Water metering is the practice of measuring water use. Water meters measure the volume of water used by residential and commercial building units that are supplied with water by a public water supply system. They are also used to determine flow through a particular portion of the system.

Contents

In most of the world water meters are calibrated in cubic metres (m3) or litres, [1] but in the United States and some other countries water meters are calibrated in cubic feet (ft3) or US gallons on a mechanical or electronic register. Modern meters typically can display rate-of-flow in addition to total volume.

Several types of water meters are in common use, and may be characterized by the flow measurement method, the type of end-user, the required flow rates, and accuracy requirements.

In North America, standards for manufacturing water meters are set by the American Water Works Association. Outside of North America, most countries use ISO standards.

Types of metering devices

There are two common approaches to flow measurement: displacement and velocity, each making use of a variety of technologies. Common displacement designs include oscillating piston and nutating disc meters. Velocity-based designs include single- and multi-jet meters and turbine meters.

There are also non-mechanical designs, for example, electromagnetic and ultrasonic meters, and meters designed for special uses. Most meters in a typical water distribution system are designed to measure cold potable water only. Specialty hot water meters are designed with materials that can withstand higher temperatures. Meters for reclaimed water have special lavender register covers to signify that the water should not be used for drinking.

Additionally, there are electromechanical meters, like prepaid water meters and automatic meter reading meters. The latter integrates an electronic measurement component and a LCD with a mechanical water meter. Mechanical water meters normally use a reed switch, hall or photoelectric coding register as the signal output. After processing by the microcontroller unit (MCU) in the electronic module, the data are transmitted to the LCD or output to an information management system.

Water meters are generally owned, read and maintained by a public water provider such as a city, rural water association or private water company. In some cases an owner of a mobile home park, apartment complex or commercial building may be billed by a utility based on the reading of one meter, with the costs shared among the tenants based on some sort of key (size of flat, number of inhabitants or by separately tracking the water consumption of each unit in what is called submetering).

Displacement water meters

Water meter in Belo Horizonte Hidrometro.JPG
Water meter in Belo Horizonte

Displacement meters are commonly referred to as Positive Displacement, or "PD" meters. Two common types are oscillating piston meters and nutating disk meters. Either method relies on the water to physically displace the moving measuring element in direct proportion to the amount of water that passes through the meter. The piston or disk moves a magnet that drives the register.

PD meters are generally very accurate at the low-to-moderate flow rates typical of residential and small commercial users and commonly range in size from 5/8" to 2". Because displacement meters require that all water flows through the meter to "push" the measuring element, they generally are not practical in large commercial applications requiring high flow rates or low-pressure loss. PD meters normally have a built-in strainer to protect the measuring element from rocks or other debris that could stop or break the measuring element. PD meters normally have bronze, brass or plastic bodies with internal measuring chambers made of moulded plastics and stainless steel.

Velocity water meters

A velocity water meter Su sayaci-0101.jpg
A velocity water meter
Internal structure of a velocity water meter Su sayaci-0103.jpg
Internal structure of a velocity water meter

A velocity-type meter measures the velocity of flow through a meter of known internal capacity. The speed of the flow can then be converted into a volume of flow to determine the usage. There are several types of meters that measure water flow velocity, including jet meters (single-jet and multi-jet), turbine meters, propeller meters and mag meters. Most velocity-based meters have an adjustment vane for calibrating the meter to the required accuracy.

Multi-jet meters

Multi-jet meters are very accurate in small sizes and are commonly used in 58 in (16 mm) to 2 in (51 mm) sizes for residential and small commercial users. Multi-jet meters use multiple ports surrounding an internal chamber to create multiple jets of water against a turbine, whose rotation speed depends on the velocity of water flow. Multi-jets are very accurate at low flow rates, but there are no large size meters since they do not have the straight-through flow path needed for the high flow rates used in large pipe diameters. Multi-jet meters generally have an internal strainer element that can protect the jet ports from getting clogged. Multi-jet meters normally have bronze alloy bodies or outer casings, with internal measuring parts made from modern thermoplastics and stainless steel.

