as low a steam turbine exhaust pressure as a water-cooled surface condenser.

<span class="mw-page-title-main">Steam-electric power station</span>

The steam-electric power station is a power station in which the electric generator is steam driven. Water is heated, turns into steam and spins a steam turbine which drives an electrical generator. After it passes through the turbine, the steam is condensed in a condenser. The greatest variation in the design of steam-electric power plants is due to the different fuel sources.

<span class="mw-page-title-main">Vapor-compression evaporation</span> Evaporation method

Vapor-compression evaporation is the evaporation method by which a blower, compressor or jet ejector is used to compress, and thus, increase the pressure of the vapor produced. Since the pressure increase of the vapor also generates an increase in the condensation temperature, the same vapor can serve as the heating medium for its "mother" liquid or solution being concentrated, from which the vapor was generated to begin with. If no compression was provided, the vapor would be at the same temperature as the boiling liquid/solution, and no heat transfer could take place.

<span class="mw-page-title-main">Boiler (power generation)</span> High pressure steam generator

A boiler or steam generator is a device used to create steam by applying heat energy to water. Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure but, at pressures above this, it is more usual to speak of a steam generator.

<span class="mw-page-title-main">High Marnham Power Station</span> Former coal-fired power station in England

High Marnham Power Station was a coal fuelled power station in Nottinghamshire, to the west of the River Trent, approximately 0.5 miles (0.8 km) north of the village of Marnham. Construction began in 1954, power generation commenced in 1959, and the station became fully operational in 1962. The plant operated until 2003 when it was decommissioned, though the cooling towers weren't demolished until 2012.

<span class="mw-page-title-main">Yarrow boiler</span> Obsolete class of high-pressure water-tube boilers widely used on ships

Yarrow boilers are an important class of high-pressure water-tube boilers. They were developed by Yarrow & Co. (London), Shipbuilders and Engineers and were widely used on ships, particularly warships.

Boilers for generating steam or hot water have been designed in countless shapes, sizes and configurations. An extensive terminology has evolved to describe their common features. This glossary provides definitions for these terms.

A Field-tube boiler is a form of water-tube boiler where the water tubes are single-ended. The tubes are closed at one end, and they contain a concentric inner tube. Flow is thus separated into the colder inner flow down the tube and the heated flow upwards through the outer sleeve. As Field tubes are thus dependent on thermo-syphon flow within the tube, they must thus always have some vertical height to encourage the flow. In most designs they are mounted near-vertically, to encourage this.

<span class="mw-page-title-main">Three-drum boiler</span> Compact furnace with two side water drums and one steam drum above

Three-drum boilers are a class of water-tube boiler used to generate steam, typically to power ships. They are compact and of high evaporative power, factors that encourage this use. Other boiler designs may be more efficient, although bulkier, and so the three-drum pattern was rare as a land-based stationary boiler.

<span class="mw-page-title-main">Spiral watertube boiler</span>

Spiral water-tube boilers are a family of vertical water-tube boilers. Their steam generating tubes are narrow spiral tubes, arranged in circular fashion around a central vertical water drum.

<span class="mw-page-title-main">Evaporator (marine)</span> Fresh water production device

An evaporator, distiller or distilling apparatus is a piece of ship's equipment used to produce fresh drinking water from sea water by distillation. As fresh water is bulky, may spoil in storage, and is an essential supply for any long voyage, the ability to produce more fresh water in mid-ocean is important for any ship.

<span class="mw-page-title-main">Steam generator (boiler)</span>

A steam generator is a form of low water-content boiler, similar to a flash steam boiler. The usual construction is as a spiral coil of water-tube, arranged as a single, or monotube, coil. Circulation is once-through and pumped under pressure, as a forced-circulation boiler. The narrow-tube construction, without any large-diameter drums or tanks, means that they are safe from the effects of explosion, even if worked at high pressures. The pump flowrate is adjustable, according to the quantity of steam required at that time. The burner output is throttled to maintain a constant working temperature. The burner output required varies according to the quantity of water being evaporated: this can be either adjusted by open-loop control according to the pump throughput, or by a closed-loop control to maintain the measured temperature.

<span class="mw-page-title-main">Forced circulation boiler</span>

A forced circulation boiler is a boiler where a pump is used to circulate water inside the boiler. This differs from a natural circulation boiler which relies on current density to circulate water inside the boiler. In some forced circulation boilers, the water is circulated at twenty times the rate of evaporation.

<span class="mw-page-title-main">Reed water tube boiler</span> Type of water tube boiler

The Reed water tube boiler was a type of water tube boiler developed by J. W. Reed, manager of the engine works at Palmers Shipbuilding and Iron Company of Jarrow, England, where it was manufactured from 1893 to 1905. At this time, Palmers was a vertically integrated business: in its shipyard at Jarrow, using iron ore from its own mine in North Yorkshire, it produced the iron and steel needed for its ships, and engines and boilers of its own design.

References

  1. Rajput, R.K. (2005). Comprehensive Basic Mechanical Engineering. Firewall Media. pp. 225–. ISBN   9788170084174 . Retrieved 18 April 2013.
  2. Spencer, J. F. (1859). Description of a New Construction of High Pressure Steam Boiler. Proceedings of the Institution of Mechanical Engineers, 1859, pp. 264-278.
  3. La Mont, Walter Douglas (1918). Steam generator. US Patent No. 1545668
  4. "Comdr. La Mont, Naval Engineer. Designer of Boiler now used with Success in many Navies dies in 53d Year". The New York Times. 20 January 1942. p. 19.
  5. Mayer, Fritz (1986). Kesselbetriebstechnik (in German). Germany: Technischer Verlag Resch KG. p. 101. ISBN   3-87806-033-5.