An editor has performed a search and found that sufficient sources exist to establish the subject's notability.(April 2024) |
CC-Link Family of Open Automation Networks | |
---|---|
Protocol Information | |
Type of Network | Open fieldbus and industrial Ethernet |
Physical Media | RS485, optical fiber, Ethernet (gigabit & 100Mbit) |
Network Topology | bus, star, ring, line (depending on type) |
Governing Body | CC-Link Partner Association |
Website | cc-link |
The CC-Link Open Automation Networks Family are a group of open industrial networks that enable devices from numerous manufacturers to communicate. They are used in a wide variety of industrial automation applications at the machine, cell and line levels.
The CC-Link Partner Association (CLPA) offers a family of open-architecture networks. These originated with the CC-Link (Control & Communication) fieldbus in 1996, [1] developed by Mitsubishi Electric Corporation. In 2000, [1] this was released as an “Open” network so that independent automation equipment manufacturers could incorporate CLPA network compatibility into their products. In the same year, the CC-Link Partner Association (CLPA) was formed to manage and oversee the network technology and support manufacturer members. In 2007, [1] the CLPA was the first organisation to introduce open gigabit Ethernet for automation with CC-Link IE (Industrial Ethernet). In 2018, [1] the CLPA was the first organisation to combine open gigabit Ethernet with Time-Sensitive Networking (TSN) as CC-Link IE TSN. As of May 2020, over 2,100 CLPA compatible products from more than 340 automation manufacturers were available. CLPA offers a variety of open automation network technologies. These are the CC-Link fieldbus, CC-Link Safety fieldbus, CC-Link IE and CC-Link IE TSN. Compatible products include industrial PCs, PLCs, robots, servos, drives, valve manifolds, digital & analogue I/O modules, temperature controllers, mass flow controllers and others. As of May 2020, there was approximately 30 million devices installed worldwide.
The CLPA is a global organisation with branches in 11 locations worldwide (Japan, Taiwan, Singapore, Thailand, China, South Korea, India, Turkey, Germany, USA and Mexico). The headquarters are in Nagoya, Japan. Some branches offer conformance testing facilities (see below). The CLPA is controlled by a board of ten companies, who are 3M, Analog Devices, Balluff, Cisco, Cognex Corporation, IDEC Corporation, Mitsubishi Electric, Molex, NEC and Pro-face. The board controls the strategic direction of the organisation and oversees its operations, including the activities of the technical and marketing task forces and the global branches.
The CLPA has been involved in strategic cooperation with other open technology associations in the industrial automation space. These include PROFIBUS & PROFINET International (PI), the OPC Foundation and AutomationML. The cooperation with PI resulted in a standard for interoperability between CC-Link IE and PROFINET. [2] The OPC Foundation activity created an OPC UA companion specification for the CLPA's "CSP+ (Control & Communication System Profile) For Machine" technology. [3] Cooperation with AutomationML involved the signing of a Memorandum of Understanding to incorporate the "CSP+" and "CSP+ For Machine" device profile technologies into AutomationML models. [4]
CLPA has obtained the following certifications [5] for its open network technologies:
All certification testing [6] for CLPA networks is carried out by the CLPA and is compulsory in order to ensure that devices manufactured by suppliers meet the strict technical performance standards. These include noise resistance and correct communication functionality. To declare a product as CLPA certified, a vendor needs to successfully test their product at one of the CLPA test laboratories situated in the US, China, Korea, Japan or Germany.
A distributed control system (DCS) is a computerized control system for a process or plant usually with many control loops, in which autonomous controllers are distributed throughout the system, but there is no central operator supervisory control. This is in contrast to systems that use centralized controllers; either discrete controllers located at a central control room or within a central computer. The DCS concept increases reliability and reduces installation costs by localizing control functions near the process plant, with remote monitoring and supervision.
Profibus is a standard for fieldbus communication in automation technology and was first promoted in 1989 by BMBF and then used by Siemens. It should not be confused with the Profinet standard for Industrial Ethernet. Profibus is openly published as type 3 of IEC 61158/61784-1.
Open Platform Communications (OPC) is a series of standards and specifications for industrial telecommunication. They are based on Object Linking and Embedding (OLE) for process control. An industrial automation task force developed the original standard in 1996 under the name OLE for Process Control. OPC specifies the communication of real-time plant data between control devices from different manufacturers.
The OPC Foundation is an industry consortium that creates and maintains standards for open connectivity of industrial automation devices and systems, such as industrial control systems and process control generally. The OPC standards specify the communication of industrial process data, alarms and events, historical data and batch process data between sensors, instruments, controllers, software systems, and notification devices.
A fieldbus is a member of a family of industrial digital communication networks used for real-time distributed control. Fieldbus profiles are standardized by the International Electrotechnical Commission (IEC) as IEC 61784/61158.
