In computer networking, Gigabit Ethernet (GbE or 1 GigE) is the term applied to transmitting Ethernet frames at a rate of a gigabit per second. The most popular variant, 1000BASE-T, is defined by the IEEE 802.3ab standard. It came into use in 1999, and has replaced Fast Ethernet in wired local networks due to its considerable speed improvement over Fast Ethernet, as well as its use of cables and equipment that are widely available, economical, and similar to previous standards. The first standard for faster 10 Gigabit Ethernet was approved in 2002. [1]
Ethernet was the result of research conducted at Xerox PARC in the early 1970s, and later evolved into a widely implemented physical and link layer protocol. Fast Ethernet increased the speed from 10 to 100 megabits per second (Mbit/s). Gigabit Ethernet was the next iteration, increasing the speed to 1000 Mbit/s.
Initially, Gigabit Ethernet was deployed in high-capacity backbone network links (for instance, on a high-capacity campus network). In 2000 and 2001, Apple's Power Mac G4 and PowerBook G4 respectively were the first mass-produced personal computers to feature the 1000BASE-T connection. [2] It quickly became a built-in feature in many other computers.
Half-duplex GbE links connected through repeater hubs were part of the IEEE specification, [3] but the specification is not updated anymore and full-duplex operation with switches is used exclusively.
There are five physical layer standards for Gigabit Ethernet using optical fiber (1000BASE-X), twisted pair cable (1000BASE-T), or shielded balanced copper cable (1000BASE-CX).
The IEEE 802.3z standard includes 1000BASE-SX for transmission over multi-mode fiber, 1000BASE-LX for transmission over single-mode fiber, and the nearly obsolete 1000BASE-CX for transmission over shielded balanced copper cabling. These standards use 8b/10b encoding, which inflates the line rate by 25%, from 1000 Mbit/s to 1250 Mbit/s, to ensure a DC balanced signal, and allow for clock recovery. The symbols are then sent using NRZ.
Optical fiber transceivers are most often implemented as user-swappable modules in SFP form or GBIC on older devices.
IEEE 802.3ab, which defines the widely used 1000BASE-T interface type, uses a different encoding scheme in order to keep the symbol rate as low as possible, allowing transmission over twisted pair.
IEEE 802.3ap defines Ethernet Operation over Electrical Backplanes at different speeds.
Ethernet in the First Mile later added 1000BASE-LX10 and -BX10.
Name | Standard | Status | Speed (Mbit/s) | Pairs required | Lanes per direction | Bits per hertz | Line code | Symbol rate per lane (MBd) | Bandwidth (MHz) | Max distance (m) | Cable (minimum required) | Cable rating (MHz) | Usage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1000BASE‑T | 802.3ab-1999 (CL40) | current | 1000 | 4 | 4 | 4 | TCM 4D-PAM-5 | 125 | 62.5 | 100 | Cat 5 | 100 | LAN |
1000BASE-T1 | 802.3bp-2016 | current | 1000 | 1 | 1 | 2.66 | PAM-3 80B/81B RS-FEC | 750 | 375 | 40 | Cat 6A | 500 | Automotive, IoT, M2M |
1000BASE‑TX | TIA/EIA-854 (2001) | obsolete | 1000 | 4 | 2 | 4 | PAM-5 | 250 | 125 | 100 | Cat 6 | 250 | Market failure |
1000BASE-T (also known as IEEE 802.3ab) is a standard for Gigabit Ethernet over twisted-pair wiring.
Each 1000BASE-T network segment is recommended to be a maximum length of 100 meters (330 feet), [5] [lower-alpha 1] and must use Category 5 cable or better (including Cat 5e and Cat 6).
Autonegotiation is a requirement for using 1000BASE-T [6] according to Section 28D.5 Extensions required for Clause40 (1000BASE-T). [7] At least the clock source has to be negotiated, as one endpoint must be master and the other endpoint must be slave.
