Resonant inductive coupling or magnetic phase synchronous coupling [4] [5] is a phenomenon with inductive coupling in which the coupling becomes stronger when the "secondary" (load-bearing) side of the loosely coupled coil resonates. [5] A resonant transformer of this type is often used in analog circuitry as a bandpass filter. Resonant inductive coupling is also used in wireless power systems for portable computers, phones, and vehicles.
This section may lend undue weight to certain ideas, incidents, or controversies. Please help to create a more balanced presentation. Discuss and resolve this issue before removing this message. (February 2022) |
Various resonant coupling systems in use or are under development for short range (up to 2 meters) [6] wireless electricity systems to power laptops, tablets, smartphones, robot vacuums, implanted medical devices, and vehicles like electric cars, SCMaglev trains [7] and automated guided vehicles. [8] Specific technologies include:
Other applications include:
The Tesla coil is a resonant transformer circuit used to generate very high voltages, and is able to provide much higher current than high voltage electrostatic machines such as the Van de Graaff generator. [10] However, this type of system radiates most of its energy into empty space, unlike modern wireless power systems which waste very little energy.
Resonant transformers are widely used in radio circuits as bandpass filters, and in switching power supplies.
This section may lend undue weight to certain ideas, incidents, or controversies. Please help to create a more balanced presentation. Discuss and resolve this issue before removing this message. (February 2022) |
In 1894 Nikola Tesla used resonant inductive coupling, also known as "electro-dynamic induction" to wirelessly light up phosphorescent and incandescent lamps at the 35 South Fifth Avenue laboratory, and later at the 46 E. Houston Street laboratory in New York City. [11] [12] [13] In 1897 he patented a device [14] called the high-voltage, resonant transformer or "Tesla coil." Transferring electrical energy from the primary coil to the secondary coil by resonant induction, a Tesla coil is capable of producing very high voltages at high frequency. The improved design allowed for the safe production and utilization of high-potential electrical currents, "without serious liability of the destruction of the apparatus itself and danger to persons approaching or handling it."
In the early 1960s resonant inductive wireless energy transfer was used successfully in implantable medical devices [15] including such devices as pacemakers and artificial hearts. While the early systems used a resonant receiver coil, later systems [16] implemented resonant transmitter coils as well. These medical devices are designed for high efficiency using low power electronics while efficiently accommodating some misalignment and dynamic twisting of the coils. The separation between the coils in implantable applications is commonly less than 20 cm. Today resonant inductive energy transfer is regularly used for providing electric power in many commercially available medical implantable devices. [17]
Wireless electric energy transfer for experimentally powering electric automobiles and buses is a higher power application (>10 kW) of resonant inductive energy transfer. High power levels are required for rapid recharging and high energy transfer efficiency is required both for operational economy and to avoid negative environmental impact of the system. An experimental electrified roadway test track built circa 1990 achieved just above 60% energy efficiency while recharging the battery of a prototype bus at a specially equipped bus stop. [18] [19] The bus could be outfitted with a retractable receiving coil for greater coil clearance when moving. The gap between the transmit and receive coils was designed to be less than 10 cm when powered. In addition to buses the use of wireless transfer has been investigated for recharging electric automobiles in parking spots and garages as well.
Some of these wireless resonant inductive devices operate at low milliwatt power levels and are battery powered. Others operate at higher kilowatt power levels. Current implantable medical and road electrification device designs achieve more than 75% transfer efficiency at an operating distance between the transmit and receive coils of less than 10 cm.[ citation needed ]
In 1993, Professor John Boys and Professor Grant Covic, of the University of Auckland in New Zealand, developed systems to transfer large amounts of energy across small air gaps. [4] [5] [20] It was putting into practical use as the moving crane and the AGV non-contact power supply in Japan. [8] In 1998, RFID tags were patented that were powered in this way. [21]
In November 2006, Marin Soljačić and other researchers at the Massachusetts Institute of Technology applied this near field behavior to wireless power transmission, based on strongly-coupled resonators. [22] [23] [24] In a theoretical analysis, [25] they demonstrate that, by designing electromagnetic resonators that suffer minimal loss due to radiation and absorption and have a near field with mid-range extent (namely a few times the resonator size), mid-range efficient wireless energy-transfer is possible. The reason is that, if two such resonant circuits tuned to the same frequency are within a fraction of a wavelength, their near fields (consisting of 'evanescent waves') couple by means of evanescent wave coupling. Oscillating waves develop between the inductors, which can allow the energy to transfer from one object to the other within times much shorter than all loss times, which were designed to be long, and thus with the maximum possible energy-transfer efficiency. Since the resonant wavelength is much larger than the resonators, the field can circumvent extraneous objects in the vicinity and thus this mid-range energy-transfer scheme does not require line-of-sight. By utilizing in particular the magnetic field to achieve the coupling, this method can be safe, since magnetic fields interact weakly with living organisms.