Turbine meters

Turbine meters are less accurate than displacement and jet meters at low flow rates, but the measuring element does not occupy or severely restrict the entire path of flow. The flow direction is generally straight through the meter, allowing for higher flow rates and less pressure loss than displacement-type meters. They are the meter of choice for large commercial users, fire protection and as master meters for the water distribution system. Strainers are generally required to be installed in front of the meter to protect the measuring element from gravel or other debris that could enter the water distribution system. Turbine meters are generally available for 1+12 in (38 mm) to 12 in (300 mm) or higher pipe sizes. Turbine meter bodies are commonly made of bronze, cast iron or ductile iron. Internal turbine elements can be plastic or non-corrosive metal alloys. They are accurate in normal working conditions but are greatly affected by the flow profile and fluid conditions.

  • Fire meters are a specialized type of turbine meter meeting the high flow rates requirements for fire protection. They are often approved by Underwriters Laboratories (UL) or Factory Mutual (FM) for use in fire protection.
  • Fire hydrant meters are a specialized type of portable turbine meter attached to a fire hydrant to measure water flowing out of the hydrant. The meters are normally made of aluminium to keep their weight low and usually have a 3 in (76 mm) capacity. Utilities often require them for measuring water used on construction sites, for pool filling, or where a permanent meter has not yet been installed.

Compound meters

A compound meter is used where high flow rates are necessary, but where at times there are also smaller rates of flow that need to be accurately measured. Compound meters have two measuring elements and a check valve to regulate flow between them. At high flow rates, water is normally diverted primarily or completely to the high flow element. The high flow element is typically a turbine meter. When flow rates drop to where the high flow element cannot measure accurately, a check valve closes to divert water to a smaller element that can measure the lower flow rates accurately. The low flow element is typically a multi-jet or PD meter. By adding the values registered by the high and low elements, the utility has a record of the total consumption of water flowing through the meter.

Electromagnetic meters

Electromagnetic flow meter Tetley's brewery, Leeds (10th May 2010) 008.jpg
Electromagnetic flow meter

Magnetic flow meters, commonly referred to as "mag meters", are technically a velocity-type water meter, except that they use electromagnetic properties to determine the water flow velocity, rather than the mechanical means used by jet and turbine meters. Mag meters use the physics principle of Faraday's law of induction for measurement and require AC or DC electricity from a power line or battery to operate the electromagnets. Since mag meters have no mechanical measuring element, they normally have the advantage of being able to measure flow in either direction, and use electronics for measuring and totalizing the flow. Mag meters can also be useful for measuring raw (untreated/unfiltered) water and waste-water since there is no mechanical measuring element to get clogged or damaged by debris flowing through the meter. Strainers are not required with mag meters since there is no measuring element in the stream of flow that could be damaged. Since stray electrical energy flowing through the flow tube can cause inaccurate readings, most mag meters are installed with either grounding rings or grounding electrodes to divert stray electricity away from the electrodes used to measure the flow inside the flow tube.

Ultrasonic meters

Ultrasonic water meters use one or more ultrasonic transducer to send ultrasonic sound waves through the fluid to determine the velocity of the water. Since the cross-sectional area of the meter body is a fixed and known value, when the velocity of water is detected, the volume of water passing through the meter can be calculated with very high accuracy. Because of water density changes with temperature, most ultrasonic water meters also measure the water temperature as a component of the volume calculation.

There are 2 primary ultrasonic measurement technologies used in water metering:

Ultrasonic meters may either be of flow-through or "clamp-on" design. Flow-through designs are those where the water passes directly through the meter, and are typically found in residential or commercial applications. Clamp-on designs are generally used for larger diameters where the sensors are mounted to the exterior of pipes, etc.

Ultrasonic water meters are typically very accurate (if built in)[ clarification needed ], with residential meters capable of measuring down to 0.01 gallons or 0.001 cubic feet. In addition, they have wide flow measurement ranges, require little maintenance and have long lifespans due to the lack of internal mechanical components to wear out. While relatively new to the American water utility market, ultrasonic meters have been used in commercial applications for many years and are becoming widely accepted due to their advantages over traditional mechanical designs.