In a departure from both 10BASE-T and 100BASE-TX, 1000BASE-T uses four lanes over all four cable pairs for simultaneous transmission in both directions through the use of echo cancellation with adaptive equalization called hybrid circuits [8] (this is like telephone hybrid) and five-level pulse-amplitude modulation (PAM-5). The symbol rate is identical to that of 100BASE-TX (125 megabaud (MBd)) and the noise immunity of the five-level signaling is also identical to that of the three-level signaling in 100BASE-TX, since 1000BASE-T uses four-dimensional trellis coded modulation (TCM) to achieve a 6 dB coding gain across the four pairs.
Since negotiation takes place on only two pairs, if two GbE interfaces are connected through a cable with only two pairs, the interfaces will successfully choose 'gigabit' as the highest common denominator (HCD),[ clarification needed ] but the link will never come up. Most GbE physical devices have a specific register to diagnose this behavior. Some drivers offer an "Ethernet@Wirespeed" option where this situation leads to a slower yet functional connection. [9]
The data is transmitted over four copper pairs, eight bits at a time. First, eight bits of data are expanded into four three-bit symbols through a non-trivial scrambling procedure based on a linear-feedback shift register; this is similar to what is done in 100BASE-T2, but uses different parameters. The three-bit symbols are then mapped to voltage levels which vary continuously during transmission. An example mapping is as follows:
Symbol | 000 | 001 | 010 | 011 | 100 | 101 | 110 | 111 |
---|---|---|---|---|---|---|---|---|
Line signal level | 0 | +1 | +2 | −1 | 0 | +1 | −2 | −1 |
Automatic MDI/MDI-X Configuration is specified as an optional feature in the 1000BASE-T standard, [10] meaning that straight-through cables will often work between two GbE-capable network node interfaces (both MDI) and between two switch or hub interfaces (both MDI-X). This feature eliminates the need for crossover cables, making obsolete the uplink vs normal port choices and manual selector switches found on many older hubs and switches and greatly reduces installation errors.
In order to extend and maximize the use of existing Cat-5e and Cat-6 cabling, the newer standards 2.5GBASE-T and 5GBASE-T operate at 2.5 and 5.0 Gbit/s, respectively, on existing copper infrastructure designed for use with 1000BASE-T. They are based on 10GBASE-T but use lower signaling frequencies.
IEEE 802.3 standardized 1000BASE-T1 in IEEE Std 802.3bp-2016. [11] It defines Gigabit Ethernet over a single twisted pair for automotive and industrial applications. It includes cable specifications for 15 meters (type A) or 40 meters (type B) reach. The transmission is done using PAM-3 at 750 MBd.
The Telecommunications Industry Association (TIA) created and promoted a standard similar to 1000BASE-T that was simpler to implement, calling it 1000BASE-TX (TIA/EIA-854). [12] The simplified design would have, in theory, reduced the cost of the required electronics by only using four unidirectional pairs (two pairs TX and two pairs RX) instead of four bidirectional pairs. However, this solution has been a commercial failure,[ citation needed ] likely due to the required Category 6 cabling and the rapidly falling cost of 1000BASE-T products.
802.3z-1998 CL39 standardized 1000BASE-CX is an initial standard for Gigabit Ethernet connections with maximum distances of 25 meters using balanced shielded twisted pair and either DE-9 or 8P8C connector (with a pinout different from 1000BASE-T). The short segment length is due to a very high signal transmission rate. Although it is still used for specific applications where cabling is done by IT professionals, for instance, the IBM BladeCenter uses 1000BASE-CX for the Ethernet connections between the blade servers and the switch modules, 1000BASE-T has succeeded it for general copper wiring use. [13]
802.3ap-2007 CL70 standardized 1000BASE-KX is part of the IEEE 802.3ap standard for Ethernet Operation over Electrical Backplanes. This standard defines one to four lanes of backplane links, one RX and one TX differential pair per lane, at link bandwidth ranging from 100 Mbit to 10 Gbit per second (from 100BASE-KX to 10GBASE-KX4). The 1000BASE-KX variant uses 1.25 GBd electrical (not optical) signalling speed.
