Negative feedback

Last updated
A simple negative feedback system is descriptive, for example, of some electronic amplifiers. The feedback is negative if the loop gain AB is negative. Ideal feedback model.svg
A simple negative feedback system is descriptive, for example, of some electronic amplifiers. The feedback is negative if the loop gain AB is negative.

Negative feedback (or balancing feedback) occurs when some function of the output of a system, process, or mechanism is fed back in a manner that tends to reduce the fluctuations in the output, whether caused by changes in the input or by other disturbances. A classic example of negative feedback is a heating system thermostat — when the temperature gets high enough, the heater is turned OFF. When the temperature gets too cold, the heat is turned back ON. In each case the "feedback" generated by the thermostat "negates" the trend.

Contents

The opposite tendency — called positive feedback — is when a trend is positively reinforced, creating amplification, such as the squealing "feedback" loop that can occur when a mic is brought too close to a speaker which is amplifying the very sounds the mic is picking up, or the runaway heating and ultimate meltdown of a nuclear reactor.

Whereas positive feedback tends to lead to instability via exponential growth, oscillation or chaotic behavior, negative feedback generally promotes stability. Negative feedback tends to promote a settling to equilibrium, and reduces the effects of perturbations. Negative feedback loops in which just the right amount of correction is applied with optimum timing, can be very stable, accurate, and responsive.

Negative feedback is widely used in mechanical and electronic engineering, and also within living organisms, [1] [2] and can be seen in many other fields from chemistry and economics to physical systems such as the climate. General negative feedback systems are studied in control systems engineering.

Negative feedback loops also play an integral role in maintaining the atmospheric balance in various systems on Earth. One such feedback system is the interaction between solar radiation, cloud cover, and planet temperature.

Blood glucose levels are maintained at a constant level in the body by a negative feedback mechanism. When the blood glucose level is too high, the pancreas secretes insulin and when the level is too low, the pancreas then secretes glucagon. The flat line shown represents the homeostatic set point. The sinusoidal line represents the blood glucose level. Negative Feedback Gif.gif
Blood glucose levels are maintained at a constant level in the body by a negative feedback mechanism. When the blood glucose level is too high, the pancreas secretes insulin and when the level is too low, the pancreas then secretes glucagon. The flat line shown represents the homeostatic set point. The sinusoidal line represents the blood glucose level.

General description

Feedback loops in the human body 105 Negative Feedback Loops.jpg
Feedback loops in the human body

In many physical and biological systems, qualitatively different influences can oppose each other. For example, in biochemistry, one set of chemicals drives the system in a given direction, whereas another set of chemicals drives it in an opposing direction. If one or both of these opposing influences are non-linear, equilibrium point(s) result.

In biology, this process (in general, biochemical) is often referred to as homeostasis; whereas in mechanics, the more common term is equilibrium.

In engineering, mathematics and the physical, and biological sciences, common terms for the points around which the system gravitates include: attractors, stable states, eigenstates/eigenfunctions, equilibrium points, and setpoints.

In control theory, negative refers to the sign of the multiplier in mathematical models for feedback. In delta notation, −Δoutput is added to or mixed into the input. In multivariate systems, vectors help to illustrate how several influences can both partially complement and partially oppose each other. [3]

Some authors, in particular with respect to modelling business systems, use negative to refer to the reduction in difference between the desired and actual behavior of a system. [4] [5] In a psychology context, on the other hand, negative refers to the valence of the feedback – attractive versus aversive, or praise versus criticism. [6]

In contrast, positive feedback is feedback in which the system responds so as to increase the magnitude of any particular perturbation, resulting in amplification of the original signal instead of stabilization. Any system in which there is positive feedback together with a gain greater than one will result in a runaway situation. Both positive and negative feedback require a feedback loop to operate.

However, negative feedback systems can still be subject to oscillations. This is caused by a phase shift around any loop. Due to these phase shifts the feedback signal of some frequencies can ultimately become in phase with the input signal and thus turn into positive feedback, creating a runaway condition. Even before the point where the phase shift becomes 180 degrees, stability of the negative feedback loop will become compromised, leading to increasing under- and overshoot following a disturbance. This problem is often dealt with by attenuating or changing the phase of the problematic frequencies in a design step called compensation. Unless the system naturally has sufficient damping, many negative feedback systems have low pass filters or dampers fitted.

Examples

An example of a negative feedback loop is the process of increasing and decreasing glucose levels in out bloodstream.svg

Detailed implementations

Error-controlled regulation

Basic error-controlled regulator loop Basic error-controlled regulator.svg
Basic error-controlled regulator loop
A regulator R adjusts the input to a system T so the monitored essential variables E are held to set-point values S that result in the desired system output despite disturbances D. Regulator with feedback.png
A regulator R adjusts the input to a system T so the monitored essential variables E are held to set-point values S that result in the desired system output despite disturbances D.

