ARINC 818

Last updated

ARINC 818: Avionics Digital Video Bus (ADVB) is a video interface and protocol standard developed for high bandwidth, low-latency, uncompressed digital video transmission in avionics systems. The standard, which was released in January 2007, has been advanced by ARINC and the aerospace community to meet the stringent needs of high performance digital video. The specification was updated and ARINC 818-2 was released in December 2013, adding a number of new features, including link rates up to 32X fibre channel rates, channel-bonding, switching, field sequential color, bi-directional control and data-only links.

Contents

ARINC 818-3 was released in 2018. This revision clarified the 8b/10b encoding rates versus the 64b/66b encoding rates, along with clarifying several issues.

Although simplified, ADVB retains attributes of Fibre Channel that are beneficial for mission-critical applications: High Speed / High Reliability / Low Latency / Flexibility / High-Performance / Uncompressed Digital Video Transmission

Benefits of ARINC 818 (ADVB):

Background

In aircraft, an ever-increasing amount of information is supplied in the form of images, this information passes through a complex video system before reaching cockpit displays. Video systems include: infrared and other wavelength sensors, optical cameras, radar, flight recorders, map/chart systems, synthetic vision, image fusion systems, heads-up displays (HUD) and heads-down primary flight and multifunction displays, video concentrators, and other subsystems. Video systems are used for taxi and take-off assist, cargo loading, navigation, target tracking, collision avoidance, and other critical functions.

ARINC 818 (ADVB) is a Fibre Channel (FC) protocol that builds on FC-AV (Fibre Channel Audio Video, defined in ANSI INCITS 356-2002), which was used extensively on video systems in the F-18 and the C-130AMP. Although FC-AV has been used on numerous programs, each implementation has been unique. ARINC 818 provides an opportunity to standardize high-speed video systems and has since been adopted by a number of high-profile commercial and military aerospace programs, including the A400M, A350XWB, B787, KC-46A, C-130, KF-X, Comac C919, and numerous other programs. ARINC 818 is also common in avionics suites, such as Proline Fusion by Rockwell Collins, and the TopDeck by Thales.

Overview of ARINC 818 protocol

ARINC 818 (Avionics Digital Video Bus) is a point-to-point, 8b/10b-encoded (or 64B/66B for higher speeds) serial protocol for transmission of video, audio, and data. The protocol is packetized but is video-centric and very flexible, supporting an array of complex video functions including the multiplexing of multiple video streams on a single link or the transmission of a single stream over a dual link. Four different synchronization classes of video are defined, from simple asynchronous to stringent pixel synchronous systems.

ARINC 818 (ADVB) is unidirectional, and does not require handshaking.

ARINC 818 (ADVB) has 15 defined speeds—from 1 Gbit/s to 28 Gbit/s.

Each ADVB project requires an Interface Control Document (ICD). Shared among all project members, the ICD ensures interoperability, reduces the implementation magnitude, and defines:

ADVB Packet Structure

The ARINC 818 (ADVB) frame is the basic transport mechanism for ARINC 818. It is important to refer to these packets as “ADVB frames” rather than simply “frames” to eliminate potential confusion with video frames.

The start of an ADVB frame is signaled by a SOFx 4-byte ordered set and terminated with an EOFx ordered set. Every ADVB frame has a standard Fibre Channel header composed of six 32-bit words. These header words pertain to such things as the ADVB frame origin and intended destination and the ADVB frames position within the sequence. The Source ID field (SID) in the ADVB frame header allows video from each sensor to be distinguished from the other sensors.

The “payload” contains either video, video parameters or ancillary data. The payload can vary in size, but is limited to 2112 bytes per ADVB frame. To insure data integrity, all ADVB frames have a 32-bit CRC calculated for data between the SOFx and the CRC word. The CRC is the same 32-bit polynomial calculation defined for Fibre Channel.