1000BASE-X is used in industry to refer to Gigabit Ethernet transmission over fiber, where options include 1000BASE-SX, 1000BASE-LX, 1000BASE-LX10, 1000BASE-BX10 or the non-standard -EX and -ZX implementations. Included are copper variants using the same 8b/10b line code. 1000BASE-X is based on the physical-layer standards developed for Fibre Channel. [14]
Fibre type | Introduced | Performance |
---|---|---|
MMF FDDI 62.5/125 µm | 1987 | MHz·km @ 850 nm | 160
MMF OM1 62.5/125 µm | 1989 | MHz·km @ 850 nm | 200
MMF OM2 50/125 µm | 1998 | MHz·km @ 850 nm | 500
MMF OM3 50/125 µm | 2003 | 1500 MHz·km @ 850 nm |
MMF OM4 50/125 µm | 2008 | 3500 MHz·km @ 850 nm |
MMF OM5 50/125 µm | 2016 | 3500 MHz·km @ 850 nm + 1850 MHz·km @ 950 nm |
SMF OS1 9/125 µm | 1998 | 1.0 dB/km @ 1300/1550 nm |
SMF OS2 9/125 µm | 2000 | 0.4 dB/km @ 1300/1550 nm |
Name | Standard | Status | Media | Connector | Transceiver Module | Reach in m | # Media (⇆) | # Lambdas (→) | # Lanes (→) | Notes |
---|---|---|---|---|---|---|---|---|---|---|
Gigabit Ethernet (GbE) - (Data rate: 1000 Mbit/s - Line code: 8B/10B × NRZ - Line rate: 1.25 GBd - Full-Duplex (or Half-Duplex)) | ||||||||||
1000BASE‑CX | 802.3z-1998 (CL39) | legacy | TWP shielded balanced (150 Ω) | 8P8C DE-9 FC/HSSDC CX4 (SFF-8470) (IEC 61076-3-103) | — | 25 | 4 | N/A | 4 | Data centres; predates 1000BASE-T; rarely used. |
1000BASE‑KX | 802.3ap-2007 (CL70) | current | Cu-Backplane | — | — | 1 | 1 | N/A | 4 | PCBs |
1000BASE‑SX | 802.3z-1998 (CL38) | current | Fibre 770 – 860 nm | ST SC LC MT-RJ [15] | SFP direct-plug | OM1: 275 | 2 | 1 | 1 | |
OM2: 550 | ||||||||||
OM3: 1k [16] | ||||||||||
1000BASE‑LSX | proprietary (non IEEE) | current | Fibre 1310 nm | LC | SFP | OM1: 2k [17] | 2 | 1 | 1 | vendor-specific; FP laser transmitter |
OM2: 1k [18] | ||||||||||
OM4: 2k [19] | ||||||||||
1000BASE‑LX | 802.3z-1998 (CL38) | current | Fibre 1270 – 1355 nm | SC LC | SFP GBIC direct-plug | OM1: 550 | 2 | 1 | 1 | |
OM2: 550 | ||||||||||
OM3: 550 | ||||||||||
OSx: 5k | ||||||||||
1000BASE‑LX10 | 802.3ah-2004 (CL59) | current | Fibre 1260 – 1360 nm | LC | SFP | OM1: 550 | 2 | 1 | 1 | identical with -LX but with increased power/sensitivity; commonly simply referred to as -LX or -LH prior to 802.3ah |
OM2: 550 | ||||||||||
OM3: 550 | ||||||||||
OSx: 10k | ||||||||||
1000BASE-BX10 | current | Fibre TX: 1260 – 1360 nm RX: 1480 – 1500 nm | OSx: 10k | 1 | often simply referred to as -BX | |||||
1000BASE‑EX | proprietary (non IEEE) | current | Fibre 1310 nm | SC LC | SFP GBIC | OSx: 40k | 2 | 1 | 1 | vendor-specific |
1000BASE‑ZX / ‑EZX | proprietary (non IEEE) | current | Fibre 1550 nm | SC LC | SFP GBIC | OSx: 70k | 2 | 1 | 1 | vendor-specific |
1000BASE‑RHx | 802.3bv-2017 (CL115) | current | Fibre 650 nm | FOT (PMD/MDI) | — | POF: ≤ 50 | 1 | 1 | 1 | Automotive, Industry, Home; [20] [21] Line code: 64b65b × PAM16 Line rate: 325 MBd Variants: -RHA (50 m), -RHB (40 m), -RHC (15 m). |