One use of feedback is to make a system (say T) self-regulating to minimize the effect of a disturbance (say D). Using a negative feedback loop, a measurement of some variable (for example, a process variable, say E) is subtracted from a required value (the 'set point') to estimate an operational error in system status, which is then used by a regulator (say R) to reduce the gap between the measurement and the required value. [8] [9] The regulator modifies the input to the system T according to its interpretation of the error in the status of the system. This error may be introduced by a variety of possible disturbances or 'upsets', some slow and some rapid. [10] The regulation in such systems can range from a simple 'on-off' control to a more complex processing of the error signal. [11]

In this framework, the physical form of a signal may undergo multiple transformations. For example, a change in weather may cause a disturbance to the heat input to a house (as an example of the system T) that is monitored by a thermometer as a change in temperature (as an example of an 'essential variable' E). This quantity, then, is converted by the thermostat (a 'comparator') into an electrical error in status compared to the 'set point' S, and subsequently used by the regulator (containing a 'controller' that commands gas control valves and an ignitor) ultimately to change the heat provided by a furnace (an 'effector') to counter the initial weather-related disturbance in heat input to the house. [12]

Error controlled regulation is typically carried out using a Proportional-Integral-Derivative Controller (PID controller). The regulator signal is derived from a weighted sum of the error signal, integral of the error signal, and derivative of the error signal. The weights of the respective components depend on the application. [13]

Mathematically, the regulator signal is given by:

where

is the integral time
is the derivative time

Negative feedback amplifier

The negative feedback amplifier was invented by Harold Stephen Black at Bell Laboratories in 1927, and granted a patent in 1937 (US Patent 2,102,671) [14] "a continuation of application Serial No. 298,155, filed August 8, 1928 ..."). [15] [16]

"The patent is 52 pages long plus 35 pages of figures. The first 43 pages amount to a small treatise on feedback amplifiers!" [16]

There are many advantages to feedback in amplifiers. [17] In design, the type of feedback and amount of feedback are carefully selected to weigh and optimize these various benefits.

Advantages of negative voltage feedback in amplifiers

  1. It reduces non-linear distortion, that is, it has higher fidelity.
  2. It increases circuit stability: that is, the gain remains stable though there are variations in ambient temperature, frequency and signal amplitude.
  3. It increases bandwidth slightly.
  4. It modifies the input and output impedances.
  5. Harmonic, phase, amplitude, and frequency distortions are all reduced considerably.
  6. Noise is reduced considerably.

Though negative feedback has many advantages, amplifiers with feedback can oscillate. See the article on step response. They may even exhibit instability. Harry Nyquist of Bell Laboratories proposed the Nyquist stability criterion and the Nyquist plot that identify stable feedback systems, including amplifiers and control systems.

Negative feedback amplifier with external disturbance. The feedback is negative if bA >0. Negative feedback amplifier with disturbance.png
Negative feedback amplifier with external disturbance. The feedback is negative if βA>0.

The figure shows a simplified block diagram of a negative feedback amplifier.

The feedback sets the overall (closed-loop) amplifier gain at a value:

where the approximate value assumes βA >> 1. This expression shows that a gain greater than one requires β < 1. Because the approximate gain 1/β is independent of the open-loop gain A, the feedback is said to 'desensitize' the closed-loop gain to variations in A (for example, due to manufacturing variations between units, or temperature effects upon components), provided only that the gain A is sufficiently large. [19] In this context, the factor (1+βA) is often called the 'desensitivity factor', [20] [21] and in the broader context of feedback effects that include other matters like electrical impedance and bandwidth, the 'improvement factor'. [22]

If the disturbance D is included, the amplifier output becomes:

which shows that the feedback reduces the effect of the disturbance by the 'improvement factor' (1+βA). The disturbance D might arise from fluctuations in the amplifier output due to noise and nonlinearity (distortion) within this amplifier, or from other noise sources such as power supplies. [23] [24]

The difference signal IβO at the amplifier input is sometimes called the "error signal". [25] According to the diagram, the error signal is:

From this expression, it can be seen that a large 'improvement factor' (or a large loop gain βA) tends to keep this error signal small.

Although the diagram illustrates the principles of the negative feedback amplifier, modeling a real amplifier as a unilateral forward amplification block and a unilateral feedback block has significant limitations. [26] For methods of analysis that do not make these idealizations, see the article Negative feedback amplifier.

Operational amplifier circuits

A feedback voltage amplifier using an op amp with finite gain but infinite input impedances and zero output impedance. Feedback op-amp voltage amplifier.png
A feedback voltage amplifier using an op amp with finite gain but infinite input impedances and zero output impedance.

The operational amplifier was originally developed as a building block for the construction of analog computers, but is now used almost universally in all kinds of applications including audio equipment and control systems.

Operational amplifier circuits typically employ negative feedback to get a predictable transfer function. Since the open-loop gain of an op-amp is extremely large, a small differential input signal would drive the output of the amplifier to one rail or the other in the absence of negative feedback. A simple example of the use of feedback is the op-amp voltage amplifier shown in the figure.

