X10 is a protocol for communication among electronic devices used for home automation (domotics). It primarily uses power line wiring for signaling and control, where the signals involve brief radio frequency bursts representing digital information. A wireless radio-based protocol transport is also defined.

Contents

X10 was developed in 1975 by Pico Electronics of Glenrothes, Scotland, in order to allow remote control of home devices and appliances. It was the first general purpose home automation network technology and remains the most widely available[ citation needed ]. [1]

Although a number of higher-bandwidth alternatives exist, X10 remains popular in the home environment with millions of units in use worldwide, and inexpensive availability of new components.

History

In 1970, a group of engineers started a company in Glenrothes, Scotland called Pico Electronics. [2] The company developed the first single chip calculator. [1] When calculator integrated circuit prices started to fall, Pico refocused on commercial products rather than plain ICs.

In 1974, the Pico engineers jointly developed an LP record turntable, the ADC Accutrac 4000, with Birmingham Sound Reproducers, at the time the largest manufacturer of record changers in the world. It could be programmed to play selected tracks, and could be operated by a remote control using ultrasound signals, which sparked the idea of remote control for lights and appliances. By 1975, the X10 project was conceived, so named because it was the tenth project. In 1978, X10 products started to appear in RadioShack and Sears stores. Together with BSR a partnership was formed, with the name X10 Ltd. At that time the system consisted of a 16 channel command console, a lamp module, and an appliance module. Soon after came the wall switch module and the first X10 timer.

In the 1980s, the CP-290 computer interface was released. Software for the interface runs on the Commodore 64, Apple II, classic Mac OS, MS-DOS, and Microsoft Windows.

In 1985, BSR went out of business, and X10 (USA) Inc. was formed. In the early 1990s, the consumer market was divided into two main categories, the ultra-high-end with a budget at US$100,000 and the mass market with budgets at US$2,000 to US$35,000. CEBus (1984) and LonWorks (1991) were attempts to improve reliability and replace X10.

Brands

X10 components have been sold under a variety of brand names:

Many of these vendors have since exited this business.

Power line carrier control overview

X10 modules: The interior of an appliance module (note the impulse relay on the left) and a lamp module (note the TRIAC and heat sink) X10 5.jpg
X10 modules: The interior of an appliance module (note the impulse relay on the left) and a lamp module (note the TRIAC and heat sink)

Household electrical wiring which powers lights and appliances is used to send digital data between X10 devices. This data is encoded onto a 120 kHz carrier which is transmitted as bursts during the relatively quiet zero crossings of the 50 or 60 Hz AC alternating current waveform. One bit is transmitted at each zero crossing. [3]

The digital data consists of an address and a command sent from a controller to a controlled device. More advanced controllers can also query equally advanced devices to respond with their status. This status may be as simple as "off" or "on", or the current dimming level, or even the temperature or other sensor reading. Devices usually plug into the wall where a lamp, television, or other household appliance plugs in; however some built-in controllers are also available for wall switches and ceiling fixtures.

The relatively high-frequency carrier wave carrying the signal cannot pass through a power transformer or across the phases of a multiphase system. For split phase systems, the signal can be passively coupled from leg-to-leg using a passive capacitor, but for three phase systems or where the capacitor provides insufficient coupling, an active X10 repeater can be used. To allow signals to be coupled across phases and still match each phase's zero crossing point, each bit is transmitted three times in each half cycle, offset by 1/6 cycle.

It may also be desirable to block X10 signals from leaving the local area so, for example, the X10 controls in one house do not interfere with the X10 controls in a neighboring house. In this situation, inductive filters can be used to attenuate the X10 signals coming into or going out of the local area.

Protocol

Whether using power line or radio communications, packets transmitted using the X10 control protocol consist of a four bit house code followed by one or more four bit unit codes, finally followed by a four bit command. For the convenience of users configuring a system, the four bit house code is selected as a letter from A through P while the four bit unit code is a number 1 through 16.

When the system is installed, each controlled device is configured to respond to one of the 256 possible addresses (16 house codes × 16 unit codes); each device reacts to commands specifically addressed to it, or possibly to several broadcast commands.

The protocol may transmit a message that says "select code A3", followed by "turn on", which commands unit "A3" to turn on its device. Several units can be addressed before giving the command, allowing a command to affect several units simultaneously. For example, "select A3", "select A15", "select A4", and finally, "turn on", causes units A3, A4, and A15 to all turn on.

