The heating value (or energy value or calorific value) of a substance, usually a fuel or food (see food energy), is the amount of heat released during the combustion of a specified amount of it.
The calorific value is the total energy released as heat when a substance undergoes complete combustion with oxygen under standard conditions. The chemical reaction is typically a hydrocarbon or other organic molecule reacting with oxygen to form carbon dioxide and water and release heat. It may be expressed with the quantities:
There are two kinds of enthalpy of combustion, called high(er) and low(er) heat(ing) value, depending on how much the products are allowed to cool and whether compounds like H
2O are allowed to condense. The high heat values are conventionally measured with a bomb calorimeter. Low heat values are calculated from high heat value test data. They may also be calculated as the difference between the heat of formation ΔH⦵
f of the products and reactants (though this approach is somewhat artificial since most heats of formation are typically calculated from measured heats of combustion).. [1]
For a fuel of composition CcHhOoNn, the (higher) heat of combustion is 419 kJ/mol × (c + 0.3 h − 0.5 o) usually to a good approximation (±3%), [2] [3] though it gives poor results for some compounds such as (gaseous) formaldehyde and carbon monoxide, and can be significantly off if o + n > c, such as for glycerine dinitrate, C3H6O7N2. [4]
By convention, the (higher) heat of combustion is defined to be the heat released for the complete combustion of a compound in its standard state to form stable products in their standard states: hydrogen is converted to water (in its liquid state), carbon is converted to carbon dioxide gas, and nitrogen is converted to nitrogen gas. That is, the heat of combustion, ΔH°comb, is the heat of reaction of the following process:
Chlorine and sulfur are not quite standardized; they are usually assumed to convert to hydrogen chloride gas and SO
2 or SO
3 gas, respectively, or to dilute aqueous hydrochloric and sulfuric acids, respectively, when the combustion is conducted in a bomb calorimeter containing some quantity of water. [5] [6]
Zwolinski and Wilhoit defined, in 1972, "gross" and "net" values for heats of combustion. In the gross definition the products are the most stable compounds, e.g. H
2O(l), Br
2(l), I
2(s) and H
2SO
4(l). In the net definition the products are the gases produced when the compound is burned in an open flame, e.g. H
2O(g), Br
2(g), I
2(g) and SO
2(g). In both definitions the products for C, F, Cl and N are CO
2(g), HF(g), Cl
2(g) and N
2(g), respectively. [7]
Dulong's Formula
The heating value of a fuel can be calculated with the results of ultimate analysis of fuel. From analysis, percentages of the combustibles in the fuel (carbon, hydrogen, sulfur) are known. Since the heat of combustion of these elements is known, the heating value can be calculated using Dulong's Formula:
HHV [kJ/g]= 33.87mC + 122.3(mH - mO ÷ 8) + 9.4mS
where mC, mH, mO, mN, and mS are the contents of carbon, hydrogen, oxygen, nitrogen, and sulfur on any (wet, dry or ash free) basis, respectively. [8]
The higher heating value (HHV; gross energy, upper heating value, gross calorific valueGCV, or higher calorific value; HCV) indicates the upper limit of the available thermal energy produced by a complete combustion of fuel. It is measured as a unit of energy per unit mass or volume of substance. The HHV is determined by bringing all the products of combustion back to the original pre-combustion temperature, including condensing any vapor produced. Such measurements often use a standard temperature of 25 °C (77 °F; 298 K)[ citation needed ]. This is the same as the thermodynamic heat of combustion since the enthalpy change for the reaction assumes a common temperature of the compounds before and after combustion, in which case the water produced by combustion is condensed to a liquid. The higher heating value takes into account the latent heat of vaporization of water in the combustion products, and is useful in calculating heating values for fuels where condensation of the reaction products is practical (e.g., in a gas-fired boiler used for space heat). In other words, HHV assumes all the water component is in liquid state at the end of combustion (in product of combustion) and that heat delivered at temperatures below 150 °C (302 °F) can be put to use.
The lower heating value (LHV; net calorific value; NCV, or lower calorific value; LCV) is another measure of available thermal energy produced by a combustion of fuel, measured as a unit of energy per unit mass or volume of substance. In contrast to the HHV, the LHV considers energy losses such as the energy used to vaporize water - although its exact definition is not uniformly agreed upon. One definition is simply to subtract the heat of vaporization of the water from the higher heating value. This treats any H2O formed as a vapor that is released as a waste. The energy required to vaporize the water is therefore lost.
