Magnetorheological fluid

Last updated
Schematic of a magnetorheological fluid solidifying and blocking a pipe in response to an external magnetic field. (Animated version available.) MRF-Effekt-static-crop.png
Schematic of a magnetorheological fluid solidifying and blocking a pipe in response to an external magnetic field. (Animated version available.)

A magnetorheological fluid (MR fluid, or MRF) is a type of smart fluid in a carrier fluid, usually a type of oil. When subjected to a magnetic field, the fluid greatly increases its apparent viscosity, to the point of becoming a viscoelastic solid. [1] Importantly, the yield stress of the fluid when in its active ("on") state can be controlled very accurately by varying the magnetic field intensity. The upshot is that the fluid's ability to transmit force can be controlled with an electromagnet, which gives rise to its many possible control-based applications.

Contents

MR fluid is different from a ferrofluid which has smaller particles. MR fluid particles are primarily on the micrometre-scale and are too dense for Brownian motion to keep them suspended (in the lower density carrier fluid). Ferrofluid particles are primarily nanoparticles that are suspended by Brownian motion and generally will not settle under normal conditions. As a result, these two fluids have very different applications.

How it works

The magnetic particles, which are typically micrometer or nanometer scale spheres or ellipsoids, are suspended within the carrier oil and distributed randomly in suspension under normal circumstances, as below.

Smart fluid off state.jpg

When a magnetic field is applied, however, the microscopic particles (usually in the 0.110 µm range) align themselves along the lines of magnetic flux, [2] see below.

Smart fluid on state.jpg

Material behavior

To understand and predict the behavior of the MR fluid it is necessary to model the fluid mathematically, a task slightly complicated by the varying material properties (such as yield stress). As mentioned above, smart fluids are such that they have a low viscosity in the absence of an applied magnetic field, but become quasi-solid with the application of such a field. In the case of MR fluids (and ER), the fluid actually assumes properties comparable to a solid when in the activated ("on") state, up until a point of yield (the shear stress above which shearing occurs). This yield stress (commonly referred to as apparent yield stress) is dependent on the magnetic field applied to the fluid, but will reach a maximum point after which increases in magnetic flux density have no further effect, as the fluid is then magnetically saturated. The behavior of a MR fluid can thus be considered similar to a Bingham plastic, a material model which has been well-investigated.

However, MR fluid does not exactly follow the characteristics of a Bingham plastic. For example, below the yield stress (in the activated or "on" state), the fluid behaves as a viscoelastic material, with a complex modulus that is also known to be dependent on the magnetic field intensity. MR fluids are also known to be subject to shear thinning, whereby the viscosity above yield decreases with increased shear rate. Furthermore, the behavior of MR fluids when in the "off" state is also non-Newtonian and temperature dependent, however it deviates little enough for the fluid to be ultimately considered as a Bingham plastic for a simple analysis.

Thus our model of MR fluid behavior in the shear mode becomes:

Where = shear stress; = yield stress; = Magnetic field intensity = Newtonian viscosity; is the velocity gradient in the z-direction.

Shear strength

Low shear strength has been the primary reason for limited range of applications. In the absence of external pressure the maximum shear strength is about 100 kPa. If the fluid is compressed in the magnetic field direction and the compressive stress is 2 MPa, the shear strength is raised to 1100 kPa. [3] If the standard magnetic particles are replaced with elongated magnetic particles, the shear strength is also improved. [4]

Particle sedimentation

Ferroparticles settle out of the suspension over time due to the inherent density difference between the particles and their carrier fluid. The rate and degree to which this occurs is one of the primary attributes considered in industry when implementing or designing an MR device. Surfactants are typically used to offset this effect, but at a cost of the fluid's magnetic saturation, and thus the maximum yield stress exhibited in its activated state.