Industrial Ethernet (IE) is the use of Ethernet in an industrial environment with protocols that provide determinism and real-time control. Protocols for industrial Ethernet include EtherCAT, EtherNet/IP, PROFINET, POWERLINK, SERCOS III, CC-Link IE, and Modbus TCP. Many industrial Ethernet protocols use a modified media access control (MAC) layer to provide low latency and determinism. Some microprocessors provide industrial Ethernet support.
Fieldbus Foundation was an organization dedicated to a single international, interoperable fieldbus standard. It was established in September 1994 by a merger of WorldFIP North America and the Interoperable Systems Project (ISP). Fieldbus Foundation was a not-for-profit trade consortium that consisted of more than 350 of the world's suppliers and end users of process control and manufacturing automation products. Working together those companies made contributions to the IEC/ISA/FDI and other fieldbus standards development.
Foundation Fieldbus is an all-digital, serial, two-way communications system that serves as the base-level network in a plant or factory automation environment. It is an open architecture, developed and administered by FieldComm Group.
Actuator Sensor Interface is an industrial networking solution used in PLC, DCS and PC-based automation systems. It is designed for connecting simple field I/O devices in discrete manufacturing and process applications using a single two-conductor cable.
Profinet is an industry technical standard for data communication over Industrial Ethernet, designed for collecting data from, and controlling equipment in industrial systems, with a particular strength in delivering data under tight time constraints. The standard is maintained and supported by Profibus and Profinet International, an umbrella organization headquartered in Karlsruhe, Germany.
EtherCAT is an Ethernet-based fieldbus system developed by Beckhoff Automation. The protocol is standardized in IEC 61158 and is suitable for both hard and soft real-time computing requirements in automation technology.
EtherNet/IP is an industrial network protocol that adapts the Common Industrial Protocol (CIP) to standard Ethernet. EtherNet/IP is one of the leading industrial protocols in the United States and is widely used in a range of industries including factory, hybrid and process. The EtherNet/IP and CIP technologies are managed by ODVA, Inc., a global trade and standards development organization founded in 1995 with over 300 corporate members.
Profisafe is a standard for a communication protocol for the transmission of safety-relevant data in automation applications with functional safety. This standard was developed jointly by several automation device manufacturers in order to be able to meet the requirements of the legislator and the IFA for safe systems. The required safe function of the protocol has been tested and confirmed by TÜV Süd. The PROFIBUS Nutzerorganisation e.V. in Karlsruhe supervises the standardization for the partner companies and organizes the promotion of this common interface.
Codesys is an integrated development environment for programming controller applications according to the international industrial standard IEC 61131-3.
Sercos III is the third generation of the Sercos interface, a standardized open digital interface for the communication between industrial controls, motion devices, input/output devices (I/O), and Ethernet nodes, such as PCs. Sercos III applies the hard real-time features of the Sercos interface to Ethernet. It is based upon and conforms to the Ethernet standard. Work began on Sercos III in 2003, with vendors releasing first products supporting it in 2005.
Phoenix Contact, headquartered in Blomberg, Ostwestfalen-Lippe, Germany, is a manufacturer of industrial automation, interconnection, and interface solutions. The company develops terminal blocks, relays, connectors, signal conditioners, power supplies, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression. In addition, Phoenix Contact manufactures products for use with Modbus, DeviceNet, EtherNet/IP, CANopen, PROFIBUS and PROFINET networks.
RAPIEnet was Korea's first Ethernet international standard for real-time data transmission. It is an Ethernet-based industrial networking protocol, developed in-house by LSIS offers real-time transmission and is registered as an international standard.
Avnu Alliance is a consortium of member companies working together to create an interoperable ecosystem of low-latency, time-synchronized, highly reliable networking devices using the IEEE open standard, Time-Sensitive Networking (TSN) and its Pro AV networking protocol, Milan. Avnu Alliance creates comprehensive certification programs to ensure interoperability of network devices. In the Professional Audio Video (AV) industry, Alliance member companies worked together to develop Milan: a standards-based, user-driven deterministic network protocol for professional media, that through certification, assures devices will work together at new levels of convenience, reliability, and functionality. Milan™ is a standards-based deterministic network protocol for real time media. Avnu Members may use the Avnu-certified or Milan-certified logo on devices that pass the conformance tests from Avnu. Not every device based on AVB or TSN is submitted for certification to the Avnu Alliance. The lack of the Avnu logo does not necessarily imply a device is incompatible with other Avnu-certified devices. The Alliance, in conjunction with other complimentary standards bodies and alliances, provides a united network foundation for use in professional AV, automotive, industrial control and consumer segments.
IO-Link is a short distance, bi-directional, digital, point-to-point, wired, industrial communications networking standard used for connecting digital sensors and actuators to either a type of industrial fieldbus or a type of industrial Ethernet. Its objective is to provide a technological platform that enables the development and use of sensors and actuators that can produce and consume enriched sets of data that in turn can be used for economically optimizing industrial automated processes and operations. The technology standard is managed by the industry association Profibus and Profinet International.