LHV calculations assume that the water component of a combustion process is in vapor state at the end of combustion, as opposed to the higher heating value (HHV) (a.k.a. gross calorific value or gross CV) which assumes that all of the water in a combustion process is in a liquid state after a combustion process.
Another definition of the LHV is the amount of heat released when the products are cooled to 150 °C (302 °F). This means that the latent heat of vaporization of water and other reaction products is not recovered. It is useful in comparing fuels where condensation of the combustion products is impractical, or heat at a temperature below 150 °C (302 °F) cannot be put to use.
One definition of lower heating value, adopted by the American Petroleum Institute (API), uses a reference temperature of 60 °F (15+5⁄9 °C).
Another definition, used by Gas Processors Suppliers Association (GPSA) and originally used by API (data collected for API research project 44), is the enthalpy of all combustion products minus the enthalpy of the fuel at the reference temperature (API research project 44 used 25 °C. GPSA currently uses 60 °F), minus the enthalpy of the stoichiometric oxygen (O2) at the reference temperature, minus the heat of vaporization of the vapor content of the combustion products.
The definition in which the combustion products are all returned to the reference temperature is more easily calculated from the higher heating value than when using other definitions and will in fact give a slightly different answer.
Gross heating value accounts for water in the exhaust leaving as vapor, as does LHV, but gross heating value also includes liquid water in the fuel prior to combustion. This value is important for fuels like wood or coal, which will usually contain some amount of water prior to burning.
The higher heating value is experimentally determined in a bomb calorimeter. The combustion of a stoichiometric mixture of fuel and oxidizer (e.g. two moles of hydrogen and one mole of oxygen) in a steel container at 25 °C (77 °F) is initiated by an ignition device and the reactions allowed to complete. When hydrogen and oxygen react during combustion, water vapor is produced. The vessel and its contents are then cooled to the original 25 °C and the higher heating value is determined as the heat released between identical initial and final temperatures.
When the lower heating value (LHV) is determined, cooling is stopped at 150 °C and the reaction heat is only partially recovered. The limit of 150 °C is based on acid gas dew-point.
Note: Higher heating value (HHV) is calculated with the product of water being in liquid form while lower heating value (LHV) is calculated with the product of water being in vapor form.
The difference between the two heating values depends on the chemical composition of the fuel. In the case of pure carbon or carbon monoxide, the two heating values are almost identical, the difference being the sensible heat content of carbon dioxide between 150 °C and 25 °C (sensible heat exchange causes a change of temperature, while latent heat is added or subtracted for phase transitions at constant temperature. Examples: heat of vaporization or heat of fusion). For hydrogen, the difference is much more significant as it includes the sensible heat of water vapor between 150 °C and 100 °C, the latent heat of condensation at 100 °C, and the sensible heat of the condensed water between 100 °C and 25 °C. In all, the higher heating value of hydrogen is 18.2% above its lower heating value (142 MJ/kg vs. 120 MJ/kg). For hydrocarbons, the difference depends on the hydrogen content of the fuel. For gasoline and diesel the higher heating value exceeds the lower heating value by about 10% and 7%, respectively, and for natural gas about 11%.
A common method of relating HHV to LHV is:
where Hv is the heat of vaporization of water, nH
2O,out is the number of moles of water vaporized and nfuel,in is the number of moles of fuel combusted. [9]
Engine manufacturers typically rate their engines fuel consumption by the lower heating values since the exhaust is never condensed in the engine, and doing this allows them to publish more attractive numbers than are used in conventional power plant terms. The conventional power industry had used HHV (high heat value) exclusively for decades, even though virtually all of these plants did not condense exhaust either. American consumers should be aware that the corresponding fuel-consumption figure based on the higher heating value will be somewhat higher.
The difference between HHV and LHV definitions causes endless confusion when quoters do not bother to state the convention being used. [10] since there is typically a 10% difference between the two methods for a power plant burning natural gas. For simply benchmarking part of a reaction the LHV may be appropriate, but HHV should be used for overall energy efficiency calculations if only to avoid confusion, and in any case, the value or convention should be clearly stated.