The idealized model of an operational amplifier assumes that the gain is infinite, the input impedance is infinite, output resistance is zero, and input offset currents and voltages are zero. Such an ideal amplifier draws no current from the resistor divider. [28] Ignoring dynamics (transient effects and propagation delay), the infinite gain of the ideal op-amp means this feedback circuit drives the voltage difference between the two op-amp inputs to zero. [28] Consequently, the voltage gain of the circuit in the diagram, assuming an ideal op amp, is the reciprocal of feedback voltage division ratio β:

.

A real op-amp has a high but finite gain A at low frequencies, decreasing gradually at higher frequencies. In addition, it exhibits a finite input impedance and a non-zero output impedance. Although practical op-amps are not ideal, the model of an ideal op-amp often suffices to understand circuit operation at low enough frequencies. As discussed in the previous section, the feedback circuit stabilizes the closed-loop gain and desensitizes the output to fluctuations generated inside the amplifier itself. [29]

Areas of application

Mechanical engineering

The ballcock or float valve uses negative feedback to control the water level in a cistern. Ballcock.svg
The ballcock or float valve uses negative feedback to control the water level in a cistern.

An example of the use of negative feedback control is the ballcock control of water level (see diagram), or a pressure regulator. In modern engineering, negative feedback loops are found in engine governors, fuel injection systems and carburettors. Similar control mechanisms are used in heating and cooling systems, such as those involving air conditioners, refrigerators, or freezers.

Biology

Control of endocrine hormones by negative feedback. ACTH Negative Feedback.svg
Control of endocrine hormones by negative feedback.

Some biological systems exhibit negative feedback such as the baroreflex in blood pressure regulation and erythropoiesis. Many biological processes (e.g., in the human anatomy) use negative feedback. Examples of this are numerous, from the regulating of body temperature, to the regulating of blood glucose levels. The disruption of feedback loops can lead to undesirable results: in the case of blood glucose levels, if negative feedback fails, the glucose levels in the blood may begin to rise dramatically, thus resulting in diabetes.

For hormone secretion regulated by the negative feedback loop: when gland X releases hormone X, this stimulates target cells to release hormone Y. When there is an excess of hormone Y, gland X "senses" this and inhibits its release of hormone X. As shown in the figure, most endocrine hormones are controlled by a physiologic negative feedback inhibition loop, such as the glucocorticoids secreted by the adrenal cortex. The hypothalamus secretes corticotropin-releasing hormone (CRH), which directs the anterior pituitary gland to secrete adrenocorticotropic hormone (ACTH). In turn, ACTH directs the adrenal cortex to secrete glucocorticoids, such as cortisol. Glucocorticoids not only perform their respective functions throughout the body but also negatively affect the release of further stimulating secretions of both the hypothalamus and the pituitary gland, effectively reducing the output of glucocorticoids once a sufficient amount has been released. [30]

Chemistry

Closed systems containing substances undergoing a reversible chemical reaction can also exhibit negative feedback in accordance with Le Chatelier's principle which shift the chemical equilibrium to the opposite side of the reaction in order to reduce a stress. For example, in the reaction

N2 + 3 H2 ⇌ 2 NH3 + 92 kJ/mol

If a mixture of the reactants and products exists at equilibrium in a sealed container and nitrogen gas is added to this system, then the equilibrium will shift toward the product side in response. If the temperature is raised, then the equilibrium will shift toward the reactant side which, since the reverse reaction is endothermic, will partially reduce the temperature.

Self-organization

Self-organization is the capability of certain systems "of organizing their own behavior or structure". [31] There are many possible factors contributing to this capacity, and most often positive feedback is identified as a possible contributor. However, negative feedback also can play a role. [32]

Economics

In economics, automatic stabilisers are government programs that are intended to work as negative feedback to dampen fluctuations in real GDP.

Mainstream economics asserts that the market pricing mechanism operates to match supply and demand, because mismatches between them feed back into the decision-making of suppliers and demanders of goods, altering prices and thereby reducing any discrepancy. However Norbert Wiener wrote in 1948:

"There is a belief current in many countries and elevated to the rank of an official article of faith in the United States that free competition is itself a homeostatic process... Unfortunately the evidence, such as it is, is against this simple-minded theory." [33]

The notion of economic equilibrium being maintained in this fashion by market forces has also been questioned by numerous heterodox economists such as financier George Soros [34] and leading ecological economist and steady-state theorist Herman Daly, who was with the World Bank in 1988–1994. [35]

Environmental Science

Some effects of climate change can either enhance (positive feedbacks) or weaken (negative feedbacks) global warming. Observations and modeling studies indicate that there is a net positive feedback to Earth's current global warming. 20220726 Feedbacks affecting global warming and climate change - block diagram.svg
Some effects of climate change can either enhance (positive feedbacks) or weaken (negative feedbacks) global warming. Observations and modeling studies indicate that there is a net positive feedback to Earth's current global warming.

