Leak detection

Last updated

Pipeline leak detection is used to determine if (and in some cases where) a leak has occurred in systems which contain liquids and gases. Methods of detection include hydrostatic testing, tracer-gas leak testing, infrared, laser technology, and acoustic or sonar technologies. Some technologies are used only during initial pipeline installation and commissioning, while other technologies can be used for continuous monitoring during service.

Contents

Pipeline networks are a mode of transportation for oil, gases, and other fluid products. As a means of long-distance transport, pipelines have to fulfill high demands of safety, reliability and efficiency. If properly maintained, pipelines can last indefinitely without leaks. Some significant leaks that do occur are caused by damage from nearby excavation, but most leaks are caused by corrosion and equipment failure and incorrect operation. [1] If a pipeline is not properly maintained, it can corrode, particularly at construction joints, low points where moisture collects, or locations with imperfections in the pipe. Other reasons for leaks include exterior force damage (such as damage by car collisions or drilling rigs) and natural forces (such as earth movement, heavy rain and flooding, lightning, and temperature). [1]

Overview

The most common leak detection method for pipeline operators is called the Supervisory Control And Data Acquisition (SCADA) system. This system uses a series of sensors to track data such as pressure, flow rates, temperature, and whether valves are open or closed. The sensors relay the information to a control room where operators determine the legitimacy of the leak alarms. Some systems have added the Computational Pipeline Monitoring System (CPM), whose main task is to detect leaks. These systems have been reported by pipeline operators to the US Department of Transportation's Pipeline and Hazardous Materials Safety Administration to be inefficient in leak detection. Even with these in place, the SCADA system is reported to have detected only 19% of leaks, and the CPM system only detecting 10% of leaks. [2] [1]

The primary purpose of leak detection systems (LDS) is to help pipeline controllers to detect and localize leaks. LDS provide alarms and display other related data to the pipeline controllers to assist decision-making. Pipeline leak detection systems can also enhance productivity and system reliability thanks to reduced downtime and inspection time.

According to the API document "RP 1130", LDS are divided into internally based LDS and externally based LDS. Internally based systems use field instrumentation (for example flow, pressure or fluid temperature sensors) to monitor internal pipeline parameters. Externally based systems use a different, independent set of field instrumentation (for example infrared radiometers or thermal cameras, vapor sensors, acoustic microphones or fiber-optic cables) to monitor external pipeline parameters.

Rules and regulations

Some countries formally regulate pipeline operation.

API RP 1130 "Computational Pipeline Monitoring for Liquids" (US)

This recommended practice (RP) [3] focuses on the design, implementation, testing and operation of LDS that use an algorithmic approach. The purpose of this recommended practice is to assist the Pipeline Operator in identifying issues relevant to the selection, implementation, testing, and operation of an LDS.

TRFL (Germany)

TRFL is the abbreviation for "Technische Regel für Fernleitungsanlagen" (Technical Rule for Pipeline Systems). [4] The TRFL summarizes requirements for pipelines being subject of official regulations. It covers pipelines transporting flammable liquids, pipelines transporting liquids that are dangerous for water, and most of the pipelines transporting gas. Five different kinds of LDS or LDS functions are required:

Requirements

API 1155 [5] (replaced by API RP 1130 [3] ) defines the following important requirements for an LDS:

Steady-state and transient conditions

During steady-state conditions, the flow, pressures, etc. in the pipeline are (more or less) constant over time. During transient conditions, these variables may change rapidly. The changes propagate like waves through the pipeline with the speed of sound of the fluid. Transient conditions occur in a pipeline for example at start-up, if the pressure at inlet or outlet changes (even if the change is small), and when a batch changes, or when multiple products are in the pipeline. Gas pipelines are almost always in transient conditions, because gases are very compressible. Even in liquid pipelines, transient effects cannot be disregarded most of the time. LDS should allow for detection of leaks for both conditions to provide leak detection during the entire operating time of the pipeline.

Internally based LDS

Overview about internally based LDS. Overview Internally LDS.jpg
Overview about internally based LDS.