Common MR fluid surfactants

MR fluids often contain surfactants including, but not limited to: [5]

These surfactants serve to decrease the rate of ferroparticle settling, of which a high rate is an unfavorable characteristic of MR fluids. The ideal MR fluid would never settle, but developing this ideal fluid is as highly improbable as developing a perpetual motion machine according to our current understanding of the laws of physics. Surfactant-aided prolonged settling is typically achieved in one of two ways: by addition of surfactants, and by addition of spherical ferromagnetic nanoparticles. Addition of the nanoparticles results in the larger particles staying suspended longer since the non-settling nanoparticles interfere with the settling of the larger micrometre-scale particles due to Brownian motion. Addition of a surfactant allows micelles to form around the ferroparticles. A surfactant has a polar head and non-polar tail (or vice versa), one of which adsorbs to a ferroparticle, while the non-polar tail (or polar head) sticks out into the carrier medium, forming an inverse or regular micelle, respectively, around the particle. This increases the effective particle diameter. Steric repulsion then prevents heavy agglomeration of the particles in their settled state, which makes fluid remixing (particle redispersion) occur far faster and with less effort. For example, magnetorheological dampers will remix within one cycle with a surfactant additive, but are nearly impossible to remix without them.

While surfactants are useful in prolonging the settling rate in MR fluids, they also prove detrimental to the fluid's magnetic properties (specifically, the magnetic saturation), which is commonly a parameter which users wish to maximize in order to increase the maximum apparent yield stress. Whether the anti-settling additive is nanosphere-based or surfactant-based, their addition decreases the packing density of the ferroparticles while in its activated state, thus decreasing the fluids on-state/activated viscosity, resulting in a "softer" activated fluid with a lower maximum apparent yield stress. While the on-state viscosity (the "hardness" of the activated fluid) is also a primary concern for many MR fluid applications, it is a primary fluid property for the majority of their commercial and industrial applications and therefore a compromise must be met when considering on-state viscosity, maximum apparent yields stress, and settling rate of an MR fluid.

Modes of operation and applications

An MR fluid is used in one of three main modes of operation, these being flow mode, shear mode and squeeze-flow mode. These modes involve, respectively, fluid flowing as a result of pressure gradient between two stationary plates; fluid between two plates moving relative to one another; and fluid between two plates moving in the direction perpendicular to their planes. In all cases the magnetic field is perpendicular to the planes of the plates, so as to restrict fluid in the direction parallel to the plates.

Flow mode (a.k.a. valve mode)

Mr fluid flowmode.jpg

Shear mode

Mr fluid shearmode.jpg

Squeeze-flow mode

Mr fluid squeezeflowmode.jpg

The applications of these various modes are numerous. Flow mode can be used in dampers and shock absorbers, by using the movement to be controlled to force the fluid through channels, across which a magnetic field is applied. Shear mode is particularly useful in clutches and brakes - in places where rotational motion must be controlled. Squeeze-flow mode, on the other hand, is most suitable for applications controlling small, millimeter-order movements but involving large forces. This particular flow mode has seen the least investigation so far. Overall, between these three modes of operation, MR fluids can be applied successfully to a wide range of applications. However, some limitations exist which are necessary to mention here.

Limitations

Although smart fluids are rightly seen as having many potential applications, they are limited in commercial feasibility for the following reasons:

Commercial applications do exist, as mentioned, but will continue to be few until these problems (particularly cost) are overcome.

Advances in the 2000s

Studies published beginning in the late 2000s which explore the effect of varying the aspect ratio of the ferromagnetic particles have shown several improvements over conventional MR fluids. Nanowire-based fluids show no sedimentation after qualitative observation over a period of three months. This observation has been attributed to a lower close-packing density due to decreased symmetry of the wires compared to spheres, as well as the structurally supportive nature of a nanowire lattice held together by remnant magnetization. [6] [7] Further, they show a different range of loading of particles (typically measured in either volume or weight fraction) than conventional sphere- or ellipsoid-based fluids. Conventional commercial fluids exhibit a typical loading of 30 to 90 wt%, while nanowire-based fluids show a percolation threshold of ~0.5 wt% (depending on the aspect ratio). [8] They also show a maximum loading of ~35 wt%, since high aspect ratio particles exhibit a larger per particle excluded volume as well as inter-particle tangling as they attempt to rotate end-over-end, resulting in a limit imposed by high off-state apparent viscosity of the fluids. This range of loadings suggest a new set of applications are possible which may have not been possible with conventional sphere-based fluids.