Prepaid water meters

Meters can be prepaid or postpaid, depending on the payment method. Most mechanical type water meters are of the postpaid type, as are electromagnetic and ultrasonic meters. With prepaid water meters, the user purchases and prepays for a given amount of water from a vending station. The amount of water credited is entered on media such as an IC or RF type card. The main difference is whether the card needs contact with the processing part of the prepaid water meter. In some areas, a prepaid water meter uses a keypad as the interface for inputting the water credit.

Registers

A typical water meter register showing a meter reading of 8.3 gallons. Notice the black "1" on the odometer has not yet fully turned over, so only the red hand is read. Water meter register.jpg
A typical water meter register showing a meter reading of 8.3 gallons. Notice the black "1" on the odometer has not yet fully turned over, so only the red hand is read.
Water meters connected to remote reading devices through three-wire cables Water meter with remote reading.jpg
Water meters connected to remote reading devices through three-wire cables

There are several types of registers on water meters. A standard register normally has a dial similar to a clock, with gradations around the perimeter to indicate the measuring unit and the amount of water used, if less than the lowest digit in a display similar to the odometer wheels in a car, their sum is the total volume used. Modern registers are normally driven by a magnetic coupling between a magnet in the measuring chamber attached to the measuring element and another attached to the bottom of the register. Gears in the register convert the motion of the measuring element to the proper usage increment for display on the sweep hand and the odometer-style wheels. Many registers also have a leak detector. This is a small visible disk or hand that is geared closer to the rotation speed of the drive magnet, so that very small flows that would be visually undetectable on the regular sweep hand can be seen.

With Automatic Meter Reading, manufacturers have developed pulse or encoder registers to produce electronic output for radio transmitters, reading storage devices, and data logging devices. Pulse meters send a digital or analog electronic pulse to a recording device. Encoder registers have an electronic means permitting an external device to interrogate the register to obtain either the position of the wheels or a stored electronic reading. Frequent transmissions of consumption data can be used to give smart meter functionality.

There are also some specialized types of registers such as meters with an LCD instead of mechanical wheels, and registers to output data or pulses to a variety of recording and controller devices. For industrial applications, the output is often 4-20 mA analog for recording or controlling different flow rates in addition to totalization.

Water meter reading

Different size meters indicate different resolutions of the reading. One rotation of the sweep hand may be equivalent to 10 gallons or to 1,000 gallons (1 to 100 ft3, 0.1 to 10 m3). If one rotation of the hand represents 10 gallons, the meter has a 10-gallon sweep. Sometimes the last number(s) of the wheel display are non-rotating or printed on the dial face. The fixed zero number(s) are represented by the position of the rotating sweep hand. For example, if one rotation of the hand is 10 gallons, the sweep hand is on 7, and the wheel display shows 123456 plus a fixed zero, the actual total usage would be 1,234,567 gallons.

In the United States most utilities bill only to the nearest 100 or 1,000 gallons (10 to 100 ft3, 1 to 10 m3), and often only read the leftmost 4 or 5 numbers on the display wheels. Using the above example, they would read and bill 1,234, rounding to 1,234,000 gallons based on a 1,000-gallon billing resolution. The most common rounding for a particular size meter is often indicated by differently coloured number wheels, the ones ignored being black, and the ones used for billing being white.

Prevalence

Bank of water meters in building Water meter in building .jpg
Bank of water meters in building

Water metering is common for residential and commercial drinking water supply in many countries, as well as for industrial self-supply with water. However, it is less common in irrigated agriculture, which is the major water user worldwide. Water metering is also uncommon for piped drinking water supply in rural areas and small towns, although there are examples of successful metering in rural areas in developing countries, such as in El Salvador. [2]

Metering of water supplied by utilities to residential, commercial and industrial users is common in most developed countries, except for the United Kingdom where only about 52% of users are metered. [3] In some developing countries metering is very common, such as in Chile where it stands at 96%, while in others it still remains low, such as in Argentina.