1000BASE-PX | 802.3ah-2004 802.3bk-2013 (CL60) | current | Fibre TX: 1270 nm RX: 1577 nm | SC | SFP XFP | OSx: 10k – 40k | 1 | 1 | 1 | EPON; FTTH; using point-to-multipoint topology. |
1000BASE‑CWDM [22] [23] | ITU-T G.694.2 | current | Fibre 1270 – 1610 nm | LC | SFP | OSx: 40k – 100k | 2 | 1 | 1 | CWDM makes it possible to have multiple parallel channels over 2 fibers; spectral bandwidth 11 nm; capable of 18 parallel channels |
1000BASE‑DWDM [24] [23] | ITU-T G.694.1 | current | Fibre 1528 – 1565 nm | LC | SFP | OSx: 40k – 120k | 2 | 1 | 1 | DWDM makes it possible to have multiple parallel channels over 2 fibers; spectral bandwidth 0.2 nm; capable of 45 to 160 parallel channels |
1000BASE-SX is an optical fiber Gigabit Ethernet standard for operation over multi-mode fiber using a 770 to 860 nanometer, near infrared (NIR) light wavelength.
The standard specifies a maximum length of 220 meters for 62.5 μm/160 MHz×km multi-mode fiber, 275 m for 62.5 μm/200 MHz×km, 500 m for 50 μm/400 MHz×km, and 550 m for 50 μm/500 MHz×km multi-mode fiber. [25] [26] Fiber optic cable manufacturers have extended the reach of 1000BASE-SX to at least 1km when used with more modern fiber optic grades such as OM3 and OM4. [16]
This standard is highly popular for intra-building links in large office buildings, co-location facilities and carrier-neutral Internet exchanges.
Optical power specifications of SX interface: Minimum output power = −9.5 dBm. Minimum receive sensitivity = −17 dBm.
1000BASE-LSX is a non-standard but industry accepted [27] term to refer to Gigabit Ethernet transmission. It is very similar to 1000BASE-SX but achieves longer distances up to 2 km over a pair of multi-mode fibers due to higher quality optics than a SX, running on 1310 nm wavelength lasers. It is easily confused with 1000BASE-SX or 1000BASE-LX because the use of -LX, -LX10 and -SX is ambiguous between vendors. The range is achieved with use of Fabry Perot laser transmitter.
1000BASE-LX is an optical fiber Gigabit Ethernet standard specified in IEEE 802.3 Clause 38 which uses a long wavelength laser (1,270–1,355 nm), and a maximum RMS spectral width of 4 nm.
1000BASE-LX is specified to work over a distance of up to 5 km over 10 μm single-mode fiber.
1000BASE-LX can also run over all common types of multi-mode fiber with a maximum segment length of 550 m. For link distances greater than 300 m, the use of a special launch conditioning patch cord may be required. [28] This launches the laser at a precise offset from the center of the fiber which causes it to spread across the diameter of the fiber core, reducing the effect known as differential mode delay which occurs when the laser couples onto only a small number of available modes in multi-mode fiber.