A basic and common example of a negative feedback system in the environment is the interaction among cloud cover, plant growth, solar radiation, and planet temperature. [39] As incoming solar radiation increases, planet temperature increases. As the temperature increases, the amount of plant life that can grow increases. This plant life can then make products such as sulfur which produce more cloud cover. An increase in cloud cover leads to higher albedo, or surface reflectivity, of the Earth. As albedo increases, however, the amount of solar radiation decreases. [40] This, in turn, affects the rest of the cycle.

Cloud cover, and in turn planet albedo and temperature, is also influenced by the hydrological cycle. [41] As planet temperature increases, more water vapor is produced, creating more clouds. [42] The clouds then block incoming solar radiation, lowering the temperature of the planet. This interaction produces less water vapor and therefore less cloud cover. The cycle then repeats in a negative feedback loop. In this way, negative feedback loops in the environment have a stabilizing effect. [43]

History

Negative feedback as a control technique may be seen in the refinements of the water clock introduced by Ktesibios of Alexandria in the 3rd century BCE. Self-regulating mechanisms have existed since antiquity, and were used to maintain a constant level in the reservoirs of water clocks as early as 200 BCE. [44]

The fly-ball governor is an early example of negative feedback. Centrifugal governor.png
The fly-ball governor is an early example of negative feedback.

Negative feedback was implemented in the 17th century. Cornelius Drebbel had built thermostatically controlled incubators and ovens in the early 1600s, [45] and centrifugal governors were used to regulate the distance and pressure between millstones in windmills. [46] James Watt patented a form of governor in 1788 to control the speed of his steam engine, and James Clerk Maxwell in 1868 described "component motions" associated with these governors that lead to a decrease in a disturbance or the amplitude of an oscillation. [47]

The term "feedback" was well established by the 1920s, in reference to a means of boosting the gain of an electronic amplifier. [3] Friis and Jensen described this action as "positive feedback" and made passing mention of a contrasting "negative feed-back action" in 1924. [48] Harold Stephen Black came up with the idea of using negative feedback in electronic amplifiers in 1927, submitted a patent application in 1928, [15] and detailed its use in his paper of 1934, where he defined negative feedback as a type of coupling that reduced the gain of the amplifier, in the process greatly increasing its stability and bandwidth. [49] [50]

Karl Küpfmüller published papers on a negative-feedback-based automatic gain control system and a feedback system stability criterion in 1928. [51]

Nyquist and Bode built on Black's work to develop a theory of amplifier stability. [50]

Early researchers in the area of cybernetics subsequently generalized the idea of negative feedback to cover any goal-seeking or purposeful behavior. [52]

All purposeful behavior may be considered to require negative feed-back. If a goal is to be attained, some signals from the goal are necessary at some time to direct the behavior.

Cybernetics pioneer Norbert Wiener helped to formalize the concepts of feedback control, defining feedback in general as "the chain of the transmission and return of information", [53] and negative feedback as the case when:

The information fed back to the control center tends to oppose the departure of the controlled from the controlling quantity...:97

While the view of feedback as any "circularity of action" helped to keep the theory simple and consistent, Ashby pointed out that, while it may clash with definitions that require a "materially evident" connection, "the exact definition of feedback is nowhere important". [1] Ashby pointed out the limitations of the concept of "feedback":

The concept of 'feedback', so simple and natural in certain elementary cases, becomes artificial and of little use when the interconnections between the parts become more complex...Such complex systems cannot be treated as an interlaced set of more or less independent feedback circuits, but only as a whole. For understanding the general principles of dynamic systems, therefore, the concept of feedback is inadequate in itself. What is important is that complex systems, richly cross-connected internally, have complex behaviors, and that these behaviors can be goal-seeking in complex patterns.:54

To reduce confusion, later authors have suggested alternative terms such as degenerative, [54] self-correcting, [55] balancing, [56] or discrepancy-reducing [57] in place of "negative".

See also

Related Research Articles

An electronic oscillator is an electronic circuit that produces a periodic, oscillating or alternating current (AC) signal, usually a sine wave, square wave or a triangle wave, powered by a direct current (DC) source. Oscillators are found in many electronic devices, such as radio receivers, television sets, radio and television broadcast transmitters, computers, computer peripherals, cellphones, radar, and many other devices.

<span class="mw-page-title-main">Amplifier</span> Electronic device/component that increases the strength of a signal

An amplifier, electronic amplifier or (informally) amp is an electronic device that can increase the magnitude of a signal. It is a two-port electronic circuit that uses electric power from a power supply to increase the amplitude of a signal applied to its input terminals, producing a proportionally greater amplitude signal at its output. The amount of amplification provided by an amplifier is measured by its gain: the ratio of output voltage, current, or power to input. An amplifier is defined as a circuit that has a power gain greater than one.