Note that there is no restriction that prevents using more than one house code within a single house. The "all lights on" command and "all units off" commands will only affect a single house code, so an installation using multiple house codes effectively has the devices divided into separate zones.

One-way vs two-way

Inexpensive X10 devices only receive commands and do not acknowledge their status to the rest of the network. Two-way controller devices allow for a more robust network but cost two to four times more and require two-way X10 devices. [4]

List of X10 commands

CodeFunctionDescriptionOne WayTwo Way
0 0 0 0All units offSwitch off all devices with the house code indicated in the messageX
0 0 0 1All lights onSwitches on all lighting devices (with the ability to control brightness)X
0 1 1 0All lights offSwitches off all lighting devicesX
0 0 1 0OnSwitches on a deviceX
0 0 1 1OffSwitches off a deviceX
0 1 0 0DimReduces the light intensityX
0 1 0 1BrightIncreases the light intensityX
0 1 1 1Extended codeExtension codeX
1 0 0 0Hail requestRequests a response from the device(s) with the house code indicated in the messageX
1 0 0 1Hail acknowledgementResponse to the previous commandX
1 0 1 0Pre-set dimAllows the selection of two predefined levels of light intensityX
1 1 0 1Status is onResponse to the Status Request indicating that the device is switched onX
1 1 1 0Status is offResponse indicating that the device is switched offX
1 1 1 1Status requestRequest requiring the status of a deviceX

List of X10 house and unit code encodings

Note that the binary values for the house and unit codes correspond, but they are not a straight binary sequence. A unit code is followed by one additional "0" bit to distinguish from a command code (detailed above).

House CodeUnit CodeBinary Value
A10 1 1 0
B21 1 1 0
C30 0 1 0
D41 0 1 0
E50 0 0 1
F61 0 0 1
G70 1 0 1
H81 1 0 1
I90 1 1 1
J101 1 1 1
K110 0 1 1
L121 0 1 1
M130 0 0 0
N141 0 0 0
O150 1 0 0
P161 1 0 0

Physical layer details

In the 60 Hz AC current flow, each bit transmitted requires two zero crossings. A "1" bit is represented by an active zero crossing followed by an inactive zero crossing. A "0" bit is represented by an inactive zero crossing followed by an active zero crossing. An active zero crossing is represented by a 1 millisecond burst of 120 kHz at the zero crossing point (nominally 0°, but within 200 microseconds of the zero crossing point). An inactive zero crossing will not have a pulse of 120 kHz signal.

In order to provide a predictable start point, every data frame transmitted always begins with a start code of three active zero crossings followed by an inactive crossing. Since all data bits are sent as one active and one inactive (or one inactive and one active) zero crossing, the start code, possessing three active crossings in a row, can be uniquely detected. Many X10 protocol charts represent this start code as "1110", but it is important to realize that is in terms of zero crossings, not data bits.

Immediately after the start code, a 4-bit house code (normally represented by the letters A to P on interface units) appears, and after the house code comes a 5-bit function code. Function codes may specify a unit number code (1–16) or a command code. The unit number or command code occupies the first 4 of the 5 bits. The final bit is a 0 for a unit code and a 1 for a command code. Multiple unit codes may be transmitted in sequence before a command code is finally sent. The command will be applied to all unit codes sent. It is also possible to send a message with no unit codes, just a house code and a command code. This will apply to the command to the last group of units codes previously sent.

One start code, one house code, and one function code is known as an X10 frame and represent the minimum components of a valid X10 data packet.

Each frame is sent twice in succession to make sure the receivers understand it over any power line noise for purposes of redundancy, reliability, and to accommodate line repeaters. After allowing for retransmission, line control, etc., data rates are around 20 bit/s, making X10 data transmission so slow that the technology is confined to turning devices on and off or other very simple operations.

Whenever the data changes from one address to another address, from an address to a command, or from one command to another command, the data frames must be separated by at least 6 clear zero crossings (or "000000"). The sequence of six zeros resets the device decoder hardware.

Later developments (1997) of hardware are improvements of the native X10 hardware. In Europe (2001) for the 230 VAC 50 Hz market. All improved products use the same X10 protocol and are compatible.

