Superheater

Last updated

A superheater is a device used to convert saturated steam or wet steam into superheated steam or dry steam. Superheated steam is used in steam turbines for electricity generation, in some steam engines, and in processes such as steam reforming. There are three types of superheaters: radiant, convection, and separately fired. A superheater can vary in size from a few tens of feet to several hundred feet (a few metres to some hundred metres).

Contents

Types

Steam turbines

A simplified diagram of a coal-fired thermal power station. The superheater is the element 19. PowerStation2.svg
A simplified diagram of a coal-fired thermal power station. The superheater is the element 19.

In many applications, a turbine will make more efficient use of steam energy than a reciprocating engine. However, saturated ("wet") steam at boiling point may contain, or condense into, liquid water droplets, which can cause damage to turbine blades. Therefore, steam turbine engines typically superheat the steam, usually within the primary boiler, to ensure that no liquid water enters the system and damages the blades.

Steam engines

In a steam engine, the superheater further heats the steam generated by the boiler, increasing its thermal energy and decreasing the likelihood that it will condense inside the engine. [1] [2] Superheaters increase the thermal efficiency of the steam engine, and have been widely adopted. Steam which has been superheated is known as superheated steam, and non-superheated steam is called saturated steam or wet steam. From the early 20th century, superheaters were applied to many steam locomotives, to most steam vehicles, and to stationary steam engines. It is still used in conjunction with steam turbines in electrical power generating stations throughout the world.

Locomotives

General arrangement of a superheater installation in a steam locomotive. Superheater.jpg
General arrangement of a superheater installation in a steam locomotive.
Superheater viewed from the smokebox. Top centre is the superheater header, with pipes leading to cylinders. Tubes below feed steam into and out of the superheater elements within the flues. The stack and the damper have been removed for clarity. Superheater-front.jpg
Superheater viewed from the smokebox. Top centre is the superheater header, with pipes leading to cylinders. Tubes below feed steam into and out of the superheater elements within the flues. The stack and the damper have been removed for clarity.

In steam locomotive use, by far the most common form of superheater is the fire-tube type. That takes the saturated steam supplied in the dry pipe into a superheater header mounted against the tube sheet in the smokebox. The steam is then passed through a number of superheater elements, which are long pipes placed inside the larger diameter fire tubes, called flues. Hot combustion gases from the locomotive's fire pass through the flues and, as well as heating the water in the surrounding boiler, they heat the steam inside the superheater elements they flow over. The superheater element doubles back on itself so that the heated steam can return. Most do that twice at the fire end and once at the smokebox end, so that the steam travels a distance of four times the header's length while being heated. At the end of its journey through the elements, the superheated steam passes into a separate compartment of the superheater header and then to the cylinders of the engine.

Damper and snifting valve

The steam passing through the superheater elements cools their metal and prevents them from melting, but when the throttle closes that cooling effect is absent, and so a damper closes in the smokebox to cut off the flow through the flues and prevent them being damaged. Some locomotives, particularly on the London and North Eastern Railway, were fitted with snifting valves, which admitted air to the superheater when the locomotive was coasting. That kept the superheater elements relatively cooler and the cylinders warm. The snifting valve can be seen behind the chimney on many LNER locomotives.

Front-end throttle

A superheater increases the distance between the throttle and the cylinders in the steam circuit and thus reduces the immediacy of throttle action. To counteract that, some later steam locomotives were fitted with a front-end throttle, placed in the smokebox after the superheater. Such locomotives can sometimes be identified by an external throttle rod that stretches the whole length of the boiler, with a crank on the outside of the smokebox. That arrangement also allows superheated steam to be used for auxiliary appliances, such as the dynamo and air pumps. Another benefit of the front-end throttle is that superheated steam is immediately available. With a dome throttle, it takes some time before the super heater actually provides an efficiency benefit.

Cylinder valves

Locomotives with superheaters are usually fitted with piston valves or poppet valves, because it is difficult to keep a slide valve properly lubricated at high temperature.