The percentage of residential water metering in selected cities in developing countries is as follows: [4]

Nearly two-thirds of OECD countries meter more than 90% of single-family houses. A few are also expanding their metering of apartments (e.g., France and Germany). [5]

Benefits

The benefits of metering are that:

Costs

The costs of metering include:

While the cost of purchasing residential meters is low, the total life cycle costs of metering are high. For example, retrofitting flats in large buildings with meters for every flat can involve major and thus costly plumbing work. [6]

Problems

Problems associated with metering arise particularly in the case of intermittent supply, which is common in many developing countries. Sudden changes in pressure can damage meters to the extent that many meters in cities in developing countries are not functional. Also, some types of meters become less accurate as they age, and under-registering consumption leads to lower revenues if defective meters are not regularly replaced. Many types of meters also register air flows, which can lead to over-registration of consumption, [7] especially in systems with intermittent supply, when water supply is re-established and the incoming water pushes air through the meters.

Water meters do not distinguish between air and water, both are counted as fluid. There are two regulations where water companies and meter manufacturers do not comply and charge air for water. A measuring system shall be equipped with an effective air/vapor eliminator or other automatic means to prevent the passage of air/vapor through the meter. ref.[Handbook 44 – 2019 3.30. S.2.1.][ specify ] Measuring systems shall incorporate a gas elimination device for the proper elimination of any air or undissolved gases which may be contained in the liquid before it enters the meter. [8] [9] [ failed verification ]

Effect on consumption

There is disagreement as to the effect of metering and water pricing on water consumption. The price elasticity of metered water demand varies greatly depending on local conditions. The effect of volumetric water pricing on consumption tends to be higher if the water bill represents a significant portion of household expenditures.

There is evidence from the UK that there is an instant drop in consumption of some 10% when meters are installed, although in most instances consumption is not directly measured prior to meter installation, so the benefits are uncertain. [6] Whilst metered water users in the UK do use less than unmetered users, in most areas metering is not compulsory for homes built before 1990, [10] so the metered customers are to some extent a self-selecting group. There is also concern that water metering could be socially regressive, as householders on low incomes are less able to invest in water efficiency measures and may experience water poverty (defined as when a household spends more than 3% of net income on water and sewage services). [11]

In Hamburg, Germany, domestic water consumption for metered flats (112 liter/capita/day) was 18% lower than for unmetered flats (137 liter/capita/day) in 1992.

See also

Related Research Articles

<span class="mw-page-title-main">Anemometer</span> Instrument for measuring wind speed

In meteorology, an anemometer is a device that measures wind speed and direction. It is a common instrument used in weather stations. The earliest known description of an anemometer was by Italian architect and author Leon Battista Alberti (1404–1472) in 1450.

<span class="mw-page-title-main">Pressure measurement</span> Analysis of force applied by a fluid on a surface

Pressure measurement is the measurement of an applied force by a fluid on a surface. Pressure is typically measured in units of force per unit of surface area. Many techniques have been developed for the measurement of pressure and vacuum. Instruments used to measure and display pressure mechanically are called pressure gauges,vacuum gauges or compound gauges. The widely used Bourdon gauge is a mechanical device, which both measures and indicates and is probably the best known type of gauge.

<span class="mw-page-title-main">Pump</span> Device that imparts energy to the fluids by mechanical action

A pump is a device that moves fluids, or sometimes slurries, by mechanical action, typically converted from electrical energy into hydraulic energy.

<span class="mw-page-title-main">Pelton wheel</span> Type of turbine

The Pelton wheel or Pelton Turbine is an impulse-type water turbine invented by American inventor Lester Allan Pelton in the 1870s. The Pelton wheel extracts energy from the impulse of moving water, as opposed to water's dead weight like the traditional overshot water wheel. Many earlier variations of impulse turbines existed, but they were less efficient than Pelton's design. Water leaving those wheels typically still had high speed, carrying away much of the dynamic energy brought to the wheels. Pelton's paddle geometry was designed so that when the rim ran at half the speed of the water jet, the water left the wheel with very little speed; thus his design extracted almost all of the water's impulse energy—which made for a very efficient turbine.