RF protocol

A four-channel radio switch and radio-to-power-line transponder X10 3.jpg
A four-channel radio switch and radio-to-power-line transponder

To allow for wireless keypads, remote switches, motion sensors, et cetera, an RF protocol is also defined. X10 wireless devices send data packets that are nearly identical to the NEC IR protocol used by many IR remotes, and a radio receiver then provides a bridge which translates these radio packets to ordinary X10 power line control packets. The wireless protocol operates at a frequency of 310  MHz in the U.S. and 433.92 MHz in European systems.

The devices available using the radio protocol include:

Hardware support

Device modules

X10 modules: A lamp socket module X10 4.jpg
X10 modules: A lamp socket module

Depending on the load that is to be controlled, different modules must be used. For incandescent lamp loads, a lamp module or wall switch module can be used. These modules switch the power using a TRIAC solid state switch and are also capable of dimming the lamp load. Lamp modules are almost silent in operation, and generally rated to control loads ranging from approximately 60 to 500 watts.

For loads other than incandescent lamps, such as fluorescent lamps, high-intensity discharge lamps, and electrical home appliances, the triac-based electronic switching in the lamp module is unsuitable and an appliance module must be used instead. These modules switch the power using an impulse relay. In the U.S., these modules are generally rated to control loads up to 15 amperes (1800 watts at 120 V).

Many device modules offer a feature called local control. If the module is switched off, operating the power switch on the lamp or appliance will cause the module to turn on. In this way, a lamp can still be lit or a coffee pot turned on without the need to use an X10 controller. Wall switch modules may not offer this feature. As a result, older Appliance modules may fail to work with, for example, a very low load such as a 5W LED table lamp.

Some wall switch modules offer a feature called local dimming. Ordinarily, the local push button of a wall switch module simply offers on/off control with no possibility of locally dimming the controlled lamp. If local dimming is offered, holding down the push button will cause the lamp to cycle through its brightness range.

Higher end modules have more advanced features such as programmable on levels, customizable fade rates, the ability to transmit commands when used (referred to as 2-way devices), and scene support.

There are sensor modules that sense and report temperature, light, infrared, motion, or contact openings and closures. Device modules include thermostats, audible alarms and controllers for low voltage switches.

Controllers

X10 controllers: A simple controller (bottom left), a radio controller (top center), and an original controller (bottom right) usable with an ultrasonic remote control X10 2.jpg
X10 controllers: A simple controller (bottom left), a radio controller (top center), and an original controller (bottom right) usable with an ultrasonic remote control

X10 controllers range from extremely simple to very sophisticated.

The simplest controllers are arranged to control four X10 devices at four sequential addresses (1–4 or 5–8). The controllers typically contain the following buttons:

More sophisticated controllers can control more units and/or incorporate timers that perform preprogrammed functions at specific times each day. Units are also available that use passive infrared motion detectors or photocells to turn lights on and off based on external conditions.

Finally, there are very sophisticated units are available that can be fully programmed and/or controlled with a piece of software called Active Home, such as the CM11A serial interface. These systems can execute many different timed events, respond to external sensors, and execute, with the press of a single button, an entire scene, turning lights on, establishing brightness levels, and so on. Control programs are available for computers running Microsoft Windows, Apple's Macintosh, Linux and FreeBSD operating systems.

Burglar alarm systems are also available. These systems contain door/window sensors, as well as motion sensors that use a coded radio frequency (RF) signal to identify when they are tripped or just to routinely check-in and give a heart-beat signal to show that the system is still active. Users can arm and disarm their system via several different remote controls that also use a coded RF signal to ensure security. When an alarm is triggered the console will make an outbound telephone call with a recorded message. The console will also use X10 protocols to flash lights when an alarm has been triggered while the security console sounds an external siren. Using X10 protocols, signals will also be sent to remote sirens for additional security.

Bridges

There are bridges to translate X10 to other home automation standards (e.g., KNX). ioBridge can be used to translate the X10 protocol to a web service API via the X10 PSC04 Powerline Interface Module. The magDomus home controller from magnocomp allows interconnection and inter-operation between most home automation technologies.

Thermostat

With X10 being an open standard, companies such as RCS released an x10 controllable thermostat model TX15-B, which is controllable via a web interface or a computer running a X10 software such as HAL or HomeSeer.

Limitations

Compatibility

Solid-state switches used in X10 controls pass a very small leakage current. Compact fluorescent lamps may display nuisance blinking when switched off; CFL manufacturers recommend against controlling lamps with solid-state timers or remote controls.