ADVB container structure

The ARINC 818 (ADVB) specification defines a “container” as a set of ADVB frames used to transport video. In other words, a video image and data is encapsulated into a “container” that spans many ADVB frames. The “payload” of each ADVB frame contains either data or video. Within a container, ARINC 818 defines objects that contain certain types of data. That is, certain ADVB frames within the container are part of an object.

An example of how ARINC 818 transmits color XGA provides a good overview. XGA RGB requires ~141M bytes/s of data transfer (1024 pixels x 3 bytes per pixel x 768 lines x 60 Hz). Adding the protocol overhead and blanking time, a standard link rate of 2.125 Gbit/s is required. ARINC 818 “packetizes” video images into Fibre Channel frames. Each FC frame begins with a 4 byte ordered set, called an SOF (Start of Frame), and ends with an EOF (End of Frame), additionally, a 4 byte CRC is included for data integrity. The payload of the first ADVB frame in a sequence contains container header data that accompanies each video image.

Each XGA video line requires 3072 bytes, which exceeds the maximum FC payload length, so each line is divided into two ADVB frames. Transporting an XGA image requires a “payload” of 1536 FC frames. Additionally, an ADVB header frame is added, making a total of 1537 FC frames. Idle characters are required between FC frames because they are used for synchronization between transmitters and receivers.

Applications

Although ARINC 818 was developed specifically for avionics applications, the protocol is already being used in sensor fusion applications where multiple sensor outputs are multiplexed onto a single high-speed link. Features added in ARINC 818-2 facilitate using ARINC 818 as a sensor interface.

The ARINC 818 specification does not mandate which physical layer is to be used and implementations are done using both copper and fiber. Although the majority of implementation use fiber, low-speed implementations of ARINC 818 (1.0625Gbp to 6.375 Gbit/s) sometimes use copper (twinax or TSP or coax). The most commonly, either 850 nm MM fiber (<500m) or 1310 nm SM fiber (up to 10 km) is used. ARINC 818 lends itself to applications that require few conductors (slip rings, turrets), low weight (aerospace), EMI resistance, or long-distance transmission (aerospace, ships).

Flexibility vs. Interoperability

ARINC 818 is flexible and can accommodate many types of video and data applications. It is the intention of the standard that all implementation be accompanied by a small interface control document (ICD) that defines key parameters of the header such as: link speed, video resolution, color scheme, size of ancillary data, pixel format, timing classification, or bit-packing schemes. Interoperability is only guaranteed among equipment built to the same ICD.

Implementation considerations

ARINC 818 uses a FC physical layer that can be constructed from any FC compatible 8b/10b SerDes, which are common in large FPGAs.

ARINC 818 transmitters must assemble valid FC frames, including starting and ending ordered sets, headers, and CRC. This can easily be done with VHDL state machines, and many PLD SerDes include built in CRC calculations.

The flexibility of ARINC 818 allows for receiver implementations using either full image buffers or just display-line buffers. For either, synchronization issues must be considered at the pixel, line, and frame level.

Line buffer or FIFO-based receivers will require that the transmitter adhere to strict line timing requirements of the display. Since the display horizontal scanning must be precise, the arrival time of lines will also need to be precise. ARINC 818 intends that timing parameters such as these be captured in an ICD specific to the video system.

The authors of ARINC 818 built upon many years of combined experience of using FC to transport different video formats, and key implementation details are included in the specification, including examples of common analog formats.

ARINC 818-2 updates

ARINC 818-2, ratified in December 2013, adds features to accommodate higher link rates, support for compression and encryption, networking, and sophisticated display schemes, such as channel bonding used on large area displays (LADs).

Link rates: At the time the original ARINC 818 specification was ratified, the fiber-channel protocol supported link rates up to 8.5 gigabits per second (Gb/s). ARINC 818-2 added rates of 5.0, 6.375 (FC 6x), 12.75 (FC 12x), 14.025 (FC 16x), 21.0375 (FC 24x), and 28.05 (FC 32x) Gb/s. The 6x, 12x, and 24x speeds were added to accommodate the use of high-speed, bi-directional coax with power as a physical medium. The specification also provides for non-standard link rates for bi-directional return path for applications such as camera control where high speed video links are not required.

