Caliper(s) or calliper(s) are an instrument used to measure the linear dimensions of an object or hole; namely, the length, width, thickness, diameter or depth of an object or hole. The word "caliper" comes from a corrupt form of caliber. [1] [2] [3]
Many types of calipers permit reading out a measurement on a ruled scale, a dial, or an electronic digital display. A common association is to calipers using a sliding vernier scale.
Some calipers can be as simple as a compass with inward or outward-facing points, but with no scale (measurement indication). The tips of the caliper are adjusted to fit across the points to be measured, and then kept at that span while moved to separate measuring device, such as a ruler.
Calipers are used in many fields such as mechanical engineering, metalworking, forestry, woodworking, science and medicine.
Caliper is the American spelling, while calliper (double "L") is the British spelling.
A single tool might be referred to as a caliper or as calipers — a plural only (plurale tantum) form, like scissors or glasses.
Colloquially, the phrase "pair of verniers" or just "vernier" might refer to a vernier caliper. In loose colloquial usage, these phrases may also refer to other kinds of calipers, although they involve no vernier scale. In machine-shop usage, the term "caliper" is often used in contradistinction to micrometer, even though outside micrometers are technically a form of caliper. In this usage, caliper implies only the form factor of the instrument.
The earliest caliper has been found in the Greek Giglio wreck near the Italian coast. The ship's find dates to the 6th century BC. The wooden piece already featured a fixed and a movable jaw. [4] [5] Although rare finds, calipers remained in use by the Greeks and Romans. [5] [6]
A bronze caliper, dating from 9 AD, was used for minute measurements during the Chinese Xin dynasty. The caliper had an inscription stating that it was "made on the gui-you day, [a] the first day [b] of the first month of the first year of Shijianguo. [c] " The calipers included a "slot and pin" and "graduated in inches and tenths of an inch." [7] [8]
The modern vernier caliper was invented by Pierre Vernier, as an improvement of the nonius of Pedro Nunes.
Inside calipers are used to measure the internal size of an object.
Outside calipers are used to measure the external size of an object.
The same observations and technique apply to this type of caliper, as for the inside caliper. With some understanding of their limitations and usage, these instruments can provide a high degree of accuracy and repeatability. They are especially useful when measuring over very large distances; consider if the calipers are used to measure a large diameter pipe. A vernier caliper does not have the depth capacity to straddle this large diameter and at the same time reach the outermost points of the pipe's diameter. They are made from high carbon steel.
In the metalworking field, a divider caliper, popularly called a compass, is used to mark out locations. The points are sharpened so that they act as scribers; one leg can then be placed in the dimple created by a center or prick punch and the other leg pivoted so that it scribes a line on the workpiece's surface, thus forming an arc or circle.
Their namesake use is in dividing a workpiece of arbitrary width into equal-width sections: by "walking" the tool from one end to the other by pivoting it from one point to the next until reaching the other end, then adjusting the gap between the points until the "walk" ends directly on the end point, equal divisions can be easily marked out without any measuring.
A divider caliper is also used to measure a distance between two points on a map. The two caliper ends are brought to the two points whose distance is being measured. The caliper's opening is then either measured on a separate ruler and then converted to the actual distance, or measured directly on a scale drawn on the map. On a nautical chart the distance is often measured on the latitude scale appearing on the sides of the map: one minute of arc along any great circle, e.g. any longitude meridian, is approximately one nautical mile or 1852 meters.
Dividers are also used in the medical profession. An ECG (also EKG) caliper transfers distance on an electrocardiogram; in conjunction with the appropriate scale, the heart rate can be determined. A pocket caliper version was invented by cardiologist Robert A. Mackin. [9] [ failed verification ]
Oddleg calipers, Hermaphrodite calipers, or Oddleg Jennys, as pictured on the left, are generally used to scribe a line at a set distance from the edge of a workpiece. The bent leg is used to run along the workpiece edge while the scriber makes its mark at a predetermined distance, this ensures a line parallel to the edge.