Some X10 controllers with triac solid-state outputs may not work well with low power devices (below 50 watts) or devices like fluorescent bulbs due to the leakage current of the device. An appliance module, using a relay with metallic contacts may resolve this problem. Many older appliance units have a 'local control' feature whereby the relay is intentionally bypassed with a high value resistor; the module can then sense the appliance's own switch and turn on the relay when the local switch is operated. This sense current may be incompatible with LED or CFL lamps.

Not all devices can be used on a dimmer. Fluorescent lamps are not dimmable with incandescent lamp dimmers; certain models of compact fluorescent lamps are dimmable but cost more. Motorized appliances such as fans, etc. generally will not operate as expected on a dimmer.

Wiring and interfering sources

One problem with X10 is excessive attenuation of signals between the two live conductors in the 3-wire 120/240 volt system used in typical North American residential construction. Signals from a transmitter on one live conductor may not propagate through the high impedance of the distribution transformer winding to the other live conductor. Often, there's simply no reliable path to allow the X10 signals to propagate from one transformer leg wire to the other; this failure may come and go as large 240 volt devices such as stoves or dryers are turned on and off. (When turned on, such devices provide a low-impedance bridge for the X10 signals between the two leg wires.) This problem can be permanently overcome by installing a capacitor between the leg wires as a path for the X10 signals; manufacturers commonly sell signal couplers that plug into 240 volt sockets that perform this function. More sophisticated installations install an active repeater device between the legs, while others combine signal amplifiers with a coupling device. A repeater is also needed for inter-phase communication in homes with three-phase electric power. In many countries outside North America, entire houses are typically wired from a single 240 volt single-phase wire, so this problem does not occur.

Television receivers or household wireless devices may cause spurious "off" or "on" signals. Noise filtering (as installed on computers as well as many modern appliances) may help keep external noise out of X10 signals, but noise filters not designed for X10 may also attenuate X10 signals traveling on the branch circuit to which the appliance is connected.

Certain types of power supplies used in modern electronic equipment, such as computers, television receivers and satellite receivers, attenuate passing X10 signals by providing a low impedance path to high frequency signals. Typically, the capacitors used on the inputs to these power supplies short the X10 signal from line to neutral, suppressing any hope of X10 control on the circuit near that device. Filters are available that will block the X10 signals from ever reaching such devices; plugging offending devices into such filters can cure mysterious X10 intermittent failures.

Having a backup power supply or standby power supply such as used with computers or other electronic devices can totally kill that leg in a household installation because of the filtering used in the power supply.

Commands getting lost

X10 signals can only be transmitted one command at a time, first by addressing the device to control, and then sending an operation for that device to perform. If two X10 signals are transmitted at the same time they may collide or interleave, leading to commands that either cannot be decoded or that trigger incorrect operations. The CM15A and RR501 Transceiver can avoid these signal collisions that can sometimes occur with other models.

Lack of speed

The X10 protocol is slow. It takes roughly three quarters of a second to transmit a device address and a command. While generally not noticeable when using a tabletop controller, it becomes a noticeable problem when using 2-way switches or when utilizing some sort of computerized controller. The apparent delay can be lessened somewhat by using slower device dim rates. With more advanced modules another option is to use group control (lighting scene) extended commands. These allow adjusting several modules at once by a single command.

Limited functionality

X10 protocol does support more advanced control over the dimming speed, direct dim level setting and group control (scene settings). This is done via extended message set, which is an official part of X10 standard. However support for all extended messages is not mandatory, and many cheaper modules implement only the basic message set. These require adjusting each lighting circuit one after the other, which can be visually unappealing and also very slow.

Interference and lack of encryption

The standard X10 power line and RF protocols lack support for encryption, and can only address 256 devices. Unfiltered power line signals from close neighbors using the same X10 device addresses may interfere with each other. Interfering RF wireless signals may similarly be received, with it being easy for anyone nearby with an X10 RF remote to wittingly or unwittingly cause mayhem if an RF to power line device is being used on a premises.

See also

Related Research Articles

<span class="mw-page-title-main">Remote control</span> Device used to control other device remotely

In electronics, a remote control is an electronic device used to operate another device from a distance, usually wirelessly. In consumer electronics, a remote control can be used to operate devices such as a television set, DVD player or other digital home media appliance. A remote control can allow operation of devices that are out of convenient reach for direct operation of controls. They function best when used from a short distance. This is primarily a convenience feature for the user. In some cases, remote controls allow a person to operate a device that they otherwise would not be able to reach, as when a garage door opener is triggered from outside.