Internally based systems use field instrumentation (e.g. for flow, pressure and fluid temperature) to monitor internal pipeline parameters which are used to detect possible leaks. [3] System cost and complexity of internally based LDS are moderate because they use existing field instrumentation. This kind of LDS is used for standard safety requirements. [6]

Pressure/flow monitoring

A leak changes the hydraulics of the pipeline, and therefore changes the pressure or flow readings after some time. Local monitoring of pressure or flow at only one point can therefore provide simple leak detection. As it is done locally it requires in principle no telemetry. It is only useful in steady-state conditions, however, and its ability to deal with gas pipelines is limited. [7]

Acoustic pressure waves

The acoustic pressure wave method analyses the rarefaction waves produced when a leak occurs. When a pipeline wall breakdown occurs, fluid or gas escapes in the form of a high velocity jet. This produces negative pressure waves which propagate in both directions within the pipeline and can be detected and analyzed. The operating principles of the method are based on the very important characteristic of pressure waves to travel over long distances at the speed of sound guided by the pipeline walls. The amplitude of a pressure wave increases with the leak size. A complex mathematical algorithm analyzes data from pressure sensors and is able in a matter of seconds to point to the location of the leakage with accuracy less than 50 m (164 ft). Experimental data has shown the method's ability to detect leaks less than 3mm (0.1 inch) in diameter and operate with the lowest false alarm rate in the industry – less than 1 false alarm per year. [8]

However, the method is unable to detect an ongoing leak after the initial event: after the pipeline wall breakdown (or rupture), the initial pressure waves subside and no subsequent pressure waves are generated. Therefore, if the system fails to detect the leak (for instance, because the pressure waves were masked by transient pressure waves caused by an operational event such as a change in pumping pressure or valve switching), the system will not detect the ongoing leak.

Balancing methods

These methods base on the principle of conservation of mass. In the steady state, the mass flow entering a leak-free pipeline will balance the mass flow leaving it; any drop in mass leaving the pipeline (mass imbalance ) indicates a leak. Balancing methods measure and using flowmeters and finally compute the imbalance which is an estimate of the unknown, true leak flow. Comparing this imbalance (typically monitored over a number of periods) against a leak alarm threshold generates an alarm if this monitored imbalance. [7] Enhanced balancing methods additionally take into account the change rate of the mass inventory of the pipeline. Names that are used for enhanced line balancing techniques are volume balance, modified volume balance, and compensated mass balance. [3]

State-observer-based methods

These methods are based on state observers which are designed from fluid mathematical models expressed in state-space representation. These methods can be classified into two types: infinite-dimensional observers and finite-dimensional observers. The first type is based on a couple of quasi-linear hyperbolic partial differential equations: a momentum and a continuity equations that represent the fluid dynamics in a pipeline. The finite-dimensional observers are constructed from a lumped version of the momentum and a continuity equations. Several types of observers have been used for leak detection, for instance Kalman filters, [9] high gain observers, [10] [11] [12] sliding mode observers [13] and Luenberger-type observers. [14]

Statistical methods

Statistical LDS use statistical methods (e.g. from the field of decision theory) to analyse pressure/flow at only one point or the imbalance in order to detect a leak. [7] This leads to the opportunity to optimise the leak decision if some statistical assumptions hold. A common approach is the use of the hypothesis test procedure

This is a classical detection problem, and there are various solutions known from statistics. [15]

RTTM methods

RTTM means "Real-Time Transient Model". [7] RTTM LDS use mathematical models of the flow within a pipeline using basic physical laws such as conservation of mass, conservation of momentum, and conservation of energy. RTTM methods can be seen as an enhancement of balancing methods as they additionally use the conservation principle of momentum and energy. An RTTM makes it possible to calculate mass flow, pressure, density and temperature at every point along the pipeline in real-time with the help of mathematical algorithms. RTTM LDS can easily model steady-state and transient flow in a pipeline. Using RTTM technology, leaks can be detected during steady-state and transient conditions. With proper functioning instrumentation, leak rates may be functionally estimated using available formulas. [16]

E-RTTM methods

Signal flow Extended Real-Time Transient Model (E-RTTM). E-RTTM Method PC (Standard) SVG.svg
Signal flow Extended Real-Time Transient Model (E-RTTM).

E-RTTM [6] [7] stands for "Extended Real-Time Transient Model", using RTTM technology with statistical methods. So, leak detection is possible during steady-state and transient condition with high sensitivity, and false alarms will be avoided using statistical methods.