<span class="mw-page-title-main">Feedback</span> Process where information about current status is used to influence future status

Feedback occurs when outputs of a system are routed back as inputs as part of a chain of cause-and-effect that forms a circuit or loop. The system can then be said to feed back into itself. The notion of cause-and-effect has to be handled carefully when applied to feedback systems:

Simple causal reasoning about a feedback system is difficult because the first system influences the second and second system influences the first, leading to a circular argument. This makes reasoning based upon cause and effect tricky, and it is necessary to analyze the system as a whole. As provided by Webster, feedback in business is the transmission of evaluative or corrective information about an action, event, or process to the original or controlling source.

<span class="mw-page-title-main">Operational amplifier</span> High-gain voltage amplifier with a differential input

An operational amplifier is a DC-coupled electronic voltage amplifier with a differential input, a (usually) single-ended output, and an extremely high gain. Its name comes from its original use of performing mathematical operations in analog computers.

<span class="mw-page-title-main">Loop gain</span> Sum of the gain around a feedback loop

In electronics and control system theory, loop gain is the sum of the gain, expressed as a ratio or in decibels, around a feedback loop. Feedback loops are widely used in electronics in amplifiers and oscillators, and more generally in both electronic and nonelectronic industrial control systems to control industrial plant and equipment. The concept is also used in biology. In a feedback loop, the output of a device, process or plant is sampled and applied to alter the input, to better control the output. The loop gain, along with the related concept of loop phase shift, determines the behavior of the device, and particularly whether the output is stable, or unstable, which can result in oscillation. The importance of loop gain as a parameter for characterizing electronic feedback amplifiers was first recognized by Heinrich Barkhausen in 1921, and was developed further by Hendrik Wade Bode and Harry Nyquist at Bell Labs in the 1930s.

<span class="mw-page-title-main">Negative-feedback amplifier</span> Type of electronic amplifier

A negative-feedback amplifier is an electronic amplifier that subtracts a fraction of its output from its input, so that negative feedback opposes the original signal. The applied negative feedback can improve its performance and reduces sensitivity to parameter variations due to manufacturing or environment. Because of these advantages, many amplifiers and control systems use negative feedback.

<span class="mw-page-title-main">Positive feedback</span> Feedback loop that increases an initial small effect

Positive feedback is a process that occurs in a feedback loop which exacerbates the effects of a small disturbance. That is, the effects of a perturbation on a system include an increase in the magnitude of the perturbation. That is, A produces more of B which in turn produces more of A. In contrast, a system in which the results of a change act to reduce or counteract it has negative feedback. Both concepts play an important role in science and engineering, including biology, chemistry, and cybernetics.

<span class="mw-page-title-main">Instrumentation amplifier</span> Electronic amplifier, a circuit component

An instrumentation amplifier is a type of differential amplifier that has been outfitted with input buffer amplifiers, which eliminate the need for input impedance matching and thus make the amplifier particularly suitable for use in measurement and test equipment. Additional characteristics include very low DC offset, low drift, low noise, very high open-loop gain, very high common-mode rejection ratio, and very high input impedances. Instrumentation amplifiers are used where great accuracy and stability of the circuit both short- and long-term are required.

<span class="mw-page-title-main">Step response</span> Time behavior of a system controlled by Heaviside step functions

The step response of a system in a given initial state consists of the time evolution of its outputs when its control inputs are Heaviside step functions. In electronic engineering and control theory, step response is the time behaviour of the outputs of a general system when its inputs change from zero to one in a very short time. The concept can be extended to the abstract mathematical notion of a dynamical system using an evolution parameter.

In electronics engineering, frequency compensation is a technique used in amplifiers, and especially in amplifiers employing negative feedback. It usually has two primary goals: To avoid the unintentional creation of positive feedback, which will cause the amplifier to oscillate, and to control overshoot and ringing in the amplifier's step response. It is also used extensively to improve the bandwidth of single pole systems.

<span class="mw-page-title-main">Asymptotic gain model</span>

The asymptotic gain model is a representation of the gain of negative feedback amplifiers given by the asymptotic gain relation:

An integrator in measurement and control applications is an element whose output signal is the time integral of its input signal. It accumulates the input quantity over a defined time to produce a representative output.

Linear electronic oscillator circuits, which generate a sinusoidal output signal, are composed of an amplifier and a frequency selective element, a filter. A linear oscillator circuit which uses an RC network, a combination of resistors and capacitors, for its frequency selective part is called an RC oscillator.

<span class="mw-page-title-main">Wien bridge oscillator</span> Electric circuit that generates sine waves

A Wien bridge oscillator is a type of electronic oscillator that generates sine waves. It can generate a large range of frequencies. The oscillator is based on a bridge circuit originally developed by Max Wien in 1891 for the measurement of impedances. The bridge comprises four resistors and two capacitors. The oscillator can also be viewed as a positive gain amplifier combined with a bandpass filter that provides positive feedback. Automatic gain control, intentional non-linearity and incidental non-linearity limit the output amplitude in various implementations of the oscillator.

