Underground mine ventilation

Last updated
Schematic of underground mine ventilation Ventilacion aspirante.svg
Schematic of underground mine ventilation
The mine ventilation fan, before 1908 Mine ventilation fan.jpg
The mine ventilation fan, before 1908

Underground mine ventilation provides a flow of air to the underground workers of a mine with sufficient volume to dilute and remove dust and noxious gases (typically NOx, SO2, methane, CO2 and CO) and to regulate temperature. The source of these gases are equipment that runs on diesel engines, blasting with explosives, [1] and the orebody itself. [2] Regulations often require airflow to be distributed within mines to improve air quality. [3] [ citation needed ]

Contents

The largest component of the operating cost for mine ventilation is electricity to power the ventilation fans, which may account for one third of a typical underground mine's entire electrical power cost. [1]

Types of ventilation

Flow-through ventilation is the main ventilation circuit for the mine. Air enters the mine from the surface via a shaft, ventilation raise or adit. The air is distributed through the mine via internal ventilation raises and ramps, and flows are controlled by regulators and permanently mounted ventilation fans. An auxiliary ventilation system takes air from the flow-through system and distributes it to the mine workings via temporarily mounted ventilation fans, Venturi tubes and disposable fabric or steel ducting. Auxiliary fan and duct systems may be either forcing systems, where fresh air is pushed into mine headings, or exhausting systems that draw out contaminated air. [4]

Ventilation control

Sufficient volume of air is required for proper ventilation. A bulk of electric power is required for driving fans. By installing variable speed control air quantity can be optimized hence the power. [5] At every place in the mine where persons are required to work or pass, the air should not contain less than 19% of oxygen or more than 0.5% of carbon dioxide or any noxious gas in quantity likely to affect the health of any person. The percentage of inflammable gas does not exceed 0.75% in the general body of the return air of any ventilating district and 1.25% in any place in the mine.

Regulations

The volume (expressed in cubic feet per minute or cubic meters per second) of air required to ventilate an underground mine is determined by mining engineers based on a wide variety of parameters. In most countries minimum requirements are outlined by law, regulation or standards. However, in some developing countries the mandated ventilation requirement may be insufficient, and the mining company may have to increase the ventilation flow, in particular where ventilation may be required to cool the ambient temperature in a deep hot mine, however auto-compression must also be taken into account. [1] As per CMR 153-2-(i)(2017), in every ventilating district not less than six cubic meters per minute of air per person employed in the district on the largest shift or not less than 2.5 cubic meters per minute of air per daily tons output whichever is larger, passes along the last ventilation connection in the district which means the inbye-most gallery in the district along which the air passes.

Heating

In temperate climates ventilation air may need to be heated during winter months. This will make the working environment more hospitable for miners, and prevent freezing of workings, in particular water pipes. In Arctic mines, where the mining horizon is above the permafrost, heating may not take place to prevent melting the permafrost. "Cold mines" such as Raglan Mine and Nanisivik Mine are designed to operate below 0 °C. [1]

The wet bulb temperature in any working place does not exceed 33.5 °C and where the wet bulb temperature exceeds 30.5 °C arrangements are made to ventilate the same with a current of air moving at a speed of not less than one meter per second.

Tunnels

In underground mining, long tunnels require efficient ventilation systems to protect miners' health and safety. ventilation shafts are critical in these setups, as they introduce fresh air into deeper sections and expel contaminated air. These shafts are typically placed at regular intervals along the tunnel to ensure that airflow reaches all parts of the mine. This distribution of airflow is essential for diluting hazardous gases, such as methane and carbon monoxide, which can accumulate in confined spaces and pose serious risks of explosion or poisoning.

In addition to air quality, tunnel ventilation plays a key role in temperature regulation. Heat generated by mining equipment and geological factors can make underground conditions extremely hot. Effective ventilation helps to maintain a more manageable temperature, enabling miners to work in safer, more comfortable conditions. Modern mine ventilation systems often combine both natural ventilation (using pressure and temperature differences to create airflow) and mechanical ventilation methods (using fans to circulate air) to optimize performance. [6]

Dust control is another important function of tunnel ventilation. Dust particles generated by drilling and blasting can impair visibility, clog equipment, and harm respiratory health. By directing fresh air through the tunnels, ventilation systems help to reduce dust concentration, improving air quality and visibility. Advanced ventilation designs are tailored to the specific layout and depth of the mine, ensuring that airflow requirements are met throughout the entire tunnel network.