For the residual method, an RTTM module calculates estimates , for MASS FLOW at inlet and outlet, respectively. This can be done using measurements for pressure and temperature at inlet (, ) and outlet (, ). These estimated mass flows are compared with the measured mass flows , , yielding the residuals and . These residuals are close to zero if there is no leak; otherwise the residuals show a characteristic signature. In a next step, the residuals are subject of a leak signature analysis. This module analyses their temporal behaviour by extracting and comparing the leak signature with leak signatures in a database ("fingerprint"). Leak alarm is declared if the extracted leak signature matches the fingerprint.

Externally based LDS

Thermal camera system with video analysis software detecting an oil leak from a valve at 50 feet and 150 feet in heavy rain Diesel flange leak detection at150 ft and 50 ft in heavy rain with video analytics driven thermal camera system.jpg
Thermal camera system with video analysis software detecting an oil leak from a valve at 50 feet and 150 feet in heavy rain

Externally based systems use local, dedicated sensors. [3] Such LDS are highly sensitive and accurate, but system cost and complexity of installation are usually very high; [17] applications are therefore limited to special high-risk areas, e.g. near rivers or nature-protection areas. [6]

Analytic thermal leak detector for above ground pipelines

Video analytics driven thermal imaging using uncooled microbolometer infrared sensors is emerging as a new and effective method of visualizing, detecting and generating alerts of unplanned surface emissions of liquids and hydrocarbon gas liquids. [18] Detection to alarm generation takes less than 30 seconds. This technology is suitable for above-ground piping facilities, such as pump stations, refineries, storage sites, mines, chemical plants, water crossings, and water treatment plants. The need for new solutions in this area is driven by the fact that more than half of pipeline leaks occur at facilities. [19]

High quality thermographic technology accurately measures and visualizes emissivity or infrared radiation (thermal heat) of objects into gray scale imagery without the need for ambient lighting. The monitored petroleum product (e.g. oil) is distinguished from background objects by this heat difference. The addition of an analytic software component, typically optimizable to better address a specific application or environment, enables automated onsite leak analysis, validation and reporting, thereby reducing reliance on man power. A leak appearing within an analytic region (a rule added to the camera) is immediately analyzed for its attributes, including thermal temperature, size, and behaviour (e.g. spraying, pooling, spilling). When a leak is determined to be valid based on set parameters, an alarm notification with leak video is generated and sent to a monitoring station.

Optimal detection distance varies and is influenced by camera lens size, resolution, field of view, thermal detection range and sensitivity, leak size, and other factors. The system's layers of filters and immunity to environmental elements, such as snow, ice, rain, fog and glare, contribute to false alarms reduction. The video monitoring architecture can be integrated onto existing leak detection and repair (LDAR) systems, including SCADA networks, as well as other surveillance systems. [20]

Digital oil leak detection cable

Digital sense cables consist of a braid of semi-permeable internal conductors protected by a permeable insulating moulded braid. An electrical signal is passed through the internal conductors and is monitored by an inbuilt microprocessor inside the cable connector. Escaping fluids pass through the external permeable braid and make contact with the internal semi-permeable conductors. This causes a change in the electrical properties of the cable that is detected by the microprocessor. The microprocessor can locate the fluid to within a 1-metre resolution along its length and provide an appropriate signal to monitoring systems or operators. The sense cables can be wrapped around pipelines, buried sub-surface with pipelines or installed as a pipe-in-pipe configuration. [21]

Infrared radiometric pipeline testing

Aerial thermogram of buried cross country oil pipeline revealing subsurface contamination caused by a leak Leak Detection.jpg
Aerial thermogram of buried cross country oil pipeline revealing subsurface contamination caused by a leak

Infrared thermographic pipeline testing has shown itself to be both accurate and efficient in detecting and locating subsurface pipeline leaks, voids caused by erosion, deteriorated pipeline insulation, and poor backfill. When a pipeline leak has allowed a fluid, such as water, to form a plume near a pipeline, the fluid has a thermal conductance different from the dry soil or backfill. This will be reflected in different surface temperature patterns above the leak location. A high-resolution infrared radiometer allows entire areas to be scanned and the resulting data to be displayed as pictures with areas of differing temperatures designated by differing grey tones on a black & white image or by various colours on a colour image. This system measures surface energy patterns only, but the patterns that are measured on the surface of the ground above a buried pipeline can help show where pipeline leaks and resulting erosion voids are forming; it detects problems as deep as 30 meters below the ground surface. [22]