1000BASE-LX10 was standardized six years after the initial gigabit fiber versions as part of the Ethernet in the First Mile task group. It is practically identical to 1000BASE-LX, but achieves longer distances up to 10 km over a pair of single-mode fiber due to higher quality optics. Before it was standardized, 1000BASE-LX10 was essentially already in widespread use by many vendors as a proprietary extension called either 1000BASE-LX/LH or 1000BASE-LH. [29]
1000BASE-EX is a non-standard but industry accepted term [30] to refer to Gigabit Ethernet transmission. It is very similar to 1000BASE-LX10 but achieves longer distances up to 40 km over a pair of single-mode fibers due to higher quality optics than a LX10, running on 1310 nm wavelength lasers. It is sometimes referred to as LH (Long Haul), and is easily confused with 1000BASE-LX10 or 1000BASE-ZX because the use of -LX(10), -LH, -EX, and -ZX is ambiguous between vendors. 1000BASE-ZX is a very similar non-standard longer-reach variant that uses 1550 nm wavelength optics.
1000BASE-BX10 is capable of up to 10 km over a single strand of single-mode fiber, with a different wavelength going in each direction. The terminals on each side of the fiber are not equal, as the one transmitting downstream (from the center of the network to the outside) uses the 1490 nm wavelength, and the one transmitting upstream uses the 1310 nm wavelength. This is accomplished using a passive splitter prism inside each transceiver.
Other, non-standard higher-powered single-strand optics commonly known as "BiDi" (bi-directional) utilize wavelength pairs in the 1490/1550 nm range, and are capable of reaching distances of 20, 40 and 80 km, or greater depending on module cost, fiber path loss, splices, connectors and patch panels. Very long reach BiDi optics may use 1510/1590 nm wavelength pairs.
1000BASE-ZX is a non-standard but multi-vendor [31] term to refer to Gigabit Ethernet transmission using 1,550 nm wavelength to achieve distances of at least 70 km (43 mi) over single-mode fiber. Some vendors specify distances up to 120 km (75 mi) over single-mode fiber, sometimes called 1000BASE-EZX. Ranges beyond 80 km are highly dependent upon the path loss of the fiber in use, specifically the attenuation figure in dB per km, the number and quality of connectors/patch panels and splices located between transceivers. [32]
1000BASE-CWDM is a non-standard but industry accepted term [22] [23] to refer to Gigabit Ethernet transmission. It is very similar to 1000BASE-LX10 but achieves longer distances up 40–120 km, and up to 18 parallel channels over a pair of single-mode fibers due to higher quality optics than LX10 and use of CWDM, running on 1270-1610 nm wavelength lasers.
Use of CWDM requires a Mux/Demux unit at both ends of the fiber link, a CWDM MUX/DEMUX with corresponding wavelengths, and SFP with corresponding wavelengths. [23] is it also possible to DWDM in serie to increase number of channels.
Most uses Wavelengths: 1270 nm, 1290 nm, 1310 nm, 1330 nm, 1350 nm, 1370 nm, 1390 nm, 1410 nm, 1430 nm, 1450 nm, 1470 nm, 1490 nm, 1510 nm, 1530 nm, 1550 nm, 1570 nm, 1590 nm and 1610 nm
CWDM is cheaper to use than DWDM, about 1/5-1/3 of the cost. [33] [34] CWDM is about 5-10 times more expensive the if you have the fiber available, then traditional -LX/-LZ transceivers.
1000BASE-DWDM is a non-standard but industry accepted term [24] [23] to refer to Gigabit Ethernet transmission. It is very similar to 1000BASE-LX10 but achieves longer distances up 40–120 km, and up to 64 to 160 parallel channels over a pair of single-mode fibers due to higher quality optics than LX10 and use of DWDM, running on 1528-1565 nm wavelength lasers.
The most used channels are CH17-61 on Wavelength 1528.77-1563-86 nm.