Apple Inc. applied for a patent on the technology in 2010, after WiPower did so in 2008. [26]
In the past, the power source used on the JR Tokai SCMaglev car was generating with a gas turbine generator. In 2011, they succeeded in powering while driving (CWD:charge while driving) across a large gap by the JR Tokai proprietary 9.8 kHz phase synchronization technology developed based on technology similar to AGV's wireless power scheme. And the Japanese Ministry of Land, Infrastructure and Transportation evaluated the technology as all the problems for practical use were cleared. [27] Construction of SCMaglev begin and commercial use will start in 2027. [28]
Non-resonant coupled inductors, such as typical transformers, work on the principle of a primary coil generating a magnetic field and a secondary coil subtending as much as possible of that field so that the power passing through the secondary is as close as possible to that of the primary. This requirement that the field be covered by the secondary results in very short range and usually requires a magnetic core. Over greater distances the non-resonant induction method is highly inefficient and wastes the vast majority of the energy in resistive losses of the primary coil.
Using resonance can help improve efficiency dramatically. If resonant coupling is used, the secondary coil is capacitive loaded so as to form a tuned LC circuit. If the primary coil is driven at the secondary side resonant frequency, it turns out that significant power may be transmitted between the coils over a range of a few times the coil diameters at reasonable efficiency. [29]
Compared to the costs associated with batteries, particularly non-rechargeable batteries, the costs of the batteries are hundreds of times higher. In situations where a source of power is available nearby, it can be a cheaper solution. [30] In addition, whereas batteries need periodic maintenance and replacement, resonant energy transfer can be used instead. Batteries additionally generate pollution during their construction and their disposal which is largely avoided.
Unlike mains-wired equipment, no direct electrical connection is needed and hence equipment can be sealed to minimize the possibility of electric shock.
Because the coupling is achieved using predominantly magnetic fields; the technology may be relatively safe. Safety standards and guidelines do exist in most countries for electromagnetic field exposures (e.g. ICNIRP [31] [32] ). Whether the system can meet the guidelines or the less stringent legal requirements depends on the delivered power and range from the transmitter. Maximum recommended B-field is a complicated function of frequency, the ICNIRP guidelines for example permit RMS fields of tens of microteslas below 100 kHz, falling with frequency to 200 nanoteslas in the VHF, and lower levels above 400 MHz, where body parts can sustain current loops comparable to a wavelength in diameter, and deep tissue energy absorption reaches a maximum.
Deployed systems already generate magnetic fields, for example induction cookers in the tens of kHz where high fields are permitted, and contactless smart card readers, where higher frequency is possible as the required energies are lower.
A study for the Swedish military found that 85 kHz systems for dynamic wireless power transfer for vehicles can cause electromagnetic interference at a radius of up to 300 kilometers. [33]
This section may lend undue weight to certain ideas, incidents, or controversies. Please help to create a more balanced presentation. Discuss and resolve this issue before removing this message. (February 2022) |
This process occurs in a resonant transformer, an electrical component which transformer consists of high Q coil wound on the same core with a capacitor connected across a coil to make a coupled LC circuit.
The most basic resonant inductive coupling consists of one drive coil on the primary side and one resonance circuit on the secondary side. [34] [5] [2] In this case, when the resonant state on the secondary side is observed from the primary side, two resonances as a pair are observed. [35] [5] One of them is called the antiresonant frequency (parallel resonant frequency 1), and the other is called the resonant frequency (serial resonant frequency 1'). [5] The short-circuit inductance and resonant capacitor of the secondary coil are combined into a resonant circuit. [36] [5] When the primary coil is driven with a resonant frequency (serial resonant frequency) of the secondary side, the phases of the magnetic fields of the primary coil and the secondary coil are synchronized. [5] As a result, the maximum voltage is generated on the secondary coil due to the increase of the mutual flux, and the copper loss of the primary coil is reduced, the heat generation is reduced, and the efficiency is relatively improved. [2] The resonant inductive coupling is the near field wireless transmission of electrical energy between magnetically coupled coils, which is part of a resonant circuit tuned to resonate at the same frequency as the driving frequency.