Acoustic emission detectors

Chris Cassidy works with an ultrasonic leak detector on the International Space Station Chris Cassidy works with a ultrasonic leak detector on ISS.jpg
Chris Cassidy works with an ultrasonic leak detector on the International Space Station

Escaping liquids create an acoustic signal as they pass through a hole in the pipe. Acoustic sensors affixed to the outside of the pipeline can create a baseline acoustic "fingerprint" of the line from the internal noise of the pipeline in its undamaged state. When a leak occurs, a resulting low-frequency acoustic signal is detected and analysed. Deviations from the baseline "fingerprint" signal an alarm. [6] [23] New sensors have improved frequency band selection, time delay range selection, etc. This makes the graphs more distinct and easy to analyse.

There are other ways to detect leakage, while reducing costs for exploratory excavation. Ground geo-phones with signal filtering are very useful to pinpoint leakage locations. An escaping pressurized water jet underground can create a faint noise which will be muffled on its way to the surface. Maximum signal can be picked up above the leakage position. Some types of gases escaping from a pipeline will create a range of sounds.

Apart from passive detection, active sonar-based methods for leak detection have been proposed, based on characteristic responses from multiphase bubbles and antibubbles. [24]

Vapour-sensing tubes

The vapour-sensing tube leak detection method involves the installation of a tube along the entire length of the pipeline. This tube – in cable form – is highly permeable to the substances to be detected in the particular application. If a leak occurs, the substances to be measured come into contact with the tube in the form of vapour, gas or dissolved in water. In the event of a leak, some of the leaking substance diffuses into the tube. After a certain period of time, the inside of the tube produces an accurate image of the substances surrounding the tube. In order to analyse the concentration distribution present in the sensor tube, a pump pushes the column of air in the tube past a detection unit at a constant speed. The detector unit at the end of the sensor tube is equipped with gas sensors. Every increase in gas concentration results in a pronounced "leak peak". [6] [25] [26]

Fibre-optic leak detection

At least two fibre-optic leak detection methods are being commercialized: Distributed Temperature Sensing (DTS) and Distributed Acoustic Sensing (DAS). The DTS method involves the installation of a fibre-optic cable along the length of pipeline being monitored. The substances to be measured come into contact with the cable when a leak occurs, changing the temperature of the cable and changing the reflection of the laser beam pulse, signalling a leak. The location is known by measuring the time delay between when the laser pulse was emitted and when the reflection is detected. This only works if the substance is at a temperature different from the ambient environment. In addition, the distributed fibre-optical temperature-sensing technique offers the possibility to measure temperature along the pipeline. Scanning the entire length of the fibre, the temperature profile along the fibre is determined, leading to leak detection. [6] [27]

The DAS method involves a similar installation of fiber-optic cable along the length of pipeline being monitored. Vibrations caused by a substance leaving the pipeline via a leak changes the reflection of the laser beam pulse, signaling a leak. The location is known by measuring the time delay between when the laser pulse was emitted and when the reflection is detected. This technique can also be combined with the Distributed Temperature Sensing method to provide a temperature profile of the pipeline.

Pipeline flyovers

Flyovers of the pipeline are frequently carried out to either confirm the location or to detect and locate small releases that cannot be identified by other methods. Typically the flyover of the right of way is recorded by video, which may have some image filtering, such as thermal imaging. Larger spills will typically be identified by a "sheen" in wetland or an area of dead vegetation around the release location.

Flyovers are typically scheduled and not recommended as a primary leak-detection method. They may be used to rapidly confirm the presence and location of a leak.

Biological leak detection

Biological methods of leak detection includes the use of dogs, which are more likely to be used once a release has been identified but not located due to its small size; or by landscapers who keep the pipeline right of way clear.

There are several companies who can provide dogs trained to identify the scent of release. Typically a technician injects a fluid into the pipeline that the scent dogs are trained to track. The dogs will then direct handlers towards a pipeline leak. They are trained to indicated at the strongest concentration therefore their pinpointing abilities can be typically within a meter. It typically takes 24 to 48 hours to mobilise a team, and may take several days to actually locate a release depending on the remoteness of the area.

Pipeline rights of way are kept clear by landscapers who are also trained to look for signs of pipeline releases. This is typically a scheduled process and should not be considered a primary form of leak detection.