In the diagram at left, the uppermost caliper has a slight shoulder in the bent leg allowing it to sit on the edge more securely. The lower caliper lacks this feature but has a renewable scriber that can be adjusted for wear, as well as being replaced when excessively worn.
The labelled parts are
The calipers in the diagram show a primary reading on the metric scale of about 2.475 cm (2.4 cm read from the main scale plus about 0.075 cm from the vernier scale).
Calipers often have a "zero point error": meaning that the calipers do not read 0.000 cm when the jaws are closed. The zero point error must always be subtracted from the primary reading. Let us assume these calipers have a zero-point error of 0.013 cm. This would give us a length reading of 2.462 cm.
For any measurement, reporting the error on the measurement is also important. Ignoring the possibility of interpolation by eye, both the primary reading and the zero point reading are bounded by plus/minus half the length corresponding to the width of the smallest interval on the vernier scale (0.0025 cm). These are "absolute" errors and absolute errors add, so the length reading is then bounded by plus/minus the length corresponding to the full width of the smallest interval on the vernier scale (0.005 cm). Assuming no systematics affect the measurement (the instrument works perfectly), a complete measurement would then read 2.462 cm ± 0.005 cm.
The vernier, dial, and digital calipers directly read the distance measured with high accuracy and precision. They are functionally identical, with different ways of reading the result. These calipers comprise a calibrated scale with a fixed jaw, and another jaw, with a pointer, that slides along the scale. The distance between the jaws is then read in different ways for the three types.
The simplest method is to read the position of the pointer directly on the scale. When the pointer is between two markings, the user can mentally interpolate to improve the precision of the reading. This would be a simply calibrated caliper, but the addition of a vernier scale allows more accurate interpolation and is the universal practice; this is the vernier caliper.
Vernier, dial, and digital calipers can measure internal dimensions (using the uppermost jaws in the picture at right), external dimensions using the pictured lower jaws, and in many cases depth by the use of a probe that is attached to the movable head and slides along the centre of the body. This probe is slender and can get into deep grooves that may prove difficult for other measuring tools.
The vernier scales may include metric measurements on the lower part of the scale and inch measurements on the upper, or vice versa, in countries that use inches. Vernier calipers commonly used in industry provide a precision to 0.01 mm (10 micrometres), or one thousandth of an inch. They are available in sizes that can measure up to 1828 mm (72 in). [10]
Instead of using a vernier mechanism, which requires some practice to use, the dial caliper reads the final fraction of a millimeter or inch on a simple dial.
In this instrument, a small, precise rack and pinion drives a pointer on a circular dial, allowing direct reading without the need to read a vernier scale. Typically, the pointer rotates once every inch, tenth of an inch, or 1 millimeter. This measurement must be added to the coarse whole inches or centimeters read from the slide. The dial is usually arranged to be rotatable beneath the pointer, allowing for "differential" measurements (the measuring of the difference in size between two objects, or the setting of the dial using a master object and subsequently being able to read directly the plus-or-minus variance in the size of subsequent objects relative to the master object).
The slide of a dial caliper can usually be locked at a setting using a small lever or screw; this allows simple go/no-go checks of part sizes.
Rather than a rack and pinion, digital calipers use a linear encoder. A liquid-crystal display shows the measurement, which often can switch units between millimeters and fractional or decimal inches. All provide for zeroing the display at any point along the slide, allowing the same sort of differential measurements as with the dial caliper. Digital calipers may contain a "reading hold" feature, allowing the reading of dimensions after use in awkward locations where the display cannot be seen. Like analog calipers, the slide of many digital calipers can be locked using a lever or screw.