<span class="mw-page-title-main">CAN bus</span> Standard for serial communication between devices without host computer

A controller area network (CAN) is a vehicle bus standard designed to enable efficient communication primarily between electronic control units (ECUs). Originally developed to reduce the complexity and cost of electrical wiring in automobiles through multiplexing, the CAN bus protocol has since been adopted in various other contexts. This broadcast-based, message-oriented protocol ensures data integrity and prioritization through a process called arbitration, allowing the highest priority device to continue transmitting if multiple devices attempt to send data simultaneously, while others back off. Its reliability is enhanced by differential signaling, which mitigates electrical noise. Common versions of the CAN protocol include CAN 2.0, CAN FD, and CAN XL which vary in their data rate capabilities and maximum data payload sizes.

<span class="mw-page-title-main">Power-line communication</span> Data network that uses electrical wiring

Power-line communication (PLC) is the carrying of data on a conductor that is also used simultaneously for AC electric power transmission or electric power distribution to consumers. The line that does so is known as a power-line carrier.

<span class="mw-page-title-main">DMX512</span> Digital communication network standard for controlling stage lighting and effects

DMX512 is a standard for digital communication networks that are commonly used to control lighting and effects. It was originally intended as a standardized method for controlling stage lighting dimmers, which, prior to DMX512, had employed various incompatible proprietary protocols. It quickly became the primary method for linking controllers to dimmers and special effects devices such as fog machines and intelligent lights.

<span class="mw-page-title-main">Dimmer</span> Engineering device

A dimmer is a device connected to a light fixture and used to lower the brightness of the light. By changing the voltage waveform applied to the lamp, it is possible to lower the intensity of the light output. Although variable-voltage devices are used for various purposes, the term dimmer is generally reserved for those intended to control light output from resistive incandescent, halogen, and compact fluorescent lamps (CFLs) and light-emitting diodes (LEDs). More specialized equipment is needed to dim fluorescent, mercury-vapor, solid-state, and other arc lighting.

MIL-STD-1553 is a military standard published by the United States Department of Defense that defines the mechanical, electrical, and functional characteristics of a serial data bus. It was originally designed as an avionic data bus for use with military avionics, but has also become commonly used in spacecraft on-board data handling (OBDH) subsystems, both military and civil, including use on the James Webb space telescope. It features multiple redundant balanced line physical layers, a (differential) network interface, time-division multiplexing, half-duplex command/response protocol, and can handle up to 31 Remote Terminals (devices); 32 is typically designated for broadcast messages. A version of MIL-STD-1553 using optical cabling in place of electrical is known as MIL-STD-1773.

<span class="mw-page-title-main">Fire alarm control panel</span> Controlling component of a fire alarm system

A fire alarm control panel (FACP), fire alarm control unit (FACU), fire indicator panel (FIP), or simply fire alarm panel is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operational integrity, and provides for automatic control of equipment, and transmission of information necessary to prepare the facility for fire based on a predetermined sequence. The panel may also supply electrical energy to operate any associated initiating device, notification appliance, control, transmitter, or relay. There are four basic types of panels: coded panels, conventional panels, addressable panels, and multiplex systems.

<span class="mw-page-title-main">EnOcean</span> Energy harvesting wireless technology

The EnOcean technology is an energy harvesting wireless technology used primarily in building automation systems, but also in other application fields such as industry, transportation, and logistics. The energy harvesting wireless modules are manufactured and marketed by the company EnOcean, headquartered in Oberhaching near Munich. The modules combine micro energy converters with ultra low power electronics and wireless communications and enable batteryless, wireless sensors, switches, and controls.

CEBus(r), short for Consumer Electronics Bus, also known as EIA-600, is a set of electrical standards and communication protocols for electronic devices to transmit commands and data. It is suitable for devices in households and offices to use, and might be useful for utility interface and light industrial applications.

Building automation (BAS), also known as building management system (BMS) or building energy management system (BEMS), is the automatic centralized control of a building's HVAC, electrical, lighting, shading, access control, security systems, and other interrelated systems. Some objectives of building automation are improved occupant comfort, efficient operation of building systems, reduction in energy consumption, reduced operating and maintaining costs and increased security.