Newer studies have focused on dimorphic magnetorheological fluids, which are conventional sphere-based fluids in which a fraction of the spheres, typically 2 to 8 wt%, are replaced with nanowires. These fluids exhibit a much lower sedimentation rate than conventional fluids, yet exhibit a similar range of loading as conventional commercial fluids, making them also useful in existing high-force applications such as damping. Moreover, they also exhibit an improvement in apparent yield stress of 10% across those amounts of particle substitution. [9]

Another way to increase the performance of magnetorheological fluids is to apply a pressure to them. In particular the properties in term of yield strength can be increased up to ten times in shear mode [10] and up five times in flow mode. [11] The motivation of this behaviour is the increase in the ferromagnetic particles friction, as described by the semiempirical magneto-tribological model by Zhang et al. Even though applying a pressure strongly improves the magnetorheological fluids behaviour, particular attention must be paid in terms of mechanical resistance and chemical compatibility of the sealing system used.

Applications

The application set for MR fluids is vast, and it expands with each advance in the dynamics of the fluid.

Mechanical engineering

Magnetorheological dampers of various applications have been and continue to be developed. These dampers are mainly used in heavy industry with applications such as heavy motor damping, operator seat/cab damping in construction vehicles, and more.

As of 2006, materials scientists and mechanical engineers are collaborating to develop stand-alone seismic dampers which, when positioned anywhere within a building, will operate within the building's resonance frequency, absorbing detrimental shock waves and oscillations within the structure, giving these dampers the ability to make any building earthquake-proof, or at least earthquake-resistant. [12]

Military and defense

The U.S. Army Research Office is currently funding research into using MR fluid to enhance body armor. In 2003, researchers stated they were five to ten years away from making the fluid bullet resistant. [13] In addition, HMMWVs, and various other all-terrain vehicles employ dynamic MR shock absorbers and/or dampers.

Optics

Magnetorheological finishing, a magnetorheological fluid-based optical polishing method, has proven to be highly precise. It was used in the construction of the Hubble Space Telescope's corrective lens.

Automotive

If the shock absorbers of a vehicle's suspension are filled with magnetorheological fluid instead of a plain oil or gas, and the channels which allow the damping fluid to flow between the two chambers is surrounded with electromagnets, the viscosity of the fluid, and hence the critical frequency of the damper, can be varied depending on driver preference or the weight being carried by the vehicle - or it may be dynamically varied in order to provide stability control across vastly different road conditions. This is in effect a magnetorheological damper. For example, the MagneRide active suspension system permits the damping factor to be adjusted once every millisecond in response to conditions. General Motors (in a partnership with Delphi Corporation) has developed this technology for automotive applications. It made its debut in both Cadillac (Seville STS build date on or after 1/15/2002 with RPO F55) as "Magneride" (or "MR") and Chevrolet passenger vehicles (All Corvettes made since 2003 with the F55 option code) as part of the driver selectable "Magnetic Selective Ride Control (MSRC)" system in model year 2003. Other manufacturers have paid for the use of it in their own vehicles, for example Audi and Ferrari offer the MagneRide on various models.

General Motors and other automotive companies are seeking to develop a magnetorheological fluid based clutch system for push-button four wheel drive systems. This clutch system would use electromagnets to solidify the fluid which would lock the driveshaft into the drive train.