In the transformer, only part of the flux generated by current through the primary coil is coupled to the secondary coil and vice versa. The part that couples is called mutual flux and the part that does not couple is called leakage flux. [37] When the system is not in the resonance state, this leads to the open-circuit voltage appearing at the secondary being less than predicted by the turns ratio of the coils. The degree of coupling is captured by a parameter called coupling coefficient. The coupling coefficient, k, is defined as the ratio of transformer open-circuit voltage ratio to the ratio that would be obtained if all the flux coupled from one coil to the other. However, if it is not open circuit, the flux ratio will change. The value of k lies between 0 and ±1. Each coil inductance can be notionally divided into two parts in the proportions k:(1−k). These are respectively an inductance producing the mutual flux and an inductance producing the leakage flux.
Coupling coefficient is a function of the geometry of the system. It is fixed by the positional relationship between the two coils. The coupling coefficient does not change between when the system is in the resonance state and when it is not in the resonance state, or even if the system is in resonance state and a secondary voltage larger than the turns ratio is generated. However, in the resonance case, the flux ratio changes and the mutual flux increases.
Resonant systems are said to be tightly coupled, loosely coupled, critically coupled or overcoupled. Tight coupling is when the coupling coefficient is around 1 as with conventional iron-core transformers. Overcoupling is when the secondary coil is so close and the formation of mutual flux is hindered by the effect of antiresonance, and critical coupling is when the transfer in the passband is optimal. Loose coupling is when the coils are distant from each other, so that most of the flux misses the secondary. In Tesla coils around 0.2 is used, and at greater distances, for example for inductive wireless power transmission, it may be lower than 0.01.
Generally the voltage gain of non resonantly coupled coils is directly proportional to the square root of the ratio of secondary and primary inductances.
However, if in the state of resonant coupling, higher voltage is generated. The short-circuit inductance Lsc2 on the secondary side can be obtained by the following formula.
The short-circuit inductance Lsc2 and the resonance capacitor Cr on the secondary side resonate. The resonance frequency ω2 is as follows.
Assuming that the load resistance is Rl, the Q value of the secondary resonance circuit is as follows.
The voltage generated in the resonance capacitor Cr at the peak of the resonance frequency is proportional to the Q value. Therefore, the voltage gain Ar of the secondary coil with respect to the primary coil when the system is resonating,
In the case of the Type P-P, Q1 does not contribute to the voltage gain.
The WiTricity type magnetic resonance is characterized in that the resonant coils on the primary side and the resonant coils on the secondary side are paired. The primary resonant coil increases the primary driving coil current and increases the generated magnetic flux around the primary resonator. This is equivalent to driving the primary coil at high voltage. In the case of the type on the left figure, the general principle is that if a given oscillating amount of energy (for example a pulse or a series of pulses) is placed into a primary coil which is capacitively loaded, the coil will 'ring', and form an oscillating magnetic field.
Resonant transfer works by making a coil ring with an oscillating current. This generates an oscillating magnetic field. Because the coil is highly resonant, any energy placed in the coil dies away relatively slowly over very many cycles; but if a second coil is brought near it, the coil can pick up most of the energy before it is lost, even if it is some distance away. The fields used are predominantly non-radiative, near fields (sometimes called evanescent waves), as all hardware is kept well within the 1/4 wavelength distance they radiate little energy from the transmitter to infinity.
The energy will transfer back and forth between the magnetic field in the inductor and the electric field across the capacitor at the resonant frequency. This oscillation will die away at a rate determined by the gain-bandwidth (Q factor), mainly due to resistive and radiative losses. However, provided the secondary coil cuts enough of the field that it absorbs more energy than is lost in each cycle of the primary, then most of the energy can still be transferred.
Because the Q factor can be very high, (experimentally around a thousand has been demonstrated [38] with air cored coils) only a small percentage of the field has to be coupled from one coil to the other to achieve high efficiency, even though the field dies quickly with distance from a coil, the primary and secondary can be several diameters apart.
It can be shown that a figure of merit for the efficiency is: [39]
Where Q1 and Q2 are the Q factors of the source and receiver coils respectively, and k is the coupling coefficient described above.
And the maximum achievable efficiency is: [39]
Because the Q can be very high, even when low power is fed into the transmitter coil, a relatively intense field builds up over multiple cycles, which increases the power that can be received—at resonance far more power is in the oscillating field than is being fed into the coil, and the receiver coil receives a percentage of that.