Ordinary 150 mm (6 in) digital calipers made of stainless steel have a rated accuracy of 0.02 mm (0.001 in) and a resolution of 0.01 mm (0.0005 in). [11] The same technology is used for longer calipers, but accuracy declines to 0.03 mm (0.001 in) for 100–200 mm (4–8 in) and 0.04 mm (0.0015 in) for 200–300 mm (8–12 in) measurements. [12]
Many digital calipers contain a capacitive linear encoder. Inexpensive Chinese models have 56 narrow emitter plates and one long receiver plate etched on the sliding display's printed circuit board, which intersect with a repeating pattern of T-shaped plates in the longer "stator" board. The top of the "T" plates intersect with the receiver plate, while the vertical bars of each "T" intersect with the emitter plates. The pitch of each "T" in the stator is slightly less than 8 times the pitch of each emitter plate, so their intersecting capacitive area is not perfectly aligned but rather forms an interference pattern. [15] As the slider moves, these variable capacitances change in a repeating linear fashion. The slider's circuitry counts these repetitions as it slides and achieves finer resolution using linear interpolation of the capacitances. [16] One model sends 8 periodic pulse-width modulation voltage signals (which appear identical but out of phase by 1⁄8 of the period), [17] each connected to 7 emitter plates, and the resulting analog signal is read through a single receiver plate. [18] The 1983 German patent DE3340782C2 (see figure) is said to describe the workings. [19]
Other digital calipers contain an inductive linear encoder, which allows robust performance in the presence of contamination such as coolants. [20] Magnetic linear encoders are used in yet other digital calipers.[ citation needed ]
Digital calipers nowadays offer serial data output to expedite repeated measurements, avoid human error, and allow direct data entry into a digital recorder, spreadsheet, statistical process control program, or similar software on a personal computer. Interfacing devices based on RS-232, Universal Serial Bus, or wireless can be built or purchased. The serial digital output varies among manufacturers, but common options are:
A caliper using a calibrated screw for measurement, rather than a slide, is called an external micrometer caliper gauge, a micrometer caliper or, more often, simply a micrometer. (Sometimes the term caliper, referring to any other type in this article, is held in contradistinction to micrometer.)
Each of the above types of calipers has its relative merits and faults.
Vernier calipers are rugged and have long-lasting accuracy, are coolant proof, are not affected by magnetic fields, and are largely shockproof. They may have both centimeter and inch scales. However, vernier calipers require good eyesight or a magnifying glass to read and can be difficult to read from a distance or from awkward angles. It is relatively easy to misread the last digit. In production environments, reading vernier calipers all day long is error-prone and is annoying to the workers.
Dial calipers are comparatively easy to read, especially when seeking the exact center by rocking and observing the needle movement. They can be set to 0 at any point for comparisons. They are usually fairly susceptible to shock damage. They are also very prone to getting dirt in the gears, which can cause accuracy problems.
Digital calipers switch easily between centimeter and inch systems. They can be set to zero easily at any point with a full count in either direction and can take measurements even if the display is completely hidden, either by using a "hold" key, or by zeroing the display and closing the jaws, showing the correct measurement, but negative. They can be mechanically and electronically fragile. Most also require batteries and do not resist coolant well. They are also only moderately shockproof and can be vulnerable to dirt.
Calipers may read to a resolution of 0.01 mm or 0.0005 in, but accuracy may not be better than about ±0.02 mm or 0.001 in for 150 mm (6 in) calipers, and worse for longer ones. [28]
A caliper must be properly applied against the part in order to take the desired measurement. For example, when measuring the thickness of a plate, a vernier caliper must be held at right angles to the piece. Some practice may be needed to measure round or irregular objects correctly.
Accuracy of measurement when using a caliper is highly dependent on the skill of the operator. Regardless of type, a caliper's jaws must be forced into contact with the part being measured. As both part and caliper are always to some extent elastic, the amount of force used affects the indication. A consistent, firm touch is correct. Too much force results in an under indication as part and tool distort; too little force gives insufficient contact and an over indication. This is a greater problem with a caliper incorporating a wheel, which lends mechanical advantage. This is especially the case with digital calipers, calipers out of adjustment, or calipers with a poor quality beam.