Applications

Early color photograph from Russia taken by Sergey Prokudin-Gorsky in 1910 of steam locomotive with a superheater Prokudin-Gorskii-26.jpg
Early color photograph from Russia taken by Sergey Prokudin-Gorsky in 1910 of steam locomotive with a superheater

The first practical superheater was developed in Germany by Wilhelm Schmidt during the 1880s and 1890s. The Prussian S 4 locomotive, with an early form of superheater, was built in 1898, and more were produced in series from 1902. [3] The benefits of the invention were demonstrated in the UK by the Great Western Railway (GWR) in 1906. The GWR Chief Mechanical Engineer, G. J. Churchward, believed that the Schmidt type could be bettered, and the design and testing of an indigenous Swindon type was undertaken, culminating in the Swindon No. 3 superheater in 1909. [4] Douglas Earle Marsh carried out a series of comparative tests between members of his I3 class using saturated steam and those fitted with the Schmidt superheater between October 1907 and March 1910, proving the advantages of the latter in terms of performance and efficiency. [5]

Improved superheaters were introduced by John G. Robinson of the Great Central Railway at Gorton locomotive works, by Robert Urie of the London and South Western Railway (LSWR) at Eastleigh railway works, and Richard Maunsell of the Southern Railway (Great Britain), also at Eastleigh.

The oldest surviving steam locomotives with a superheater, as well as being the first narrow gauge locomotive with a superheater, is the Bh.1 owned by Steiermärkische Landesbahnen (STLB) in Austria, which runs excursions trains on the Mur Valley Railroad.[ citation needed ]

Urie's "Eastleigh" superheater

Robert Urie's design of superheater for the LSWR was the product of experience with his H15 class 4-6-0 locomotives. In anticipation of performance trials, eight examples were fitted with Schmidt and Robinson superheaters, and two others remained saturated. [6] However, World War I intervened before the trials could take place, although an LSWR Locomotive Committee report from late 1915 noted that the Robinson version returned the best fuel efficiency. It consumed an average of 48.35 lb (21.9 kg) coal per mile over an average distance of 39,824 mi (64,090.5 km), compared to 48.42 lb (22.0 kg) and 59.05 lb (26.8 kg) coal for the Schmidt and saturated examples respectively. [6]

However, the report stated that both superheater types had serious drawbacks. The Schmidt system featured a damper control on the superheater header that caused hot gases to condense into sulphuric acid, which caused pitting and subsequent weakening of the superheater elements. [6] Leakage of gases was also commonplace between the elements and the header, and maintenance was difficult without removal of the horizontally-arranged assembly. The Robinson version suffered from temperature variations caused by saturated and superheated steam chambers being adjacent, causing material stress, and had similar access problems as the Schmidt type. [6]

The report's recommendations enabled Urie to design a new type of superheater with separate saturated steam headers above and below the superheater header. [7] They were connected by elements beginning at the saturated header, running through the flue tubes and back to the superheater header, and the whole assembly was vertically arranged for ease of maintenance. [7] The device was highly successful in service, but was heavy and expensive to construct. [7]

Advantages and disadvantages

The main advantages of using a superheater are reduced fuel and water consumption but there is a price to pay in increased maintenance costs. In most cases the benefits outweighed the costs and superheaters became widely used, although British shunting locomotives (switchers) were rarely fitted with superheaters. In locomotives used for mineral traffic the advantages seem to have been marginal. For example, the North Eastern Railway fitted superheaters to some of its NER Class P mineral locomotives but later began to remove them.

Without careful maintenance, superheaters are prone to a particular type of hazardous failure, involving the superheater tubes bursting at their U-shaped turns. They are difficult to manufacture, and to test when installed, and a rupture causes the superheated high-pressure steam to escape into the large flues, back to the fire and into the locomotive cab, creating extreme danger for the locomotive crew.