Both HHV and LHV can be expressed in terms of AR (all moisture counted), MF and MAF (only water from combustion of hydrogen). AR, MF, and MAF are commonly used for indicating the heating values of coal:
Fuel | HHV | LHV | ||
---|---|---|---|---|
MJ/kg | BTU/lb | kJ/mol | MJ/kg | |
Hydrogen | 141.80 | 61,000 | 286 | 119.96 |
Methane | 55.50 | 23,900 | 890 | 50.00 |
Ethane | 51.90 | 22,400 | 1,560 | 47.62 |
Propane | 50.35 | 21,700 | 2,220 | 46.35 |
Butane | 49.50 | 20,900 | 2,877 | 45.75 |
Pentane | 48.60 | 21,876 | 3,509 | 45.35 |
Paraffin wax | 46.00 | 19,900 | 41.50 | |
Kerosene | 46.20 | 19,862 | 43.00 | |
Jet kerosene [12] | 46.42 | - | 44.1 | |
Diesel | 44.80 | 19,300 | 43.4 | |
Coal (anthracite) | 32.50 | 14,000 | ||
Coal (lignite - USA) | 15.00 | 6,500 | ||
Wood (MAF) | 21.70 | 8,700 | ||
Wood fuel | 16.0 | 6,400 | 17.0 | |
Peat (dry) | 15.00 | 6,500 | ||
Peat (damp) | 6.00 | 2,500 |
Fuel | MJ/kg | BTU/lb | kJ/mol |
---|---|---|---|
Methanol | 22.7 | 9,800 | 726 |
Ethanol | 29.7 | 12,800 | 1,367 |
1-Propanol | 33.6 | 14,500 | 2,020 |
Acetylene | 49.9 | 21,500 | 1,300 |
Benzene | 41.8 | 18,000 | 3,268 |
Ammonia | 22.5 | 9,690 | 382.6 |
Hydrazine | 19.4 | 8,370 | 622.0 |
Hexamine | 30.0 | 12,900 | 4,200.0 |
Carbon | 32.8 | 14,100 | 393.5 |
Fuel | MJ/kg | MJ/L | BTU/lb | kJ/mol |
---|---|---|---|---|
Alkanes | ||||
Methane | 50.009 | 6.9 | 21,504 | 802.34 |
Ethane | 47.794 | — | 20,551 | 1,437.2 |
Propane | 46.357 | 25.3 | 19,934 | 2,044.2 |
Butane | 45.752 | — | 19,673 | 2,659.3 |
Pentane | 45.357 | 28.39 | 21,706 | 3,272.6 |
Hexane | 44.752 | 29.30 | 19,504 | 3,856.7 |
Heptane | 44.566 | 30.48 | 19,163 | 4,465.8 |
Octane | 44.427 | — | 19,104 | 5,074.9 |
Nonane | 44.311 | 31.82 | 19,054 | 5,683.3 |
Decane | 44.240 | 33.29 | 19,023 | 6,294.5 |
Undecane | 44.194 | 32.70 | 19,003 | 6,908.0 |
Dodecane | 44.147 | 33.11 | 18,983 | 7,519.6 |
Isoparaffins | ||||
Isobutane | 45.613 | — | 19,614 | 2,651.0 |
Isopentane | 45.241 | 27.87 | 19,454 | 3,264.1 |
2-Methylpentane | 44.682 | 29.18 | 19,213 | 3,850.7 |
2,3-Dimethylbutane | 44.659 | 29.56 | 19,203 | 3,848.7 |
2,3-Dimethylpentane | 44.496 | 30.92 | 19,133 | 4,458.5 |
2,2,4-Trimethylpentane | 44.310 | 30.49 | 19,053 | 5,061.5 |
Naphthenes | ||||
Cyclopentane | 44.636 | 33.52 | 19,193 | 3,129.0 |
Methylcyclopentane | 44.636? | 33.43? | 19,193? | 3,756.6? |
Cyclohexane | 43.450 | 33.85 | 18,684 | 3,656.8 |
Methylcyclohexane | 43.380 | 33.40 | 18,653 | 4,259.5 |
Monoolefins | ||||
Ethylene | 47.195 | — | — | — |
Propylene | 45.799 | — | — | — |
1-Butene | 45.334 | — | — | — |
cis-2-Butene | 45.194 | — | — | — |
trans-2-Butene | 45.124 | — | — | — |
Isobutene | 45.055 | — | — | — |
1-Pentene | 45.031 | — | — | — |
2-Methyl-1-pentene | 44.799 | — | — | — |
1-Hexene | 44.426 | — | — | — |
Diolefins | ||||
1,3-Butadiene | 44.613 | — | — | — |
Isoprene | 44.078 | - | — | — |
Nitrous derived | ||||
Nitromethane | 10.513 | — | — | — |
Nitropropane | 20.693 | — | — | — |
Acetylenes | ||||
Acetylene | 48.241 | — | — | — |
Methylacetylene | 46.194 | — | — | — |
1-Butyne | 45.590 | — | — | — |
1-Pentyne | 45.217 | — | — | — |
Aromatics | ||||
Benzene | 40.170 | — | — | — |
Toluene | 40.589 | — | — | — |
o-Xylene | 40.961 | — | — | — |
m-Xylene | 40.961 | — | — | — |
p-Xylene | 40.798 | — | — | — |
Ethylbenzene | 40.938 | — | — | — |
1,2,4-Trimethylbenzene | 40.984 | — | — | — |
n-Propylbenzene | 41.193 | — | — | — |
Cumene | 41.217 | — | — | — |
Alcohols | ||||
Methanol | 19.930 | 15.78 | 8,570 | 638.6 |
Ethanol | 26.70 | 22.77 | 12,412 | 1,230.1 |
1-Propanol | 30.680 | 24.65 | 13,192 | 1,843.9 |
Isopropanol | 30.447 | 23.93 | 13,092 | 1,829.9 |