To use DWDM it is necessary to use a Mux/Demux unit on both ends of the fiber link, a DWDM MUX/DEMUX with corresponding wavelengths, and SFP with corresponding wavelengths. [23] is it also possible to use CWDM in series to increase the number of channels.[ citation needed ]
IEEE 802.3bv-2017 defines standardizes Gigabit Ethernet over step-index plastic optical fiber (POF) using -R 64b/65b large block encoding with red light (600–700 nm). 1000BASE-RHA is intended for home and consumer use (just clamping the bare POF), 1000BASE-RHB for industrial, and 1000BASE-RHC for automotive applications.
There may be optical interoperability with respective 1000BASE-X Ethernet interfaces on the same link. [35] It is also possible with certain types of optics to have a mismatch in wavelength. [36]
To achieve interoperability some criteria have to be met: [37]
1000BASE-X Ethernet is not backward compatible with 100BASE-X and is not forward compatible with 10GBASE-X.
Ethernet over twisted-pair technologies use twisted-pair cables for the physical layer of an Ethernet computer network. They are a subset of all Ethernet physical layers.
In computer networking, Fast Ethernet physical layers carry traffic at the nominal rate of 100 Mbit/s. The prior Ethernet speed was 10 Mbit/s. Of the Fast Ethernet physical layers, 100BASE-TX is by far the most common.
In the seven-layer OSI model of computer networking, the physical layer or layer 1 is the first and lowest layer: the layer most closely associated with the physical connection between devices. The physical layer provides an electrical, mechanical, and procedural interface to the transmission medium. The shapes and properties of the electrical connectors, the frequencies to transmit on, the line code to use and similar low-level parameters, are specified by the physical layer.
In fiber-optic communications, wavelength-division multiplexing (WDM) is a technology which multiplexes a number of optical carrier signals onto a single optical fiber by using different wavelengths of laser light. This technique enables bidirectional communications over a single strand of fiber as well as multiplication of capacity.
Small Form-factor Pluggable (SFP) is a compact, hot-pluggable network interface module format used for both telecommunication and data communications applications. An SFP interface on networking hardware is a modular slot for a media-specific transceiver, such as for a fiber-optic cable or a copper cable. The advantage of using SFPs compared to fixed interfaces is that individual ports can be equipped with different types of transceivers as required, with the majority including optical line terminals, network cards, switches and routers.
A passive optical network (PON) is a fiber-optic telecommunications network that uses only unpowered devices to carry signals, as opposed to electronic equipment. In practice, PONs are typically used for the last mile between Internet service providers (ISP) and their customers. In this use, a PON has a point-to-multipoint topology in which an ISP uses a single device to serve many end-user sites using a system such as 10G-PON or GPON. In this one-to-many topology, a single fiber serving many sites branches into multiple fibers through a passive splitter, and those fibers can each serve multiple sites through further splitters. The light from the ISP is divided through the splitters to reach all the customer sites, and light from the customer sites is combined into the single fiber. Many fiber ISPs prefer this system.
Autonegotiation is a signaling mechanism and procedure used by Ethernet over twisted pair by which two connected devices choose common transmission parameters, such as speed, duplex mode, and flow control. In this process, the connected devices first share their capabilities regarding these parameters and then choose the highest-performance transmission mode they both support.
A medium-dependent interface (MDI) describes the interface in a computer network from a physical-layer implementation to the physical medium used to carry the transmission. Ethernet over twisted pair also defines a medium-dependent interface – crossover (MDI-X) interface. Auto–MDI-X ports on newer network interfaces detect if the connection would require a crossover and automatically choose the MDI or MDI-X configuration to complement the other end of the link.
Multi-mode optical fiber is a type of optical fiber mostly used for communication over short distances, such as within a building or on a campus. Multi-mode links can be used for data rates up to 800 Gbit/s. Multi-mode fiber has a fairly large core diameter that enables multiple light modes to be propagated and limits the maximum length of a transmission link because of modal dispersion. The standard G.651.1 defines the most widely used forms of multi-mode optical fiber.