The open-loop gain of an electronic amplifier is the gain obtained when no overall feedback is used in the circuit.

This article illustrates some typical operational amplifier applications. A non-ideal operational amplifier's equivalent circuit has a finite input impedance, a non-zero output impedance, and a finite gain. A real op-amp has a number of non-ideal features as shown in the diagram, but here a simplified schematic notation is used, many details such as device selection and power supply connections are not shown. Operational amplifiers are optimised for use with negative feedback, and this article discusses only negative-feedback applications. When positive feedback is required, a comparator is usually more appropriate. See Comparator applications for further information.

In electronic amplifiers, the phase margin (PM) is the difference between the phase lag φ and -180°, for an amplifier's output signal at zero dB gain - i.e. unity gain, or that the output signal has the same amplitude as the input.

A fully differential amplifier (FDA) is a DC-coupled high-gain electronic voltage amplifier with differential inputs and differential outputs. In its ordinary usage, the output of the FDA is controlled by two feedback paths which, because of the amplifier's high gain, almost completely determine the output voltage for any given input.

<span class="mw-page-title-main">Transimpedance amplifier</span> Amplifier that converts current to voltage

In electronics, a transimpedance amplifier (TIA) is a current to voltage converter, almost exclusively implemented with one or more operational amplifiers. The TIA can be used to amplify the current output of Geiger–Müller tubes, photo multiplier tubes, accelerometers, photo detectors and other types of sensors to a usable voltage. Current to voltage converters are used with sensors that have a current response that is more linear than the voltage response. This is the case with photodiodes where it is not uncommon for the current response to have better than 1% nonlinearity over a wide range of light input. The transimpedance amplifier presents a low impedance to the photodiode and isolates it from the output voltage of the operational amplifier. In its simplest form a transimpedance amplifier has just a large valued feedback resistor, Rf. The gain of the amplifier is set by this resistor and because the amplifier is in an inverting configuration, has a value of -Rf. There are several different configurations of transimpedance amplifiers, each suited to a particular application. The one factor they all have in common is the requirement to convert the low-level current of a sensor to a voltage. The gain, bandwidth, as well as current and voltage offsets change with different types of sensors, requiring different configurations of transimpedance amplifiers.

The operational amplifier integrator is an electronic integration circuit. Based on the operational amplifier (op-amp), it performs the mathematical operation of integration with respect to time; that is, its output voltage is proportional to the input voltage integrated over time.