See also

Related Research Articles

<span class="mw-page-title-main">Pressure measurement</span>

Pressure measurement is the measurement of an applied force by a fluid on a surface. Pressure is typically measured in units of force per unit of surface area. Many techniques have been developed for the measurement of pressure and vacuum. Instruments used to measure and display pressure mechanically are called pressure gauges,vacuum gauges or compound gauges. The widely used Bourdon gauge is a mechanical device, which both measures and indicates and is probably the best known type of gauge.

A viscometer is an instrument used to measure the viscosity of a fluid. For liquids with viscosities which vary with flow conditions, an instrument called a rheometer is used. Thus, a rheometer can be considered as a special type of viscometer. Viscometers can measure only constant viscosity, that is, viscosity that does not change with flow conditions.

<span class="mw-page-title-main">Pipeline</span> Pumping fluids or gas through pipes

A pipeline is a system of pipes for long-distance transportation of a liquid or gas, typically to a market area for consumption. The latest data from 2014 gives a total of slightly less than 2,175,000 miles (3,500,000 km) of pipeline in 120 countries around the world. The United States had 65%, Russia had 8%, and Canada had 3%, thus 76% of all pipeline were in these three countries. The main attribute to pollution from pipelines is caused by corrosion and leakage.

Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below:

<span class="mw-page-title-main">Time of flight</span> Timing of substance within a medium

Time of flight (ToF) is the measurement of the time taken by an object, particle or wave to travel a distance through a medium. This information can then be used to measure velocity or path length, or as a way to learn about the particle or medium's properties. The traveling object may be detected directly or indirectly. Time of flight technology has found valuable applications in the monitoring and characterization of material and biomaterials, hydrogels included.

<span class="mw-page-title-main">Hydrostatic test</span> Non-destructive test of pressure vessels

A hydrostatic test is a way in which pressure vessels such as pipelines, plumbing, gas cylinders, boilers and fuel tanks can be tested for strength and leaks. The test involves filling the vessel or pipe system with a liquid, usually water, which may be dyed to aid in visual leak detection, and pressurization of the vessel to the specified test pressure. Pressure tightness can be tested by shutting off the supply valve and observing whether there is a pressure loss. The location of a leak can be visually identified more easily if the water contains a colorant. Strength is usually tested by measuring permanent deformation of the container.

<span class="mw-page-title-main">Water hammer</span> Pressure surge when a fluid is forced to stop or change direction suddenly

Hydraulic shock is a pressure surge or wave caused when a fluid in motion is forced to stop or change direction suddenly: a momentum change. It is usually observed in a liquid but gases can also be affected. This phenomenon commonly occurs when a valve closes suddenly at an end of a pipeline system and a pressure wave propagates in the pipe.

In electrical engineering, partial discharge (PD) is a localized dielectric breakdown (DB) of a small portion of a solid or fluid electrical insulation (EI) system under high voltage (HV) stress. While a corona discharge (CD) is usually revealed by a relatively steady glow or brush discharge (BD) in air, partial discharges within solid insulation system are not visible.

<span class="mw-page-title-main">Pigging</span> Practice of using pipeline inspection gauges or gadgets to perform various maintenance operations

In pipeline transportation, pigging is the practice of using pipeline inspection gauges or gadgets, devices generally referred to as pigs or scrapers, to perform various maintenance operations. This is done without stopping the flow of the product in the pipeline.

A wet gas is any gas with a small amount of liquid present. The term "wet gas" has been used to describe a range of conditions varying from a humid gas which is gas saturated with liquid vapour to a multiphase flow with a 90% volume of gas. There has been some debate as to its actual definition, and there is currently no fully defined quantitative definition of a wet gas flow that is universally accepted.

A leak is a way for fluid to escape a container or fluid-containing system, such as a tank or a ship's hull, through which the contents of the container can escape or outside matter can enter the container. Leaks are usually unintended and therefore undesired. The word leak usually refers to a gradual loss; a sudden loss is usually called a spill.

Level sensors detect the level of liquids and other fluids and fluidized solids, including slurries, granular materials, and powders that exhibit an upper free surface. Substances that flow become essentially horizontal in their containers because of gravity whereas most bulk solids pile at an angle of repose to a peak. The substance to be measured can be inside a container or can be in its natural form. The level measurement can be either continuous or point values. Continuous level sensors measure level within a specified range and determine the exact amount of substance in a certain place, while point-level sensors only indicate whether the substance is above or below the sensing point. Generally the latter detect levels that are excessively high or low.