Unlike the multiple-layer secondary of a non-resonant transformer, coils for this purpose are often single layer solenoids (to minimise skin effect and give improved Q) in parallel with a suitable capacitor. Alternative resonator geometries include wave-wound Litz wire and loop-gap resonators (LGRs). In the Litz wire-based resonators, insulation is either absent or low permittivity and low-loss materials such as silk are used to minimise dielectric losses.[ citation needed ] The LGR geometries have the advantage that electric fields outside the resonator structure are very weak which minimizes human exposure to electric fields and makes the power transfer efficiency insensitive to nearby dielectrics. [40]
To progressively feed energy into the primary coil with each cycle, different circuits can be used. One circuit employs a Colpitts oscillator. [38]
In Tesla coils an intermittent switching system, a "circuit controller" or "break," is used to inject an impulsive signal into the primary coil; the secondary coil then rings and decays.[ citation needed ]
The secondary receiver coils are similar designs to the primary sending coils. Running the secondary at the same resonant frequency as the primary ensures that the secondary has a low impedance at the transmitter's frequency and that the energy is optimally absorbed.
To remove energy from the secondary coil, different methods can be used, the AC can be used directly or rectified and a regulator circuit can be used to generate DC voltage.
An electromagnetic coil is an electrical conductor such as a wire in the shape of a coil. Electromagnetic coils are used in electrical engineering, in applications where electric currents interact with magnetic fields, in devices such as electric motors, generators, inductors, electromagnets, transformers, sensor coils such as in medical MRI imaging machines. Either an electric current is passed through the wire of the coil to generate a magnetic field, or conversely, an external time-varying magnetic field through the interior of the coil generates an EMF (voltage) in the conductor.
An inductor, also called a coil, choke, or reactor, is a passive two-terminal electrical component that stores energy in a magnetic field when an electric current flows through it. An inductor typically consists of an insulated wire wound into a coil.
In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits. A varying current in any coil of the transformer produces a varying magnetic flux in the transformer's core, which induces a varying electromotive force (EMF) across any other coils wound around the same core. Electrical energy can be transferred between separate coils without a metallic (conductive) connection between the two circuits. Faraday's law of induction, discovered in 1831, describes the induced voltage effect in any coil due to a changing magnetic flux encircled by the coil.
A Tesla coil is an electrical resonant transformer circuit designed by inventor Nikola Tesla in 1891. It is used to produce high-voltage, low-current, high-frequency alternating-current electricity. Tesla experimented with a number of different configurations consisting of two, or sometimes three, coupled resonant electric circuits.
In electrical engineering, two conductors are said to be inductively coupled or magnetically coupled when they are configured in a way such that change in current through one wire induces a voltage across the ends of the other wire through electromagnetic induction. A changing current through the first wire creates a changing magnetic field around it by Ampere's circuital law. The changing magnetic field induces an electromotive force (EMF) voltage in the second wire by Faraday's law of induction. The amount of inductive coupling between two conductors is measured by their mutual inductance.
Inductance is the tendency of an electrical conductor to oppose a change in the electric current flowing through it. The electric current produces a magnetic field around the conductor. The magnetic field strength depends on the magnitude of the electric current, and follows any changes in the magnitude of the current. From Faraday's law of induction, any change in magnetic field through a circuit induces an electromotive force (EMF) (voltage) in the conductors, a process known as electromagnetic induction. This induced voltage created by the changing current has the effect of opposing the change in current. This is stated by Lenz's law, and the voltage is called back EMF.
A balun is an electrical device that allows balanced and unbalanced lines to be interfaced without disturbing the impedance arrangement of either line. A balun can take many forms and may include devices that also transform impedances but need not do so. Sometimes, in the case of transformer baluns, they use magnetic coupling but need not do so. Common-mode chokes are also used as baluns and work by eliminating, rather than rejecting, common mode signals.
Wireless power transfer is the transmission of electrical energy without wires as a physical link. In a wireless power transmission system, an electrically powered transmitter device generates a time-varying electromagnetic field that transmits power across space to a receiver device; the receiver device extracts power from the field and supplies it to an electrical load. The technology of wireless power transmission can eliminate the use of the wires and batteries, thereby increasing the mobility, convenience, and safety of an electronic device for all users. Wireless power transfer is useful to power electrical devices where interconnecting wires are inconvenient, hazardous, or are not possible.