Porsche has introduced magnetorheological engine mounts in the 2010 Porsche GT3 and GT2. At high engine revolutions, the magnetorheological engine mounts get stiffer to provide a more precise gearbox shifter feel by reducing the relative motion between the power train and chassis/body.

As of September 2007, Acura (Honda) has begun an advertising campaign highlighting its use of MR technology in passenger vehicles manufactured for the 2007 MDX model year.

Aerospace

Magnetorheological dampers are under development for use in military and commercial helicopter cockpit seats, as safety devices in the event of a crash. [14] [15] They would be used to decrease the shock delivered to a passenger's spinal column, thereby decreasing the rate of permanent injury during a crash.

Human prosthesis

Magnetorheological dampers are utilized in semi-active human prosthetic legs. Much like those used in military and commercial helicopters, a damper in the prosthetic leg decreases the shock delivered to the patients leg when jumping, for example. This results in an increased mobility and agility for the patient.

Haptic feedback input devices

The company XeelTech and CK Materials Lab in Korea use magnetorheological fluid to generate the haptic feedback of their HAPTICORE rotary switches. The MR actuators are primarily used as input devices with adaptive haptic feedback to enable new possibilities in user interface design. The HAPTICORE technology functions like a miniature MR brake. By changing the magnetic field created by a small electromagnet inside the rotary knob, the friction between the outer shell and the stator is modified in such a way that the user perceives the braking effect as haptic feedback.

By modifying the rheological state of the fluid in near real time, a variety of mechanical rotary knob and cam switch haptic patterns such as ticks, grids, and barriers or limits can be simulated. In addition, it is also possible to generate new forms of haptic feedback, such as speed-adaptive and direction-dependent haptic feedback modes. This technology is used, for example, in HMIs of industrial equipment, household appliances or computer peripherals. [16]

See also

Related Research Articles

Rheology is the study of the flow of matter, primarily in a fluid state, but also as "soft solids" or solids under conditions in which they respond with plastic flow rather than deforming elastically in response to an applied force. Rheology is a branch of physics, and it is the science that deals with the deformation and flow of materials, both solids and liquids.

A viscometer is an instrument used to measure the viscosity of a fluid. For liquids with viscosities which vary with flow conditions, an instrument called a rheometer is used. Thus, a rheometer can be considered as a special type of viscometer. Viscometers can measure only constant viscosity, that is, viscosity that does not change with flow conditions.

A Newtonian fluid is a fluid in which the viscous stresses arising from its flow are at every point linearly correlated to the local strain rate — the rate of change of its deformation over time. Stresses are proportional to the rate of change of the fluid's velocity vector.

<span class="mw-page-title-main">Shear stress</span> Component of stress coplanar with a material cross section

Shear stress is the component of stress coplanar with a material cross section. It arises from the shear force, the component of force vector parallel to the material cross section. Normal stress, on the other hand, arises from the force vector component perpendicular to the material cross section on which it acts.

<span class="mw-page-title-main">Bingham plastic</span> Material which is solid at low stress but becomes viscous at high stress

In materials science, a Bingham plastic is a viscoplastic material that behaves as a rigid body at low stresses but flows as a viscous fluid at high stress. It is named after Eugene C. Bingham who proposed its mathematical form.

Hemorheology, also spelled haemorheology, or blood rheology, is the study of flow properties of blood and its elements of plasma and cells. Proper tissue perfusion can occur only when blood's rheological properties are within certain levels. Alterations of these properties play significant roles in disease processes. Blood viscosity is determined by plasma viscosity, hematocrit and mechanical properties of red blood cells. Red blood cells have unique mechanical behavior, which can be discussed under the terms erythrocyte deformability and erythrocyte aggregation. Because of that, blood behaves as a non-Newtonian fluid. As such, the viscosity of blood varies with shear rate. Blood becomes less viscous at high shear rates like those experienced with increased flow such as during exercise or in peak-systole. Therefore, blood is a shear-thinning fluid. Contrarily, blood viscosity increases when shear rate goes down with increased vessel diameters or with low flow, such as downstream from an obstruction or in diastole. Blood viscosity also increases with increases in red cell aggregability.