<span class="mw-page-title-main">Profinet</span> Computer network protocol

Profinet is an industry technical standard for data communication over Industrial Ethernet, designed for collecting data from, and controlling equipment in industrial systems, with a particular strength in delivering data under tight time constraints. The standard is maintained and supported by Profibus and Profinet International, an umbrella organization headquartered in Karlsruhe, Germany.

<span class="mw-page-title-main">Lighting control system</span> Intelligent network based lighting control

A lighting control system incorporates communication between various system inputs and outputs related to lighting control with the use of one or more central computing devices. Lighting control systems are widely used on both indoor and outdoor lighting of commercial, industrial, and residential spaces. Lighting control systems are sometimes referred to under the term smart lighting. Lighting control systems serve to provide the right amount of light where and when it is needed.

Universal Powerline Bus (UPB) is a proprietary software protocol developed by Powerline Control Systems for power-line communication between devices used for home automation. Household electrical wiring is used to send digital data between UPB devices via pulse-position modulation.

C-Bus is a communications protocol based on a seven-layer OSI model for home and building automation that can handle cable lengths up to 1000 metres using Cat-5 cable. It is used in Australia, New Zealand, Asia, the Middle East, Russia, United States, South Africa, the UK and, other parts of Europe including Greece and Romania. C-Bus was created by Clipsal Australia's Clipsal Integrated Systems division for use with its brand of home automation and building lighting control system. C-Bus has been briefly available in the United States but Schneider Electric has now discontinued sales in the United States.

Digital model railway control systems are an alternative to control a layout and simplify the wiring and add more flexibility in operations. A number of control systems are available to operate locomotives on model railways. Analog systems where the speed and the direction of a train is controlled by adjusting the voltage on the track are still popular while they have recently given way to control systems based on computer technology.

OpenTherm (OT) is a standard communications protocol used in central heating systems for the communication between a central heating appliances and a thermostatic controller. As a standard, OpenTherm is independent of any single manufacturer. A controller from manufacturer A can in principle be used to control a boiler from manufacturer B. However, OpenTherm controllers and boilers do not always work properly together. The OpenTherm standard comprises a number of optional features and some devices may include manufacturer-specific features. The presence or absence of such features may impair compatibility with other OpenTherm devices.

PLCBUS or PLC-BUS is a proprietary power-line communication protocol for communication between electronic devices used for home automation. It primarily uses power line wiring for signaling and control.

<span class="mw-page-title-main">RF module</span> Electronic device to transmit and receive RF signals

An RF module is a (usually) small electronic device used to transmit and/or receive radio signals between two devices. In an embedded system it is often desirable to communicate with another device wirelessly. This wireless communication may be accomplished through optical communication or through radio-frequency (RF) communication. For many applications, the medium of choice is RF since it does not require line of sight. RF communications incorporate a transmitter and a receiver. They are of various types and ranges. Some can transmit up to 500 feet. RF modules are typically fabricated using RF CMOS technology.

<span class="mw-page-title-main">DOLLx8</span> Embedded system architecture

Digital One Line Link (DOLLx8) is a technology architecture that consists of data communication protocol, synchronous serial data bus and a communication system for embedded systems and electronics. DOLLx8 use ASCII characters in its data protocol, differential signaling in the bus system, where the communication consists of an active long-distance technology based on system logic where handling of the communication is done automatically by the microcontroller and its internal embedded Real-time operating system (RTOS) and software.

A smart home hub, sometimes also referred to as a "smart hub", "gateway'", "bridge", "controller" or "coordinator", is a control center/centre for a smart home, and enables the components of a smart home to communicate and respond to each other via communication through a central point. The smart home hub can consist of dedicated computer appliance, software appliance, or software running on computer hardware, and makes it possible to gather configuration, automation and monitoring of a smart house by communicating and controlling different smart devices that consist of for example home appliances, sensors and relays or robots, many of which are commonly categorized under Internet of things.

References

  1. 1 2 Rye, Dave (October 1999). "My Life at X10". AV and Automation Industry eMagazine. Archived from the original on 2016-10-15. Retrieved October 10, 2019.
  2. The history of X10
  3. "How X10 Works". www.smarthomeusa.com. Archived from the original on 2019-04-02. Retrieved 2016-03-08.
  4. "One way vs two way modules - Home Technology Information - hmtech.info". automation.hmtech.info. Retrieved 2016-03-08.