A gas detector is a device that detects the presence of gases in an area, often as part of a safety system. A gas detector can sound an alarm to operators in the area where the leak is occurring, giving them the opportunity to leave. This type of device is important because there are many gases that can be harmful to organic life, such as humans or animals.

There are a number of possible ways to measure thermal conductivity, each of them suitable for a limited range of materials, depending on the thermal properties and the medium temperature. Three classes of methods exist to measure the thermal conductivity of a sample: steady-state, time-domain, and frequency-domain methods.

<span class="mw-page-title-main">Infrared and thermal testing</span>

Infrared and thermal testing refer to passive thermographic inspection techniques, a class of nondestructive testing designated by the American Society for Nondestructive Testing (ASNT). Infrared thermography is the science of measuring and mapping surface temperatures.

"Infrared thermography, a nondestructive, remote sensing technique, has proved to be an effective, convenient, and economical method of testing concrete. It can detect internal voids, delaminations, and cracks in concrete structures such as bridge decks, highway pavements, garage floors, parking lot pavements, and building walls. As a testing technique, some of its most important qualities are that (1) it is accurate; (2) it is repeatable; (3) it need not inconvenience the public; and (4) it is economical."

The Glossary of fuel cell terms lists the definitions of many terms used within the fuel cell industry. The terms in this fuel cell glossary may be used by fuel cell industry associations, in education material and fuel cell codes and standards to name but a few.

<span class="mw-page-title-main">Instrumentation in petrochemical industries</span>

Instrumentation is used to monitor and control the process plant in the oil, gas and petrochemical industries. Instrumentation ensures that the plant operates within defined parameters to produce materials of consistent quality and within the required specifications. It also ensures that the plant is operated safely and acts to correct out of tolerance operation and to automatically shut down the plant to prevent hazardous conditions from occurring. Instrumentation comprises sensor elements, signal transmitters, controllers, indicators and alarms, actuated valves, logic circuits and operator interfaces.

<span class="mw-page-title-main">Rebreather diving</span> Underwater diving using self contained breathing gas recycling apparatus

Rebreather diving is underwater diving using diving rebreathers, a class of underwater breathing apparatus which recirculate the breathing gas exhaled by the diver after replacing the oxygen used and removing the carbon dioxide metabolic product. Rebreather diving is practiced by recreational, military and scientific divers in applications where it has advantages over open circuit scuba, and surface supply of breathing gas is impracticable. The main advantages of rebreather diving are extended gas endurance, low noise levels, and lack of bubbles.

<span class="mw-page-title-main">Three-dimensional electrical capacitance tomography</span> 3D imaging technology

Three-dimensional electrical capacitance tomography also known as electrical capacitance volume tomography (ECVT) is a non-invasive 3D imaging technology applied primarily to multiphase flows. It was introduced in the early 2000s as an extension of the conventional two-dimensional ECT. In conventional electrical capacitance tomography, sensor plates are distributed around a surface of interest. Measured capacitance between plate combinations is used to reconstruct 2D images (tomograms) of material distribution. Because the ECT sensor plates are required to have lengths on the order of the domain cross-section, 2D ECT does not provide the required resolution in the axial dimension. In ECT, the fringing field from the edges of the plates is viewed as a source of distortion to the final reconstructed image and is thus mitigated by guard electrodes. 3D ECT exploits this fringing field and expands it through 3D sensor designs that deliberately establish an electric field variation in all three dimensions. In 3D tomography, the data are acquired in 3D geometry, and the reconstruction algorithm produces the three-dimensional image directly, in contrast to 2D tomography, where 3D information might be obtained by stacking 2D slices reconstructed individually.

Tank leak detection is implemented to alert the operator to a suspected release from any part of a storage tank system, what enables to prevent from soil contamination and loss of product.