Simple calipers are uncalibrated; the measurement taken must be compared against a scale. Whether the scale is part of the caliper or not, all analog calipers—verniers and dials—require good eyesight in order to achieve the highest precision. Digital calipers have an advantage in this area.
Calibrated calipers may be mishandled, leading to loss of zero. When a caliper's jaws are fully closed, it should, of course, indicate zero. If it does not, it must be recalibrated or repaired. A vernier caliper does not easily lose its calibration, but a sharp impact or accidental damage to the measuring surface in the caliper jaw can be significant enough to displace zero. [29] Digital calipers have zero set buttons, for quick recalibration.
Vernier, dial and digital calipers can be used with accessories that extend their usefulness. Examples are a base that extends their usefulness as a depth gauge and a jaw attachment that all allows measuring the center distance between holes. Since the 1970s, a clever modification of the moveable jaw on the back side of any caliper allows for step or depth measurements in addition to external caliper measurements, similarly to a universal micrometer (e.g., Starrett Mul-T-Anvil or Mitutoyo Uni-Mike).
The method to use a vernier scale or caliper with zero error is to use the formula "actual reading = main scale + vernier scale − (zero error)". Zero error may arise due to knocks that affect the calibration at 0.00 mm when the jaws are perfectly closed or just touching each other. Positive zero error refers to the fact that when the jaws of the vernier caliper are just closed, the reading is a positive reading away from the actual reading of 0.00 mm. If the reading is 0.10 mm, the zero error is referred to as +0.10 mm. Negative zero error refers to the fact that when the jaws of the vernier caliper are just closed, the reading is a negative reading away from the actual reading of 0.00 mm. If the reading is −0.08 mm, the zero error is referred to as −0.08 mm.
Calipers with measurement axes displaced from the object being measured suffer from Abbe error if the jaws are not perpendicular due to manufacturing tolerances. Unlike zero error, the amount of Abbe error depends on the offset. [30]
Pressure measurement is the measurement of an applied force by a fluid on a surface. Pressure is typically measured in units of force per unit of surface area. Many techniques have been developed for the measurement of pressure and vacuum. Instruments used to measure and display pressure mechanically are called pressure gauges,vacuum gauges or compound gauges. The widely used Bourdon gauge is a mechanical device, which both measures and indicates and is probably the best known type of gauge.
A sextant is a doubly reflecting navigation instrument that measures the angular distance between two visible objects. The primary use of a sextant is to measure the angle between an astronomical object and the horizon for the purposes of celestial navigation.
A multimeter is a measuring instrument that can measure multiple electrical properties. A typical multimeter can measure voltage, resistance, and current, in which case can be used as a voltmeter, ohmmeter, and ammeter. Some feature the measurement of additional properties such as temperature and capacitance.
A micrometer, sometimes known as a micrometer screw gauge, is a device incorporating a calibrated screw widely used for accurate measurement of components in mechanical engineering and machining as well as most mechanical trades, along with other metrological instruments such as dial, vernier, and digital calipers. Micrometers are usually, but not always, in the form of calipers. The spindle is a very accurately machined screw and the object to be measured is placed between the spindle and the anvil. The spindle is moved by turning the ratchet knob or thimble until the object to be measured is lightly touched by both the spindle and the anvil.
A vernier scalever-NEE-er), named after Pierre Vernier, is a visual aid to take an accurate measurement reading between two graduation markings on a linear scale by using mechanical interpolation, thereby increasing resolution and reducing measurement uncertainty by using vernier acuity to reduce human estimation error. It may be found on many types of instrument measuring linear or angular quantities, but in particular on a vernier caliper, which measures lengths.
A theodolite is a precision optical instrument for measuring angles between designated visible points in the horizontal and vertical planes. The traditional use has been for land surveying, but it is also used extensively for building and infrastructure construction, and some specialized applications such as meteorology and rocket launching.