n-Butanol | 33.075 | 26.79 | 14,222 | 2,501.6 |
Isobutanol | 32.959 | 26.43 | 14,172 | 2,442.9 |
tert-Butanol | 32.587 | 25.45 | 14,012 | 2,415.3 |
n-Pentanol | 34.727 | 28.28 | 14,933 | 3,061.2 |
Isoamyl alcohol | 31.416? | 35.64? | 13,509? | 2,769.3? |
Ethers | ||||
Methoxymethane | 28.703 | — | 12,342 | 1,322.3 |
Ethoxyethane | 33.867 | 24.16 | 14,563 | 2,510.2 |
Propoxypropane | 36.355 | 26.76 | 15,633 | 3,568.0 |
Butoxybutane | 37.798 | 28.88 | 16,253 | 4,922.4 |
Aldehydes and ketones | ||||
Formaldehyde | 17.259 | — | — | 570.78 [13] |
Acetaldehyde | 24.156 | — | — | — |
Propionaldehyde | 28.889 | — | — | — |
Butyraldehyde | 31.610 | — | — | — |
Acetone | 28.548 | 22.62 | — | — |
Other species | ||||
Carbon (graphite) | 32.808 | — | — | — |
Hydrogen | 120.971 | 1.8 | 52,017 | 244 |
Carbon monoxide | 10.112 | — | 4,348 | 283.24 |
Ammonia | 18.646 | — | 8,018 | 317.56 |
Sulfur (solid) | 9.163 | — | 3,940 | 293.82 |
The International Energy Agency reports the following typical higher heating values per Standard cubic metre of gas: [14]
The lower heating value of natural gas is normally about 90% of its higher heating value. This table is in Standard cubic metres (1 atm, 15 °C), to convert to values per Normal cubic metre (1 atm, 0 °C), multiply above table by 1.0549.
Combustion, or burning, is a high-temperature exothermic redox chemical reaction between a fuel and an oxidant, usually atmospheric oxygen, that produces oxidized, often gaseous products, in a mixture termed as smoke. Combustion does not always result in fire, because a flame is only visible when substances undergoing combustion vaporize, but when it does, a flame is a characteristic indicator of the reaction. While activation energy must be supplied to initiate combustion, the heat from a flame may provide enough energy to make the reaction self-sustaining. The study of combustion is known as combustion science.
Propane is a three-carbon alkane with the molecular formula C3H8. It is a gas at standard temperature and pressure, but compressible to a transportable liquid. A by-product of natural gas processing and petroleum refining, it is often a constituent of liquefied petroleum gas (LPG), which is commonly used as a fuel in domestic and industrial applications and in low-emissions public transportation; other constituents of LPG may include propylene, butane, butylene, butadiene, and isobutylene. Discovered in 1857 by the French chemist Marcellin Berthelot, it became commercially available in the US by 1911. Propane has lower volumetric energy density than gasoline or coal, but has higher gravimetric energy density than them and burns more cleanly.
In thermodynamics, the enthalpy of vaporization, also known as the (latent) heat of vaporization or heat of evaporation, is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas. The enthalpy of vaporization is a function of the pressure and temperature at which the transformation takes place.
Liquid hydrogen (H2(l)) is the liquid state of the element hydrogen. Hydrogen is found naturally in the molecular H2 form.
Solid fuel refers to various forms of solid material that can be burnt to release energy, providing heat and light through the process of combustion. Solid fuels can be contrasted with liquid fuels and gaseous fuels. Common examples of solid fuels include wood, charcoal, peat, coal, hexamine fuel tablets, dry dung, wood pellets, corn, wheat, rice, rye, and other grains. Solid fuels are extensively used in rocketry as solid propellants. Solid fuels have been used throughout human history to create fire and solid fuel is still in widespread use throughout the world in the present day.