Compression and Encryption: ARINC 818 was originally envisioned as carrying only uncompressed video and audio. Applications such as high-resolution sensors, UAV/UAS with bandwidth limited downlinks, and data only applications drove the need to compress and/or encrypt a link. Sticking to a philosophy of maximum flexibility, the ARINC 818-2 calls for the ICD to specify implementation details for compression and encryption. The ARINC 818 protocol does not provide a means for compression and encryption, it simply provides flags to indicate that payload is compressed or encrypted.

Switching: ARINC 818 was designed as a point-to-point protocol. Since many of the newer implementations of the ARINC 818 have multiple displays and or many channels of ARINC 818 (10 or more), switching has become more important. The new specification requires that active switching can only occur between frames. In effect, to prevent broken video frames, the switch must wait until the vertical blanking. Again, the ICD controls the implementation details.

Field Sequential Color: A video format code was added to support field sequential color. The color field-sequential mode will typically send each color component in a separate container.

Channel Bonding: To overcome link bandwidth limitations of FPGAs, ARINC 818-2 supports multiple links in parallel. The video frame is broken into smaller segments and transmitted on two or more links. Each link must transmit a complete ADVB frame with header, and the ICD addresses latency and skew between the links.

Data-only Links: ARINC 818-2 provides for data-only links, typically used in command-and-control channels, such as those needed for bi-directional camera interfaces. These may employ a standard link rate or a non-standard rate specified by the ICD.

Regions of Interest: The ARINC 818-2 protocol provides a means for defining partial images, tiling, and region-of-interest that are important for high-speed sensors and stereo displays.

ARINC 818-3 updates

See also

Related Research Articles

<span class="mw-page-title-main">Asynchronous Transfer Mode</span> Digital telecommunications protocol for voice, video, and data

Asynchronous Transfer Mode (ATM) is a telecommunications standard defined by the American National Standards Institute and ITU-T for digital transmission of multiple types of traffic. ATM was developed to meet the needs of the Broadband Integrated Services Digital Network as defined in the late 1980s, and designed to integrate telecommunication networks. It can handle both traditional high-throughput data traffic and real-time, low-latency content such as telephony (voice) and video. ATM provides functionality that uses features of circuit switching and packet switching networks by using asynchronous time-division multiplexing. ATM was seen in the 1990s as a competitor to Ethernet and networks carrying IP traffic as it was faster and was designed with quality-of-service in mind, but it fell out of favor once Ethernet reached speeds of 1 gigabits per second.

<span class="mw-page-title-main">Synchronous optical networking</span> Standardized protocol

Synchronous Optical Networking (SONET) and Synchronous Digital Hierarchy (SDH) are standardized protocols that transfer multiple digital bit streams synchronously over optical fiber using lasers or highly coherent light from light-emitting diodes (LEDs). At low transmission rates data can also be transferred via an electrical interface. The method was developed to replace the plesiochronous digital hierarchy (PDH) system for transporting large amounts of telephone calls and data traffic over the same fiber without the problems of synchronization.

A frame is a digital data transmission unit in computer networking and telecommunication. In packet switched systems, a frame is a simple container for a single network packet. In other telecommunications systems, a frame is a repeating structure supporting time-division multiplexing.

<span class="mw-page-title-main">Serial communication</span> Type of data transfer

In telecommunication and data transmission, serial communication is the process of sending data one bit at a time, sequentially, over a communication channel or computer bus. This is in contrast to parallel communication, where several bits are sent as a whole, on a link with several parallel channels.

A controller area network is a vehicle bus standard designed to allow microcontrollers and devices to communicate with each other. It is a message-based protocol, designed originally for multiplex electrical wiring within automobiles to save on copper, but it can also be used in many other contexts. For each device, the data in a frame is transmitted serially but in such a way that if more than one device transmits at the same time, the highest priority device can continue while the others back off. Frames are received by all devices, including by the transmitting device.