Physical medium dependent sublayers or PMDs further help to define the physical layer of computer network protocols. They define the details of transmission and reception of individual bits on a physical medium. These responsibilities encompass bit timing, signal encoding, interacting with the physical medium, and the properties of the cable, optical fiber, or wire itself. Common examples are specifications for Fast Ethernet, Gigabit Ethernet and 10 Gigabit Ethernet defined by the Institute of Electrical and Electronics Engineers (IEEE).
The physical coding sublayer (PCS) is a networking protocol sublayer in the Fast Ethernet, Gigabit Ethernet, and 10 Gigabit Ethernet standards. It resides at the top of the physical layer (PHY), and provides an interface between the physical medium attachment (PMA) sublayer and the media-independent interface (MII). It is responsible for data encoding and decoding, scrambling and descrambling, alignment marker insertion and removal, block and symbol redistribution, and lane block synchronization and deskew.
An Ethernet crossover cable is a crossover cable for Ethernet used to connect computing devices together directly. It is most often used to connect two devices of the same type, e.g. two computers or two switches to each other. By contrast, straight through patch cables are used to connect devices of different types, such as a computer to a network switch.
The physical-layer specifications of the Ethernet family of computer network standards are published by the Institute of Electrical and Electronics Engineers (IEEE), which defines the electrical or optical properties and the transfer speed of the physical connection between a device and the network or between network devices. It is complemented by the MAC layer and the logical link layer. An implementation of a specific physical layer is commonly referred to as PHY.
Ethernet in the first mile (EFM) refers to using one of the Ethernet family of computer network technologies between a telecommunications company and a customer's premises. From the customer's point of view, it is their first mile, although from the access network's point of view it is known as the last mile.
40 Gigabit Ethernet (40GbE) and 100 Gigabit Ethernet (100GbE) are groups of computer networking technologies for transmitting Ethernet frames at rates of 40 and 100 gigabits per second (Gbit/s), respectively. These technologies offer significantly higher speeds than 10 Gigabit Ethernet. The technology was first defined by the IEEE 802.3ba-2010 standard and later by the 802.3bg-2011, 802.3bj-2014, 802.3bm-2015, and 802.3cd-2018 standards. The first succeeding Terabit Ethernet specifications were approved in 2017.
10 Gigabit Ethernet is a group of computer networking technologies for transmitting Ethernet frames at a rate of 10 gigabits per second. It was first defined by the IEEE 802.3ae-2002 standard. Unlike previous Ethernet standards, 10GbE defines only full-duplex point-to-point links which are generally connected by network switches; shared-medium CSMA/CD operation has not been carried over from the previous generations of Ethernet standards so half-duplex operation and repeater hubs do not exist in 10GbE. The first standard for faster 100 Gigabit Ethernet links was approved in 2010.
Terabit Ethernet (TbE) is Ethernet with speeds above 100 Gigabit Ethernet. The 400 Gigabit Ethernet and 200 Gigabit Ethernet standard developed by the IEEE P802.3bs Task Force using broadly similar technology to 100 Gigabit Ethernet was approved on December 6, 2017. On February 16, 2024 the 800 Gigabit Ethernet standard developed by the IEEE P802.3df Task Force was approved.
The OPEN Alliance is a non-profit, special interest group (SIG) of mainly automotive industry and technology providers collaborating to encourage wide scale adoption of Ethernet-based communication as the standard in automotive networking applications.
25 Gigabit Ethernet and 50 Gigabit Ethernet are standards for Ethernet connectivity in a datacenter environment, developed by IEEE 802.3 task forces 802.3by and 802.3cd and are available from multiple vendors.
IEEE 802.3bz, NBASE-T and MGBASE-T are standards released in 2016 for Ethernet over twisted pair at speeds of 2.5 and 5 Gbit/s. These use the same cabling as the ubiquitous Gigabit Ethernet, yet offer higher speeds. The resulting standards are named 2.5GBASE-T and 5GBASE-T.