A spark-gap transmitter is an obsolete type of radio transmitter which generates radio waves by means of an electric spark. Spark-gap transmitters were the first type of radio transmitter, and were the main type used during the wireless telegraphy or "spark" era, the first three decades of radio, from 1887 to the end of World War I. German physicist Heinrich Hertz built the first experimental spark-gap transmitters in 1887, with which he proved the existence of radio waves and studied their properties.
An Oudin coil, also called an Oudin oscillator or Oudin resonator, is a resonant transformer circuit that generates very high voltage, high frequency alternating current (AC) electricity at low current levels, used in the obsolete forms of electrotherapy around the turn of the 20th century. It is very similar to the Tesla coil, with the difference being that the Oudin coil was connected as an autotransformer. It was invented in 1893 by French physician Paul Marie Oudin as a modification of physician Jacques Arsene d'Arsonval's electrotherapy equipment and used in medical diathermy therapy as well as quack medicine until perhaps 1940. The high voltage output terminal of the coil was connected to an insulated handheld electrode which produced luminous brush discharges, which were applied to the patient's body to treat various medical conditions in electrotherapy.
A bifilar coil is an electromagnetic coil that contains two closely spaced, parallel windings. In electrical engineering, the word bifilar describes wire which is made of two filaments or strands. It is commonly used to denote special types of winding wire for transformers. Wire can be purchased in bifilar form, usually as different colored enameled wire bonded together. For three strands, the term trifilar coil is used.
A blocking oscillator is a simple configuration of discrete electronic components which can produce a free-running signal, requiring only a resistor, a transformer, and one amplifying element such as a transistor or vacuum tube. The name is derived from the fact that the amplifying element is cut-off or "blocked" for most of the duty cycle, producing periodic pulses on the principle of a relaxation oscillator. The non-sinusoidal output is not suitable for use as a radio-frequency local oscillator, but it can serve as a timing generator, to power lights, LEDs, EL wire, or small neon indicators. If the output is used as an audio signal, the simple tones are also sufficient for applications such as alarms or a Morse code practice device. Some cameras use a blocking oscillator to strobe the flash prior to a shot to reduce the red-eye effect.
Electrical resonance occurs in an electric circuit at a particular resonant frequency when the impedances or admittances of circuit elements cancel each other. In some circuits, this happens when the impedance between the input and output of the circuit is almost zero and the transfer function is close to one.
In electronics, electric power and telecommunication, coupling is the transfer of electrical energy from one circuit to another, or between parts of a circuit. Coupling can be deliberate as part of the function of the circuit, or it may be undesirable, for instance due to coupling to stray fields. For example, energy is transferred from a power source to an electrical load by means of conductive coupling, which may be either resistive or direct coupling. An AC potential may be transferred from one circuit segment to another having a DC potential by use of a capacitor. Electrical energy may be transferred from one circuit segment to another segment with different impedance by use of a transformer; this is known as impedance matching. These are examples of electrostatic and electrodynamic inductive coupling.
Various types of electrical transformer are made for different purposes. Despite their design differences, the various types employ the same basic principle as discovered in 1831 by Michael Faraday, and share several key functional parts.
WREL is a form of wireless resonant energy transfer technology developed by Intel.
Qi is an interface standard for wireless power transfer using inductive charging. The standard allows compatible devices, such as smartphones, to charge their batteries when placed on a Qi charging pad, which can be effective over distances up to 4 cm.
This glossary of electrical and electronics engineering is a list of definitions of terms and concepts related specifically to electrical engineering and electronics engineering. For terms related to engineering in general, see Glossary of engineering.
Short-circuit inductance of a real linear two-winding transformer is inductance measured across the primary or secondary winding when the other winding is short-circuited. The method of measuring the short circuit inductance is described in industrial standard. The industrial standard also stipulates a method for obtaining the coupling factor by combining it with the open circuit inductance value.
Nikola Tesla patented the Tesla coil circuit on April 25, 1891. and first publicly demonstrated it May 20, 1891 in his lecture "Experiments with Alternate Currents of Very High Frequency and Their Application to Methods of Artificial Illumination" before the American Institute of Electrical Engineers at Columbia College, New York. Although Tesla patented many similar circuits during this period, this was the first that contained all the elements of the Tesla coil: high voltage primary transformer, capacitor, spark gap, and air core "oscillation transformer".
Published online: April 2007
{{cite web}}
: CS1 maint: archived copy as title (link) ICNIRP Guidelines Guidelines for Limiting Exposure to Time-Varying ...