Throughput of a network can be measured using various tools available on different platforms. This page explains the theory behind what these tools set out to measure and the issues regarding these measurements.

Aeronautical Radio, Incorporated (ARINC), established in 1929, was a major provider of transport communications and systems engineering solutions for eight industries: aviation, airports, defense, government, healthcare, networks, security, and transportation. ARINC had installed computer data networks in police cars and railroad cars and also maintains the standards for line-replaceable units.

<span class="mw-page-title-main">RapidIO</span> High-speed interconnect technology

The RapidIO architecture is a high-performance packet-switched electrical connection technology. It supports messaging, read/write and cache coherency semantics. Based on industry-standard electrical specifications such as those for Ethernet, RapidIO can be used as a chip-to-chip, board-to-board, and chassis-to-chassis interconnect.

Generic Framing Procedure (GFP) is a multiplexing technique defined by ITU-T G.7041. This allows mapping of variable length, higher-layer client signals over a circuit switched transport network like OTN, SDH/SONET or PDH. The client signals can be protocol data unit (PDU) oriented or can be block-code oriented.

Avionics Full-Duplex Switched Ethernet (AFDX), also ARINC 664, is a data network, patented by international aircraft manufacturer Airbus, for safety-critical applications that utilizes dedicated bandwidth while providing deterministic quality of service (QoS). AFDX is a worldwide registered trademark by Airbus. The AFDX data network is based on Ethernet technology using commercial off-the-shelf (COTS) components. The AFDX data network is a specific implementation of ARINC Specification 664 Part 7, a profiled version of an IEEE 802.3 network per parts 1 & 2, which defines how commercial off-the-shelf networking components will be used for future generation Aircraft Data Networks (ADN). The six primary aspects of an AFDX data network include full duplex, redundancy, determinism, high speed performance, switched and profiled network.

ARINC 429, the "Mark 33 Digital Information Transfer System (DITS)," is the ARINC technical standard for the predominant avionics data bus used on most higher-end commercial and transport aircraft. It defines the physical and electrical interfaces of a two-wire data bus and a data protocol to support an aircraft's avionics local area network.

In computer networking, jumbo frames are Ethernet frames with more than 1500 bytes of payload, the limit set by the IEEE 802.3 standard. The payload limit for jumbo frames is variable: while 9000 bytes is the most commonly used limit, smaller and larger limits exist. Many Gigabit Ethernet switches and Gigabit Ethernet network interface controllers and some Fast Ethernet switches and Fast Ethernet network interface cards can support jumbo frames.

The Simple Sensor Interface (SSI) protocol is a simple communications protocol designed for data transfer between computers or user terminals and smart sensors.

In computer networking, an Ethernet frame is a data link layer protocol data unit and uses the underlying Ethernet physical layer transport mechanisms. In other words, a data unit on an Ethernet link transports an Ethernet frame as its payload.

In computer networking, a Fibre Channel frame is the frame of the Fibre Channel protocol. The basic building blocks of an FC connection are the frames. They contain the information to be transmitted (payload), the address of the source and destination ports and link control information. Frames are broadly categorized as

In mobile-telephone technology, the UniPro protocol stack follows the architecture of the classical OSI Reference Model. In UniPro, the OSI Physical Layer is split into two sublayers: Layer 1 and Layer 1.5 which abstracts from differences between alternative Layer 1 technologies. The actual physical layer is a separate specification as the various PHY options are reused in other MIPI Alliance specifications.

<span class="mw-page-title-main">CANaerospace</span>

CANaerospace is a higher layer protocol based on Controller Area Network (CAN) which has been developed by Stock Flight Systems in 1998 for aeronautical applications.

Generic Stream Encapsulation, or GSE for short, is a Data link layer protocol defined by DVB. GSE provides means to carry packet oriented protocols such as IP on top of uni-directional physical layers such as DVB-S2, DVB-T2 and DVB-C2.

CAN FD is a data-communication protocol used for broadcasting sensor data and control information on 2 wire interconnections between different parts of electronic instrumentation and control system. This protocol is used in modern high performance vehicles.

References