Related Research Articles

<span class="mw-page-title-main">Boiler</span> Closed vessel in which fluid is heated

A boiler is a closed vessel in which fluid is heated. The fluid does not necessarily boil. The heated or vaporized fluid exits the boiler for use in various processes or heating applications, including water heating, central heating, boiler-based power generation, cooking, and sanitation.

<span class="mw-page-title-main">Steam locomotive components</span> Glossary of the main components of a typical steam locomotive

Main components found on a typical steam locomotive include:

<span class="mw-page-title-main">Fire-tube boiler</span> Type of boiler

A fire-tube boiler is a type of boiler invented in 1828 by Mark Seguin, in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.

<span class="mw-page-title-main">Water-tube boiler</span> Type of furnace generating steam

A high pressure watertube boiler is a type of boiler in which water circulates in tubes heated externally by fire. Fuel is burned inside the furnace, creating hot gas which boils water in the steam-generating tubes. In smaller boilers, additional generating tubes are separate in the furnace, while larger utility boilers rely on the water-filled tubes that make up the walls of the furnace to generate steam.

<span class="mw-page-title-main">LSWR H15 class</span>

The LSWR/SR H15 class was a class of 2-cylinder 4-6-0 steam locomotives designed by Robert Urie for mixed-traffic duties on the LSWR. Further batches were constructed by Richard Maunsell for the Southern Railway after 1923. They were given the nickname of "Junior King Arthur" due to the size of their driving wheels, the S15 and their N15 cousins had driving wheels which had a diameter of 5 foot and 7 inches and 6 foot and 7 inches respectively.

<span class="mw-page-title-main">LSWR N15 class</span> Class of 74 two-cylinder 4-6-0 locomotives

The LSWR N15 class was a British 2–cylinder 4-6-0 express passenger steam locomotive designed by Robert Urie. The class has a complex build history spanning three sub-classes and eight years of construction from 1918 to 1927. The first batch of the class was constructed for the London and South Western Railway (LSWR), where they hauled heavy express passenger trains to the south coast ports and further west to Exeter. After the Lord Nelsons, they were the second biggest 4-6-0 passenger locomotives on the Southern Railway. They could reach speeds of up to 90 mph (145 km/h).

<span class="mw-page-title-main">Smokebox</span>

A smokebox is one of the major basic parts of a steam locomotive exhaust system. Smoke and hot gases pass from the firebox through tubes where they pass heat to the surrounding water in the boiler. The smoke then enters the smokebox, and is exhausted to the atmosphere through the chimney. Early locomotives had no smokebox and relied on a long chimney to provide natural draught for the fire but smokeboxes were soon included in the design for two specific reasons. Firstly and most importantly, the blast of exhaust steam from the cylinders, when directed upwards through an airtight smokebox with an appropriate design of exhaust nozzle, effectively draws hot gases through the boiler tubes and flues and, consequently, fresh combustion air into the firebox. Secondly, the smokebox provides a convenient collection point for ash and cinders ("char") drawn through the boiler tubes, which can be easily cleaned out at the end of a working day. Without a smokebox, all char must pass up the chimney or it will collect in the tubes and flues themselves, gradually blocking them.

<span class="mw-page-title-main">LSWR L12 class</span>

The London and South Western Railway L12 class was a class of 20 4-4-0 steam locomotives designed for express passenger work by Dugald Drummond. They were introduced to the London and South Western Railway network in 1904. Despite the class being an unremarkable continuation of the Drummond lineage, one member was involved in the infamous Salisbury rail crash in June 1906. None of the class survived into preservation after their brief career in British Railways ownership.

<span class="mw-page-title-main">LSWR T14 class</span>

The LSWR Class T14 was a class of ten 4-6-0 locomotives designed by Dugald Drummond for express passenger use on the London and South Western Railway and constructed at Eastleigh in 1911–12.

<span class="mw-page-title-main">Boiler (power generation)</span> High pressure steam generator

A boiler or steam generator is a device used to create steam by applying heat energy to water. Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure but, at pressures above this, it is more usual to speak of a steam generator.