<span class="mw-page-title-main">Ferrofluid</span> Special type of liquid which is attracted by poles of a magnet

Ferrofluid is a liquid that is attracted to the poles of a magnet. It is a colloidal liquid made of nanoscale ferromagnetic or ferrimagnetic particles suspended in a carrier fluid. Each magnetic particle is thoroughly coated with a surfactant to inhibit clumping. Large ferromagnetic particles can be ripped out of the homogeneous colloidal mixture, forming a separate clump of magnetic dust when exposed to strong magnetic fields. The magnetic attraction of tiny nanoparticles is weak enough that the surfactant's Van der Waals force is sufficient to prevent magnetic clumping or agglomeration. Ferrofluids usually do not retain magnetization in the absence of an externally applied field and thus are often classified as "superparamagnets" rather than ferromagnets.

In materials science and continuum mechanics, viscoelasticity is the property of materials that exhibit both viscous and elastic characteristics when undergoing deformation. Viscous materials, like water, resist shear flow and strain linearly with time when a stress is applied. Elastic materials strain when stretched and immediately return to their original state once the stress is removed.

<span class="mw-page-title-main">Smart fluid</span> Fluid whose properties can be changed by applying an electric or magnetic field

A smart fluid is a fluid whose properties can be changed by applying an electric field or a magnetic field.

<span class="mw-page-title-main">Electrorheological fluid</span>

Electrorheological (ER) fluids are suspensions of extremely fine non-conducting but electrically active particles in an electrically insulating fluid. The apparent viscosity of these fluids changes reversibly by an order of up to 100,000 in response to an electric field. For example, a typical ER fluid can go from the consistency of a liquid to that of a gel, and back, with response times on the order of milliseconds. The effect is sometimes called the Winslow effect after its discoverer, the American inventor Willis Winslow, who obtained a US patent on the effect in 1947 and wrote an article published in 1949.

Rheometry generically refers to the experimental techniques used to determine the rheological properties of materials, that is the qualitative and quantitative relationships between stresses and strains and their derivatives. The techniques used are experimental. Rheometry investigates materials in relatively simple flows like steady shear flow, small amplitude oscillatory shear, and extensional flow.

Fluid mechanics is that branch of physics concerned with the mechanics of fluids and the forces on them. It has applications in a wide range of disciplines, including mechanical, aerospace, civil, chemical, and biomedical engineering, as well as geophysics, oceanography, meteorology, astrophysics, and biology.

<span class="mw-page-title-main">Shear thinning</span> Non-Newtonian fluid behavior

In rheology, shear thinning is the non-Newtonian behavior of fluids whose viscosity decreases under shear strain. It is sometimes considered synonymous for pseudo-plastic behaviour, and is usually defined as excluding time-dependent effects, such as thixotropy.

Magnetorheological finishing (MRF) is a precision surface finishing technology. Optical surfaces are polished in a computer-controlled magnetorheological (MR) finishing slurry. Unlike conventional rigid lap polishing, the MR fluid's shape and stiffness can be magnetically manipulated and controlled in real time. The optic's final surface form and finishing results are predicted through the use of computer algorithms.

<span class="mw-page-title-main">Yield (engineering)</span> Phenomenon of deformation due to structural stress

In materials science and engineering, the yield point is the point on a stress-strain curve that indicates the limit of elastic behavior and the beginning of plastic behavior. Below the yield point, a material will deform elastically and will return to its original shape when the applied stress is removed. Once the yield point is passed, some fraction of the deformation will be permanent and non-reversible and is known as plastic deformation.