<span class="mw-page-title-main">Water turbine</span> Type of turbine

A water turbine is a rotary machine that converts kinetic energy and potential energy of water into mechanical work.

<span class="mw-page-title-main">Wind speed</span> Rate at which air moves from high- to low-pressure areas

In meteorology, wind speed, or wind flow speed, is a fundamental atmospheric quantity caused by air moving from high to low pressure, usually due to changes in temperature. Wind speed is now commonly measured with an anemometer.

Flow measurement is the quantification of bulk fluid movement. Flow can be measured using devices called flowmeters in various ways. The common types of flowmeters with industrial applications are listed below:

<span class="mw-page-title-main">Automatic meter reading</span> Transmitting consumption data from a utility meter to the utility provider

Automatic meter reading (AMR) is the technology of automatically collecting consumption, diagnostic, and status data from water meter or energy metering devices and transferring that data to a central database for billing, troubleshooting, and analyzing. This technology mainly saves utility providers the expense of periodic trips to each physical location to read a meter. Another advantage is that billing can be based on near real-time consumption rather than on estimates based on past or predicted consumption. This timely information coupled with analysis can help both utility providers and customers better control the use and production of electric energy, gas usage, or water consumption.

<span class="mw-page-title-main">Electricity meter</span> Device used to measure electricity use

An electricity meter, electric meter, electrical meter, energy meter, or kilowatt-hour meter is a device that measures the amount of electric energy consumed by a residence, a business, or an electrically powered device.

<span class="mw-page-title-main">Gas meter</span> Flow meter for fuel gases

A gas meter is a specialized flow meter, used to measure the volume of fuel gases such as natural gas and liquefied petroleum gas. Gas meters are used at residential, commercial, and industrial buildings that consume fuel gas supplied by a gas utility. Gases are more difficult to measure than liquids, because measured volumes are highly affected by temperature and pressure. Gas meters measure a defined volume, regardless of the pressurized quantity or quality of the gas flowing through the meter. Temperature, pressure, and heating value compensation must be made to measure actual amount and value of gas moving through a meter.

<span class="mw-page-title-main">Turbomachinery</span> Machine for exchanging energy with a fluid

Turbomachinery, in mechanical engineering, describes machines that transfer energy between a rotor and a fluid, including both turbines and compressors. While a turbine transfers energy from a fluid to a rotor, a compressor transfers energy from a rotor to a fluid. It is an important application of fluid mechanics.

<span class="mw-page-title-main">Ultrasonic flow meter</span> Flow meter using ultrasound

An ultrasonic flow meter is a type of flow meter that measures the velocity of a fluid with ultrasound to calculate volume flow. Using ultrasonic transducers, the flow meter can measure the average velocity along the path of an emitted beam of ultrasound, by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow or by measuring the frequency shift from the Doppler effect. Ultrasonic flow meters are affected by the acoustic properties of the fluid and can be impacted by temperature, density, viscosity and suspended particulates depending on the exact flow meter. They vary greatly in purchase price but are often inexpensive to use and maintain because they do not use moving parts, unlike mechanical flow meters.

Condition monitoring is the process of monitoring a parameter of condition in machinery, in order to identify a significant change which is indicative of a developing fault. It is a major component of predictive maintenance. The use of condition monitoring allows maintenance to be scheduled, or other actions to be taken to prevent consequential damages and avoid its consequences. Condition monitoring has a unique benefit in that conditions that would shorten normal lifespan can be addressed before they develop into a major failure. Condition monitoring techniques are normally used on rotating equipment, auxiliary systems and other machinery like belt-driven equipment,, while periodic inspection using non-destructive testing (NDT) techniques and fit for service (FFS) evaluation are used for static plant equipment such as steam boilers, piping and heat exchangers.

A wet gas is any gas with a small amount of liquid present. The term "wet gas" has been used to describe a range of conditions varying from a humid gas which is gas saturated with liquid vapour to a multiphase flow with a 90% volume of gas. There has been some debate as to its actual definition, and there is currently no fully defined quantitative definition of a wet gas flow that is universally accepted.