<span class="mw-page-title-main">LSWR D15 class</span>

The LSWR D15 class 4-4-0 was the last steam locomotive design by Dugald Drummond for the London and South Western Railway in 1912. By 1912, Dugald Drummond had built several classes of unsuccessful 4-6-0 express passenger locomotives. The result of these failures was that when he designed what was to be his last class in 1911, a new 4-4-0 design emerged from Eastleigh Works in February 1912, with what was to be the first of his D15 class.

<span class="mw-page-title-main">Snifting valve</span> Anti-vacuum valve in steam locomotives

A snifting valve is an automatic anti-vacuum valve used in a steam locomotive when coasting. The word Snift imitates the sound made by the valve.

The London, Midland and Scottish Railway (LMS) 2 and 2A boilered 4-6-0 locomotives were express passenger 4-6-0 steam locomotives. In 1935, William Stanier, Chief Mechanical Engineer of the LMS, ordered the rebuilding of the unique experimental high pressure compound locomotive 6399 Fury. The Schmidt-Henschel boiler was replaced with a tapered boiler, with a drumhead smokebox, designated type 2. The type 2 boiler had a tube surface of 1,669 square feet, formed by tubes 2+18 inches (54 mm) in diameter and 14 ft 3 in (4.34 m) long. It was fitted with a 28-row superheater with 360 square feet (33 m2) of heating surface. The superheater elements, 1+18 inches (29 mm) in diameter, were fitted into flue tubes 5+18 inches (130 mm) diameter.

<span class="mw-page-title-main">Yarrow boiler</span> Obsolete class of water-tube boilers widely used on ships

Yarrow boilers are an important class of high-pressure water-tube boilers. They were developed by Yarrow & Co. (London), Shipbuilders and Engineers and were widely used on ships, particularly warships.

Boilers for generating steam or hot water have been designed in countless shapes, sizes and configurations. An extensive terminology has evolved to describe their common features. This glossary provides definitions for these terms.

<span class="mw-page-title-main">South African Class 10D 4-6-2</span>

The South African Railways Class 10D 4-6-2 of 1910 was a steam locomotive from the pre-Union era in Transvaal.

<span class="mw-page-title-main">South African Class 10B 4-6-2</span>

The South African Railways Class 10B 4-6-2 of 1910 was a steam locomotive from the pre-Union era in Transvaal.

<span class="mw-page-title-main">South African Class 10A 4-6-2</span> South African steam locomotive

The South African Railways Class 10A 4-6-2 of 1910 was a steam locomotive from the pre-Union era in Transvaal.

<span class="mw-page-title-main">South African Class 6L 4-6-0</span>

The South African Railways Class 6L 4-6-0 of 1904 was a steam locomotive from the pre-Union era in the Cape of Good Hope.

The South African Railways Class 3A 4-8-2 of 1910 was a steam locomotive from the pre-Union era in the Colony of Natal.

References

  1. "Superheater". www.pleasley-colliery.org.uk.
  2. "How a steam railway engine works". Archived from the original on 2008-12-21. Retrieved 2008-12-28.
  3. Herbert Rauter, Günther Scheingraber, 1991: Preußen-Report. Band 2: Die Schnellzuglokomotiven der Gattung S 1 – S 11. Hermann Merker Verlag , ISBN   3-922404-16-2 (in German), pp. 85-88.
  4. Allcock, N.J.; Davies, F.K.; le Fleming, H.M.; Maskelyne, J.N.; Reed, P.J.T.; Tabor, F.J. (June 1951). White, D.E. (ed.). The Locomotives of the Great Western Railway, part one: Preliminary Survey. Kenilworth: RCTS. p. 56. ISBN   0-901115-17-7. OCLC   650412984.
  5. Bradley (1974)
  6. 1 2 3 4 Bradley (1987), p. 15
  7. 1 2 3 Bradley (1987), p. 16

Bibliography