A speedometer or speed meter is a gauge that measures and displays the instantaneous speed of a vehicle. Now universally fitted to motor vehicles, they started to be available as options in the early 20th century, and as standard equipment from about 1910 onwards. Other vehicles may use devices analogous to the speedometer with different means of sensing speed, eg. boats use a pit log, while aircraft use an airspeed indicator.
A goniometer is an instrument that either measures an angle or allows an object to be rotated to a precise angular position. The term goniometry derives from two Greek words, γωνία (gōnía) 'angle' and μέτρον (métron) 'measure'. The protractor is a commonly used type in the fields of mechanics, engineering, and geometry.
A scale or balance is a device used to measure weight or mass. These are also known as mass scales, weight scales, mass balances, massometers, and weight balances.
In various contexts of science, technology, and manufacturing, an indicator is any of various instruments used to accurately measure small distances and angles, and amplify them to make them more obvious. The name comes from the concept of indicating to the user that which their naked eye cannot discern; such as the presence, or exact quantity, of some small distance.
A bore gauge is a collective term for the tools that are unique to the process of accurately measuring holes.
Gauge blocks are a system for producing precision lengths. The individual gauge block is a metal or ceramic block that has been precision ground and lapped to a specific thickness. Gauge blocks come in sets of blocks with a range of standard lengths. In use, the blocks are stacked to make up a desired length.
A linear encoder is a sensor, transducer or readhead paired with a scale that encodes position. The sensor reads the scale in order to convert the encoded position into an analog or digital signal, which can then be decoded into position by a digital readout (DRO) or motion controller.
In electrical and electronic engineering, a current clamp, also known as current probe, is an electrical device with jaws which open to allow clamping around an electrical conductor. This allows measurement of the current in a conductor without the need to make physical contact with it, or to disconnect it for insertion through the probe.
A thousandth of an inch is a derived unit of length in a system of units using inches. Equal to 1⁄1000 of an inch, a thousandth is commonly called a thou or, particularly in North America, a mil.
In the science of measurement, the least count of a measuring instrument is the smallest value in the measured quantity that can be resolved on the instrument's scale. The least count is related to the precision of an instrument; an instrument that can measure smaller changes in a value relative to another instrument, has a smaller "least count" value and so is more precise. Any measurement made by the instrument can be considered repeatable to no less than the resolution of the least count. The least count of an instrument is inversely proportional to the precision of the instrument.
Diameter at breast height, or DBH, is a standard method of expressing the diameter of the trunk or bole of a standing tree. DBH is one of the most common dendrometric measurements.
A travelling microscope is an instrument for measuring length with a resolution typically in the order of 0.01mm. The precision is such that better-quality instruments have measuring scales made from Invar to avoid misreadings due to thermal effects. The instrument comprises a microscope mounted on two rails fixed to, or part of a very rigid bed. The position of the microscope can be varied coarsely by sliding along the rails, or finely by turning a screw. The eyepiece is fitted with fine cross-hairs to fix a precise position, which is then read off the vernier scale. Some instruments, such as that produced in the 1960s by the Precision Tool and Instrument Company of Thornton Heath, Surrey, England, also measure vertically. The purpose of the microscope is to aim at reference marks with much higher accuracy than is possible using the naked eye. It is used in laboratories to measure the refractive index of flat specimens using the geometrical concepts of ray optics. It is also used to measure very short distances precisely, for example the diameter of a capillary tube. This mechanical instrument has now largely been superseded by electronic- and optically based measuring devices that are both very much more accurate and considerably cheaper to produce.
A diameter tape (D-tape) is a measuring tape used to estimate the diameter of a cylinder object, typically the stem of a tree or pipe. A diameter tape has either metric or imperial measurements reduced by the value of π. This means the tape measures the diameter of the object. It is assumed that the cylinder object is a perfect circle. The diameter tape provides an approximation of diameter; most commonly used in dendrometry.
A Philadelphia rod is a level staff used in surveying. The rod is used in levelling procedures to determine elevations and is read using a level.
adjustable outside caliper gauge... self-dated at AD 9. An abridged version.