References

  1. 1 2 3 "Distribution, Transmission & Gathering, LNG, and Liquid Accident and Incident Data | PHMSA". www.phmsa.dot.gov.
  2. "Technology designed to detect U.S. energy pipeline leaks often fails". Reuters. September 30, 2016 via www.reuters.com.
  3. 1 2 3 4 5 API RP 1130 (2007): Computational Pipeline Monitoring for Liquids. 1st Edition (September 2007). American Petroleum Institute.
  4. TRFL (2003): Technische Regel für Fernleitungen (Technical Rule For Pipelines).
  5. API 1155 (1995): Evaluation Methodology for Software Based Leak Detection Systems. 1st Edition (February 1995). American Petroleum Institute. Replaced by API RP 1130.
  6. 1 2 3 4 5 6 Geiger, G., Werner, T., Matko, D. (2003): Leak Detection and Locating – A Survey. 35th Annual PSIG Meeting, 15–17 October 2003, Bern, Switzerland.
  7. 1 2 3 4 5 Geiger, G. (2008): Principles of Leak Detection. 1st Edition (September 2008). Krohne Oil & Gas, Breda (The Netherlands).
  8. Avateq Corp. Press Release. New Leak Detection and Monitoring Technology Ensures Safety of Pipelines.
  9. Benkherouf, A., & Allidina, A. Y. (1986). Leak Detection Methods for Gas Pipelines. IFAC Proceedings Volumes, 19(6), 205–210.
  10. Torres, L., Verde, C., Besancon, G., & González, O. (2014). High‐gain observers for leak location in subterranean pipelines of liquefied petroleum gas. International Journal of Robust and Nonlinear Control, 24(6), 1127–1141.
  11. Torres, L., Besançon, G., Navarro, A., Begovich, O., & Georges, D. (2011, March). Examples of pipeline monitoring with nonlinear observers and real-data validation. In 8th IEEE International Multi-Conf on Signals Systems and Devices, Sousse, Tunisia.
  12. Torres, L. (2011). Modèles et observateurs pour les systèmes d'écoulement sous pression. Extension aux systèmes chaotiques (Doctoral dissertation, Grenoble).
  13. Negrete, M. A., & Verde, C. (2012). Multi-leak reconstruction in pipelines by sliding mode observers. IFAC Proceedings Volumes, 45(20), 934–939.
  14. Hauge, E., Aamo, O. M., & Godhavn, J. M. (2007). Model based pipeline monitoring with leak detection. IFAC Proceedings Volumes, 40(12), 318–323.
  15. Berger, J.O. (1985): Statistical Decision Theory and Bayesian Analysis. Springer Series in Statistics. 2nd Edition (1985).
  16. "Leak Rate Calculator | Discover Unknown Leak Test Values". www.cincinnati-test.com.
  17. Leak Detection and Locating – A Survey by Gerhard Geiger, University of Applied Sciences Gelsenkirchen, Faculty of Electrical Engineering "Archived copy" (PDF). Archived from the original (PDF) on 2015-11-29. Retrieved 2014-12-08.{{cite web}}: CS1 maint: archived copy as title (link)
  18. CEPA (November 20, 2015). "The Inside Story on Pipeline Leak Detection". Canadian Energy Pipeline Association. Retrieved March 21, 2017.
  19. API (October 2009). "PPTS Operator Advisory: New Findings on Releases from Facilities Piping" (PDF). American Petroleum Institute. Retrieved March 21, 2017.
  20. "New technology allows workers to control oil wells with their smartphones". The Globe and Mail. Retrieved 2017-03-24.
  21. TTK S.A.S. Liquid Hydrocarbon and Non-Conductive Solvent Sense Cable http://www.ttkuk.com/oil-leak-detection/products/sense-cable/hydrocarbon-sense-cables/fg-od/
  22. Jackson, C.N.; Sherlock, C.N. (1998): Non-destructive Testing Handbook: Leak Testing, page 519, Library of Congress Cataloging-in-Publication Data, 2008.
  23. Fuchs, H. V. (1991): Ten Year of Experience with Leak Detection by Acoustic Signal Analysis. Applied Acoustics 33 (1991), p. 1-19.
  24. Johansen K, Kotopoulis S, Postema M (2015). "Ultrasonically driven antibubbles encapsulated by Newtonian fluids for active leakage detection". Lecture Notes in Engineering and Computer Science. 2216: 750–754.
  25. "Leakage detection and localization system – LEOS".
  26. "Technical Review of Leak Detection Technologies – Alaska Department of Environmental Conservation" (PDF).
  27. Großwig, S. et al. (2001): Distributed Fiber Optical Temperature Sensing Technique – A Variable Tool for Monitoring Tasks. Proceedings of the 8th International Symposium on Temperature and Thermal Measurements in Industry and Science, June 19 – 21, 2001.