Related Research Articles

<span class="mw-page-title-main">Heating, ventilation, and air conditioning</span> Technology of indoor and vehicular environmental comfort

Heating, ventilation, and air conditioning (HVAC) is the use of various technologies to control the temperature, humidity, and purity of the air in an enclosed space. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics, and heat transfer. "Refrigeration" is sometimes added to the field's abbreviation as HVAC&R or HVACR, or "ventilation" is dropped, as in HACR.

<span class="mw-page-title-main">Underground hard-rock mining</span> Mining techniques used to excavate hard minerals and gems

Underground hard-rock mining refers to various underground mining techniques used to excavate "hard" minerals, usually those containing metals, such as ore containing gold, silver, iron, copper, zinc, nickel, tin, and lead. It also involves the same techniques used to excavate ores of gems, such as diamonds and rubies. Soft-rock mining refers to the excavation of softer minerals, such as salt, coal, and oil sands.

<span class="mw-page-title-main">Adit</span> Horizontal entrance shaft to an underground mine

An adit or stulm is a horizontal or nearly horizontal passage to an underground mine. Miners can use adits for access, drainage, ventilation, and extracting minerals at the lowest convenient level. Adits are also used to explore for mineral veins. Although most strongly associated with mining, the term adit is sometimes also used in the context of underground excavation for non-mining purposes; for example, to refer to smaller underground passageways excavated for underground metro systems, to provide pedestrian access to stations, and for access required during construction.

<span class="mw-page-title-main">Ventilation (architecture)</span> Intentional introduction of outside air into a space

Ventilation is the intentional introduction of outdoor air into a space. Ventilation is mainly used to control indoor air quality by diluting and displacing indoor pollutants; it can also be used to control indoor temperature, humidity, and air motion to benefit thermal comfort, satisfaction with other aspects of the indoor environment, or other objectives.

<span class="mw-page-title-main">Mount Kembla</span> Suburb of Wollongong, New South Wales, Australia

Mount Kembla is a suburb and a mountain in the Illawarra region of New South Wales, Australia.

<span class="mw-page-title-main">Dust collector</span> Industrial machine

A dust collector is a system used to enhance the quality of air released from industrial and commercial processes by collecting dust and other impurities from air or gas. Designed to handle high-volume dust loads, a dust collector system consists of a blower, dust filter, a filter-cleaning system, and a dust receptacle or dust removal system. It is distinguished from air purifiers, which use disposable filters to remove dust.

Atkinson resistance is commonly used in mine ventilation to characterise the resistance to airflow of a duct of irregular size and shape, such as a mine roadway. It has the symbol and is used in the square law for pressure drop,

The stack effect or chimney effect is the movement of air into and out of buildings through unsealed openings, chimneys, flue-gas stacks, or other purposefully designed openings or containers, resulting from air buoyancy. Buoyancy occurs due to a difference in indoor-to-outdoor air density resulting from temperature and moisture differences. The result is either a positive or negative buoyancy force. The greater the thermal difference and the height of the structure, the greater the buoyancy force, and thus the stack effect. The stack effect can be useful to drive natural ventilation in certain climates, but in other circumstances may be a cause of unwanted air infiltration or fire hazard.

Blackdamp, sometimes found in enclosed environments such as mines, sewers, wells, tunnels and ships' holds, is an asphyxiant, reducing the available oxygen content of air to a level incapable of sustaining human or animal life. It is not a single gas but a mixture of unbreathable gases left after oxygen is removed from the air; it typically consists of nitrogen, carbon dioxide and water vapour. The term is etymologically and practically related to terms for other underground mine gases such as fire damp, white damp, stink damp, and afterdamp.

Clifton Hall Colliery was one of two coal mines in Clifton on the Manchester Coalfield, historically in Lancashire which was incorporated into the City of Salford in Greater Manchester, England in 1974. Clifton Hall was notorious for an explosion in 1885 which killed around 178 men and boys.

<span class="mw-page-title-main">Centrifugal fan</span> Mechanical fan that forces fluid to move radially outward

A centrifugal fan is a mechanical device for moving air or other gases in a direction at an angle to the incoming fluid. Centrifugal fans often contain a ducted housing to direct outgoing air in a specific direction or across a heat sink; such a fan is also called a blower, blower fan, or squirrel-cage fan. Tiny ones used in computers are sometimes called biscuit blowers. These fans move air from the rotating inlet of the fan to an outlet. They are typically used in ducted applications to either draw air through ductwork/heat exchanger, or push air through similar impellers. Compared to standard axial fans, they can provide similar air movement from a smaller fan package, and overcome higher resistance in air streams.