References

  1. 1 2 3 W. Ross Ashby (1957). "Chapter 12: The error-controlled regulator" (PDF). Introduction to cybernetics. Chapman & Hall Ltd.; Internet (1999). pp. 219–243.
  2. Robert E. Ricklefs; Gary Leon Miller (2000). "§6.1 Homeostasis depends upon negative feedback". Ecology. Macmillan. p. 92. ISBN   9780716728290.
  3. 1 2 David A. Mindell (2002). Between Human and Machine : Feedback, Control, and Computing before Cybernetics. Baltimore, MD, USA: Johns Hopkins University Press. ISBN   9780801868955.
  4. Arkalgud Ramaprasad (1983). "On The Definition of Feedback". Behavioral Science. 28 (1): 4–13. doi:10.1002/bs.3830280103.
  5. John D.Sterman, Business Dynamics: Systems Thinking and Modeling for a Complex World McGraw Hill/Irwin, 2000. ISBN   9780072389159
  6. Herold, David M.; Greller, Martin M. (1977). "Research Notes. Feedback: The Definition of a Construct". Academy of Management Journal. 20 (1): 142–147. doi:10.2307/255468. JSTOR   255468.
  7. Sudheer S Bhagade; Govind Das Nageshwar (2011). Process Dynamics and Control. PHI Learning Pvt. Ltd. pp. 6, 9. ISBN   9788120344051.
  8. Charles H. Wilts (1960). Principles of Feedback Control . Addison-Wesley Pub. Co. p.  1. In a simple feedback system a specific physical quantity is being controlled, and control is brought about by making an actual comparison of this quantity with its desired value and utilizing the difference to reduce the error observed. Such a system is self-correcting in the sense that any deviations from the desired performance are used to produce corrective action.
  9. SK Singh (2010). Process Control: Concepts Dynamics And Applications. PHI Learning Pvt. Ltd. p. 222. ISBN   9788120336780.
  10. For example, input and load disturbances. See William Y. Svrcek; Donald P. Mahoney; Brent R. Young (2013). A Real-Time Approach to Process Control (3rd ed.). John Wiley & Sons. p. 57. ISBN   9781118684733.
  11. Charles D H Williams. "Types of feedback control". Feedback and temperature control. University of Exeter: Physics and astronomy. Retrieved 2014-06-08.
  12. Giannini, Alessandra; Biasutti, Michela; Verstraete, Michel M. (2008-12-01). "A climate model-based review of drought in the Sahel: Desertification, the re-greening and climate change". Global and Planetary Change. Climate Change and Desertification. 64 (3): 119–128. Bibcode:2008GPC....64..119G. doi:10.1016/j.gloplacha.2008.05.004. ISSN   0921-8181.
  13. Bechhoefer, John (2005). "Feedback for Physicists: A Tutorial Essay On Control". Reviews of Modern Physics. 77 (3): 783–835. Bibcode:2005RvMP...77..783B. CiteSeerX   10.1.1.124.7043 . doi:10.1103/revmodphys.77.783.
  14. Black, Harold (1937-12-21). "U.S. Patent 2,102,671: Wave Translation System" (PDF). www.eepatents.com. Archived from the original (PDF) on 2014-10-06.
  15. 1 2 James E Brittain (February 2011). "Electrical engineering hall of fame: Harold S Black" (PDF). Proceedings of the IEEE. 99 (2): 351–353. doi:10.1109/jproc.2010.2090997.
  16. 1 2 CA Desoer (August 1984). "In Memoriam: Harold Stephen Black". IEEE Transactions on Automatic Control. AC-29 (8): 673–674. doi:10.1109/tac.1984.1103645.
  17. Santiram Kal (2009). "§6.3 Advantages of negative feedback amplifiers". Basic electronics: Devices, circuits and its fundamentals. PHI Learning Pvt. Ltd. pp. 193 ff. ISBN   9788120319523.
  18. Marc Thomson (2006). "Figure 11-4: Classical single input, single output control loop". Intuitive Analog Circuit Design. Newnes. ISBN   9780080478753.
  19. Santiram Kal (2009). "§6.3.1 Gain stability". Basic Electronics: Devices, Circuits, and IT Fundamentals. PHI Learning Pvt. Ltd. pp. 193–194. ISBN   9788120319523.
  20. Marc T Thompson, p. 309
  21. Thomas H Lee (2004). The Design of CMOS Radio Frequency Circuits (2nd ed.). Cambridge University Press. p. 447. ISBN   9780521835398.
  22. Norbert A Malik (1995). "Improvement Factor". Electronic Circuits: Analysis simulation and design. Prentice Hall. p. 671. ISBN   9780023749100.
  23. Santiram Kal (14 January 2009). "§6.3.2 Noise Reduction". Basic Electronics: Devices, Circuits and IT fundamentals. p. 194. ISBN   9788120319523.
  24. SK Bhattacharya. "§5.3.3 Effect of feedback on disturbance signal". Linear Control Systems: For Punjab Technical University. ISBN   9788131759523.
  25. Muhammad Rashid (2010). Microelectronic Circuits: Analysis & Design (2nd ed.). Cengage Learning. p. 642. ISBN   9780495667728.
  26. Wai-Kai Chen (2005). "Chapter 13: General feedback theory". Circuit Analysis and Feedback Amplifier Theory. CRC Press. pp. 13–1. ISBN   9781420037272. [In a practical amplifier] the forward path may not be strictly unilateral, the feedback path is usually bilateral, and the input and output coupling networks are often complicated.
  27. See, for example, Figure 1.4, p. 7 Ideal op amp model in Sergio Franco (2002). Design with operational amplifiers and analog integrated circuits (3rd ed.). McGraw-Hill. ISBN   978-0078028168. or David G Nair; Sergio B Franco (2009). "Figure 16.2: The four possible op-amp configurations". In Wai-Kai Chen (ed.). Fundamentals of Circuits and Filters (The Circuits and Filters Handbook, 3rd ed.). CRC Press. pp. 16–2. ISBN   9781420058888.