Level sensors detect the level of liquids and other fluids and fluidized solids, including slurries, granular materials, and powders that exhibit an upper free surface. Substances that flow become essentially horizontal in their containers because of gravity whereas most bulk solids pile at an angle of repose to a peak. The substance to be measured can be inside a container or can be in its natural form. The level measurement can be either continuous or point values. Continuous level sensors measure level within a specified range and determine the exact amount of substance in a certain place, while point-level sensors only indicate whether the substance is above or below the sensing point. Generally the latter detect levels that are excessively high or low.

<span class="mw-page-title-main">Air flow bench</span> Device for testing internal aerodynamics of engine parts

An air flow bench is a device used for testing the internal aerodynamic qualities of an engine component and is related to the more familiar wind tunnel.

<span class="mw-page-title-main">Positive displacement meter</span>

A positive displacement meter is a type of flow meter that requires fluid to mechanically displace components in the meter in order for flow measurement. Positive displacement (PD) flow meters measure the volumetric flow rate of a moving fluid or gas by dividing the media into fixed, metered volumes. A basic analogy would be holding a bucket below a tap, filling it to a set level, then quickly replacing it with another bucket and timing the rate at which the buckets are filled. With appropriate pressure and temperature compensation, the mass flow rate can be accurately determined.

<span class="mw-page-title-main">Custody transfer</span> Oil and gas industry term for transfer of physical substance from one operator to another

Custody Transfer in the oil and gas industry refers to the transactions involving transporting physical substance from one operator to another. This includes the transferring of raw and refined petroleum between tanks and railway tank cars; onto ships, and other transactions. Custody transfer in fluid measurement is defined as a metering point (location) where the fluid is being measured for sale from one party to another. During custody transfer, accuracy is of great importance to both the company delivering the material and the eventual recipient, when transferring a material.

<span class="mw-page-title-main">Heat meter</span> Measuring device for thermal energy

A heat meter, thermal energy meter or energy meter is a device which measures thermal energy provided by a source or delivered to a sink, by measuring the flow rate of the heat transfer fluid and the change in its temperature (ΔT) between the outflow and return legs of the system. It is typically used in industrial plants for measuring boiler output and heat taken by process, and for district heating systems to measure the heat delivered to consumers.

Flow conditioning ensures that the "real world" environment closely resembles the "laboratory" environment for proper performance of inferential flowmeters like orifice, turbine, coriolis, ultrasonic etc.

References

  1. "Ofwat UK - Water meters - your questions answered" (PDF). ofwat.gov.uk. Retrieved 5 April 2018.
  2. Water and Sanitation Program Field Note: Micro-metering in rural areas: A success story from El Salvador, 2003 (in Spanish) PAS
  3. "Water conservation report" (PDF). DEFRA. December 2018.
  4. World Bank: Water, Electricity and the Poor, p. 78 WB
  5. OECD:The Price of Water: Trends in OECD countries, 1999, accessed on 21 January 2010
  6. 1 2 Lis Stedman: Motivations for metering, Water 21, The Magazine of the International Water Association, April 2006, p. 26-28
  7. Walters, David (2012). Experimentelle Untersuchung der Genauigkeit von Hauswasserzählern bei intermittierender Wasserversorgung (M. Sc.). Karlsruher Institut für Technologie (KIT).
  8. "R 117-3 Edition 2014". INTERNATIONAL ORGANIZATION OF LEGAL METROLOGY. Retrieved July 5, 2020.
  9. "R 117-1 Section: 2.10.1 Elimination of air or gases" (PDF). INTERNATIONAL ORGANIZATION OF LEGAL METROLOGY. Retrieved July 5, 2020.
  10. "Why is there a water meter at my new property?". United Utilities Group PLC. Retrieved 9 February 2022.
  11. "Water poverty set to soar | Poverty and Social Exclusion". www.poverty.ac.uk. Retrieved 2017-03-08.

Further reading