<span class="mw-page-title-main">Sediment transport</span> Movement of solid particles, typically by gravity and fluid entrainment

Sediment transport is the movement of solid particles (sediment), typically due to a combination of gravity acting on the sediment, and the movement of the fluid in which the sediment is entrained. Sediment transport occurs in natural systems where the particles are clastic rocks, mud, or clay; the fluid is air, water, or ice; and the force of gravity acts to move the particles along the sloping surface on which they are resting. Sediment transport due to fluid motion occurs in rivers, oceans, lakes, seas, and other bodies of water due to currents and tides. Transport is also caused by glaciers as they flow, and on terrestrial surfaces under the influence of wind. Sediment transport due only to gravity can occur on sloping surfaces in general, including hillslopes, scarps, cliffs, and the continental shelf—continental slope boundary.

A magnetorheological damper or magnetorheological shock absorber is a damper filled with magnetorheological fluid, which is controlled by a magnetic field, usually using an electromagnet. This allows the damping characteristics of the shock absorber to be continuously controlled by varying the power of the electromagnet. Fluid viscosity increases within the damper as electromagnet intensity increases. This type of shock absorber has several applications, most notably in semi-active vehicle suspensions which may adapt to road conditions, as they are monitored through sensors in the vehicle, and in prosthetic limbs.

<span class="mw-page-title-main">Viscosity</span> Resistance of a fluid to shear deformation

The viscosity of a fluid is a measure of its resistance to deformation at a given rate. For liquids, it corresponds to the informal concept of "thickness": for example, syrup has a higher viscosity than water. Viscosity is defined scientifically as a force multiplied by a time divided by an area. Thus its SI units are newton-seconds per square meter, or pascal-seconds.

An important class of non-Newtonian fluids presents a yield stress limit which must be exceeded before significant deformation can occur – the so-called viscoplastic fluids or Bingham plastics. In order to model the stress-strain relation in these fluids, some fitting have been proposed such as the linear Bingham equation and the non-linear Herschel-Bulkley and Casson models.

Squeeze flow is a type of flow in which a material is pressed out or deformed between two parallel plates or objects. First explored in 1874 by Josef Stefan, squeeze flow describes the outward movement of a droplet of material, its area of contact with the plate surfaces, and the effects of internal and external factors such as temperature, viscoelasticity, and heterogeneity of the material. Several squeeze flow models exist to describe Newtonian and non-Newtonian fluids undergoing squeeze flow under various geometries and conditions. Numerous applications across scientific and engineering disciplines including rheometry, welding engineering, and materials science provide examples of squeeze flow in practical use.