<span class="mw-page-title-main">Fan (machine)</span> Machine used to produce air flow

A fan is a powered machine used to create a flow of air. A fan consists of a rotating arrangement of vanes or blades, generally made of wood, plastic, or metal, which act on the air. The rotating assembly of blades and hub is known as an impeller, rotor, or runner. Usually, it is contained within some form of housing, or case. This may direct the airflow, or increase safety by preventing objects from contacting the fan blades. Most fans are powered by electric motors, but other sources of power may be used, including hydraulic motors, handcranks, and internal combustion engines.

<span class="mw-page-title-main">Industrial fan</span>

Industrial fans and blowers are machines whose primary function is to provide and accommodate a large flow of air or gas to various parts of a building or other structures. This is achieved by rotating a number of blades, connected to a hub and shaft, and driven by a motor or turbine. The flow rates of these mechanical fans range from approximately 200 cubic feet (5.7 m3) to 2,000,000 cubic feet (57,000 m3) per minute. A blower is another name for a fan that operates where the resistance to the flow is primarily on the downstream side of the fan.

Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour. Perfectly mixed air refers to a theoretical condition where supply air is instantly and uniformly mixed with the air already present in a space, so that conditions such as age of air and concentration of pollutants are spatially uniform.

Ventilation may refer to:

<span class="mw-page-title-main">Avondale Mine disaster</span>

The Avondale Mine disaster was a massive fire at the Avondale Colliery near Plymouth Township, Pennsylvania, on September 6, 1869. It caused the death of 110 workers. It started when the wooden lining of the mine shaft caught fire and ignited the coal breaker built directly overhead. The shaft was the only entrance and exit to the mine, and the fire trapped and suffocated 108 of the workers. It was the greatest mine disaster to that point in American history.

Airflow, or air flow, is the movement of air. Air behaves in a fluid manner, meaning particles naturally flow from areas of higher pressure to those where the pressure is lower. Atmospheric air pressure is directly related to altitude, temperature, and composition.

<span class="mw-page-title-main">Waddle fan</span> Large centrifugal fans, used to ventilate coal mines

Waddle fans, sometimes incorrectly spelled Waddell, were large centrifugal fans, used to ventilate coal mines.

This is a partial glossary of coal mining terminology commonly used in the coalfields of the United Kingdom. Some words were in use throughout the coalfields, some are historic and some are local to the different British coalfields.

<span class="mw-page-title-main">Mine safety</span> Practice of controlling mining hazards

Mine safety is a broad term referring to the practice of controlling and managing a wide range of hazards associated with the life cycle of mining-related activities. Mine safety practice involves the implementation of recognised hazard controls and/or reduction of risks associated with mining activities to legally, socially and morally acceptable levels. While the fundamental principle of mine safety is to remove health and safety risks to mine workers, mining safety practice may also focus on the reduction of risks to plant (machinery) together with the structure and orebody of the mine.

References

  1. 1 2 3 4 De la Vergne, Jack (2003). Hard Rock Miner's Handbook. Tempe/North Bay: McIntosh Engineering. p. 157. ISBN   978-0-9687006-1-7. Archived from the original on 2017-05-04. Retrieved 2008-10-21.
  2. MNCU1107A Implement the Ventilation Management Plan - Commonwealth of Australia 2001
  3. "Introduction to Mine Ventilating Principles and Practices" (PDF). www.cdc.gov. Retrieved 2024-10-02.
  4. Darling, Peter (2011). SME Mining Engineering Handbook. United States of America: Society for Mining, Metallurgy, and Exploration, Inc. p. 1583. ISBN   978-0-87335-264-2.
  5. books.google.co.in Mine Ventilation: Proceedings of the 10th US / North American Mine
  6. Wang, Hartman, Mutmansky, Ramani, "Y. J., Howard L., Jan M., Raja V. (November 1997). Mine Ventilation and Air Conditioning, 3rd Edition (3rd ed.). Wiley. ISBN   978-0-471-11635-6.{{cite book}}: CS1 maint: date and year (link) CS1 maint: multiple names: authors list (link)