  28. 1 2 G. Schitter; A. Rankers (2014). "§6.3.4 Linear amplifiers with operational amplifiers". The Design of High Performance Mechatronics. IOS Press. p. 499. ISBN   9781614993681.
  29. Walter G Jung (2005). "Noise gain (NG)". Op Amp Applications Handbook. Newnes. pp. 12 ff. ISBN   9780750678445.
  30. Raven, PH; Johnson, GB. Biology, Fifth Edition, Boston: Hill Companies, Inc. 1999. page 1058.
  31. William R. Uttal (2014). Psychomythics: Sources of Artifacts and Misconceptions in Scientific Psychology. Psychology Press. pp. 95 ff. ISBN   9781135623722.
  32. Scott Camazine; Jean-Louis Deneubourg; Nigel R Franks; James Sneyd; Guy Theraulaz; Eric Bonabeau (2003). "Chapter 2: How self-organization works". Self-organization in biological systems. Princeton University Press. pp. 15 ff. ISBN   9780691116242.
  33. Cybernetics: Or Control and Communication in the Animal and the Machine p.158
  34. Goeroge Soros, The Alchemy of Finance
  35. Herman Daly, Steady State Economics
  36. "The Study of Earth as an Integrated System". nasa.gov. NASA. 2016. Archived from the original on November 2, 2016.
  37. Fig. TS.17, Technical Summary, Sixth Assessment Report (AR6), Working Group I, IPCC, 2021, p. 96. Archived from the original on July 21, 2022.
  38. Stocker, Thomas F.; Dahe, Qin; Plattner, Gian-Kaksper (2013). IPCC AR5 WG1. Technical Summary (PDF). Archived (PDF) from the original on 16 July 2023. See esp. TFE.6: Climate Sensitivity and Feedbacks at p. 82.
  39. Charlson, Robert J.; Lovelock, James E.; Andreae, Meinrat O.; Warren, Stephen G. (1987). "Oceanic phytoplankton, atmospheric sulphur, cloud albedo and climate". Nature. 326 (6114): 655–661. Bibcode:1987Natur.326..655C. doi:10.1038/326655a0. ISSN   1476-4687. S2CID   4321239.
  40. Winton, Michael (2006). "Amplified Arctic climate change: What does surface albedo feedback have to do with it?". Geophysical Research Letters. 33 (3): L03701. Bibcode:2006GeoRL..33.3701W. doi: 10.1029/2005GL025244 . ISSN   1944-8007.
  41. Stephens, Graeme L. (2005). "Cloud Feedbacks in the Climate System: A Critical Review". Journal of Climate. 18 (2): 237–273. Bibcode:2005JCli...18..237S. doi: 10.1175/JCLI-3243.1 . ISSN   0894-8755. S2CID   16122908.
  42. Jickells, T. D.; An, Z. S.; Andersen, K. K.; Baker, A. R.; Bergametti, G.; Brooks, N.; Cao, J. J.; Boyd, P. W.; Duce, R. A.; Hunter, K. A.; Kawahata, H. (2005). "Global Iron Connections Between Desert Dust, Ocean Biogeochemistry, and Climate". Science. 308 (5718): 67–71. Bibcode:2005Sci...308...67J. doi:10.1126/science.1105959. ISSN   0036-8075. PMID   15802595. S2CID   16985005.
  43. Giannini, Alessandra; Biasutti, Michela; Verstraete, Michel M. (2008). "A climate model-based review of drought in the Sahel: Desertification, the re-greening and climate change". Global and Planetary Change. Climate Change and Desertification. 64 (3): 119–128. Bibcode:2008GPC....64..119G. doi:10.1016/j.gloplacha.2008.05.004. ISSN   0921-8181.
  44. Breedveld, Peter C (2004). "Port-based modeling of mechatronic systems". Mathematics and Computers in Simulation. 66 (2): 99–128. CiteSeerX   10.1.1.108.9830 . doi:10.1016/j.matcom.2003.11.002.
  45. "Tierie, Gerrit. Cornelis Drebbel. Amsterdam: HJ Paris, 1932" (PDF). Retrieved 2013-05-03.
  46. Hills, Richard L (1996). Power From the Wind. Cambridge University Press. ISBN   9780521566865.
  47. Maxwell, James Clerk (1868). "On Governors" (PDF). Proceedings of the Royal Society of London. 16: 270–283. doi: 10.1098/rspl.1867.0055 . S2CID   51751195 via Wikimedia.
  48. Friis, H. T.; Jensen, A. G. (1924). "High Frequency Amplifiers". Bell System Technical Journal. 3 (2): 181–205. doi:10.1002/j.1538-7305.1924.tb01354.x.
  49. Black, H.S. (January 1934). "Stabilized Feedback Amplifiers" (PDF). Bell System Tech. J. 13 (1): 1–18. doi:10.1002/j.1538-7305.1934.tb00652.x . Retrieved January 2, 2013.
  50. 1 2 Stuart Bennett (1993). "Chapter 3: The electronic negative feedback amplifier". A history of control engineering 1930-1955. Institution of Electrical Engineers. pp. 70 ff. ISBN   9780863412806.
  51. C. Bissell (2006). "Karl Kupfmuller, 1928: an early time-domain, closed-loop, stability criterion" (PDF). IEEE Control Systems Magazine: 115–116, 126.
  52. Rosenblueth, Arturo, Norbert Wiener, and Julian Bigelow. "Behavior, purpose and teleology." Philosophy of science 10.1 (1943): 18-24.
  53. Norbert Wiener Cybernetics: Or Control and Communication in the Animal and the Machine . Cambridge, Massachusetts: The Technology Press; New York: John Wiley & Sons, Inc., 1948.
  54. Hermann A Haus and Richard B. Adler, Circuit Theory of Linear Noisy Networks, MIT Press, 1959
  55. Peter M. Senge (1990). The Fifth Discipline: The Art and Practice of the Learning Organization . New York: Doubleday. p. 424. ISBN   978-0-385-26094-7.
  56. Helen E. Allison; Richard J. Hobbs (2006). Science and Policy in Natural Resource Management: Understanding System Complexity. Cambridge University Press. p. 205. ISBN   9781139458603. Balancing or negative feedback counteracts and opposes change
  57. Carver, Charles S.; Scheier, Michael F. (2001-05-07). On the Self-Regulation of Behavior. ISBN   9780521000994.