References

Notes

  1. Bahl, Shashi; Nagar, Himanshu; Singh, Inderpreet; Sehgal, Shankar (2020-01-01). "Smart materials types, properties and applications: A review". Materials Today: Proceedings. International Conference on Aspects of Materials Science and Engineering. 28: 1302–1306. doi:10.1016/j.matpr.2020.04.505. ISSN   2214-7853. S2CID   219435304.
  2. Unuh, Mohd Hishamuddin; Muhamad, Pauziah (2020). "A Brief Review of Preparation Method and Challenges of Magnetorheological Fluids". Journal of Advanced Research in Material Science. Akademia Baru Publishing. 74 (1): 1–18. doi: 10.37934/arms.74.1.118 . ISSN   2289-7992.
  3. Wang, Hong-yun; Zheng, Hui-qiang; Li, Yong-xian; Lu, Shuang (17 December 2008). Fei, Yetai; Fan, Kuang-Chao; Lu, Rongsheng (eds.). "Mechanical properties of magnetorheological fluids under squeeze-shear mode". Fourth International Symposium on Precision Mechanical Measurements. 7130: 71302M. Bibcode:2008SPIE.7130E..2MW. doi:10.1117/12.819634. S2CID   137422177.
  4. Vereda, Fernando; de Vicente, Juan; Hidalgo-Álvarez, Roque (2 June 2009). "Physical Properties of Elongated Magnetic Particles: Magnetization and Friction Coefficient Anisotropies". ChemPhysChem. 10 (8): 1165–1179. doi:10.1002/cphc.200900091. PMID   19434654.
  5. Unuh, Mohd Hishamuddin; Muhamad, Pauziah; Waziralilah, Nur Fathiah; Amran, Mohamad Hafiz (2019). "Characterization of Vehicle Smart Fluid using Gas Chromatography-Mass Spectrometry (GCMS)" (PDF). Journal of Advanced Research in Fluid Mechanics and Thermal Sciences. Penerbit Akademia Baru. 55 (2): 240–248. ISSN   2289-7879.
  6. Bell, R C; Karli, J O; Vavreck, A N; Zimmerman, D T; Ngatu, G T; Wereley, N M (1 February 2008). "Magnetorheology of submicron diameter iron microwires dispersed in silicone oil". Smart Materials and Structures. 17 (1): 015028. Bibcode:2008SMaS...17a5028B. doi:10.1088/0964-1726/17/01/015028. S2CID   137287721.
  7. Bell, R. C.; Miller, E. D.; Karli, J. O.; Vavreck, A. N.; Zimmerman, D. T. (10 November 2007). "Influence of particle shape on the properties of magnetorheological fluids". International Journal of Modern Physics B. 21 (28n29): 5018–5025. Bibcode:2007IJMPB..21.5018B. doi:10.1142/S0217979207045979.
  8. Zimmerman, D. T.; Bell, R. C.; Filer, J. A.; Karli, J. O.; Wereley, N. M. (6 July 2009). "Elastic percolation transition in nanowire-based magnetorheological fluids". Applied Physics Letters. 95 (1): 014102. Bibcode:2009ApPhL..95a4102Z. doi:10.1063/1.3167815.
  9. Ngatu, G T; Wereley, N M; Karli, J O; Bell, R C (1 August 2008). "Dimorphic magnetorheological fluids: exploiting partial substitution of microspheres by nanowires". Smart Materials and Structures. 17 (4): 045022. Bibcode:2008SMaS...17d5022N. doi:10.1088/0964-1726/17/4/045022. S2CID   108884548.
  10. Zhang, X. Z.; Gong, X. L.; Zhang, P. Q.; Wang, Q. M. (15 August 2004). "Study on the mechanism of the squeeze-strengthen effect in magnetorheological fluids". Journal of Applied Physics. 96 (4): 2359–2364. Bibcode:2004JAP....96.2359Z. doi:10.1063/1.1773379.
  11. Spaggiari, A.; Dragoni, E. (1 September 2012). "Effect of Pressure on the Flow Properties of Magnetorheological Fluids". Journal of Fluids Engineering. 134 (9). doi:10.1115/1.4007257.
  12. Bonsor, Kevin (4 October 2023). "The Tuned Mass Damper: How Science Could Earthquake-Proof the Skyscrapers of Tomorrow". HowStuffWorks. Archived from the original on 24 January 2024.
  13. Lurie, Karen. "Instant Armour". sciencentral.com. Archived from the original on 13 February 2012.
  14. Hiemenz, Gregory J.; Choi, Young-Tai; Wereley, Norman M. (May 2007). "Semi-Active Control of Vertical Stroking Helicopter Crew Seat for Enhanced Crashworthiness". Journal of Aircraft. 44 (3): 1031–1034. doi:10.2514/1.26492.
  15. Wereley, Norman M.; Singh, Harinder J.; Choi, Young-Tai (2014). "CHAPTER 12: Adaptive Magnetorheological Energy Absorbing Mounts for Shock Mitigation". Magnetorheology: advances and applications. Cambridge, UK: RSC Publishing. pp. 278–287. Bibcode:2014maa..book.....W. doi:10.1039/9781849737548. ISBN   978-1-84973-754-8.
  16. XeelTech GmbH (2023). "HAPTICORE Technology – Next generation haptic knob with programmable haptic force feedback"

Sources