A combined cycle power plant is an assembly of heat engines that work in tandem from the same source of heat, converting it into mechanical energy. On land, when used to make electricity the most common type is called a combined cycle gas turbine (CCGT) plant, which is a kind of gas-fired power plant. The same principle is also used for marine propulsion, where it is called a combined gas and steam (COGAS) plant. Combining two or more thermodynamic cycles improves overall efficiency, which reduces fuel costs.
Fuel gas is one of a number of fuels that under ordinary conditions are gaseous. Most fuel gases are composed of hydrocarbons, hydrogen, carbon monoxide, or mixtures thereof. Such gases are sources of energy that can be readily transmitted and distributed through pipes.
In physics, energy density is the amount of energy stored in a given system or region of space per unit volume. Often only the useful or extractable energy is measured. It is sometimes confused with stored energy per unit mass, which is called specific energy or gravimetric energy density.
The Wobbe index (WI) or Wobbe number is an indicator of the interchangeability of fuel gases such as natural gas, liquefied petroleum gas (LPG), and town gas and is frequently defined in the specifications of gas supply and transport utilities.
Micro combined heat and power, micro-CHP, μCHP or mCHP is an extension of the idea of cogeneration to the single/multi family home or small office building in the range of up to 50 kW. Usual technologies for the production of heat and power in one common process are e.g. internal combustion engines, micro gas turbines, stirling engines or fuel cells.
A gas engine is an internal combustion engine that runs on a fuel gas, such as coal gas, producer gas, biogas, landfill gas, natural gas or hydrogen. In the United Kingdom and British English-speaking countries, the term is unambiguous. In the United States, due to the widespread use of "gas" as an abbreviation for gasoline (petrol), such an engine is sometimes called by a clarifying term, such as gaseous-fueled engine or natural gas engine.
An absorption refrigerator is a refrigerator that uses a heat source to provide the energy needed to drive the cooling process. Solar energy, burning a fossil fuel, waste heat from factories, and district heating systems are examples of convenient heat sources that can be used. An absorption refrigerator uses two coolants: the first coolant performs evaporative cooling and then is absorbed into the second coolant; heat is needed to reset the two coolants to their initial states. Absorption refrigerators are commonly used in recreational vehicles (RVs), campers, and caravans because the heat required to power them can be provided by a propane fuel burner, by a low-voltage DC electric heater or by a mains-powered electric heater. Absorption refrigerators can also be used to air-condition buildings using the waste heat from a gas turbine or water heater in the building. Using waste heat from a gas turbine makes the turbine very efficient because it first produces electricity, then hot water, and finally, air-conditioning—trigeneration.
In thermodynamics, the thermal efficiency is a dimensionless performance measure of a device that uses thermal energy, such as an internal combustion engine, steam turbine, steam engine, boiler, furnace, refrigerator, ACs etc.
Water gas is a kind of fuel gas, a mixture of carbon monoxide and hydrogen. It is produced by "alternately hot blowing a fuel layer [coke] with air and gasifying it with steam". The caloric yield of the fuel produced by this method is about 10% of the yield from a modern syngas plant. The coke needed to produce water gas also costs significantly more than the precursors for syngas, making water gas technology an even less attractive business proposition.
A turboexpander, also referred to as a turbo-expander or an expansion turbine, is a centrifugal or axial-flow turbine, through which a high-pressure gas is expanded to produce work that is often used to drive a compressor or generator.
Energy conversion efficiency (η) is the ratio between the useful output of an energy conversion machine and the input, in energy terms. The input, as well as the useful output may be chemical, electric power, mechanical work, light (radiation), or heat. The resulting value, η (eta), ranges between 0 and 1.
Smokeless fuel is a type of solid fuel which either does not emit visible smoke or emits minimal amounts during combustion. These types of fuel find use where the use of fuels which produce smoke, such as coal and unseasoned or wet wood, is prohibited.
The Glossary of fuel cell terms lists the definitions of many terms used within the fuel cell industry. The terms in this fuel cell glossary may be used by fuel cell industry associations, in education material and fuel cell codes and standards to name but a few.
Flue gas condensation is a process, where flue gas is cooled below its water dew point and the heat released by the resulting condensation of water is recovered as low temperature heat.
Proton exchange membrane(PEM) electrolysis is the electrolysis of water in a cell equipped with a solid polymer electrolyte (SPE) that is responsible for the conduction of protons, separation of product gases, and electrical insulation of the electrodes. The PEM electrolyzer was introduced to overcome the issues of partial load, low current density, and low pressure operation currently plaguing the alkaline electrolyzer. It involves a proton-exchange membrane.